Next
Previous
Axial Lead and Cartridge Fuses
Designed to IEC Standard
5 x 20 mm
Time Lag Fuse (Slo-Blo
®
Fuse) 218/213 Series
®
®
D
V
E
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 3 specification for Time Lag Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.032 to 10 amperes.
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
150%
210%
275%
400%
1000%
Ampere
Rating
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
.032 – .100
.125 – 6.3
Opening
Time
60 minutes,
Minimum
60 minutes,
Minimum
2 minutes,
Maximum
2 minutes,
Maximum
0.2 sec.,
Min.;
10 sec.
Max.
0.6 sec.,
Min.;
10 sec.
Max.
.04 sec.,
Min.;
3 sec.
Max.
.15 sec.,
Min.;
3 sec.
Max.
.01 sec.,
Min.;
0.3 sec.
Max.
0.02 sec.,
Min.;
0.3 sec.
Max.
5
(.197")
213
000
218
000
213
223
218
228
000
XE
000
000
XE
000
.635
(.025")
AGENCY APPROVALS:
Sheet III IEC 60127-2:* SEMKO, VDE
approved thru 6.3 amps. BSI approved 0.08-6.3 amps. Recognized under
the Components Program of Underwriters Laboratories and recognized
by CSA. 0213 series METI approved 1-5A.
VOLTAGE RATING:
250 VAC
INTERRUPTING RATINGS:
35 amperes or 10 x rated current;
whichever is greater.
20
(.787")
5.25
(.207")
22.5 MAX
(.886)
40
(1.58")
Average Time Current Curves for 218/228
.032A
.040A
.050A
.063A
.080A
.100A
.125A
.160A
.200A
.250A
.315A
.400A
.500A
.630A
.800A
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
8A
10A
15A
100
10
ORDERING INFORMATION:
For axial leaded change 218 to 228 and 213 to 223.
218/228
Ampere
Rating
Cartridge
Catalog
Number
Nominal
Resistance
Cold Ohmns
Nominal
Melting I
2
t
A
2
Sec.
213/223 Surge Withstand
Cartridge
Catalog
Number
Nominal
Resistance
Cold Ohms
Nominal
Melting
I
2
t A
2
Sec.
.032
.040
.050
.063
.080
.100
.125
.160
.200
.250
.315
.400
.500
.630
.800
1
1.25
1.6
2
2.5
3.15
4
5
6.3
8
10
15
218.032
218.040
218.050
218.063
218.080
218.100
218.125
218.160
218.200
218.250
218.315
218.400
218.500
218.630
218.800
218
001
218
1.25
218
01.6
218
002
218
02.5
218
3.15
218
004
218
005
218
06.3
218
008
218
010
218
015
58.45
35.70
23.30
18.1
12.6
8.95
4.41
2.44
1.60
1.05
0.848
0.535
0.370
0.275
0.073
0.055
0.042
0.032
0.029
0.022
0.017
0.013
0.010
0.0075
0.0059
0.0045
0.0030
0.00305
0.0055
0.0071
0.012
0.0265
0.0495
0.150
0.225
0.350
0.555
1.14
1.35
2.90
4.80
1.99
3.33
5.80
10.61
14.80
23.85
39.20
70.95
114.0
204.0
350.5
583.0
1441.0
–
–
–
–
–
–
–
–
0213.200
0213.250
0213.315
0213.400
0213.500
0213.630
0213.800
0213
001.
0213
1.25
0213
01.6
0213
002.
0213
02.5
0213
3.15
0213
004.
0213
005.
0213
06.3
–
–
–
–
–
–
–
–
–
–
1.60
1.05
0.848
0.535
0.370
0.275
0.165
0.117
0.081
0.055
0.044
0.030
0.022
0.017
0.011
0.008
–
–
–
–
–
–
–
–
–
–
0.350
0.555
1.14
1.35
2.90
4.80
9.42
19.20
27.15
44.2
92.7
138.0
226.5
202
314
600
–
–
8
AXIAL LEAD AND
CARTRIDGE FUSES
1
10
CURRENT IN AMPERES
100
500
295
TIME IN SECONDS
1
1
0.1
0.01
0.001
0.05 0.1
*
IEC Standards for 5 x 20 fuses do not include ratings above 6.3A, but are
under consideration.
Please contact Littelfuse for Average Time Current Curve
for 213/223 surge withstand.
228 and 223 Series are used for North American ordering.
w w w. l i t t e l f u s e . c o m