Fuses
https://www.schurter.com /PG01_2
D0
Miniature Fuse, 4.7 x 16 mm, 125 VAC
125 VAC · Quick-Acting F
Description
Approvals and Compliances
- Low Breaking Capacity
References
Weblinks
Corresponding Fuseholder
231600P
pdf datasheet, html-datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Detailed request for product
Technical Data
Rated Voltage
Rated current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Tube
Unit Weight
Storage Conditions
Product Marking
125 VAC
0.063 - 10 A
35 A
Quick-Acting F
Fuseholder / Clip
-40 °C to 70 °C
40/070/56 acc. to IEC 60068-1
Glass
1.1 g
0 °C to 60 °C, max. 70% r.h.
, Rated current
Resistance to Vibration
acc. to NF C 20-706 / IEC 60068-2-6,
test Fc
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type:
Approval Logo
Certificates
Certification Body
Description
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Standard
IEC/UL 60950
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Fuses
1
D0
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
https://www.schurter.com /PG01_2
Fuses
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
Dimension [mm]
16 mm
ø 4.7
±0.1
16
±0.5
Pre-Arcing Time
Rated Current In
0.063 A - 10 A
1.1 x In min.
60 min
1.7 x In max.
60 min
3.0 x In max.
200 ms
Time-Current-Curves
100000
10000
1000
100
Time in Seconds
10
1
0.1
0.01
0.001
1
10
Multiple of Rated Current In
2
Fuses
Fuses
https://www.schurter.com /PG01_2
D0
All Variants
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Breaking
Capacity
Voltage Drop
1.0 In typ.
[mV]
1900
1400
1200
960
870
795
825
1950
1500
2200
1700
275
270
175
155
155
210
145
130
100
120
Power Dissi-
pation 1.1 I
n
typ. [mW]
140
150
155
190
240
270
360
955
905
1650
1550
385
560
470
515
610
1160
935
1040
1060
1480
Melting I²t
10.0 Intyp.
[A²s]
0.00044
0.001
0.0015
0.0067
0.012
0.025
0.036
0.03
0.079
0.092
0.13
0.2
0.63
1.2
3.4
4.8
7.8
14
31
68
110
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Order Number
0.063
0.08
0.1
0.15
0.2
0.25
0.31
0.4
0.5
0.63
0.75
1
1.5
2
2.5
3
4
5
6.3
8
10
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
7010.2110
7010.2120
7010.2130
7010.2150
7010.2170
7010.2180
7010.2190
7010.2210
7010.2220
7010.2230
7010.2240
7010.2260
7010.2410
7010.2430
7010.2440
7010.2450
7010.2470
7010.2480
7010.2610
7010.2620
7010.2630
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-
SCHURTER
1) 35 A @ 125 VAC , p.f.
≥
0.9
Packaging Unit
Small Box Pack (10 pcs.)
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Fuses
3
01.12.2017