Semiconductor (AC) fuses
Other Protistor
®
Fuses
Ferrule Fuses
10x38 gRB - 690VAC
Semiconductor fuses
Dimensions / Reference / Ref. No.
Rating (A)
Designation
Ref. Number
Catalog Number
1
1,25
1,5
2
2,5
3
4
5
6
8
10
12,5
16
20
25
30
32*
6,9 gRC 10-01 - A070 gRC 01 T13
6,9 gRB 10-1,25 - A070 gRB 1.25 T13
6,9 gRB 10-1,5 - A070 gRB 1.5 T13
6,9 gRB 10-02 - A070 gRB 02 T13
6,9 gRB 10-2,5 - A070 gRB 2.5 T13
6,9 gRB 10-03 - A070 gRB 03 T13
6,9 gRB 10-04 - A070 gRB 04 T13
6,9 gRB 10-05 - A070 gRB 05 T13
6,9 gRB 10-06 - A070 gRB 06 T13
6,9 gRB 10-08 - A070 gRB 08 T13
6,9 gRB 10-10 - A070 gRB 10 T13
6,9 gRB 10-12,5 - A070 gRB 12.5 T13
6,9 gRB 10-16 - A070 gRB 16 T13
6,9 gRB 10-20 - A070 gRB 20 T13
6,9 gRB 10-25 - A070 gRB 25 T13
6,9 gRB 10-30 - A070 gRB 30T13
6,9 gRB 10-32 - A070 gRB 32T13
Z330279
X330001
Y330002
Z330003
A330004
B330005
C330006
D330007
E330008
F330009
G330010
H330011
J330012
K330013
L330014
M330015
Y330278
FR10GB69V1
FR10GB69V1.25
FR10GB69V1.5
FR10GB69V2
FR10GB69V2.5
FR10GB69V3
FR10GB69V4
FR10GB69V5
FR10GB69V6
FR10GB69V8
FR10GB69V10
FR10GB69V12.5
FR10GB69V16
FR10GB69V20
FR10GB69V25
FR10GB69V30
FR10GB69V32
* Non approval rating
DC working voltage possibilities
Above: Curve indicating the maximum time constant
L/R of the fault path as a function of the DC voltage U,
for the rated currents from 1 to 30 A of this range.
Time-current characteristics: Curves indicate, for each
rated current, pre-arcing time as a function of RMS
value of pre-arcing current I.
Tolerances on this current:
±10% = ratings from 1 to 6 A
±9% = ratings from 8 to 30 A
Fuses with “gR” characteristics can eliminate all overloads.
They do not show any minimum breaking capacity but limit currents of
non-operation or operation in compliance with standard VDE 636/23.
Cut off characteristics: Curves indicate, for each rated current, the peak
value Ic that the current may reach as a function of prospective fault cur-
rent Ip.
12/04
SCAC
169
Without trip-indicator
Max. weight 10g
Packaging: per 10 pieces
38
±0,6
(1- /
2
”)
10
1
Ø10,3
±0,1
(1.3/32”)
Semiconductor fuses
fuses
Semiconductor (AC)
Other Protistor
®
Fuses
Ferrule Fuses
10x38 URB/URD/URL - 500 to 600 VAC
Extremely high breaking capacity fuses:
Protection of power semiconductors complying with IEC standard
60269.1 and 4.
500 - 600 VAC voltage rating
aR-CLASS according to VDE 636-23 IEC 60269-4
Without blown fuse indication 0.10 up to 0.80 A**
With trip-indicator (1 to 30 A), a Ferraz Shawmut speciality*
Main Characteristics
Voltage
rating
UN( VAC )
Class
Current
rating
IN( A )
Pre-arcing
I
2
t @ 1 ms
I
2
tp (A
2
s)
Total clearing I
2
t @ UN
I
2
tt (A
2
s)
1.2 10
-3
2.3 10
-3
5.2 10
-3
8 10
-3
18 10
-3
33 10
-3
56 10
-3
0.100
0.18
0.44
3.6
1.7
2.2
3.1
5.9
9
16
36
47
80
110
150
200
290
580
900
Watts loss
0.8
I
N
I
N
0.4
0.44
0.48
0.58
0.60
0.73
0.80
0.80
0.90
1
0.5
0.91
1
1.1
1.1
1.5
1.8
1.8
1.35
1.55
1.9
2.3
3.1
3.2
4.25
5.1
Tested
breaking capacity
600 V
without
blown fuse
indicator
URD
**
100
125
160
200
250
315
400
500
630
800
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
0.40
0.13
0.31
0.65
1.65
2.80
5.30
12.7
1.3
2.3
3.6
5.25
9.30
16
37
58
URD
500 V
with
trip-indicator
URD
URL
1A
1.25 A
1.6 A
2A
2.5 A
3.15 A
4A
5A
6A
8A
10 A
12 A
16 A
20 A
25 A
30 A
0.23
0.25
0.28
0.34
0.35
0.42
0.46
0.46
0.52
0.58
2.8
0.52
0.58
0.63
0.63
0.86
1.1
1.1
0.73
0.,83
1
1.3
1.7
1.7
2.9
3.5
200 kA
@ 600 V
50 kA
@ 500 V
50 kA
@ 500 V
50 kA
@ 500 V
* minimum operating voltage for trip-indicator: 20 V
** higher ratings without blown fuse indicator see 10x38gRB - 690 VAC
SCAC
170
12/04