Ultra High Sensitivity Gateable Photon Counting Module
Description
The Photon Counting Head MP 900 series is designed for applications in all fields of single photon
detection, e.g. chemoluminescence, bioluminescence, in-vitro assay, environmental measurements
or pure research. It is an easy to use module, containing the Channel Photomultiplier, a high voltage
power supply, a discrimination amplifier and a pulse shaper for fast output pulses. An installed active
quenching systems avoids over-illumination to the detector. It is also possible to apply an external gate
function for time correlated photon counting. Strong variations in light levels are possible due to the high
dynamic range of the installed CPM. The exceptional low noise and high sensitivity facilitates detection
of extremely low light levels.
EVERYTHING
IN A
NEW
LIGHT.
Features
• Very low noise, typical 10 cps,
• High dynamic range up to 6 orders of magnitude
• High reliability
• No cooling requirement
• Very high stability in noise level, no sudden "bursts"
• High stability over time
• Rugged and compact design
• Gateable CPM input for time resolved measurements
• Active quenching circuit for high light protection
• Extremely fast high light recovery times
• 5 volts supply voltage
MP 900
Specification *)
Detector
Detector type
Model *)
Installed CPM type
Photocathode diameter
Photocathode material
Window material
Spectral response / nm
Quantum efficiency
Dark counts (typ.)
P Version
Model
Installed CPM type
Dark counts (typ.)
*) Additional models on request
CPM-Channel Photomultiplier
MP 942
C 942 P
Bialkali
Quartz
165-650
10 cps
MP 943
C 943 P
Bialkali
UV-glass
185-650
10 cps
MP 944
C 944 P
min. 5 mm
Bialkali
Boro
300-650
20% typical
10 cps
MP 952
C 952 P
Multialkali
Quartz
165-750
50 cps
MP 962
C 962 P
Multialkali
Quartz
165-850
100 cps
MH 942P
C 942 P
10 cps
MH 943 P
C 943 P
10 cps
MH 944 P
C 944 P
10 cps
MH 952 P
C 952 P
50 cps
MH 962 P
C 962 P
100 cps
Photon Counting Electronics Data
Linear count rate
Output pulse
Over-illumination protection
Output impedance
Supply voltage
Active Quenching Control
5 MHz
TTL, positive
active quenching control
50 ohms
+5 to +5.5 V DC
TTL-Pulse, active high,
RESET: internal via timer, typ. 0,5 s
external via TTL-pulse
adjustable, min. 15 ns, max. 1 µs
< 250 mA
TTL-level: h to l
set time V
ca
to V
ch-ent
+100 V :
≈
150 µs
TTL-level: l to h
set time V
ca
to V
ch-ent
- 100 V :
≈
150 µs
Output pulse width
Input current at max. count rate
GATE voltage V
gate
Maximum Ratings
Input voltage
Operating temperature
Storage temperature
Weight
+5.5 V
5 to 40 °C
-20 to 50 °C
approx. 390 g
MP 900
Typical Spectral Response
100
Quantumefficiency (%)
10
C 943
C 944
1
C 911
0,1
100
200
C 922
C 942
C 962
C 952
300
400
500
600
700
800
900
Wavelength (nm)
Mechanical Specifications
Dimensions in (mm)
50
20
143
44
33
6,5
140
Input/Output Signals: Connections
DB Connector
- 1 (red)
5V
- 3 (black) Gnd
- A1 (coax) External Gate In
- 2 (yellow) Monitor voltage (V
ch-ent
)
- 4 (green) Not connected
BNC Connector
-
TTL Signal Output
-
GND
CAUTION: High Voltage Warning
This product operates at high voltage. Extreme care must be taken to ensure operator safety and to avoid damage to other instruments. Avoid direct contact with the entrance
window of the built in CPM when high voltage is applied. Avoid placing conductive material close to the cathode.
For more information e-mail us at opto@perkinelmer.com or visit our web site at www.perkinelmer.com/opto
All values are nominal; specifications subject to change without notice.
“tensymetry”这个词在《韦伯斯特词典》中没有解释,但在医学界却广为人知。由Tensys Medical Systems公司开发的tensymetry是一种使用生物机械、电气、软件工程的专有组合技术。利用这三种强大的技术,你可在手术室内对病人的心跳血压进行精确、连续、实时和非侵入性测量。 该技术结出的果实就是该公司的T-line Tensymeter产品。该产品线的最新进展是去年...[详细]
Yamaha Motor Group旗下的i-PULSE有限公司日前已与华尔莱科技(Valor)结为合作伙伴关系,基于Valor的vPlan生产规划工具向i-PULSE组装设备的使用者提供完整的从设计到制造的NPI解决方案。在近期日本东京举办的Protec展会(6/11-6/13)上,i-PULSE首度展出了该新产品并将直接向其客户进行销售。 新产品的名称为“iPlan”,它将提供一系...[详细]