EMC filters
2-line filters
SIFI-D for high insertion loss
Series/Type:
Date:
B84114D
May 2014
© EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
2-line filters
SIFI-D for high insertion loss
B84114D
Power line filters for 1-phase systems
Rated voltage V
R
: 250 V AC/DC
Rated current I
R
: 1 A to 10 A
Construction
2-line filters
Metal case
Polyurethane potting (UL 94 V-0)
Features
Easy to install
Compact design
Optimized leakage current
ENEC, UL and cUL approval
Typical applications
Switch-mode power supplies
Industrial electronics
Telecommunications
Data systems
DC applications
Terminals
Tab connectors
Marking
Marking on component:
Manufacturer's logo, ordering code, rated voltage, rated
current, rated temperature, climatic category, date code,
approvals
Minimum data on packaging:
Manufacturer's logo, ordering code, quantity, date code
Circuit diagram
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 2 of 10
2-line filters
SIFI-D for high insertion loss
B84114D
Technical data and measuring conditions
Rated voltage V
R
Rated current I
R
Test voltage V
test
Climatic category (IEC 60068-1)
Approvals
Characteristics and ordering codes
I
R
A
C
R
X2
µF
C
R
Y2
pF
2
×
4700
2
×
4700
2
×
4700
2
×
4700
2
×
4700
2
×
4700
2
×
4700
2
×
4700
2
×
4700
2
×
4700
L
R
mH
2
×
5.6
2
×
5.6
2
×
5.6
2
×
5.6
2
×
5.6
2
×
5.6
2
×
4.7
2
×
4.7
2
×
4.7
2
×
4.7
I
LK
mA
0.369
0.369
0.369
0.369
0.369
0.369
0.369
0.369
0.369
0.369
Approx.
weight
g
150
150
150
150
150
150
230
230
420
420
Ordering code
Approvals
250 V AC (50/60 Hz) / 250 V DC
Referred to 40
°C
rated temperature
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
25/085/21 ( 25
°C/+85 °C/21
days damp heat test)
IEC 60939, UL 1283, CSA C22.2 No.8
V
R
= 250 V AC/DC
1
2
×
0.47
1
2
×
0.47
2
2
×
0.47
2
2
×
0.47
3
2
×
0.47
3
2
×
0.47
6
2
×
0.47
6
2
×
0.47
10
2
×
0.68
10
2
×
0.68
B84114D0000A010
B84114D0000B010
B84114D0000A020
B84114D0000B020
B84114D0000A030
B84114D0000B030
B84114D0000A060
B84114D0000B060
B84114D0000A110
B84114D0000B110
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
= Approval granted
Cases and dimensions
I
R
A
1
1
2
2
3
3
6
6
10
10
Dimensions (mm)
b
1
b
2
b
3
50.8
31.5
60.4
50.8
31.5
50.8
31.5
60.4
50.8
31.5
50.8
31.5
60.4
50.8
31.5
50.8
31.5
60.4
50.8
31.5
b
4
70
70
70
70
l
1
63.5
63.5
63.5
63.5
63.5
63.5
75.5
75.5
l
2
74.7
74.7
74.7
87.1
l
3
84.5
84.5
84.5
97
l
4
89.5
89.5
89.5
89.5
89.5
89.5
101.5
101.5
h
1
28.6
28.6
28.6
28.6
28.6
28.6
31.8
31.8
h
2
20
20
20
20
20
20
20
20
See dimensional drawing
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 3 of 10
2-line filters
SIFI-D for high insertion loss
B84114D
B84114D0000A010 ... A60 (1 A ... 6 A)
B84114D0000A110 (10 A)
General tolerances according to ISO 2768 cL
Dimensions in mm
B84114D0000B010 ... B60 (1 A ... 6 A)
General tolerances according to ISO 2768 cL
Dimensions in mm
B84114D0000B110 (10 A)
General tolerances according to ISO 2768 cL
Dimensions in mm
General tolerances according to ISO 2768 cL
Dimensions in mm
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 4 of 10
2-line filters
SIFI-D for high insertion loss
Insertion loss
(typical values at Z = 50
Ω)
B84114D
Filters for 1 A, 2 A and 3 A
Filters for 6 A
Filters for 10 A
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Page 5 of 10