Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
49
X
17
X
94mm (W
X
H
X
D) / 65g max
Convection
15
0.7
60max
120max
120max
160max
150max
180max
150max
60max
24
0.5
96max
150max
120max
160max
150max
180max
240max
96max
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
50
X
17
X
115mm (W
X
H
X
D) / 80g max
Convection
INPUT
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24, 36, 48V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
34.5 - 37.5
46.0 - 50.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
50
X
25
X
132.5mm (W
X
H
X
D) / 150g max
Convection
INPUT
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
中国 北京—— Analog Devices, Inc. (纽约证券交易所代码 : ADI ),全球领先的高性能信号处理解决方案供应商,最新推出两款模拟输出驱动器—— AD5750 和 AD5751 ,能显著提高过程控制应用的效率和可靠性,包括那些在高恒流电压和高温条件下工作的过程控制应用。这两款器件基于 ADI 公司的 iCMOS ™工业工艺技术,输出驱动器的精度...[详细]
“tensymetry”这个词在《韦伯斯特词典》中没有解释,但在医学界却广为人知。由Tensys Medical Systems公司开发的tensymetry是一种使用生物机械、电气、软件工程的专有组合技术。利用这三种强大的技术,你可在手术室内对病人的心跳血压进行精确、连续、实时和非侵入性测量。 该技术结出的果实就是该公司的T-line Tensymeter产品。该产品线的最新进展是去年...[详细]