https://www.phoenixcontact.com/us/products/2859466
Type 2 surge arrester - VAL-CP-3C-175 - 2859466
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Plug-in surge arrester for 3-phase power supply networks with N and PE in a common conductor (4-conductor
system: L1, L2, L3, PEN), with remote indication contact.
Product Features
■
■
■
■
■
■
■
■
■
With or without floating remote indication contact
Plugs can be checked with CHECKMASTER
High continuous voltage of 175 V AC for 120/208 V AC networks with high voltage fluctuations
Mechanical coding of all slots
Optical, mechanical status indication for the individual arresters
Type 2 consistent plug-in surge arresters
Disconnect device on each individual plug
Use of varistors that are free of leakage current
Modular arrester blocks with ultra-narrow design
Key Commercial Data
Packing unit
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
1 pc
297.1 g
85369010
Germany
Technical data
Dimensions
Height
Width
Depth
98 mm
37.25 mm
71.5 mm
04/18/2016 Page 1 / 7
https://www.phoenixcontact.com/us/products/2859466
Type 2 surge arrester - VAL-CP-3C-175 - 2859466
Technical data
Dimensions
Horizontal pitch
2 Div.
Ambient conditions
Degree of protection
Ambient temperature (operation)
Ambient temperature (storage/transport)
Altitude
Permissible humidity (operation)
Shock (operation)
Vibration (operation)
IP20
-40 °C ... 80 °C
-40 °C ... 80 °C
≤ 2000 m (amsl (above mean sea level))
5 % ... 95 %
30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
General
Standards/specifications
IEC test classification
EN type
IEC power supply system
Number of ports
SPD design
Mode of protection
Mounting type
Color
Housing material
Degree of pollution
Flammability rating according to UL 94
Type
Number of positions
Surge protection fault message
IEC 61643-11 2011
EN 61643-11 2012
II
T2
T2
TN-C
One
Voltage-limiting type
L-PEN
DIN rail: 35 mm
gray/blue
black
PBT-FR
2
V-0
DIN rail module, two-section, divisible
3
Optical, remote indicator contact
Protective circuit
Nominal voltage U
N
Nominal frequency f
N
Maximum continuous operating voltage U
C
(L-PEN)
Rated load current I
L
Nominal discharge current I
n
(8/20) µs (L-PEN)
Maximum discharge current I
max
(8/20) µs (L-PEN)
120/208 V AC (TN-C)
50 Hz (60 Hz)
175 V AC
40 A (Biconnect M4 fork-type cable lug 6 mm²)
63 A (TWIN ferrule 2 x 10 mm²)
20 kA
40 kA
04/18/2016 Page 2 / 7
https://www.phoenixcontact.com/us/products/2859466
Type 2 surge arrester - VAL-CP-3C-175 - 2859466
Technical data
Protective circuit
Short-circuit current rating I
SCCR
Voltage protection level U
p
(L-PEN)
Residual voltage U
res
(L-PEN)
25 kA
≤ 0.85 kV
≤ 0.85 kV (at I
n
)
≤ 0.75 kV (at 10 kA)
≤ 0.65 kV (at 5 kA)
≤ 0.63 kV (at 4 kA)
≤ 0.57 kV (at 2 kA)
TOV behavior at U
T
(L-PEN)
Response time t
A
(L-PEN)
Max. backup fuse with branch wiring
Max. backup fuse with V-type through wiring
240 V AC (5 s / withstand mode)
240 V AC (120 min / safe failure mode)
≤ 25 ns
315 A (gG)
40 A (gG / Biconnect M4 fork-type cable lug, 6 mm²)
63 A (gG / TWIN ferrule 2x 10mm²)
Indicator/remote signaling
Connection name
Switching function
Operating voltage
Operating current
Connection method
Screw thread
Tightening torque
Stripping length
Conductor cross section flexible
Conductor cross section solid
Conductor cross section AWG
Remote fault indicator contact
PDT contact
5 V AC ... 250 V AC
125 V DC (200 mA DC)
5 mA AC ... 1 A AC
1 A DC (30 V DC)
Pluggable screw connection
M2
0.25 Nm
7 mm
0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm²
28 ... 16
Connection data
Connection method
Conductor cross section flexible
Conductor cross section solid
Conductor cross section AWG
Screw thread
Tightening torque
Stripping length
Screw connection
2.5 mm² ... 16 mm²
2.5 mm² ... 25 mm²
12 ... 4
M5
4.5 Nm
16 mm
UL specifications
04/18/2016 Page 3 / 7
https://www.phoenixcontact.com/us/products/2859466
Type 2 surge arrester - VAL-CP-3C-175 - 2859466
Technical data
UL specifications
SPD Type
Maximum continuous operating voltage MCOV (L-L)
Maximum continuous operating voltage MCOV (L-N)
Nom. voltage
Mode of protection
Power distribution system
Nominal frequency
Measured limiting voltage MLV (L-L)
Measured limiting voltage MLV (L-N)
Nominal discharge current I
n
(L-L)
Nominal discharge current I
n
(L-N)
4CA
350 V AC
175 V AC
120/208 V AC
L-L
L-N
3Y
50/60 Hz
2010 V
1510 V
20 kA
20 kA
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
eCl@ss 8.0
eCl@ss 9.0
27140201
27130801
27130801
27130801
27130805
27130805
27130805
27130805
ETIM
ETIM 2.0
ETIM 3.0
ETIM 4.0
ETIM 5.0
EC000941
EC000941
EC000941
EC000941
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901