Surge arrester
2-electrode arrester
Series/Type:
Ordering code:
Date:
Version:
A71-H10X
B88069X3820****
2015-04-20
06
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
Surge arrester
(header 1 + top left bar):
Identification/Classification 2
2-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar)
B88069X3820****
Series/Type: (bottom right header bar)
A71-H10X
Preliminary data (optional):
Department:
PPD AB PD / PPD AB PM
Date:
2015-04-20
Version:
06
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester
2-electrode arrester
B88069X3820****
A71-H10X
Features
Standard size
Fast response time
Stable performance over life
Low capacitance
High insulation resistance
RoHS-compatible
Applications
Power supply
Consumer electronics
Air-con
Electrical specifications
DC spark-over voltage
1) 2)
Tolerance
Min.
Max.
Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs
- for 99% of measured values
- typical values of distribution
Service life
10 operations
1 operations
10 operations
1 operation
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, green positive
1000
YY
O
1000
±15
850
1150
< 1300
< 1200
< 1400
< 1300
10
65
10
15
> 10
<1
~ 20
< 0.5
~ 160
~1
40
... +125
40/ 125/ 21
1000 YY O
- Nominal voltage
- Year of production
- Non radioactive
V
%
V
V
V
V
V
V
A
A
kA
kA
G
pF
V
A
V
g
°C
50 Hz, 1 s
50 Hz, 0.18 s (9 cycles)
8/20 µs
8/20 µs
Insulation resistance at 100 V
DC
Certification
1)
2)
UL 1449 (E319264)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 5
2015-04-20
Surge arrester
2-electrode arrester
Series/Type:
Ordering code:
Date:
Version:
A71-H10X
B88069X3820****
2015-04-20
06
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
Surge arrester
(header 1 + top left bar):
Identification/Classification 2
2-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar)
B88069X3820****
Series/Type: (bottom right header bar)
A71-H10X
Preliminary data (optional):
Department:
PPD AB PD / PPD AB PM
Date:
2015-04-20
Version:
06
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester
2-electrode arrester
B88069X3820****
A71-H10X
Features
Standard size
Fast response time
Stable performance over life
Low capacitance
High insulation resistance
RoHS-compatible
Applications
Power supply
Consumer electronics
Air-con
Electrical specifications
DC spark-over voltage
1) 2)
Tolerance
Min.
Max.
Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs
- for 99% of measured values
- typical values of distribution
Service life
10 operations
1 operations
10 operations
1 operation
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, green positive
1000
YY
O
1000
±15
850
1150
< 1300
< 1200
< 1400
< 1300
10
65
10
15
> 10
<1
~ 20
< 0.5
~ 160
~1
40
... +125
40/ 125/ 21
1000 YY O
- Nominal voltage
- Year of production
- Non radioactive
V
%
V
V
V
V
V
V
A
A
kA
kA
G
pF
V
A
V
g
°C
50 Hz, 1 s
50 Hz, 0.18 s (9 cycles)
8/20 µs
8/20 µs
Insulation resistance at 100 V
DC
Certification
1)
2)
UL 1449 (E319264)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 5
2015-04-20
Surge arrester
2-electrode arrester
B88069X3820****
A71-H10X
Dimensional drawing in mm
Ordering codes and packing advices
B88069X3820S102 = 100 pcs. on 5 taped stripes
B88069X3820T502 = 500 pcs. on tape & reel
PPD AB PD / PPD AB PM
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 5
2015-04-20