MAIN FEATURE
1. Low power consumption; AC/DC coil available.
2. Proper insulation distance with 5,000VAC
dielectric strength.
3. UL Class F insulation available.
4. In accordance with IEC 60335-1 and IEC 60730-1.
5. Halogen Free series available.
6. Comply with RoHS and REACH regulations
CONTACT RATING
Load Type
Rated Load (Resistive)
Contact Capacity
Rated Carrying Current
Max. Allowable Voltage
Max. Allowable Current
Max. Allowable Power Force
Contact Material
Contact Form
EMI (DM/DB)
8A 30VDC
-
-
8A
AC 250V
DC 300V
8A
2,000VA
240W
Ag Alloy
DPST
EMI (D)
8A 30VDC
-
-
8A
AC 250V
DC 300V
8A
2,000VA
240W
Ag Alloy
DPDT
EMI (AM/AB)
8A 30VDC
-
-
8A
AC 250V
DC 300V
8A
2,000VA
240W
Ag Alloy
DPST
EMI (A)
EMI (FM/FB)
EMI (F)
8A 250VAC 8A 250VAC 8A 250VAC 8A 250VAC 8A 250VAC 8A 250VAC
8A 30VDC 8A 30VDC 8A 30VDC
-
1/2HP 250VAC 1/2HP 250VAC
-
Pilot Duty R300 Pilot Duty R300
8A
8A
8A
AC 250V
AC 250V
AC 250V
DC 300V
DC 300V
DC 300V
8A
2,000VA
240W
Ag Alloy
DPDT
8A
2,000VA
240W
Ag Alloy
DPST
8A
2,000VA
240W
Ag Alloy
DPDT
Max Allowable Voltage: 300VDC@0.2A
APPLICATION
Cooking Appliance, Audio Equipment, Domestic
Appliance and Controlling Equipment…etc.
PERFORMANCE (AT INITIAL VALUE)
Contact Resistance ..............100 m Max.@1A,6VDC
Operate Time........................12 mSec. Max. (DC coil only)
20 mSec. Max. (AC coil only)
Release Time .......................8 mSec. Max. (DC coil only)
20 mSec. Max. (AC coil only)
Dielectric Strength:
Between Coil & Contact....... 5,000VAC at 50/60 Hz
for one minute
Between Contacts ................1,000VAC at 50/60 Hz
for one minute
Surge Strength: ....................10,000V (between coil
& contact 1.2x50μSec.)
Insulation Resistance...........100M
Min at
500VDC
Max. On/Off Switching:
Electrical ...............................6 Cycles per Minute
Mechanical............................300 Cycles per Minute
Temperature Range .............-40~+85
°C
Humidity Range ....................45~85% RH.
Coil Temperature Rise .........30
°C
Max.
Vibration:
Destruction ...................... 10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
Malfunction ...................... 10 to 55 to 10 Hz,0.75 mm single
amplitude (1.5mm double amplitude)
Shock:
Destruction ...................... 1,000 m/S
2
Malfunction ...................... 100 m/S
Life Expectancy:
5
Electrical .......................... 10 Operations at
Rated Resistive Load
7
Mechanical ...................... 10 Operations at
No load condition
Weight ............................. About 12.5 g
ACCESSORIES & SOCKETS
PI-50BE ........................... See Page 171
PI-50BE/3 ......................... See Page 171
PI-50-0 .............................. See Page 173
SAFETY STANDARD & FILE NUMBER
UL & C-UL
………………… E141060
TÜV ……………………… R50008958
VDE ……………………… 40009648
CQC ……………………… 02001002511