conversion gain of 12 dB, and an image rejection of
15 dBc. This up-converter includes a LO doubler,
LO buffer amplifier, and RF buffer amplifier. Variable
gain can be achieved by adjusting the bias, with
turn-down trajectories optimized to maintain linearity
and 2LO leakage over the gain control range. The
output IP3 is 32 dBm at maximum gain.
The MAUC-011003 is ideally suited for 28 and 32
GHz band point-to-point radios under both LSB and
USB operation and Ka-Band VSAT applications.
Each device is 100%
performance compliance.
RF tested to ensure
13
11
12
8
9
10
GND LO GND N/C N/C VG3
Pin Configuration
2
Pin No.
1
2
3
4
5
6
Function
N/C
I*
I
Q
Q*
N/C
GND
LO
GND
N/C
N/C
VG3
Pin No.
13
14
15
16
17
18
19
20
21
22
23
24
25
Function
VD3
VG4
VG1
VD1
VG2
VD2
GND
RF
GND
N/C
N/C
N/C
Paddle
3
Ordering Information
Part Number
MAUC-011003-TR0500
MAUC-011003-001SMB
1
7
Package
500 Piece Reel
Sample Board
8
9
10
11
12
1. Reference Application Note M513 for reel size information.
2. For optimum RF performance, all N/C’s should be terminated
to ground.
3. The exposed pad centered on the package bottom must be
connected to RF, DC and thermal ground.
1
^ Restrictions on Hazardous Substances, European Union Directive 2011/65/EU.
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macomtech.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAUC-011003
Up Converter
27.5 - 33.4 GHz
Electrical Specifications: LO = 0 dBm, IF = -10 dBm @ 2 GHz,
V
D
1,2
4
= 4 V, V
D
3
4
= 3 V, I
D
1 +I
D
2 = 240 mA, I
D
3 = 140 mA, V
G
4 = -3 V, T
A
= 25°C
Parameter
Frequency Range (RF)
Frequency Range (LO)
LO Input Power (PLO)
Conversion Gain
Image Rejection
Input IP3
Output IP3 (P
IN
= -10 dBm/tone)
Spurious (2xLO) [tuned - IF voltages ~ 0.2 V]
Spurious (1xLO)
Gate Voltages (V
G
1,V
G
2,V
G
3)
4
Gate Current (I
G
1 + I
G
2)
Gate Current (I
G
3)
Units
GHz
GHz
dBm
dB
dBc
dBm
dBm
dBm
dBm
V
mA
mA
Min.
27.5
12
-
8.5
-
-
28
-
-
-1.0
-2.0
-0.5
Typ.
-
-
0
12.0
15
20
32
-45
-55
-
-
-
Max.
33.4
18.45
-
14.0
-
-
-
-
-
-0.1
0
0
Rev. V1
4. Apply gate voltages prior to drain voltages. First turn on V
G
4 = -3 V. Then adjust V
G
1, V
G
2 and V
G
3 between -1.0 and -0.1 V to achieve
specified drain current. Typical current (380 mA) = 240 (I
D
1 + I
D
2) + 140 (I
D
3) . Refer to App Note [1] for biasing details.
Absolute Maximum Ratings
5,6,7
Parameter
Drain Voltage
Gate Bias Voltage (V
G
1,2,3)
Gate Bias Voltage (V
G
4)
Input Power
LO Input Power
Storage Temperature
Operating Temperature
Junction Temperature
Absolute Max.
4.3 V
-1.5 V < V
G
< 0 V
-4.0 V < V
G
< 0 V
10 dBm
13 dBm
-55°C to +150°C
-40°C to +85°C
+150°C
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
These electronic devices are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity. Proper ESD control techniques
should be used when handling these static
sensitive devices.
5. Exceeding any one or combination of these limits may cause
permanent damage to this device.
6. MACOM does not recommend sustained operation near
these survivability limits.
7.
Operating at nominal conditions with T
J
≤ +150°C will ensure
MTTF > 1 x 10
6
hours.
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macomtech.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAUC-011003
Up Converter
27.5 - 33.4 GHz
Typical Performance Curves: LO = 0 dBm, IF = -10 dBm @ 2 GHz, P
DC
= 1.38 W
Conversion Gain
20
Rev. V1
Conversion Gain (dB)
15
10
5
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
0
27
28
29
30
31
32
33
34
Frequency (GHz)
Conversion Gain @ 27.5 GHz
20
15
Conversion Gain @ 33.5 GHz
20
15
Conversion Gain (dB)
5
0
-5
-10
-15
-20
0
40
80
120
160
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
Conversion Gain (dB)
10
10
5
0
-5
-10
-15
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
200
240
-20
0
40
80
120
160
200
240
ID1 + ID2 (mA)
ID1 + ID2 (mA)
Conversion Gain @ 27.5 GHz
20
15
Conversion Gain @ 33.5 GHz
20
15
Conversion Gain (dB)
10
5
0
-5
-10
-15
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
Conversion Gain (dB)
10
5
0
-5
-10
-15
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
40
60
80
100
120
140
160
40
60
80
100
120
140
160
3
ID3 (mA)
ID3 (mA)
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macomtech.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAUC-011003
Up Converter
27.5 - 33.4 GHz
Typical Performance Curves: LO = 0 dBm, IF = -10 dBm @ 2 GHz, P
DC
= 1.38 W
Input IP3
30
25
20
Rev. V1
IIP3 (dBm)
15
10
5
0
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
27
28
29
30
31
32
33
34
Frequency (GHz)
Input IP3 @ 27.5 GHz
25
Input IP3 @ 33.5 GHz
25
20
20
IP3 (dBm)
10
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
IP3 (dBm)
15
15
10
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
5
5
0
0
40
80
120
160
200
240
0
0
40
80
120
160
200
240
ID1 + ID2 (mA)
ID1 + ID2 (mA)
Input IP3 @ 27.5 GHz
25
Input IP3 @ 33.5 GHz
25
20
20
IP3 (dBm)
10
IP3 (dBm)
15
15
5
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
10
5
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
0
40
60
80
100
120
140
160
0
40
60
80
100
120
140
160
4
ID3 (mA)
ID3 (mA)
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macomtech.com
for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
MAUC-011003
Up Converter
27.5 - 33.4 GHz
Typical Performance Curves: LO = 0 dBm, IF = -10 dBm @ 2 GHz, P
DC
= 1.38 W
2xLO Leakage
-10
-20
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
Rev. V1
1xLO Leakage
-10
-20
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
2xLO Leakage (dBm)
-30
-40
-50
-60
-70
-80
1xLO Leakage (dBm)
34
-30
-40
-50
-60
-70
-80
27
28
29
30
31
32
33
27
28
29
30
31
32
33
34
Frequency (GHz)
Frequency (GHz)
Image Rejection
0
-10
Image Rejection (dBc)
-20
-30
-40
-50
-60
LSB = +25°C
USB = +25°C
LSB = -40°C
USB = -40°C
LSB = +85°C
USB = +85°C
27
28
29
30
31
32
33
34
Frequency (GHz)
5
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
www.macomtech.com
for additional data sheets and product information.