Surge arrester
2-Electrode arrester
Series/Type:
Customer:
Version/Date:
DG2R420M
Issue 01/2017-04-12
DC Elec. 2017.
Reproduction,publication and dissemination of this document, enclosures here to and the
information contained therein without DC' prior express consent is prohibited.
2-Electrode arrester
Features
●
●
●
●
●
●
●
●
DG2R420M
Applications
●
●
●
●
Extremely small size
Extremely fast response time
Eexcllent SMD handing
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
UL-identification, No:E311500
Splitter
PCI Cards
Morden
Line cards
Electrical specifications
DC breakdown voltage
2) 3)
at 100v/s
-Circuit current less than 2mA
Impulse breakdown voltage
1)
at 1kv/us
-Typical values of distribution
Insulation resistance at DC 100V
Capacitance at 1MHz
2)
Service life
2)
10 operations
1 operations
400
±20
≤650
≥1
≤1
2.5
5
~0.4
-40…+90
40/90/21
2R420
V
%
V
GΩ
Pf
KA
KA
g
°C
8/20us
8/20us
Weight
Storage and operations temperature
Climatic category(GB/T 9043,IEC61643-1)
Marking,Blue positive
Tel:
Fax:
+86-510-81707285
+86-510-81707277
www.jsdgme.com
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue01/2017-04-12
Page 2 of 4
2-Electrode arrester
DG2R420M
8/20us, Test wave
T1=1.25T=8us±20%
T2=20us±20%
10/700us,Test Wave
T1=1.67T=10us±20%
T2=700us±20%
10/1000us,Test Wave
T1=1.67T=10us±20%
T2=1000us±20%
Recommended wave slodering profile
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Page 3 of 4
Issue01/2017-04-12
2-Electrode arrester
1)
2)
3)
Sampling size in accordance to AQL(C=0)
DC spark-over voltage ±30% after load
Tests according to ITU-T Rec. K. 12 and IEC61643-1
DG2R420M
Dimensions
Wire Tin-plated
Packaging
One reel with 800pcs
Cautions and warnings
●
●
●
●
Surge arresters must not be operated directly in power supply networks
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
If the contacts of the surge arrester are defective, current stress can lead to the formation of
sparks and loud noises.
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
Issue01/2017-04-12
Page 4 of 4
●
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.