PBAS40TW-AU~BAS40SDW-AU
SURFACE MOUNT SCHOTTKY DIODES
Voltage
Features
40 V
Current
0.2 A
SOT-363
Reverse voltage rating of 40V
Lead free in compliance with EU RoHS 2.0
Green molding compound as per IEC 61249 standard
AEC-Q101 qualified
BAS40TW-AU
BAS40ADW-AU
Mechanical Data
Case: SOT-363 Package
Terminals: Solderable per MIL-STD-750, Method 2026
Approx. Weight: 0.0002 ounces, 0.006 grams
BAS40CDW-AU
BAS40SDW-AU
Maximum Ratings and Thermal Characteristics
(T
A
= 25 C unless otherwise noted)
PARAMETER
Maximum Repetitive Peak Reverse Voltage
Maximum Rms Voltage
Maximum Dc Blocking Voltage
Maximum Average Forward Current
Peak Forward Surge Current: 1 s Single Half Sine-
Wave Superimposed On Rated Load
Maximum Junction Capacitance
Measured at 1 MHZ And Applied V
R
= 0 V
Typical Thermal Resistance
Operating Junction Temperature Range
Storage Temperature Range
SYMBOL
V
RRM
V
RMS
V
DC
I
F(AV)
I
FSM
C
J
R
θJA
T
J
T
STG
(1)
o
LIMIT
UNITS
V
V
V
A
A
pF
o
40
28
40
0.2
0.6
5
540
-55~150
-55~150
C/W
o
o
C
C
January 18,2019-REV.00
Page 1
PBAS40TW-AU~BAS40SDW-AU
Electrical Characteristics
(T
A
= 25 C unless otherwise noted)
PARAMETER
SYMBOL
TEST CONDITION
I
F
= 1 mA, T
J
= 25 C
I
F
= 10 mA, T
J
= 25 C
Forward Voltage
V
F
I
F
= 40 mA, T
J
= 25 C
I
F
= 1 mA, T
J
= 125 C
I
F
= 10 mA, T
J
= 125 C
I
F
= 40 mA, T
J
= 125 C
V
R
= 30 V, T
J
= 25 C
Reverse Current
I
R
(2)
o
o
o
o
o
o
o
o
o
MIN.
-
-
-
-
-
-
-
-
-
TYP.
-
-
-
0.21
0.35
0.55
-
-
22
MAX.
0.38
0.5
1
UNITS
V
-
-
-
0.5
1
-
uA
V
R
= 40 V, T
J
= 25 C
V
R
= 40 V, T
J
= 125 C
o
NOTES:
1. Mounted on a FR4 PCB, single-sided copper, mini pad.
2. Short duration pulse test used to minimize self-heating effect.
January 18,2019-REV.00
Page 2
PBAS40TW-AU~BAS40SDW-AU
TYPICAL CHARACTERISTIC CURVES
C
J
, Junction Capacitance (pF)
240
10
I
F
, Forward Current (mA)
200
160
120
80
40
0
0
25
50
75
100
125
150
1
0
0
10
20
30
40
T
A
, Ambient Temperature (°C)
Fig.1 Forward Current Derating Curve
V
R
, Reverse Bias Voltage (V)
Fig.2 Typical Junction Capacitance
100
1000
T
J
= 150°C
10
1
0.1
0.01
T
J
= 25°C
20
40
60
80
100
T
J
= 125°C
I
F
, Forward Current (mA)
I
R
, Reverse Current (uA)
100
T
J
= 150°C
T
J
= 125°C
T
J
= 75°C
10
T
J
= 75°C
T
J
= 25°C
1
0
0.2
0.4
0.6
0.8
1
1.2
0.001
Percent of Rated Reverse Voltage (%)
Fig.3 Typical Reverse Characteristics
V
F
, Forward Voltage (V)
Fig.4 Typical Forward Characteristics
Percent of Reverse Voltage (%)
120
100
80
60
40
20
0
0
25
50
75
100
125
150
T
J
, Junction Temperature (°C)
Fig.5 Operating Temperature Derating Curve
January 18,2019-REV.00
Page 3
PBAS40TW-AU~BAS40SDW-AU
Part No Packing Code Version
Part No Packing Code
BAS40TW-AU_R1_000A1
BAS40ADW-AU_R1_000A1
BAS40CDW-AU_R1_000A1
BAS40SDW-AU_R1_000A1
Package Type
SOT-363
SOT-363
SOT-363
SOT-363
Packing Type
3K / 7" Reel
3K / 7" Reel
3K / 7" Reel
3K / 7" Reel
Marking
S40
S42
S43
S44
Version
Halogen free
Halogen free
Halogen free
Halogen free
Packaging Information & Mounting Pad Layout
SOT-363 Dimension
Unit: inch(mm)
SOT-363 Pad Layout
Unit: inch(mm)
January 18,2019-REV.00
Page 4
PBAS40TW-AU~BAS40SDW-AU
Disclaimer
● Reproducing and modifying information of the document is prohibited without permission from Panjit
International Inc..
● Panjit International Inc. reserves the rights to make changes of the content herein the document anytime
without notification. Please refer to our website for the latest document.
● Panjit International Inc. disclaims any and all liability arising out of the application or use of any product
including damages incidentally and consequentially occurred.
● Panjit International Inc. does not assume any and all implied warranties, including warranties of fitness for
particular purpose, non-infringement and merchantability.
● Applications shown on the herein document are examples of standard use and operation. Customers are
responsible in comprehending the suitable use in particular applications. Panjit International Inc. makes no
representation or warranty that such applications will be suitable for the specified use without further testing or
modification.
● The products shown herein are not designed and authorized for equipments relating to human life and for any
applications concerning life-saving or life-sustaining, such as medical instruments, aerospace machinery et
cetera. Customers using or selling these products for use in such applications do so at their own risk and
agree to fully indemnify Panjit International Inc. for any damages resulting from such improper use or sale.
● Since Panjit uses lot number as the tracking base, please provide the lot number for tracking when
complaining.
January 18,2019-REV.00
Page 5