1F10 thru 1F18
High Voltage Fast Recovery Rectifiers
Reverse Voltage 1000 to 1800 Volts Forward Current 1.0 Ampere
Features
Fast switching
Low leakage
Low forward voltage drop
High current capability
High currenf surge
High reliability
Mechanical Data
Case: Molded plastic R-1
Epoxy: UL 94V-O rate flame retardant
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.007 ounce, 0.20 gram
Maximum Ratings and Electrical Characteristics
Ratings at 25
o
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Parameter
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward rectified current at T
A
=50
o
C
Peak forward surge current, 8.3 ms single half sine-
wave superimposed on rated load (JEDEC Method)
Maximum instantaneous forward voltage at 0.5A DC
Maximum DC reverse current
at rated DC blocking voltage at T
A
=25
o
C
Maximum full load reverse current average, full cycle
average, .375" (9.5mm) lead length at T
L
=55
o
C
Maximum reverse recovery time (Note 1)
Typical junction capacitance (Note 2)
Operating junction and storage temperature range
Notes:
Symbols
V
RRM
V
RMS
V
DC
I
F(AV)
I
FSM
V
F
I
R
I
R(AV)
t
rr
C
J
T
J
, T
STG
1F 10
1000
700
1000
1F 12
1200
840
1200
1F 14
1400
980
1400
0.5
25.0
1.8
5.0
100
300
15
1F 15
1500
1050
1500
1F 16
1600
1120
1600
1F 18
1800
1260
1800
Units
Volts
Volts
Volts
Amp
Amps
Volts
uA
uA
ns
pF
o
-55 to +150
C
1. Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
RR
=0.25A
2. Measured at 1 MHZ and applied reverse voltage of 4.0 volts