EXCEL CELL ELECTRONIC CO., LTD.
S PE CI F I CAT I O N
NO.
Edition
2
A31229
Page
1
ECS - INDUSTRIAL CONTROL SWITCH
PILOT LAMP
1. FEATURES
Detachable contact block for easy installation and removal. It can meet variety of
needs and improve work efficiency.
IP65 waterproof type. It is designed for liquid and oil prevention and enables to be
used in different environment.
In accordance with the standards of UL, cUL, CE, CCC, and TUV.
2. SPECIFICATIONS
2-1. ELECTRICAL
2-1-1. Rated thermal current
2-1-2. Rated insulation voltage
2-1-3. Dielectric strength
2-2. MECHANICAL AND ENVIRONMENTAL
2-2-1. Operating temperature
2-2-2. Storage temperature
2-2-3. Humidity
2-2-4. Degree of protection
2-2-5. Degree of contamination
2-2-6. Vibration resistance
2-2-7. Shock resistance
2-2-8. Connection type
10A
650V
2500V AC, 1 min.
-25℃ ~ +55℃
(for illuminated type)
-40℃ ~ +85℃
45% ~ 85% RH
IP65 (from the front of the panel)
3 (IEC 60947-5-1)
10-55Hz amplitude 0.5mm
2
1000 m/s (100G)(destruction)
M3.5 screw connection
(60431)2016.06.08
EXCEL CELL ELECTRONIC CO., LTD.
S PE CI F I CAT I O N
3. CONSTRUCTION
NO.
Edition
2
A31229
Page
2
Contact Unit
LED Unit
Operation Unit
Operation unit, LED unit, and contact unit (contact blocks) can be sold separately.
Please see [4.Part numbering system] for operation unit part number. For other
accessories (LED lamp, contact block, etc.), please refer to accessory part in
catalog.
(60431)2016.06.08
EXCEL CELL ELECTRONIC CO., LTD.
S PE CI F I CAT I O N
4.
PART NUMBERING SYSTEM
ECS – XX X L 1 R X – 0 0 2 0 – L XX R
NO.
Edition
2
A31229
Page
3
Lamp color: R(Red) / Y(Yellow) / B(Blue)
G(Green) / W(White)
Applied voltage:06: 6V AC/DC
12: 12V AC/DC
24: 24V AC/DC
A1: 110V AC
A2: 220V AC
Lamp type: L: LED
Contact block special number:
0: n/a
Function:
2: lamp modular
Contact configuration:
00: without contact blocks
Operator special number:
Blank: n/a
Cover color: R(Red) / Y(Yellow) / B(Blue) / G(Green)
W(White) / O(Orange)
Type:
1: Low-profile type
3: Extended type
Operator:
L: Pilot Lamp
Appearance:
R: Round
Q: Square
(only for 22 & 25 mm)
Mounting hole dia. :
22: Ø 22 mm
25: Ø 25 mm
30: Ø 30 mm
Series: ECS: Industrial Control Switch
(60431)2016.06.08
EXCEL CELL ELECTRONIC CO., LTD.
S PE CI F I CAT I O N
NO.
Edition
2
A31229
Page
4
5. INSTALLATION
5-1. Panel thickness
The panel thickness must be 1 to 7 mm.
Take into consideration about the thickness of accessories
(such as name plate, switch guard, etc.) while using.
5-2. Panel cutout
Cutout diameter and distance
Unit: mm
22R / 25R
A
22.3/25.3
- 0
22R / 25R
X
Y
30
50
+0.4
22Q / 25Q
22.3/25.3
- 0
22Q / 25Q
32
50
+0.4
30R
30.5
- 0
30R
50
65
+0.5
Unit: mm
Long Lever Selector Switch
Emergency Stop Switch
50
50
Key recess cutout (22mm only)
Unit: mm
Mounting Hole(Ø)
22
Panel installation
a
24.1
- 0
+0.5
b
3.2
- 0
+0.2
1. Place the operation unit through
panel mounting hole.
2.
Install the nut by using tightening
tool.
3.
Make sure the operation unit fix
on the panel firmly.
5-3. Operation unit and contact unit installation
1. Fix the operation unit on the
panel.
2.
Connect the operation unit with
snap-fit joint part of contact unit.
3.
Rotate contact unit to fix firmly
as shown in the left figure.
(60431)2016.06.08
EXCEL CELL ELECTRONIC CO., LTD.
S PE CI F I CAT I O N
5-4. LED lamp installation
NO.
Edition
2
A31229
Page
5
1. Aim LED lamp to the lamp holder and
press down to the bottom.
2. Rotate the LED lamp to make sure the
lamp is firmly installed.
3. While installation and removal, please
hold the metal part of LED lamp to
avoid damaging LED lamp.
1.
2.
When using DC LED lamp, please
connect the positive pole (+) to X1
terminal as shown in left figure.
The LED lamp may be erroneously
lightened by a leaking current from
the circuit. The malfunction can be
prevented by connecting a shunt
resistor in parallel with the LED lamp.
6. PACKAGING
6-1 . ECS product is packed without assembly (packed by set), 10 sets per box.
6-2 . Label information
(1) part number
(6) QC inspection stamp
(2) Lot number
(7) Company mark
(3) Quantity
(8) Company name
(4) Tester number
(9) Notice
(5) Date code
7. DIMENSIONS
7-1. See attached drawings
8. OPTIONS
8-1. Key recess type operation unit is available (22mm only)
8-2. Ø22mm and Ø25mm type have the same structure. Different thickness of O-rings
can be ordered separately to fit into Ø22mm and Ø25mm hole in the panel.
8-3. LED Specification
LED Type
Durability(reference)
Voltage
BA9S-T8
Approx. 50,000 Hrs.
Printed on the LED
8-4. For other accessories (name plate, control box, and etc.), please refer to
accessory part in the catalog.
(60431)2016.06.08