(10A, 15A, 20A type)
(30A, 40A type)
AQ-R
High capacity SSR,
both tab and screw
terminals available
AQ-R RELAYS
APPLICATIONS
1. Molding machine (heater control)
2. Temperature controlled bath (heater
control)
3. Printing machine (heater control)
4. Machine tool (motor control)
FEATURES
1. Two types of terminal shape: Plug-in
terminal and Screw terminal (30 A, 40
A is screw terminal types only)
2. Flat type of SSR possible by
aluminium printed circuit board
3. High dielectric strength of 1,500 V
between input and output. 4,000 V
available for 10A, 15A, 20A devices.
4. Heat sink and DIN mounting rail and
terminal cover are available as
accessories
Compliance with RoHS Directive
ORDERING INFORMATION
AQR
AQR Solid state Relay
Load current
10 A
15 A
20 A
30 A
40 A
Load voltage
1: 75 to 125 V AC
2: 75 to 250 V AC
Terminal shape
Nil: Plug-in terminal
S: Screw terminal
Type
Z: Zero-cross type (1,500 V)
ZV: Zero-cross type (4,000 V)
Input voltage
4/6 V DC
10/18 V DC
18/28 V DC
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
TYPES
1. Tab terminal type
Type
Load current
Load voltage
Input voltage
4 to 6V DC
75 to 125V AC
10 A
75 to 250V AC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
75 to 125 V AC
Zero-cross
15 A
75 to 250 V AC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
75 to 125 V AC
20 A
75 to 250 V AC
Standard packing: Carton 10 pcs., Case: 100 pcs.
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
Standard (1,500V AC)
Part No.
AQR10A1-Z4/6VDC
AQR10A1-Z10/18VDC
AQR10A1-Z18/28VDC
AQR10A2-Z4/6VDC
AQR10A2-Z10/18VDC
AQR10A2-Z18/28VDC
AQR15A1-Z4/6VDC
AQR15A1-Z10/18VDC
AQR15A1-Z18/28VDC
AQR15A2-Z4/6VDC
AQR15A2-Z10/18VDC
AQR15A2-Z18/28VDC
AQR20A1-Z4/6VDC
AQR20A1-Z10/18VDC
AQR20A1-Z18/28VDC
AQR20A2-Z4/6VDC
AQR20A2-Z10/18VDC
AQR20A2-Z18/28VDC
Reinforced (4,000V AC)
Part No.
—
—
—
AQR10A2-ZV4/6VDC
AQR10A2-ZV10/18VDC
AQR10A2-ZV18/28VDC
—
—
—
AQR15A2-ZV4/6VDC
AQR15A2-ZV10/18VDC
AQR15A2-ZV18/28VDC
—
—
—
AQR20A2-ZV4/6VDC
AQR20A2-ZV10/18VDC
AQR20A2-ZV18/28VDC
2. Screw-terminal type
Type
Load current
Load voltage
Input voltage
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
Standard (1,500V AC)
Part No.
AQR10A1-S-Z4/6VDC
AQR10A1-S-Z10/18VDC
AQR10A1-S-Z18/28VDC
AQR10A2-S-Z4/6VDC
AQR10A2-S-Z10/18VDC
AQR10A2-S-Z18/28VDC
AQR15A1-S-Z4/6VDC
AQR15A1-S-Z10/18VDC
AQR15A1-S-Z18/28VDC
AQR15A2-S-Z4/6VDC
AQR15A2-S-Z10/18VDC
AQR15A2-S-Z18/28VDC
AQR20A1-S-Z4/6VDC
AQR20A1-S-Z10/18VDC
AQR20A1-S-Z18/28VDC
AQR20A2-S-Z4/6VDC
AQR20A2-S-Z10/18VDC
AQR20A2-S-Z18/28VDC
AQR30A2-S-Z4/6VDC
AQR30A2-S-Z10/18VDC
AQR30A2-S-Z18/28VDC
AQR40A2-S-Z4/6VDC
AQR40A2-S-Z10/18VDC
AQR40A2-S-Z18/28VDC
Reinforced (4,000V AC)
Part No.
—
—
—
AQR10A2-S-ZV4/6VDC
AQR10A2-S-ZV10/18VDC
AQR10A2-S-ZV18/28VDC
—
—
—
AQR15A2-S-ZV4/6VDC
AQR15A2-S-ZV10/18VDC
AQR15A2-S-ZV18/28VDC
—
—
—
AQR20A2-S-ZV4/6VDC
AQR20A2-S-ZV10/18VDC
AQR20A2-S-ZV18/28VDC
—
—
—
—
—
—
75 to 125 V AC
10 A
75 to 250 V AC
75 to 125 V AC
15 A
75 to 250 V AC
Zero-cross
75 to 125 V AC
20 A
75 to 250 V AC
30 A
75 to 250 V AC
40 A
75 to 250 V AC
Standard packing: Carton 10 pcs., Case: 100 pcs.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
SPECIFICATIONS
1. Ratings
(at 20°C
68°F,
Input ripple: 1% or less)
1) 10 A type
Part No.
AQR10A1-Z4/
6VDC
AQR10A1-S-Z4/
6VDC
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
Max. load current
Load voltage
Frequency
Repetitive peak
voltage
Load
side
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
OFF-state dV/dt
75 to 125 V AC
45 to 65 Hz
400 V
100 A*
3
2.5 mA (when 100 V AC applied)
1.6 V
100 mA*
4
100 V/µs
5 mA (when 200 V AC applied)
600 V
In one cycle at
60 Hz
at 60 Hz
at max.
carrying current
4 to 6V DC
Approx. 0.26 kΩ
10 to 18V DC
Approx. 0.86 kΩ
18 to 28V DC
Approx. 1.36 kΩ
1V
10 A*
2
75 to 250 V AC
Ta = Max. 40°C
104°F
AQR10A1-Z10/
18VDC
AQR10A1-S-Z10/
18VDC
AQR10A1-Z18/
28VDC
AQR10A1-S-Z18/
28VDC
AQR10A2-Z4/
6VDC
AQR10A2-ZV4/
6VDC
AQR10A2-S-Z4/
6VDC
AQR10A2-S-ZV4/
6VDC
4 to 6V DC
Approx. 0.26 kΩ
AQR10A2-Z10/
18VDC
AQR10A2-ZV10/
18VDC
AQR10A2-S-Z10/
18VDC
AQR10A2-S-
ZV10/18VDC
10 to 18V DC
Approx. 0.86 kΩ
AQR10A2-Z18/
28VDC
AQR10A2-ZV18/
28VDC
AQR10A2-S-Z18/
28VDC
AQR10A2-S-
ZV18/28VDC
18 to 28V DC
Approx. 1.36 kΩ
Remarks
*
1
2) 15 A type
Part No.
AQR15A1-Z4/
6VDC
AQR15A1-S-Z4/
6VDC
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
Max. load current
Load voltage
Frequency
Repetitive peak
voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
OFF-state dV/dt
Notes: *1.
*2.
*3.
*4.
75 to 125 V AC
45 to 65 Hz
400 V
150 A*
3
2.5 mA (when 100 V AC applied)
1.6 V
100 mA*
4
100 V/µs
5 mA (when 200 V AC applied)
600 V
In one cycle at
60 Hz
at 60 Hz
at max.
carrying current
4 to 6V DC
Approx. 0.26 kΩ
10 to 18V DC
Approx. 0.86 kΩ
18 to 28V DC
Approx. 1.36 kΩ
1V
15 A*
2
75 to 250 V AC
Ta = Max. 40°C
104°F
AQR15A1-Z10/
18VDC
AQR15A1-S-Z10/
18VDC
AQR15A1-Z18/
28VDC
AQR15A1-S-Z18/
28VDC
AQR15A2-Z4/
6VDC
AQR15A2-ZV4/
6VDC
AQR15A2-S-Z4/
6VDC
AQR15A2-S-ZV4/
6VDC
4 to 6V DC
Approx. 0.26 kΩ
AQR15A2-Z10/
18VDC
AQR15A2-ZV10/
18VDC
AQR15A2-S-Z10/
18VDC
AQR15A2-S-
ZV10/18VDC
10 to 18V DC
Approx. 0.86 kΩ
AQR15A2-Z18/
28VDC
AQR15A2-ZV18/
28VDC
AQR15A2-S-Z18/
28VDC
AQR15A2-S-
ZV18/28VDC
18 to 28V DC
Approx. 1.36 kΩ
Remarks
*
1
Load
side
Refer to REFERENCE DATA “3. Input current vs. input voltage”.
Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
3) 20 A type
Part No.
AQR20A1-Z4/
6VDC
AQR20A1-S-Z4/
6VDC
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
Max. load current
Load voltage
Frequency
Repetitive peak
voltage
Load
side
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
OFF-state dV/dt
75 to 125 V AC
45 to 65 Hz
400 V
200 A*
3
2.5 mA (when 100 V AC applied)
1.6 V
100 mA*
4
100 V/µs
5 mA (when 200 V AC applied)
600 V
In one cycle at
60 Hz
at 60 Hz
at max.
carrying current
4 to 6V DC
Approx. 0.26 kΩ
10 to 18V DC
Approx. 0.86 kΩ
18 to 28V DC
Approx. 1.36 kΩ
1V
20 A*
2
75 to 250 V AC
Ta = Max. 40°C
104°F
AQR20A1-Z10/
18VDC
AQR20A1-S-Z10/
18VDC
AQR20A1-Z18/
28VDC
AQR20A1-S-Z18/
28VDC
AQR20A2-Z4/
6VDC
AQR20A2-ZV4/
6VDC
AQR20A2-S-Z4/
6VDC
AQR20A2-S-ZV4/
6VDC
4 to 6V DC
Approx. 0.26 kΩ
AQR20A2-Z10/
18VDC
AQR20A2-ZV10/
18VDC
AQR20A2-S-Z10/
18VDC
AQR20A2-S-
ZV10/18VDC
10 to 18V DC
Approx. 0.86 kΩ
AQR20A2-Z18/
28VDC
AQR20A2-ZV18/
28VDC
AQR20A2-S-Z18/
28VDC
AQR20A2-S-
ZV18/28VDC
18 to 28V DC
Approx. 1.36 kΩ
Remarks
*
1
4) 30 A type and 40 A type
Part No.
Items
Input
side
Input voltage
Input impedance
Drop-out voltage,
min.
Max. load current
Load voltage
Frequency
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
Notes: *1.
*2.
*3.
*4.
AQR30A2-S-Z4/
6VDC
4 to 6V DC
Approx. 0.26 kΩ
AQR30A2-S-Z10/
18VDC
10 to 18V DC
Approx. 0.86 kΩ
AQR30A2-S-Z18/
28VDC
18 to 28V DC
Approx. 1.36 kΩ
1V
30 A*
2
75 to 250 V AC
45 to 65 Hz
300 A*
3
5 mA (when 200 V AC applied)
1.6 V
120 mA*4
400 A*
3
In one cycle at
60 Hz
at 60 Hz
at max.
carrying current
40 A*
2
Ta = Max. 40°C
104°F
AQR40A2-S-Z4/
6VDC
4 to 6V DC
Approx. 0.26 kΩ
AQR40A2-S-Z10/
18VDC
10 to 18V DC
Approx. 0.86 kΩ
AQR40A2-S-Z18/
28VDC
18 to 28V DC
Approx. 1.36 kΩ
Remarks
*
1
Load
side
Refer to REFERENCE DATA “3. Input current vs. input voltage”.
Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics
(at 20°C
68°F,
Input ripple: 1% or less)
Type
Item
Operate time, max.
Release time, max.
Insulation resistance, min., Initial
Breakdown voltage
Vibration
resistance
Shock
resistance
Functional
Destructive
Zero-cross type
Standard type
Reinforced type
1/2 cycle of voltage sine wave + 1 ms
1/2 cycle of voltage sine wave + 1 ms
100 M
Ω
between input, output and case
1,500 V AC between input, output and case
4,000 V AC between input, output and case
10 to 55 Hz at double amplitude of 2 mm*
10 to 55 Hz at double amplitude of 2 mm*
Min. 980 m/s
2
{100 G}
Min. 980 m/s
2
{100 G}
–20°C to +80°C
–4°F to +176°F
–25°C to +85°C
–13°F to +185°F
Zero-cross (Turn-ON and Turn-OFF)
Remarks
at 500V DC
For 1 min.
1 hour for X, Y, Z axes
10 minutes for X, Y, Z axes
5 time each for X, Y, Z axes
4 time each for X, Y, Z axes
Functional
Destructive
Ambient temperature
Storage temperature
Operational method
Note: *30A and 40A type is 10 to 55 Hz at double amplitude of 1.5 mm
.059 inch.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-R
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition:
With external heat sink
1) (1) 10 A, 15A, 20 A type
• A heat sink; optional heat sink (AQP-HS-
J10A) or a 150×150×3.2 mm aluminum
sheet (painted black)
(2) 30 A, 40 A type
Shown with standard heat sink (AQP-HS-30/
40A)
2) If attached to a heat sink, use a heat-
conductive compound or similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
(2) 15 A type
The graphs show the characteristics when the
relay is mounted as shown in the right figure.
3 mm or
greater
(1) 10 A type
;;;
;;;
;;;
;;;
;
;; ;
;;
;;
;
;;
;;
10
Load current, A
8
6
Hole for radiation
(40×35 mm)
Washers are added
to lift the relay.
With external
heat sink
Without external heat sink
4
2
0
–30
0
20
40
60
80
Ambient temperature
°C
(3) 20 A type
(4) 30 A type
50
20
Load current, A
16
15
12
Without external heat sink
8
7
6
4
2
0
–30
With external
heat sink
Load current, A
20
16
12
Without external heat sink
8
4
2
0
–30
Load current, A
With external
heat sink
40
With external
heat sink
30
20
Without external heat sink
10
0
20
40
60
80
Ambient temperature,
°C
0
20
40
60
80
Ambient temperature,
°C
0
–30
0
20
40
60
80
Ambient temperature,
°C
(5) 40 A type
50
2-1. Non-repetitive surge current vs. carrying
time (10 A type)
Non-repetitive surge current, A
220
200
180
160
140
120
100
80
60
40
20
0
2-2. Non-repetitive surge current vs. carrying
time (15 A type)
Non-repetitive surge current, A
220
200
180
160
140
120
100
80
60
40
20
0
40
Load current, A
With external
heat sink
30
20
Without external heat sink
10
0
–30
0
20
40
60
80
Ambient temperature,
°C
1
2
3 4 5 7 10
20 30 40 50 70 100
No. of cycles at 60 Hz
1
2
3 4 5 7 10
20 30 40 50 70 100
No. of cycles at 60 Hz
2-3. Non-repetitive surge current vs. carrying
time (20 A type)
Non-repetitive surge current, A
220
200
180
160
140
120
100
80
60
40
20
0
1
2
3 4 5 7 10
20 30 40 50 70 100
No. of cycles at 60 Hz
2-4. Non-repetitive surge current vs. carrying
time (30 A, 40 A type)
500
Non-repetitive surge current, A
3. Input current vs. input voltage
(10 A, 15 A, 20 A, 30 A, 40 A common)
30
25
Input current, mA
20
15
(18 to 28 V)
10
(4 to 6 V)
(10 to 18 V)
400
300
40A type
200
30A type
100
5
0
0
1
2 3 4 5 7 10 20 304050 70 100
No. of cycles at 60 Hz
0
5
10
20
15
Input voltage, V
25
30
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.