UL (60950-1) reinforced
insulation compliant
AQ-J
∗
Compact high capacity,
(25A max)
Slim heat sink combined
type added
AQ-J RELAYS
TYPICAL APPLICATIONS
1. Kitchen appliances
2. Vending machine
3. Injection molding machine
4. Packing machine
5. Amusement machine
FEATURES
New
1. Compact Size
Approx 40% reduction in required space
achieved in the footprint area compared
with the previous model (AQ-R relay)
2. Built-in varistor
3. Reverse input connection
prevention function
4. Labor Saving (tab terminal)
5. Heat sink combined types ready to
mount on DIN rail added (Radiating
grease and screws assembly process
not needed)
6. Output arrangement 1a and 1a
×
2
available in the heat sink combined
type
Note: * International standards are acquired for
AQ-J SSR stand-alone, not applied to heat
sink combined type.
Slim heat sink combined type
Compliance with RoHS Directive
ORDERING INFORMATION
AQJ
AQ-J Solid State Relays
Output type
1: 10A, 75V to 264V AC
2: 15A, 75V to 264V AC
4: 25A, 75V to 264V AC
Terminal
1: Plug-in terminal, Zero-cross
2: Plug-in terminal, Random*
Input voltage
2: 4 to 6 V DC
6: 18 to 28 V DC
9: 10 to 18 V DC
Functions
V: Built-in varistor
Slim heat sink combined type
None: Without a heat sink
Y:
1a type
W:
1a
×
2 type
Note: * Random type is available by custom order.
TYPES
1. AQ-J Solid State Relays
Type
Load current
10A
Load voltage
Input voltage
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
Part No.
AQJ112V
AQJ119V
AQJ116V
AQJ212V
AQJ219V
AQJ216V
AQJ412V
AQJ419V
AQJ416V
Zero-cross*
15A
75V to 264V AC
25A
Standard Packing; carton: 10 pcs., case: 200 pcs.
Note: * Random type also available. Please inquire.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-J
2. AQ-J SSR Slim Heat Sink Combined Type
Output configuration
Type
Load current
10A
1a
20A
Zero-cross*
10A
(per 1a)
1a
×
2
15A
(per 1a)
Standard Packing; no carton, case: 10 pcs.
Note: * Random type also available. Please inquire.
75V to 264V AC
Load voltage
Input voltage
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
4 to 6V DC
10 to 18V DC
18 to 28V DC
Part No.
AQJ112VY
AQJ119VY
AQJ116VY
AQJ412VY
AQJ419VY
AQJ416VY
AQJ112VW
AQJ119VW
AQJ116VW
AQJ412VW
AQJ419VW
AQJ416VW
3. Accessories
Type
Slim heat sink (28mm wide) (Mountable on a DIN rail)
Slim heat sink (45mm wide) (Mountable on a DIN rail)
Standard heat sink (10A and 15A)
Standard heat sink (25A only)
DIN rail mounting plate
Part No.
AQP-HS-SJ10A
AQP-HS-SJ20A
AQP-HS-J10A
AQP-HS-J25A
AQP-DPJ
Packaged quantity
No carton, 10 in a case
No carton, 8 in a case
5 in a carton, 20 in a case
No carton, 5 in a case
5 in a carton, 50 in a case
SPECIFICATIONS
1. Ratings (Test sample: AQ-J stand-alone, Measurement condition: at 20°C
68°F,
input ripple: 1% or less)
1) Input side
Part No.
Item
Rated voltage
Input voltage
Input impedance
Drop-out voltage
AQJ112V
AQJ212V
AQJ412V
5V DC
4 to 6V DC
Approx. 0.26kΩ
AQJ119V
AQJ219V
AQJ419V
12V DC
10 to 18V DC
Approx. 0.8kΩ
Min. 1V DC
AQJ116V
AQJ216V
AQJ416V
24V DC
18 to 28V DC
Approx. 1.6kΩ
2) Output side
Part No.
Item
Max. load current*
1
Load voltage
Frequency
Non-repetitive surge current
Max. “OFF-state” leakage current
Max. “ON-state” voltage drop
Min. load current*
2
AQJ112V
AQJ119V
AQJ116V
10A
AQJ212V
AQJ219V
AQJ216V
15A
75 to 264V AC
45Hz to 65Hz
150A
Max. 5mA
Max. 1.6V
50mA
AQJ412V
AQJ419V
AQJ416V
25A
100A
250A
Notes: *1 Refer to REFERENCE DATA “1. Load current vs. ambient temperature” .
*2 When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Ratings (Test sample: AQ-J slim heat sink combined type, Measurement condition: at 20°C
68°F,
input ripple: 1 % or less)
1) Input side
Part No.
Item
Rated voltage
Input voltage
Input impedance
Drop-out voltage
AQJ112V(Y·W)
AQJ412V(Y·W)
5V DC
4 to 6V DC
Approx. 0.26kΩ
AQJ119V(Y·W)
AQJ419V(Y·W)
12V DC
10 to 18V DC
Approx. 0.8kΩ
Min. 1V DC
AQJ116V(Y·W)
AQJ416V(Y·W)
24V DC
18 to 28V DC
Approx. 1.6kΩ
2) Output side
Part No.
Item
Output arrangement
Max. load current*
1
Load voltage
Frequency
Non-repetitive surge current
Max. “OFF-state” leakage current
Max. “ON-state” voltage drop
Min. load current*
2
AQJ112VY
AQJ119VY
AQJ116VY
1a
10A
20A
75 to 264V AC
45Hz to 65Hz
100A
250A
Max. 5mA
Max. 1.6V
50mA
100A
250A
10A
AQJ412VY
AQJ419VY
AQJ416VY
AQJ112VW
AQJ119VW
AQJ116VW
1a
×
2
15A
AQJ412VW
AQJ419VW
AQJ416VW
Notes: *1 Refer to REFERENCE DATA “1. Load current vs. ambient temperature” .
*2 When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-J
3. Characteristics (Measurement condition: at 20°C
68°F,
input ripple: 1% or less)
Item
Operate time, max.
Release time, max.
Insulation resistance, min.
Breakdown voltage
Vibration resistance
Shock resistance
Ambient temperature
Storage temperature
Operational method
Characteristics
1/2 cycle of voltage sine wave + 1ms
1/2 cycle of voltage sine wave + 1ms
100MΩ between input, output and case
3,000 Vrms between input and output
2,500 Vrms between input, output and case
SSR stand-alone: 10 to 55Hz, double amplitude of 1.5mm
Slim heat sink combined type: 10 to 55Hz, double amplitude of 0.75mm
SSR stand-alone: Min. 980m/s
2
Slim heat sink combined type: Min. 197m/s
2
–30 to +80°C
–22 to +176°F
–30 to +100°C
–22 to +212°F
Zero-cross (Turn ON and Turn OFF)
Remarks
at 500 V DC
for 1min.
X, Y, Z axes
X, Y, Z axes
Non-condensing at low temperatures
REFERENCE DATA
(1) AQ-J Solid State Relays
1. Load current vs. ambient temperature Use load current within range specified in the figure below
Tested condition:
1) If attached to a heat sink, use a heat
conductive compound (Ex. Toshiba sillicone
YG6111 or TSK5303) of similar coating to
improve cooling
2) Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
3) The current value is per 1a.
(A) slim heat sink
(B) slim heat sink
(C) standard heat sink
(D) DIN rail mounting plate
(E) standard heat sink
AQP-HS-SJ20A
AQP-HS-SJ10A
AQP-HS-J10A
AQP-DPJ
AQP-HS-J25A
(1) 10 A type (when using heat sink or iron
plate)
12
10
Load current, A
8
When a single unit is mounted on an (A) slim heat sink
When a single unit is mounted
on an (B) slim heat sink
(2)-1. 15 A type (when using iron plate)
18
15
Load current, A
12
When using
9 100
×
100
×
t1.6 mm
iron plate
6
When using
150
×
150
×
t1.6 mm
iron plate
When using 200
×
200
×
t2 mm iron plate
When two units are mounted
on an (A) slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When two units are mounted
6
on an (B) slim heat sink
When using 100×100×t1.6 mm iron plate
4
2
0
When using as stand-alone
When using an (D) DIN rail mounting plate
3
0
-20
0
20
40
60
80
Ambient temperature,
°C
100
0
20
40
60
80
Ambient temperature,
°C
(2)-2. 15 A type (when using a heat sink)
20
When a single unit is mounted When a single unit
is mounted on an
on an (C) standard heat sink
When a single unit is mounted (A) slim heat sink
on an (B) slim heat sink
(3)-1. 25 A type (when using iron plate)
30
25
Load current, A
20
15
10
5
0
-20
When using 300
×
300
×
t2 mm iron plate
(3)-2. 25 A type (when using a heat sink)
30
25
Load current, A
20
15
When a single unit is
mounted on an (E)
standard heat sink
When a single unit is mounted
on an (C) standard heat sink
When a single unit is
mounted on an (A)
slim heat sink
Load current, A
15
When using 250
×
250
×
t2 mm
iron plate
When using
200
×
200
×
t2 mm
iron plate
10
When two units are mounted
on an (A) slim heat sink
When two units are mounted
on an (B) slim heat sink
5
When using as stand-alone
When using an (D) DIN rail mounting plate
When using 150
×
150
×
t1.6 mm
iron plate
When using 100
×
100
×
t1.6 mm
iron plate
0
20
40
60
80
Ambient temperature,
°C
When a single
unit is mounted on an
(B) slim heat sink
10
When two units are
mounted on an (A)
slim heat sink
5
0
When two units
are mounted on an
(B) slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
0
0
20
40
60
80
Ambient temperature,
°C
100
0
20
40
60
80
Ambient temperature,
°C
100
2. Non-repetitive surge current vs.
carrying time
300
Non-repetitive surge current, A
3. Input current vs. input voltage
characteristics
(10A, 15A and 25A common)
30
(4 to 6V DC)
25
(10 to 18V DC)
25A type
200
15A type
10A type
100
Input current, mA
20
15
10
5
(18 to 28V DC)
0
1
10
No. of cycles at 60 Hz
100
0
5
10
15
20
25
Input voltage, V
30
35
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-J
(2) AQ-J SSR Slim Heat Sink Combined Type
1. Load current vs. ambient temperature Use load current within range specified in the figure below
(1) Output arrangement: 1a
25
(2) Output arrangement: 1a
×
2
20
(Per 1a)
20
Load current, A
AQJ41∗VY
Load current, A
15
AQJ41∗VW
10
AQJ11∗VW
5
15
10
AQJ11∗VY
5
0
0
20
40
60
80
Ambient temperature,
°C
100
0
0
20
40
60
80
Ambient temperature,
°C
100
Note:
When two contacts are operated simultaneously.
In the case of a single-contact operation, the rating of
(1) AQJ11∗VY, AQJ41∗VY applies.
2. Surge current vs. carrying time
500
3. Input current vs. input voltage
characteristics
30
AQJ∗12V∗
AQJ∗19V∗
Input current, mA
400
Surge current, A
24
AQJ∗16V∗
18
300
200
AQJ41∗V∗
100
AQJ11∗V∗
0
1
10
No. of cycles at 60 Hz
100
12
6
0
0
5
10
15
20
Input voltage, V
25
30
DIMENSIONS
(mm
inch)
1. AQ-J Stand Alone
CAD Data
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://panasonic-electric-works.net/ac
External dimensions
30 max.
7.95
1.181 max.
.313
4.55
.179
8.4 6.35
.331 .250
38
1.496
30
1.181
2-1.65 dia.
2-.065 dia.
2-1.2 dia.
2-.047 dia.
Input power
source
3
Schematic
+
−
1
Load
Load power
source
4.3
.169
4
2
Mounting dimensions
30
+0.2
−0.1
1.181
+.008
−.004
4.3 dia.
.169 dia.
5.5 2.8
.217 .110
1.6
.063
28
1.102
7.1
.280
2-4.3 dia. or M4
2-.169 dia. or M4
Output side
1
and
2
terminals: #250 type, t = 0.8
.031
Input side
3
and
4
terminals: #110 type, t = 0.5
.020
17
.669
5
.197
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-J
2.-(1) Slim Heat Sink Combined Type
Output Arrangement: 1a
CAD Data
External dimensions
100
3.937
90
3.543
78
3.071
6
.236
4.6 dia. 4.6×5.6 elliptical hole
.181×.220
.181 dia.
28
1.102
Input power
source
+
−
3
Schematic
1
Load
Load power
source
4
2
Mounting dimensions (Top view)
83
3.268
Max.
113
4.449
2-4.6 dia. or M4
2-.181 dia. or M4
6
.236
90±0.2
3.543±.008
100
3.937
1.6
.063
AQP810
70707
Note: When using on a DIN rail, please install
so that the “A” part is on top.
“A” part
2.-(2) Slim Heat Sink Combined Type
Output Arrangement: 1a
×
2
CAD Data
External dimensions
100
3.937
90
3.543
78
3.071
6
.236
4.6 dia. 4.6×5.6 elliptical hole
.181 dia.
.181×.220
28
1.102
Input power
source
+
−
3
Schematic
1
Load
Load power
source
4
2
Note: Use caution for AQ-J terminal
numbers.
Mounting dimensions (Top view)
83
3.268
Max.
113
4.449
2-4.6 dia. or M4
2-.181 dia. or M4
6
.236
90±0.2
3.543±.008
100
3.937
1.6
.063
AQP810
70707
Note: When using on a DIN rail, please install
so that the “A” part is on top.
“A” part
ACCESSORIES
AQP-HS-SJ10A Slim Heat Sink
CAD Data
External dimensions
100
3.937
90
3.543
78
3.071
30
1.181
5-M4
(Effective screw depth: 6mm
.236inch)
6
.236
4.6×5.6 elliptical hole
28
.181×.220
1.102
Mounting dimensions (Top view)
2-4.6 dia. or M4
2-.181 dia. or M4
6
.236
90±0.2
3.543±.008
4.6 dia.
.181 dia.
30
30
1.181
10
1.181
.394
78
3.071
1.6
.063
83
3.268
AQP810
70707
Note: When using on a DIN rail, please install
so that the “A” part is on top.
“A” part
AQP-HS-SJ20A Slim Heat Sink
CAD Data
100
90
78
40
External dimensions
3.937
3.543
3.071
1.575
Mounting dimensions (Top view)
2-4.6 dia. or M4
2-.181 dia. or M4
5-M4
(Effective screw depth: 6mm
.236inch)
30
6
.236 1.181
90±0.2
3.543±.008
6
.236
4.6 dia.
.181 dia.
47.6
1.874
30
1.181
4.6×5.6 elliptical hole
.181×.220
45
1.772
78
3.071
1.6
.063
83
3.268
AQP812
70707
Note: When using on a DIN rail, please install
so that the “A” part is on top.
“A” part