www.murata-ps.com
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
Typical unit
FEATURES
Five-sided shielded metal package reduces
radiated emissions
Industry standard 1" x 1" x 0.40"
encapsulated package and pinout
range input voltages 9-36 and
Wide
18-75 Vdc
Bipolar ±5V, ±12V and ±15V outputs
to 15 Watts or greater total output
Up
power with overtemperature shutdown
Isolation up to 1600 VDC (basic)
efficiency flyback topology
High
Usable -40 to 85°C temperature range
(with derating)
Assembly and attachment for RoHS standards
Extensive self-protection shut down
features
Meets UL 60950-1, CAN/CSA-C22.2 No.
60950-1, IEC60950-1, EN60950-1 safety
approvals (2nd Edition)
PRODUCT OVERVIEW
Featuring a full 15 Watt output in one square
inch of board area, the BPM15 series isolated
DC-DC converter family offers efficient regulated
DC power for printed circuit board mounting. The
wide range 4:1 inputs on the 1" x 1" x 0.40" (25.4
x 25.4 x 10.16mm) converter are either 9 to 36
Volts DC (Q12 models) or 18 to 75 Volts DC (Q48
models), ideal for battery-powered and telecom
equipment. The industry-standard pinout fits larger
1" x 2" converters. Fixed output voltages of ±5,
±12 or ±15 VDC are regulated to within ±0.25%.
Applications include small instruments, area-
limited microcontrollers, data communications
equipment, remote sensor systems, vehicle and
portable electronics.
The rugged mechanical, thermal, and electrical
design of this product is intended for high reliability
and harsh environments.
The BPM15 series includes full magnetic and
optical isolation with Basic protection up to 1600
Volts DC. For powering digital systems, the outputs
offer fast settling to step transients and will accept
higher capacitive loads. Excellent ripple and noise
specifications assure compatibility to noise-sus-
ceptible circuits. For systems requiring controlled
startup/shutdown, an external remote On/Off
control may use a switch, transistor or digital logic.
A wealth of self-protection features avoid both
converter and external circuit faults. These include
input undervoltage lockout and overtemperature
shutdown. The outputs current limit using the
“hiccup” autorestart technique and the outputs
are short-circuit protected. Additional features
include output overvoltage and reverse conduction
elimination. The high efficiency offers minimal heat
buildup and “no fan” operation.
CONNECTION DIAGRAM
F1
+Vin (1)
Barrier
External
DC
Power
Source
+Vout (6)
On/Off
Control
(3)
Controller
and
Power
Common (5)
-Vout (4)
Open = On
Reference and
Error Amplifier
-Vin (2)
Typical topology is shown.
For full details go to
www.murata-ps.com/rohs
Murata Power Solutions recommends a fuse at F1.
www.murata-ps.com/support
MDC_BPM15.A02
Page 1 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
➀
Output
R/N (mVp-p) Regulation (Max.)
I
OUT
Total
V
OUT
(mA,
Power
Typ. Max.
Line
Load
➄
Root Models
➀
(V) max.)
➁
(W)
BPM15-050-Q12
BPM15-050-Q48
BPM15-120-Q12
BPM15-120-Q48
BPM15-150-Q12
BPM15-150-Q48
±5
±5
±12
±12
±15
±15
±1500
±1500
±625
±625
±500
±500
15
15
15
15
15
15
60
60
80
80
60
80
100
100
120
120
100
120
±0.25%
±0.25%
±0.25%
±0.25%
±0.25%
±0.25%
±0.25%
±0.25%
±0.25%
±0.25%
Input
I
IN
=
V
IN
minimum
Nom. Range
load
(mA)
(V)
(V)
24
48
24
48
24
48
9-36
18-75
9-36
18-75
9-36
18-75
90
50
95
50
100
50
I
IN
=
full
load
(mA)
740
384
740
368
740
360
Efficiency
Encapsulated
Package
Min.
82.5%
80%
82%
83%
82.5%
83%
Typ.
84%
81.4%
84%
85%
84.5%
86%
(inches)
(mm)
1 x 1 x 0.40
25.4 x 25.4 x 10.16
±0.25% ±0.275%
➀
Please refer to the part number structure for additional options and complete
ordering part numbers.
➁
The minimum output load for the BPM15 series is 10% of maximum current to
meet published specifications. The converter will not be damaged by less than
10% load but some specs may degrade slightly.
➂
All specifications are at nominal line voltage and full load, +25 °C. unless other-
wise noted. See detailed specifications and notes for full conditions.
Output capacitors are 1 μF ceramic in parallel with 10 μF. The input cap is 100 μF,
low ESR electrolytic.
I/O caps are necessary for our test equipment and may not be needed for your
application.
➃
RoHS-6 compliance does not claim EU RoHS exemption 7b (lead in solder).
➄
Balanced loads, 10% to 100% loads.
PART NUMBER STRUCTURE
BPM15
-
050
-
Q48 P Lx
-
C
Bipolar Wide Input
15-Watt Series
Nominal Output Voltage
in Tenths of a Volt
Input Voltage Range
Q12
= 9-36V
Q48
= 18-75V
RoHS-6 Hazardous
Substance Compliance (note 4)
Pin Length Option
Blank
= Std. pin length 0.25˝ (6.3mm)
L1
= 0.110˝ (2.79mm)
L2
= 0.145˝ (3.68mm)
*
*
On/Off Control Logic
P
= Positive
N
= Negative
Blank
= Control pin omitted
‡
*Minimum
order quantity is required.
Samples available with standard pin
length only.
‡
Some model number combinations may not
be available. See website or contact your local
Murata sales representative.
www.murata-ps.com/support
MDC_BPM15.A02
Page 2 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-050-Q12
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Output Current
Conditions
➀
100 mS max. duration
Input to output
Power on, referred to -Vin
Minimum
0
Typical/Nominal
Maximum
36
50
1600
15
15.15
Units
Vdc
Vdc
Vdc
Vdc
W
0
1.48
Current-limited, no damage, short-circuit
0.15
1.5
A
protected
Storage Temperature Range
Vin = Zero (no power)
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
9
24
36
Vdc
Recommended External Fuse
Fast blow
4
A
Start-up Threshold
Rising input voltage
8
8.5
9
Vdc
Undervoltage Shutdown (50% load)
Falling input voltage
7.7
8.2
8.7
Vdc
Internal Filter Type
C
Input Current
Full Load Input Current
Vin = nominal
0.74
0.77
A
Low Line Input Current
Vin = minimum
2.03
2.09
A
Inrush Transient
0.05
A2-Sec.
Short Circuit Input Current
0.05
0.1
A
Minimum Load Input Current
Iout = minimum, unit = ON
90
150
mA
Shut-Down Input Current (Off, UV, OT)
1
2
mA
Measured at input with specified filter
25
mA, p-p
Reflected (Back) Ripple Current
➁
GENERAL and SAFETY
Vin = 24V, full load
82.5
84
%
Efficiency
Vin = min., full load
80.5
82
%
Isolation
Isolation Voltage
Input to output
1600
Vdc
Isolation Resistance
10
MΩ
Isolation Capacitance
1000
pF
Certified to UL-60950-1, CSA-C22.2 No.
Safety
Approved
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
Calculated MTBF
5.8
Hours x 10
6
fixed, Tambient = +25°C
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
330
360
390
KHz
Startup Time
Power on to Vout regulated
50
mS
Startup Time
Remote ON to Vout regulated
50
mS
50-75-50% load step, settling time to within
Dynamic Load Response
250
300
μSec
1% of Vout
Dynamic Load Peak Deviation
same as above
±100
±150
mV
FEATURES and OPTIONS
Remote On/Off Control
➂
“N” suffix
Negative Logic, ON state
ON = Ground pin
-0.7
0.8
V
Negative Logic, OFF state
OFF = Pin open
10
15
V
Control Current
Open collector/drain
1
mA
“P” suffix
Positive Logic, ON state
ON = Pin open
10
15
V
Positive Logic, OFF state
OFF = Ground pin
-0.7
0.8
V
Control Current
Open collector/drain
1
mA
www.murata-ps.com/support
MDC_BPM15.A02
Page 3 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-050-Q12 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Conditions
➀ ➂
Minimum
1.48
±4.95
5.6
±0.15
±1.65
Typical/Nominal
15
±5
±1
6.5
±1.5
±2.8
Maximum
15.15
±5.05
7
±1.5
±3.3
0.3
Continuous
Units
W
Vdc
% of Vnom
Vdc
A
A
A
No trim
At 50% load, no trim
Via magnetic feedback
98% of Vnom., after warmup
Hiccup technique, autorecovery within
±1.25% of Vout
Output shorted to ground, no damage
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 24V
5 Hz - 20 MHz BW, Vin = 24V
Low ESR, 0.02 Ω max
60
±0.25
±0.25
100
520
% of Vout
% of Vout
mV pk-pk
μF
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
WxLxH
Nickel subplate
Gold overplate
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
-40
-40
-55
120
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
85
93
125
140
°C
°C
°C
°C
Class
130
B
RoHS-6
Notes
➀
Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF, electrolytic.
➁
Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂
The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02
Page 4 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-050-Q12
Efficiency vs. Line Voltage and Load Current @ +25°C
85
83
81
Power Dissipation (Watts)
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0.16
Vin=9V
Vin=12V
Vin=24V
Vin=36V
Power Dissipation vs. Line Voltage and Load Current @ +25°C
79
Efficiency (%)
77
Vin=9V
75
73
71
69
67
65
0.16
Vin=12V
Vin=24V
Vin=36V
0.31
0.46
0.31
0.46
0.61
0.76
0.91
1.06
1.21
1.36
1.51
0.61
0.76
0.91
1.06
Output Load Curre nt (Amps)
1.21
1.36
1.51
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(V
IN
= 9V, airflow is from pin 1 to pin 4)
1.5
1.4
1.3
1.2
Output Current (A)
Output Current (A)
1.5
1.4
1.3
1.2
Maximum Current Temperature Derating at Sea Level
(V
IN
= 12V, airflow is from pin 1 to pin 4)
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
1.1
1
0.9
0.8
0.7
0.6
0.5
30
35
40
45
50
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
1.1
1
0.9
0.8
0.7
0.6
0.5
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
www.murata-ps.com/support
MDC_BPM15.A02
Page 5 of 29