Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Electrical Characteristics
(V
CC
= 2.25V to 5.5V, V
BATT
= 3V,
RESET
not asserted, T
A
= -40°C to +85°C, for MAX16039PLA31+T, T
A
= -55°C to +85°C, unless
otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
Operating Voltage Range
Supply Current
SYMBOL
CONDITIONS
V
CC
= 2.8V
I
CC
No load, V
CC
> V
TH
V
CC
= 3.6V
V
CC
= 5.5V
T
A
= +25°C
Supply Current in Battery
Backup Mode
V
BATT
= 2.8V,
V
CC
= 0V,
excluding I
OUT
(V
BATT
+ 0.2V) < V
CC
< 5.5V
T
A
= -40°C to +85°C
T
A
= -55°C
(MAX16039PLA31+T
only)
T
A
= +25°C
T
A
= -40°C to +85°C
-0.1
-0.3
MIN
0
13
16
22
TYP
MAX
5.5
30
35
50
1
2
µA
10
+0.02
+0.02
3.1
3.7
4.6
V
BATT
- 0.2
V
BATT
- 0.15
V
BATT
- 0.15
0
-40
mV
V
Ω
µA
UNITS
V
V
CC
, V
BATT
No load (Note 2)
BATT Standby Current (Note 3)
I
BATT
µA
V
CC
= 4.75V, V
CC
> V
TH
, I
OUT
= 150mA
V
CC
to OUT On-Resistance
R
ON
V
CC
= 3.15V, V
CC
> V
TH
, I
OUT
= 65mA
V
CC
= 2.5V, V
CC
> V
TH
, I
OUT
= 25mA
Output Voltage in Battery
Backup Mode
Battery-Switchover Threshold
V
BATT
= 4.50V, V
CC
= 0V, I
OUT
= 20mA
V
OUT
V
BATT
= 3.15V, V
CC
= 0V, I
OUT
= 10mA
V
BATT
= 2.5V, V
CC
= 0V, I
OUT
= 5mA
V
SW
V
CC
- V
BATT
,
V
CC
< V
TH
V
CC
rising
V
CC
falling
www.maximintegrated.com
Maxim Integrated
│
2
MAX16033–MAX16040
Low-Power Battery-Backup
Circuits in Small μDFN Packages
Electrical Characteristics (continued)
(V
CC
= 2.25V to 5.5V, V
BATT
= 3V,
RESET
not asserted, T
A
= -40°C to +85°C, for MAX16039PLA31+T, T
A
= -55°C to +85°C, unless
otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
RESET OUTPUT
MAX160_ _ _L_46
MAX160_ _ _L_44
Reset Threshold
V
TH
MAX160_ _ _L_31
MAX160_ _ _L_29
MAX160_ _ _L_26
MAX160_ _ _L_23
V
CC
Falling Reset Delay
Reset Active Timeout Period
RESET
Output Low Voltage
RESET
Output High Voltage
RESET
Output Leakage
Current
POWER-FAIL COMPARATOR
PFI Input Threshold
PFI Hysteresis
PFI Input Current
PFO
Output Low Voltage
V
OL
V
OH
V
PFI
= 0V or V
CC
Output asserted
V
CC
>
2.1V, I
SINK
= 1.6mA
V
CC
>
1.2V, I
SINK
= 100µA
0.8 x
V
CC
1
4
0.3 x V
CC
0.7 x V
CC
20
1
V
CC
= 3.3V
100
120
165
-100
V
PFI
V
PFI
falling
1.185
1.235
1
+100
0.3
0.4
1.285
V
%
nA
V
t
RP
V
OL
V
OH
I
LKG
RESET
asserted
I
SINK
= 1.6mA, V
CC
≥
2.1V
I
SINK
= 100µA, V
CC
>
1.2V
0.8 x
V
CC
1
V
CC
falling at 10V/ms
140
4.50
4.25
3.00
2.85
2.55
2.25
4.63
4.38
3.08
2.93
2.63
2.32
25
280
0.3
0.4
4.75
4.50
3.15
3.00
2.70
2.38
µs
ms
V
V
µA
V
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
MAX160_ _L only (push-pull),
RESET
not
asserted, I
SOURCE
= 500µA, V
CC
>
V
TH(MAX)
MAX160_ _P only (open drain), not asserted
PFO
Output High Voltage
PFO
Leakage Current
PFO
Delay Time
MAX160_ _L only (push-pull), V
CC
>
V
TH(MAX),
I
SOURCE
= 500µA, output not
asserted
MAX160_ _P only (open drain), V
PFO
= 5.5V,
not asserted
V
PFI
+ 100mV to V
PFI
- 100mV
V
µA
µs
MANUAL RESET (MAX16033/MAX16037)
MR
Input Voltage
Pullup Resistance to V
CC
Minimum Pulse Width
Glitch Immunity
MR
to Reset Delay
V
IL
V
IH
V
kΩ
µs
ns
ns
www.maximintegrated.com
Maxim Integrated
│
3
MAX16033–MAX16040
Low-Power Battery-Backup
Circuits in Small μDFN Packages
Electrical Characteristics (continued)
(V
CC
= 2.25V to 5.5V, V
BATT
= 3V,
RESET
not asserted, T
A
= -40°C to +85°C, for MAX16039PLA31+T, T
A
= -55°C to +85°C, unless
otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
Watchdog Timeout Period
Minimum WDI Input Pulse Width
WDI Input Voltage
WDI Input Current
BATTON (MAX16035/MAX16039)
Output Voltage
Output Short-Circuit Current
RESETIN (MAX16036/MAX16040)
RESETIN Threshold
RESETIN Input Current
RESETIN to Reset Delay
CEIN
Leakage Current
CEIN
to
CEOUT
Resistance
CEOUT
Short-Circuit Current
CEIN
to
CEOUT
Propagation
Delay (Note 4)
CEOUT
Output-Voltage High
RESET
to
CEOUT
Delay
Note
Note
Note
Note
1:
2:
3:
4:
(V
RTH
+ 100mV) to (V
RTH
- 100mV)
RESET
asserted
RESET
not asserted, V
CC
= V
TH(MAX),
V
CEIN
= V
CC
/2, I
SINK
= 10mA
RESET
asserted, V
CEOUT
= 0V
50Ω source impedance driver, V
CC
= 4.75V
C
LOAD
= 50pF
V
CC
= 3.15V
V
CC
= 5V, V
CC
>
V
BATT
, I
SOURCE
= 100µA
V
CC
= 0V, V
BATT
>
2.2V, I
SOURCE
= 1µA
0.7 x V
CC
V
BATT
- 0.1
1
1
1.5
2
CHIP-ENABLE GATING (MAX16033–MAX16036)
±1
100
2.0
7
9
µA
Ω
mA
ns
V
µs
V
RTH
1.185
1.235
0.01
1.5
1.285
25
V
nA
µs
V
OL
I
SINK
= 3.2mA, V
BATT
= 2.1V
Sink current, V
CC
= 5V
Source current, V
BATT
>
2V
10
60
30
120
0.4
V
mA
µA
SYMBOL
t
WD
t
WDI
V
IL
V
IH
0.7 x V
CC
-1.0
+1.0
(Note 4)
CONDITIONS
MIN
1.00
100
0.3 x V
CC
TYP
1.65
MAX
2.25
UNITS
s
ns
V
µA
WATCHDOG (MAX16034/MAX16038)
All devices are 100% production tested at T
A
= +25°C. All overtemperature limits are guaranteed by design.
EtherCAT(Ethernet for Control Automation Technology)是一种基于以太网的开发构架的实时工业现场总线通讯协议,EtherCAT是最快的工业以太网技术之一,同时它提供纳秒级精确同步。相对于设置了相同循环时间的其他总线系统,EtherCAT系统结构通常能减少25%-30%的CPU负载,EtherCAT的出现为系统的实时性能和拓扑的灵活性树立了新的标准。...[详细]
主题:自备终端(BYOD)发展趋势;用员工自己的移动设备来控制对工作设施及设备的使用,会对信息安全产生怎样的影响;在不使公司有安全风险或不损害员工隐私的前提下,有哪些方式能安全地实现这样的设施及设备使用。 自备终端(Bring Your Own Device,简称BYOD),即企业允许员工离职时保留自己的手机,这种做法正日益流行。如今智能手机功能也越来越多,我们不仅能用自己的手机访问电脑、网...[详细]
As time goes by, people are increasingly concerned about their own and their families' health. However, existing monitoring devices for individual vital signs have struggled to gain market share du...[详细]
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[详细]