voltage and overcurrent-protection devices are ideal to
protect systems against positive and negative input volt-
age faults up to ±40V and feature low 100mΩ(typ) R
ON
FETs.
The overvoltage-protector (OVP) feature protects volt-
ages between 6V and 36V, while the undervoltage-protector
(UVP) feature protects voltages between 4.5V and 24V.
The overvoltage-lockout (OVLO) and undervoltage-lockout
(UVLO) thresholds are set using optional external resistors.
The factory-preset internal OVLO threshold is 33V (typ) and
the preset internal UVLO threshold is 19.2V (typ).
The ICs also feature programmable current-limit protec-
tion up to 4.2A. Once current reaches the threshold,
the MAX14571 turns off after the 20.7ms (typ) blanking
time and stays off during the retry period. The MAX14572
latches off after the blanking time, and the MAX14573 limits
the current continuously. In addition, these devices feature
reverse current and thermal-shutdown protection.
The ICs are available in a small 14-pin TSSOP (5mm
x 6.5mm) package and are specified over the extended
-40°C to +85°C temperature range.
● Integrated Protection Increases System Reliability
● Adjustable OVLO and UVLO Thresholds
(±3% Accurate Preset Thresholds)
● Automatic Internal and External Selection
● Programmable Forward Current Limit (Adjustable Up
to 4.2A) with ±15% Accuracy
● Thermal-Shutdown Protection
● 100mΩ (typ) On-Resistance FET
●
Special Features Facilitate Designs for Industrial
Applications
● Wide 4.5V to 36V Operating Input Range
● Reverse-Current Flow Option for Inductive Loads
● Independent Microprocessor Enable Input (EN) and
High-Voltage-Capable Input (HVEN)
Applications
●
●
●
●
Industrial Equipment
Consumer Electronics
Marine Equipment
Battery-Powered Applications
Typical Operating Circuit
V
POWER
C
IN
IN
IN
IN
Ordering Information
appears at end of data sheet.
OUT
OUT
OUT
COUT
V
PULLUP
SYSTEM
INPUT
R3
R1
MAX14571
MAX14572
MAX14573
UVLO
OVLO
SETI
FLAG
EN
RIEN
HVEN
GND
SYSTEM
R4
R2
NOTE:
R1, R2, R3, AND R4 ARE ONLY REQUIRED FOR ADJUSTABLE
OVLO/UVLO; OTHERWISE, CONNECT UVLO/OVLO TO GND.
19-6470; Rev 4; 7/17
MAX14571/MAX14572/
MAX14573
Absolute Maximum Ratings
(All voltages referenced to GND.)
IN,
HVEN
................................................................-40V to +40V
IN to OUT
...............................................................-40V to +40V
OUT
......................................................................-0.3V to +40V
OVLO, UVLO,
FLAG,
EN, RIEN...........................-0.3V
to +6.0V
Current into IN (DC Operating) (Note 1)
.............. ………….4.2A
SETI..........................………….-0.3V
to Min (V
IN
, 1.22V) + 0.3V
Adjustable Overvoltage and Overcurrent
Protectors with High Accuracy
Continuous Power Dissipation (T
A
= +70NC)
TSSOP (derate 25.6mW/NC
above +70NC) ....... ….2051.3mW
Operating Temperature Range
........................... -40NC to +85NC
Junction Temperature ......................................... ………..+150NC
Storage Temperature Range
............................ -65NC to +150NC
Lead Temperature (soldering, 10s)
...................…………+300NC
Soldering Temperature (reflow)
.........................…………+260NC
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note 1:
DC current is also limited by the thermal design of the system.
Package Information
PACKAGE TYPE: 14 TSSOP
Package Code
Outline Number
Land Pattern Number
THERMAL RESISTANCE, FOUR-LAYER BOARD
Junction to Ambient (θ
JA
)
Junction to Case (θ
JC
)
+39°C/W
+3°C/W
U14E+3
21-0108
90-0119
For the latest package outline information and land patterns (footprints), go to
www.maximintegrated.com/packages.
Note that a “+”, “#”,
or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains
to the package regardless of RoHS status.
Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer board. For
detailed informa¬tion on package thermal considerations, refer to
www.maximintegrated.com/thermal-tutorial.
Electrical Characteristics
(V
IN
= 4.5V to 36V, T
A
= -40NC to +85NC, unless otherwise noted. Typical values are at V
IN
= 24V, R
SETI
= 12kI, T
A
= +25°C.) (Note 2)
PARAMETER
IN Voltage Range
Shutdown Input Current
Shutdown Output Current
Reverse Input Current
Supply Current
Internal Overvoltage Trip Level
Internal Undervoltage Trip Level
Overvoltage-Lockout Hysteresis
SYMBOL
V
IN
I
SHDN
I
OFF
I
IN_RVS
I
IN
V
OVLO
V
UVLO
V
EN
= 0V, V
HVEN
= 5V
V
OUT
= 0V
V
IN
= -40V, V
OUT
= V
GND
= 0V
V
IN
= 15V, R
ISET
= 12kI
V
IN
rising
V
IN
falling
V
IN
falling
V
IN
rising
% of typical OVLO
17.5
18.2
32
-35
490
33
32
18.5
19.2
3
19.5
20.2
700
34
CONDITIONS
MIN
4.5
TYP
MAX
36
15
2
UNITS
V
FA
FA
FA
FA
V
V
%
www.maximintegrated.com
Maxim Integrated │
2
MAX14571/MAX14572/
MAX14573
Electrical Characteristics (continued)
Adjustable Overvoltage and Overcurrent
Protectors with High Accuracy
(V
IN
= 4.5V to 36V, T
A
= -40NC to +85NC, unless otherwise noted. Typical values are at V
IN
= 24V, R
SETI
= 12kI, T
A
= +25°C.) (Note 2)
PARAMETER
External OVLO Adjustment Range
External OVLO Select Voltage
External OVLO Leakage Current
External UVLO Adjustment Range
External UVLO Select Voltage
External UVLO Leakage Current
BG Reference Voltage
INTERNAL FETs
Internal FET On-Resistance
Current-Limit Adjustment Range
Current-Limit Accuracy
FLAG
Assertion Drop Voltage
Threshold
Reverse Current Blocking Threshold
Reverse Blocking Leakage Current
FLAG
OUTPUT
FLAG
Output Logic-Low Voltage
FLAG
Output Leakage Current
LOGIC INPUT
HVEN
Threshold Voltage
HVEN
Threshold Hysteresis
HVEN
Input Leakage Current
HVEN
Input Reverse Leakage
Current
EN, RIEN Input Logic-High
EN, RIEN Input Logic-Low
EN, RIEN Input Leakage Current
THERMAL PROTECTION
Thermal Shutdown
Thermal-Shutdown Hysteresis
TIMING CHARACTERISTICS (Note 6)
Switch Turn-On Time
Switch Turn-Off Time
t
ON
t
OFF
From OFF to IN, see Table 1. R
LOAD
=
240I, C
OUT
= 470FF
R
LOAD
= 47I
25
3
ms
Fs
T
JC_MAX
T
JC_HYST
Low-to-high temperature
High-to-low temperature
150
30
NC
NC
I
HVEN_LEAK
V
HVEN
= 36V
-45
1.4
0.4
V
EN
= V
RIEN
= 5.0V
-1
+1
V
HVEN_TH
1
2
2
26
-27
40
3.5
V
%
FA
FA
V
V
FA
I
SINK
= 1mA
V
IN
= V
FLAG
= 5V,
FLAG
desasserted
0.4
2
V
FA
V
FA
V
RIB
I
RBL
Increase (V
IN
- V
OUT
) drop until
FLAG
asserts, V
IN
= 24V
V
OUT
- V
IN
V
OUT
- V
IN
> 160mV, current into OUT
40
R
ON
I
LIM
I
LOAD
= 100mA, V
IN
R
8V
(Notes 4, 5)
0.7
-15
560
100
400
160
600
100
160
4.2
+15
mI
A
%
mV
mV
FA
V
OVLOSEL
I
UVLO_LEAK
V
BG
(Note 4)
V
OVLOSEL
I
OVLO_LEAK
V
OVLO
< 1.2V (Note 4)
SYMBOL
(Note 3)
CONDITIONS
MIN
6
0.3
-100
4.5
0.3
-100
1.186
1.210
TYP
MAX
36
0.50
+100
24
0.50
+100
1.234
UNITS
V
V
nA
V
V
nA
V
I
HVEN_RLEAK
V
IN
= V
HVEN
= -36V
V
IH
V
IL
I
RIEN_LEAK
I
EN_LEAK,
www.maximintegrated.com
Maxim Integrated │
3
MAX14571/MAX14572/
MAX14573
Electrical Characteristics (continued)
Adjustable Overvoltage and Overcurrent
Protectors with High Accuracy
(V
IN
= 4.5V to 36V, T
A
= -40NC to +85NC, unless otherwise noted. Typical values are at V
IN
= 24V, R
SETI
= 12kI, T
A
= +25°C.) (Note 2)
PARAMETER
Overvoltage Switch Turn-Off Time
Overcurrent Switch Turn-Off Time
IN Debounce Time
Blanking Time
Autoretry Time
ESD PROTECTION
IN
Human Body Model, IN bypassed
to GND with a 1FF low-ESR ceramic
capacitor
Q15
kV
SYMBOL
t
OFF_OVP
t
OFF_OCP
t
DEB
t
BLANK
t
RETRY
After blanking time from I
OUT
> I
LIM
to
FLAG
clear (deassertion) (Note 7)
CONDITIONS
V
IN
> V
OVLO
to V
OUT
= 80% of V
OVLO
,
R
LOAD
= 47I, R
SETI
= 10kI
I
IN
> I
LIM
, after t
BLANK
, I
LIM
= 1A
V
IN
changes from 0V to greater than
V
UVLO
to V
OUT
= 10% of V
IN
15.0
18.6
540
MIN
TYP
3
3
16.7
20.7
600
18.4
22.8
660
MAX
UNITS
Fs
Fs
ms
ms
ms
Note 2:
All units are 100% production tested at T
A
= +25NC.
Limits over the operating temperature range are guaranteed by design
and characterization; not production tested.
Note 3:
Not production tested, user settable. See overvoltage/undervoltage lockout instructions.
Note 4:
Guaranteed by design; not production tested. UVLO and OVLO are internally clamped to BG reference voltage.
Note 5:
The current limit can be set below 700mA with a decreased accuracy.
Note 6:
All timing is measured using 20% and 80% levels.
Note 7:
The ratio between the autoretry time and blanking time is fixed and equal to 30.
便携式数字数据采集系统(PDDAS)使用了LabVIEW实时模块和PXI,以控制风洞测试和采集记录来自128个不同通道的空气压力数据 "通过LabVIEW实时模块,可以在各种操作情况下获得采集空气压力数据及向风洞提供反馈控制信号所需的确定性响应时间。" – Dave Scheibenhoffer, G Systems 挑战: 用一个可采集、分析和存储来自下一代喷气式战斗机引擎设计的动...[详细]