https://www.phoenixcontact.com/hq/products/2867429
Wireless module - RAD-ISM-900-SET-AC-UD-AU - 2867429
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Unidirectional, wireless, 900 MHz transmission system (Australia), consists of an outdoor transmitter
(transmitter, Tx) with 100...240 V AC supply, a DIN-mountable receiver (receiver, Rx) with 12...30 V DC
supply, and antennas
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356046824
85176990
Made to Order (non-returnable)
1 STK
Technical data
Note
Trade restriction
The products are offered exclusively for export outside the EU and the
European Economic Area.
Dimensions
Width
Height
Depth
Width
Height
Depth
17.5 mm
99 mm
114.5 mm
57 mm
57 mm
280 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection
-40 °C ... 70 °C
-40 °C ... 85 °C
IP20
Wireless set
11/15/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/2867429
Wireless module - RAD-ISM-900-SET-AC-UD-AU - 2867429
Technical data
Wireless set
Set contents
Transmitter, receiver
Wireless path
Direction
Frequency range
Number of channel groups
Number of channels per group
Transmission power
Uni-directional
915.1 MHz ... 927.8 MHz
2
63
1W
Analog input (sender)
Description of the input
Current input signal
Input resistance current input
Current input (analog input)
4 mA ... 20 mA
< 170 Ω
Digital input (sender)
Input voltage range
85 V AC ... 240 V AC
Analog output (receiver)
Output name
Current output signal
Load/output load current output
Current output
4 mA ... 20 mA
700 Ω (at U
B
= 24 V, R
B
= [U
B
-10 V] / 20 mA)
Digital output (receiver)
Output name
Contact type
Contact material
Maximum switching voltage
Limiting continuous current
Mechanical service life
Service life, electrical
2 x relay output + 1 x RF link
3 floating PDT contacts
Ag, gold-plated
30 V DC
120 V AC
0.5 A
1x 10
7
5
8 x 10 cycles at a switching current of 0.5 A
Supply (receiver)
Supply voltage
Supply voltage range
Typical current consumption
Max. current consumption
24 V DC (at U
B
)
12 V DC ... 30 V DC
85 mA
125 mA
Supply (sender)
Supply voltage
Supply voltage range
Typical current consumption
Max. current consumption
230 V AC
100 V AC ... 240 V AC
57 mA
109 mA
Connection data
11/15/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/2867429
Wireless module - RAD-ISM-900-SET-AC-UD-AU - 2867429
Technical data
Connection data
Screw thread
M3
Standards and Regulations
Electromagnetic compatibility
FCC Part 15.247
Drawings
Block diagram
Loop Power Out
7
+24 V
8
R
B
9
GND
12 / NC
3
9
NO / 14
4...20 mA IN
14 / NO
1
11 / COM
2
Block diagram
OUT 1
RF Link
7
NC / 12
8
COM / 11
µC
RF
RF OUT
10
IN 1
µC
RF IN
4...20 mA OUT
4
RF
10
NC / 12
11
COM / 11
Power
+24 V
4
Power
11
COM
12
IN 2
GND
5
6
GND
5
+24 V
6
12
NO / 14
OUT 2
Transmitter module
Receiver module
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/15/2016 Page 3 / 3