Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
T9-817
Circuit Breaker for Equipment thermal vertical, THT terminals for PCB mounting, 1 pole
See below:
Approvals and Compliances
Description
-
-
-
-
-
-
-
-
Thermal circuit breaker
1-pole
On request available with elevaled glow-wire ratings
THT connectors
Reset type
Cycling trip-free release
Compact design
Different mounting possibilities
Applications
-
-
-
-
-
-
Unique Selling Proposition
Power supplies
Uninterruptible power supply
Power tools
Industrial appliances
HVAC
Household appliances
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Detailed request for product, Product News, Video
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current
Conditional short circuit ca-
pacity
␣
240 V, 50 / 60 Hz
48 V
4-12 A
IEC: Inc, PC1, AC 240 V: 2 kA
Ambient temperature
␣
Soldering Methods
Solderability
Resistance to Soldering Heat
Weight
5-12 A: -5 °C to 60 °C
4 A: -5°C to 50 °C
Wave
245 °C / 3 sec acc. to IEC 60068-2-
20 / Test Ta, method 1
260 °C / 10 sec acc. to IEC 60068-2-
20 / Test Tb, method 1A
approx. 12.5 g
UL / CSA: SC, AC 240 V DC 48 / 32 V:
2 kA, C1
Degree of protection front side IP 40
Endurance minimum
IEC: 200% Ir, cos
φ
0.6: min. 50 swit-
ching cycles
Endurance typical
4-8 A: 150% Ir, cos
φ
0.9:
2500 switching cycles
␣
10-12 A: 150% Ir, cos
φ
0.9:
6000 switching cycles
Dielectric Strength
1500 VAC
Insulation Resistance
500 VDC > 1000 MΩ
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: T9
Approval Logo
Certificates
VDE Approvals
UL Approvals
CQC Approvals
Certification Body
VDE
UL
CQC
Description
VDE Certificate Number: 40038016
UL File Number: E71572
CCC Certificate Number: 2013010307617688
Circuit Breakers
1
T9-817
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Designed according to
Standard
IEC 60934
UL 1077
CSA C22.2 No. 235
GB 17701
Description
https://www.schurter.com /PG17_18_19
Thermal (T- and TA-Line)
Circuit-breakers for equipment (CBE)
Standard for Supplementary Protectors for Use in Electrical Equipment
Supplementary Protectors
Circuit-breaker for equipment
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Standard
IEC/UL 60950
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
Dimension [mm]
Ø9.5
Ø7.8
0.4
10
4.1
0.8
6.3
7.8 6.8
1.25
10.75 8.25
36.1
12.2
Ø2
.25
3.95 4.3
8
19
8
3.25
R1
5.5
4.3
2.3
6.3
9.2
2
Approval
UL 1077
CSA 22.2 235
IEC 60934
Rated current
4 - 12 A
4 - 12 A
4 - 12 A
Rated voltage AC
240 V
240 V
240 V
Rated voltage DC
48 V
48 V
48 V
GB 17701
4 - 12 A
240 V
48 V
2
Circuit Breakers
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_18_19
T9-817
Typical internal resistance
Rated Current [A]
4
5
6
7
8
10
12
Internal Resistance [mΩ]
26.3
24.1
19.0
18.0
14.8
13.0
12.7
Time-Current-Curves
[min]
[sec]
10'000
T9
60
30
20
10
5
3
1'000
5 A -16 A (TC-1)
4A
(TC-2)
Time in Seconds
100
1
10
1
1.05
Multiple of Rated Current In
Reference Temperature +23°
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated cur-
rent for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
-5
+10
+23
+40
+60
Correction factor
0,85
0,95
1,00
1,08
1,21
Example: Rated current = 10 A; Environmental temperature = 60 °C; --> Correction factor
= 1.21; Resulting current = 12.1 A --> Fount to next higher rated current: 13 A
Variants
connection type
1.35
1.45
0.1
1
2
3
4
5
6
7
8
10
Rated current
Order Number
Solder, THT
Solder, THT
Solder, THT
Solder, THT
4A
5A
6A
7A
3-101-228
3-101-227
3-101-226
3-101-232
Circuit Breakers
3
T9-817
https://www.schurter.com /PG17_18_19
Thermal (T- and TA-Line)
connection type
Rated current
Order Number
Solder, THT
Solder, THT
Solder, THT
8A
10A
12A
3-101-231
3-101-230
3-101-229
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-
Check/Stock-Check-SCHURTER
Packaging Unit
100 Pcs
4
Circuit Breakers
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
12.01.2018