Grenzkurve für maximale Pulsenergie bzw. Pulsleistung für Dauerbetrieb
Maximum puls energy resp. pulse power for continuous operation
10000
1000
Die dargestellte Kurve gilt für den Widerstandswert R010. für andere Werte kann die Kurve im unteren Bereich ggf. anders verlaufen, so dass in Grenzbereichen eine separate
Qualifikation erfolgen sollte.
This curve is only valid for the resistance value R010. The shape of the curve in the range below 0.1 sec will be different for other resistance values. Therefore a separate qualification
should be made for pulse power close to the above curve.
Spezifikationen/Specifications
Parameters
Maximum Temperature for full power operation
Working Temperature
Thermal Shock
Overload
Solderability
Resistance to Solvents
Low Temperature Storage and Operation
Resistance to Soldering Heat
Moisture Resistance
Shock
Vibration, High frequency
Life
Storage Life at elevated Temperature
High Temperature exposure
Current Noise
Voltage Coefficient (%/V)
Resistance Temperature Characteristic
Thermal eMf
frequency Characteristic
test conditions
80 °C
-55 to 140 °C
MIL-STD-202 method 107-B1
MIL-R-26e (5 times rated power, 5 sec)
MIL-STD-202 method 208
MIL-STD-202 method 215A, 2.1a, 2.1d
MIL-STD-26e
MIL-STD-202 method 210
MIL-STD-202 method 106
MIL-STD-202 method 213-A
MIL-STD-202 method 204-B
MIL-STD-26e
MIL-STD-202 method 108-f
140 °C, 2000 h
MIL-STD-202 method 308
MIL-STD-202 method 309
MIL-STD-202 method 304 (20-60°C)
0 - 100 °C
inductivity
Specification
80 °C
-55 to 140 °C
0.1 %
0.2 %
> 95 % coverage
no damage
0.1 %
0.1 %
0.1 %
0.2 %
0.2 %
0.2 %
0.3 %
0.2%
0.01 %
linearity error less than 120dB
<30 ppm/K
3 µV/K max.
< 10 nH
typical data
80 °C
-55 to 140 °C
0.05 %
0.1 %
0.05 %
0.05 %
0.1 %
0.2 %
0.2 %
0.2 %
0.3 %
0.2 %
0.01 %
<30 ppm/K
2 µV/K
< 7 nH
Den aktuellen Stand des Datenblattes finden Sie auf unserer Internetseite-You can always find the current valid issue of data sheet on our homepage
FLASH锁死了这是为什么,有没有办法解锁。为什么会有类似下面这几种报错:
Read status value 0x0001 from symbol PRG_status(24x系列)
ADC Calibration not complete, check if device is un ......