FR601 - FR607
6.0A FAST RECOVERY RECTIFIER
Features
·
·
·
·
·
Low Reverse Recovery Time
Low Reverse Current
Low Forward Voltage Drop
High Current Capability
Plastic Material: UL Flammability
Classification Rating 94V-0
A
B
A
C
Mechanical Data
·
·
·
·
·
Case: R-6, Molded Plastic
Terminals: Axial Leads, Solderable per
MIL-STD-202 Method 208
Polarity: Color Band Denotes Cathode
Weight: 1.7 grams (approx.)
Mounting Position: Any
R-6
Dim
A
B
C
D
Min
25.4
8.6
1.2
8.6
D
Max
¾
9.1
1.3
9.1
All Dimensions in mm
Maximum Ratings and Electrical Characteristics
Characteristic
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking voltage
Maximum Average Forward Rectified Current
9.5mm Lead Length
@ T
A
=75°C
Peak Forward Surge Current
8.3ms single half sine-wave superimposed on rated load
(JEDEC method)
Maximum Instantaneous Forward Voltage
@ 6.0A DC
Maximum DC Reverse Current at Rated Blocking Voltage
@ T
A
= 25°C
Maximum Full Load Reverse Current
Full Cycle Average 9.5mm lead length
@ T
L
= 55°C
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
Symbol
V
RRM
V
RMS
V
DC
I
(AV)
I
FSM
V
F
I
R
I
R
T
rr
C
J
T
J
, T
STG
FR
601
50
35
50
@ T
A
= 25°C unless otherwise specified.
FR
602
100
70
100
FR
603
200
140
200
FR
604
400
280
400
6.0
300
1.3
10
150
150
200
-65 to +175
250
500
FR
605
600
420
600
FR
606
800
560
800
FR
607
1000
700
1000
Unit
V
V
V
A
A
V
mA
mA
ns
pF
°C
Notes:
1. Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
RR
=0.25A
2. Measured at 1.0MHz and applied reverse voltage of 4.0V.
DS26004 Rev. C1-3
1 of 2
FR601-FR607
I
Fsm
, PEAK FORWARD SURGE CURRENT (AMPERES)
8
I
(AV)
, AVERAGE FORWARD CURRENT
600
8.3ms Single Half Sine-Wave
JEDEC Method
6
500
400
300
200
100
0
1
10
100
NUMBER OF CYCLES AT 60 Hz
Fig. 2, Max Non-Repetitive Peak Surge Current
4
2
0
0
25
50
75
100
125
150
175
T
A
, AMBIENT TEMPERATURE (°C)
Fig. 1, Typical Forward Current Derating Curve
I
F
, INSTANTANEOUS FORWARD CURRENT (AMPERES)
1000
I
FSM
, PEAK FORWARD SURGE CURRENT (AMPERES)
200
100
100
10
1
T
J
= 25°C
Pulse Width
= 300µs
1% Duty Cycle
0.1
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
V
F
, INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
Fig. 3, Typical Instantaneous Forward Characteristics
10
1
10
100
NUMBER OF CYCLES AT 60Hz
Fig. 4, Maximum Non-Repetitive Surge Current
DS26004 Rev. C1-3
2 of 2