5100
SERIES
Toughened, weather resistant,
data displays with integral
USB 2.0 interface
These robust, monochrome displays are
ideal for use in exposed or industrial
environments. Bright white transflective
display technology is securely encased
within a sealed and impact resistant bezel.
The bezel features a hard coated UV and
scratch resistant, polycarbonate window.
Available in either 20 character x 4 line, 20 character x 8
line or 128 x 64 pixel graphic versions these USB 2.0
display devices can be easily installed into any control
panel or equipment enclosure.
The display assemblies can be specified with or without
three independently illuminated menu navigation keys.
Illumination is under software control (on/off/flashing).
Offered in eight different configurations/specifications,
Storm 5100 Series Displays are rated for use in either
Industrial (IND) or Extreme (EXM) environments. They
offer a ‘ready to use’ display solution for a wide range of
indoor or outdoor applications.
Performance
Operational key life:
>2 million cycles per key
0ºC to +60ºC
(optionally -20ºC to +70ºC)
-20ºC to +70ºC
5%RH to 95%RH
non-condensing
ETSI 300 019 5M3
(optionally 6M3)
IP54 (optionally IP65)
5J (optionally 10J)
50Mohms (min)
500V a.c. (60 secs)
5V
50mA
Environmental
Operational temperature:
102
Storage temperature:
Humidity:
Vibration and shock:
UV
Water and dust resistance:
Impact resistant:
102
All dimensions in mm
32
Electrical
Insulation resistance:
Breakdown voltage:
Max Operating voltage:
Max Operating current:
• Impact, shock and vibration resistant
• Sealed for use in wet or dirty environments
• Weather resistant for use in exposed locations
(optional feature)
• Extended operational temperature range -20ºC to +70ºC
(optional feature)
• Programmable USB display controller and system interface
• Display connects to the host system via a single USB cable
with a USB Mini-B connector (cable supplied separately)
• Resistant to petrochemicals, detergents and most
commonly used non-abrasive cleaning agents
• Responsive, illuminated menu navigation keys under
software control (on/off /flashing) (optional feature)
• Easy to use API with downloadable object code libraries
• USB 2.0 HID compliant device
Compliance
This device is designed to meet:
• EU RoHS
• EU Low Voltage Directive
• ESD: Up to +/- 15kV air discharge, +/- 7.5kV contact discharge
• WEEE Directive
• EMC-CE, FCC Part 15B Class B
• EN55022 Class B, EN60950, EN55024
Additional Information
(downloads available at www.storm-interface.com)
• Engineering Manual including product dimensions
and installation / configuration instructions
• CAD files (dxf, dwg)
• API Object code libraries
• Test data and reports
Accessories
• USB Cable for use with USB Interface
• Under panel fitting kit
5100
Configuration Utility Software for Storm
5100 Series Toughened USB 2.0 Data Displays
Storm 5100 Series Toughened Data Displays can be
configured by the Configuration Utility Software via the
Application Programming Interface for Windows (API).
These software tools are available free of charge and
can be downloaded from
www.storm-interface.com.
Please note: Registration is required for download.
SERIES
5100 (IND)
5100 (EXM)
Storm
5100 Series
character
display
Primary Features of the Configuration Utility
• Selection of font for 5100 Series character displays
Two standard fonts are available:
6 x 8. This provides 8 lines with 20 characters per line
6 x 16. This provides 4 lines with 20 characters per line
Each font includes the following character set:
!"#$%&'()*+,.\0123456789:;<=>?@ABCDEFGHIJKLMNOPQR
STUVWXYZ[/]^_'abcdefghijklmnopqstuvwxyz{|}~
There is also a large font numeric character set:
0123456789,.º±
• The 5100 Series graphic display is 128 x 64 pixels.
• Features supported by the Configuration Utility
and API include:
Integral display
backlight (on/off/flashing)
Illumination of three
navigation keys
(on/off/flashing)
Display contrast level
Flip (180° rotation)
Inverse (white on black)
• The utility will load up to four bitmap graphic icons
(maximum size 128 x 64 pixels). Any one icon can be set
as the default ‘power-up’ screen. Icons can be originated
using Microsoft Paint and previewed using the
Configuration Utility before loading to the display.
• The display enumerates as an HID compliant device.
Windows and Microsoft Paint are recognised trademarks of the Microsoft Corporation.
• USB
• 3 keys or
display only
• 4 or 8 line
x 20 characters
• IP54
• 0°C to 60°C
• 5J impact
• shock and vibration
IEC721-5M3
• USB
• 3 keys or
display only
• 4 or 8 line
x 20 characters
• IP65
• -20°C to 70°C
• 10J impact
• shock and vibration
IEC721-6M3
5100 (IND)
5100 (EXM)
Circle, rectangle
and line
Bar graph
Large font
Re-set to factory default
Firmware updates
Storm
5100 Series
graphic
display
• USB
• 3 keys or
display only
• 128 x 64 pixels
• IP54
• 0°C to 60°C
• 5J impact
• shock and vibration
IEC721-5M3
• USB
• 3 keys or
display only
• 128 x 64 pixels
• IP65
• -20°C to 70°C
• 10J impact
• shock and vibration
IEC721-6M3
Part Numbers
5100 (IND) – INDUSTRIAL
4 or 8 x 20 character display, 3 keys
128 x 64 pixel graphic display, 3 keys
4 or 8 x 20 character display, display only
128 x 64 pixel graphic display, display only
5103-000
5103-100
5100-000
5100-100
Accessories
USB Cable
(USB A to
90º USB mini-B)
Under panel
fitting kit
4500-01
For more information & to order:
5100-FK0
www.storm-interface.com
Whilst every effort
is made to ensure
details are correct
at time of print,
specifications are
subject to change
without notice.
5100 (EXM) – EXTREME
4 or 8 x 20 character display, 3 keys
128 x 64 pixel graphic display, 3 keys
4 or 8 x 20 character display, display only
128 x 64 pixel graphic display, display only
5103-010
5103-110
5100-010
5100-110
Storm Interface products include technology
protected by international patents and
design registration. All rights reserved.
Storm is a trademark of
Keymat Technology Ltd
Storm Interface is a
trading name of Keymat
Technology Ltd
003
Designed & produced
by
NIK Design
nik@nikdesign.co.uk
5100 Jan 2014
FM 39602