Ti125, Ti110, Ti105, Ti100, Ti95
and Ti90 Industrial-Commercial
Infrared Cameras
Technical Data
Now compatible with Fluke
Connect
™
Mobile App
Rugged and reliable
troubleshooting infrared cameras
A Fluke infrared camera can save you time
and money by finding potential problems
before they become costly failures. Indus-
trial professionals bring Fluke infrared
cameras to the job because they do the job.
Over 65 years of industrial experience give
Fluke infrared tools the level of performance
needed to keep you up and running. With the
innovative features and functionality in the
Fluke Ti125, Ti110, Ti105, Ti100, Ti95 and
Ti90 infrared cameras, you can perform infra-
red inspections faster and more efficiently.
•
The combination of great resolution with
an optimized field of view provides brilliant
detail and ensures quality images captured
from a safe distance.
•
Exclusive IR-OptiFlex
™
focus system –
ensures that images are in good focus from
1.2 meters (4 feet) and beyond for optimum
image clarity and scanning convenience. For
shorter distances change to manual mode
with the touch of a finger (Ti110 and Ti125).
•
Entire line up of infrared cameras is compat-
ible to Fluke Connect
™
– the largest network
for wirelessly enabled tools.
•
Find problems faster and easier with Fluke
IR-Fusion
®
technology (Ti125, Ti110, Ti105).
Accurately identify potential issues by com-
bining digital and IR images.
•
Get further clarification with AutoBlend
™
mode – the blending of a digital and partially
transparent IR image into a single informa-
tion-filled image
•
Multi-mode video recording – focus-free
video in visible light and infrared with full
IR-Fusion (Ti110 and Ti125 only).
Spend less time finding problems and more
time solving them with the innovative,
rugged and easy-to-use Ti125, Ti110, Ti105,
Ti100, Ti95 and Ti90 infrared cameras.
Ti110
Ti125
Ti105
Ti100
Ti95
Ti90
Patented Fluke IR-Fusion
®
Technology
Enjoy the industry’s only point-and-shoot IR-Fusion camera. Fluke pat-
ented technology provides the user with both a digital and an infrared
image in one to precisely document problem areas.
IR-OptiFlex
™
focus system
Scan for issues significantly faster than before with
Fluke’s revolutionary, ultra-rugged focus system. The IR-OptiFlex focus
system gives you optimum focus by combining focus-free, ease-of-use
with the flexibility of manual focus on the same camera.
Built with
See it. Save it. Share it.
All the facts, right in the field.
Fluke Connect with ShareLive
™
video call is the only wireless mea-
surement system that lets you stay in contact with your entire team
without leaving the field. The Fluke Connect mobile app is avail-
able for Android
™
and iOS and works with over 20 different Fluke
products—the largest suite of connected test tools in the world. And
more is on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all
temperature, mechanical, electrical and vibration measurements
for each equipment asset in one place. Get started saving time and
increasing your productivity.
Download the app at:
Smart phone not included with purchase.
Detailed specifications
Ti125
IR resolution
LCD display
Focus mechanism
IR-Fusion
®
technology
Ti110
Ti105
Ti100
Ti95
80 x 80 uncooled
microbolometer
Ti90
80 x 60 uncooled
microbolometer
160 x 120 uncooled microbolometer
3.5 inch diagonal (portrait format)
Focus-free 1.2 m (4 ft) and beyond
PIP (1.2 m (4 ft) to 4.6
m (15 ft)), FULL IR, FULL
VISIBLE
No, full IR only
IR-OptiFlex™ focus system
PIP, FULL IR, FULL VISIBLE,
AutoBlend™
PIP, FULL IR, FULL VISIBLE
Focus-free 0.6 m (2 ft) and beyond
PIP (1.2 m (4 ft) to
4.6 m (15 ft)), FULL
IR, FULL VISIBLE
26 °H x 26 °V
FULL IR, FULL
VISIBLE
Visible camera
FOV (Field of view)
IFOV (Spatial resolution)
Capture of refresh rate
NETD (thermal sensitivity)
Level and span control
Minimum span in auto mode
Minimum span in manual mode
Standard palettes
2 megapixel industrial-grade
22.5 °H x 31 °V
3.39 mRad
9 Hz or 30 Hz versions
≤ 0.10 °C at 30 °C target temp (100 mK) Filtered mode
to get to 80 mK
None - IR Only
2 megapixel industrial-grade
19.5 °H x 26 °V
5.6 mRad
9 Hz only
≤ 0.10 °C at 30 °C target temp (100 mK)
Manual and auto
5 °C
2.5 °C
Blue-red, grayscale, invert-
ed grayscale, high-contrast,
hot metal, ironbow, amber
Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Hot Metal, Ironbow, Amber, Inverted Amber
Blue-Red, Iron-
bow, Grayscale,
Amber
Blue-red,
grayscale, high-
contrast, hot
metal, ironbow,
amber
Blue-red,
grayscale,
ironbow
Ultra Contrast
™
palettes
Blue-Red, Grayscale, Invert-
edGrayscale, High-contrast,
Hot Metal, Ironbow, Amber,
Inverted Amber
-20 °C to +350 °C (-4 °F to
+662 °F)
Blue-Red, Grayscale,
Ironbow
None
Temperature measurement
Temperature measurement range (not
calibrated below -10 °C)
Temperature measurement
accuracy
Centerpoint temperature measurement
Centerbox (Min/Avg/Max)
Emissivity correction
Transmission correction
Background (reflected) compensation
Spectral band
Analysis, documentation and reporting
SmartView
®
Software
Fluke Connect
™
compatible
Fluke Connect
™
WiFi SD Card included
IR-PhotoNotes
™
annotation system
Voice annotation (audio)
Multi-mode video output
-20 °C to +250 °C (-4 °F to +482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Yes
Yes
Yes
None
No
Yes
7.5 µm to 14 µm (long wave)
Included
Yes
9 µm to 15 µm (long wave)
Yes
None
Yes
Yes
Yes (3 images)
Yes (60 seconds) per image
Streaming USB video output
(infrared, visible and IR-
Fusion modes)
Yes (AVI with MPEG encod-
ing, up to 5 minutes)
Yes, radiometric .is3 for
approximx 2.5 to 5 minutes
depending upon thermal
scene
Thumbnail review
High temperature, low
High temperature, low
High temperature
temperature, isotherm
temperature
Yes
None
Three on camera and in SmartView
®
Yes
Yes
2 meter (6.5 feet)
IP54
Two-years
Yes
Two
Yes
One
4+ hours (each)*
Optional (accessory)
Yes
No
None
No
None
Multi model video redording (standard avi
w/ mpeg encording)
Multi-mode video recording (radiometric
.is3)
None
None
Memory review
Troubleshooting features
Color alarms
Hot/cold markers
User definable spot markers
Laser pointer
Torch
Built to last
Drop test
Ingress protection (IP) rating (IEC 60529)
Standard warranty period
Extended warranty and service plans
Smart battery technology
Battery (field-replaceable, rechargeable)
Battery life
External battery charging base
Charging power supply
None
Yes
None
None
None
2 Fluke Corporation
Ti125, Ti110, Ti105, Ti100, Ti95 and Ti90 Industrial-Commercial Infrared Cameras
Ti125
Other specifications
Weight
Size
Minimum IR focus distance
Minimum parallax
Recommended Calibration cycle
Multifunction card reader
Memory storage
Operating temperature range
Storage temperature range
Operating humidity
Vibration and shock
Safety standards
C Tick
EMI, RFI, EMC
Users manuals
Ti110
Ti105
Ti100
Ti95
Ti90
0.726 kg (1.6 lb)
28.4 cm x 8.6 cm x 13.5 cm (11.2 in x 3.4 in x 5.3 in)
15.25 cm (6 in)
122 cm (48 in)
~45.7 – 55.9 cm (~ 18 in – 22 in)
~122 cm (48 in)
None - IR Only
~45.7 cm (18 in)
Two years
Included
Optional (accessory)
2 GB WiFi SD memory card
2 GB SD memory card
-10 °C to +50 °C (14 °F to 122 °F)
-10 °C to +50 °C (14 °F to 122 °F)
Operating and storage 10 % to 95 %, non-condensing
2G, IEC 68-2-26 and 25G, IEC 68-2-29
CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
IEC/EN 61326-1
EN61326-1; FCC Part 5
Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish,
Traditional Chinese, Turkish, Dutch, and Hungarian
Ordering information
FLK-Ti125 30HZ
Industrial-Commercial Thermal Imager
FLK-Ti125 9HZ
Industrial-Commercial Thermal Imager
FLK-Ti110 30HZ
Industrial-Commercial Thermal Imager
FLK-Ti110 9HZ
Industrial-Commercial Thermal Imager
FLK-Ti105 30Hz
Industrial-Commercial Thermal Imager
FLK-Ti105 9HZ
Industrial-Commercial Thermal Imager
FLK-Ti100 9HZ
General Use Thermal Imager
FLK-Ti95 9HZ
General Use Thermal Imager
FLK-Ti90 9HZ
General Use Thermal Imager
Included with product
Thermal imagers are shipped with ac power adapter, lithium ion smart battery
(Ti125 includes 2 each—other models 1 each), USB cable, SD memory card
(Fluke Connect WiFI SD Card for Ti125 and Ti110 only), hard carrying case,
soft transport bag, adjustable hand strap (except Ti90), printed users manual
in English, Spanish, French, German and Simplified Chinese, others on CD,
SmartView® software and warranty registration card. Ti125 model also
include a two-bay charging base and a multi-format USB memory card reader.
Optional
FLK-TI-VISOR2
Sun visor
FLK-TI-TRIPOD2
Tripod mounting accessory
BOOK-ITP
Introduction to Thermography Principles Book
FLK-TI-SBC3
External charging base and power supply
FLK-TI-SBP3
Extra lithium-ion rechargeable smart battery
TI-CAR CHARGER
Thermal imager vehicle charger
Fluke Connect Kits
FLK-TI125 30HZ/FCB
Ti125 Thermal Imager, 3000FC DMM,
a3001FC iFlex Module
FLK-TI105 30HZ/FCA
Ti105 Thermal Imager, 3000FC DMM,
a3001FC iFlex Module
FLK-TI95 9HZ/FCA
Ti95 IR Camera with DMM a3001 FC iFlex Kit
FLK-TI95 9HZ/FCC
Ti95 IR Camera with 3 a3001 iFLEX 805 FC Kit
Fluke Connect modules
FLK-a3000FC
AC Current Clamp Module
FLK-a3001FC
iFlex
™
AC Current Clamp Module
FLK-a3002FC
AC/DC Current Module
FLK-v3000FC
AC Voltage Module
FLK-v3001FC
DC Voltage Module
FLK-t3000FC
K-Type Temperature Module
FLK-FC-SD CARD
Fluke Connect Wireless SD Card
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012-2014 Fluke Corporation. Specifications subject to
change without notice. Printed in U.S.A. 2/2014 4026524F_EN
Modification of this document is not permitted without
written permission from Fluke Corporation.
3 Fluke Corporation
Cameras