PMUR860
/ MUR860D / MUR860F / MUR860S
SUPERFAST RECOVERY RECTIFIERS
Voltage
Features
Superfast recovery times-epitaxial construction
Low forward voltage, high current capability
Hermetically sealed.
Low leakage
High surge capacity
Plastic package has Underwriters Laboratory
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound
Lead free in compliance with EU RoHS 2011/65/EU directive
Green molding compound as per IEC61249 Std. .(Halogen Free)
600 V
Current
8A
MUR860 TO-220AC
MUR860F ITO-220AC
Mechanical Data
Case: Molded plastic, TO-220AC, ITO-220AC, TO-263, TO-252
Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
Polarity: Color Band denotes cathode end
TO-220AC Approx. Weight: 0.067 ounces, 1.89 grams
ITO-220AC Approx. Weight: 0.055 ounces, 1.56 grams
TO-263 Approx. Weight: 0.051 ounces, 1.46 grams
TO-252 Weight: 0.0104 ounces, 0.297 grams
Marking: Part number
MUR860D TO-263
MUR860S TO-252
Maximum Ratings
(T
A
=25 C unless otherwise noted)
PARAMETER
Maximum repetitive peak reverse voltage
Maximum rms voltage
Maximum dc blocking voltage
Maximum average forward current
Peak forward surge current : 8.3ms single half sine-
wave superimposed on rated load
Maximum forward voltage at 8A
Maximum dc reverse current at rated dc blocking voltage
Operating and storage temperature range
SYMBOL
V
RRM
V
RMS
V
R
I
F(AV)
I
FSM
V
F
I
R
T
J,
T
STG
LIMIT
600
420
600
8
100
1.5
5
-55 to +175
UNIT
V
V
V
A
A
V
A
o
o
C
October 5,2016-REV.02
Page 1
PMUR860
/ MUR860D / MUR860F / MUR860S
Maximum Ratings
(T
A
=25 C unless otherwise noted)
PARAMETER
Maximum reverse recovery time
Typical thermal resistance
(Note 3)
TO-220AC(Note 1)
ITO-220AC (Note 1)
TO-263(Note 1)
TO-252(Note 2)
SYMBOL
T
RR
R
θJC
R
θJC
R
θJC
LIMIT
50
2.5
6.5
5
6.5
o
o
UNIT
ns
C/W
Note : 1. Device mounted on a infinite heatsink, then measured the center of the marking side.
2. Mounted on a 10cm*10cm*1mm copper pad area
3. Reverse Recovery Test Conditions : I
F
=0.5A, I
R
=1A, Recover to 0.25A
C
J
, Junction Capacitance (pF)
I
F
, Forward Current (A)
9
8
100
7
6
5
TO-220AC
4
3
ITO-220AC /
TO-252
TO-263
10
2
1
0
0
25
1
50
75
100
125
150
175
1
10
100
T
C
, Case Temperature (°C)
V
R
, Reverse Bias Voltage (V)
Fig.1 Forward Current Derating Curve
Fig.2 Typical Junction Capacitance
100
100
I
R
, Reverse Current (mA)
I
F
, Forward Current (A)
T
J
= 150°C
10
1
0.1
0.01
0.001
T
J
= 150°C
10
T
J
= 125°C
1
T
J
= 75°C
T
J
= 125°C
T
J
= 75°C
0.1
T
J
= 25°C
T
J
= 25°C
10
20
30
40
50
60
70
80
90 100
0.01
0
0.5
1
1.5
2
Percent of Rated Peak Reverse Voltage (%)
V
F
, Forward Voltage (V)
Fig.3 Typical Reverse Characteristics
Fig.4 Typical Forward Characteristics
October 5,2016-REV.02
Page 2
PMUR860
/ MUR860D / MUR860F / MUR860S
PART NO PACKING CODE VERSION
PART NO PACKING CODE
MUR860_T0_00001
MUR860F_T0_00001
MUR860D_R2_00001
MUR860S_L2_00001
Package Type
TO-220AC
ITO-220AC
TO-263
TO-252
Packing type
50 pcs / Tube
50 pcs / Tube
0.8K pcs / 13" reel
3K pcs / 13" reel
Marking
MUR860
MUR860F
MUR860D
MUR860S
Version
Halogen free
Halogen free
Halogen free
Halogen free
MOUNTING PAD LAYOUT
October 5,2016-REV.02
Page 3
PMUR860
/ MUR860D / MUR860F / MUR860S
October 5,2016-REV.02
Page 4
PMUR860
/ MUR860D / MUR860F / MUR860S
Disclaimer
● Reproducing and modifying information of the document is prohibited without permission from Panjit International Inc..
● Panjit International Inc. reserves the rights to make changes of the content herein the document anytime without
notification. Please refer to our website for the latest document.
● Panjit International Inc. disclaims any and all liability arising out of the application or use of any product including
damages incidentally and consequentially occurred.
● Panjit International Inc. does not assume any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
● Applications shown on the herein document are examples of standard use and operation. Customers are responsible in
comprehending the suitable use in particular applications. Panjit International Inc. makes no representation or warranty
that such applications will be suitable for the specified use without further testing or modification.
● The products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to
human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation
equipment, aerospace machinery et cetera. Customers using or selling these products for use in such applications do so
at their own risk and agree to fully indemnify Panjit International Inc. for any damages resulting from such improper use or
sale.
● Since Panjit uses lot number as the tracking base, please provide the lot number for tracking when complaining.
October 5,2016-REV.02