229-2 Leakage
Current Tester
AC Current Leakage Tester
Small leakage currents can be dangerous! The current above the
"threshold of perception" in appliances, motors and other equipment
can cause a violent reaction which may result in serious physical injury.
For service, lab, production or industry, the Model 229-2 helps determine
product conformance to standards.
CAUTION!
Leakage current in appliances may increase with use and
aging. Check appliances periodically for safety.
• Designed around ANSI C39.5 requirement for the
measurement of AC leakage current and UL Safety
Standards.
• Compensated to Approximate Dalziel's Perception Curve
• Overload protected Up to 500 V Peak Momentarily on all
ranges
• Checks both 120 VAC and 240 VAC appliances
• Includes Test Leads, Battery and Manual
Carrying Case accomodates
the Tester, Test Leads and
Operators Manual
1
Rev. 07-17
229-2 Leakage
Current Tester
Ordering Information
Leakage Tester
229-2 Leakage Current
Tester
Accessories
Probe Leads w/Screw-On Alligator Clips
Probe set, replaceable tip, banana plug
Clip set, alligator, screw on
Lead set, alligator,
banana plug
Case,
Yellow
Padded Nylon
Case, Black Padded Nylon
Case, Molded Plastic
Catalog Number
12267
Catalog Number
00125
07538
00425
07500
00832
00834
45028
Ranges
AC current:
AC voltage:
Battery Test
Short Test
Resolution
Accuracy
Input Impedance
Input Resistance
Accuracy Vs. Frequency
Battery Life
Rated Circuit to Ground Voltage
Reference Conditions
Overload Protection
Size
Weight
Battery
0.3-1-3-10 mA
0-150 and 0-300 volts
Replace-Good
Red Arc: 30 mA FS, Green arc: 10 mA or less
5µA on 0.3 mA range
±3% Full Scale at 60 Hz
For current tests, 1.5KΏ in parallel with 0.15µF
0.5 MΏ for 150V Range, 1.0 MΏ for the 300V range
Approximates Dalziel's "Percentile 50 Threshold of Perception Curve" within
±1.0 dB
Approximately 200 hours
300Vrms
23C ±1C, 30% to 60% Relative Humidity
Up to 500V peak momentary on all ranges
7" x 5-1/4" x 3-1/8"
3 Ibs. (1.4 Kg)
One 9V NEDA No. 13F, 1604A
(Burgess Type
PM-6 or Equivalent)
The input network utilized in the M229-2 is detailed in Figure 1 on Page 3 of the manual.
2