Power Inductors
Specification for Approval
Customer:
Customer P/N:
Product Name:
Coilank P/N:
立创
C328275
Power Inductors
APD04T30M4R7
[
New Released,
Approved by
Revised]
Checked by
Prepared by
Jean.Lin
Bruce.lan
Coilank Technology Co., Ltd
ADD: No.39,Chingao Rd.,(305)Hsinpu,Hs inchu Hsien Taiwan,R.O.C
TEL : 00886-3-5894523 FAX : 00886-3-5894415
ADD: Unit D, 16/F Cheuk Nang Plaze 250 Hennessy Road, Wanchai HongKong
TEL : 00852-31135161 FAX : 00852-31121631
SZ Office TEL : 0755-29452870/3 FAX : 0755-61658369
HTTP : www.coilank.com
E-mail :
sales@coilank.com
【For
Customer approval Only】
Qualification Status:
Full
Date:
Restricted
Rejected
Approved By
Verified By
Checked By
Comments:
Http://www.coilank.com
E-mail:sales@coilank.com
Power Inductors
Change Note
Version
Comtent
Draw
Check
Approval
Date
Coding
1
New Design
Bruce.lan
Jean.lin
Jean.lin
2019.04.18
S153
Http://www.coilank.com
E-mail:sales@coilank.com
Power Inductors
1.
External Dimensions (Unit:m/m)
B
C
F
D
H
I
E
G
A
Type
APD04T30
A
3.8±
0.3
B
3.8±
0.3
C
2.8±
0.3
D
5.2Max
E
1.1Ref
F
1.5Ref
G
1.4Ref
H
5.2Ref
I
2.4Ref
Q’TY/Reel
2000
2.
Part Number Code
APD
A
A:
B:
C:
D:
E:
F:
04
B
T
C
30
D
M
E
4R7
F
Power Inductors
04:3.8x3.8
T:T type
30:2.8
M:±
20%
4R7=4.7uH
Series Name
Dimensions(mm)
Materials
Thickness(mm)
Tolerance
Inductance
3.
Electrical Characteristics
Part Number
APD04T30M4R7
Inductance
(uH)
4.7
Test Frequency
(KHz)
100KHz/0.25V
DC Resistance
(mΩ)Max.
88.0
Saturation Current
(A)Max.
1.65
Notes:
1)AEC-Q200 qualified.
2)All test data is referenced to 25℃ ambient.
3)Operating temperature range -40℃ to +125℃.
4)lsat :DC current(A) that will cause lo to drop approximately 35%.
5)The part temperature(ambient + temp rise)should not exceed 125℃ under worst case operating
conditions. circuit design,component placement, PWB trace size and thickness,airflow and other
cooling provisions all affect the part temperature,part temperature should be verified in the end
application.
Http://www.coilank.com
E-mail:sales@coilank.com
Power Inductors
4.
Test Data
ELECTRICAL CHARCTERISTIC
SPEC
TOL
NO
1
2
3
4
5
6
7
8
9
10
L(uH)
4.7
±
20%
4.58
4.45
4.54
4.52
4.35
4.46
4.54
4.35
4.54
4.42
DCR(mΩ)
88.0
Max
62.24
61.58
61.26
61.47
62.18
60.59
61.88
61.07
62.91
62.37
Isat(uH)
1.65A
(L0A-L1.65A)
/L0A≤35%
3.63
3.62
3.55
3.63
3.59
3.54
3.62
3.56
3.64
3.61
A(mm)
3.8
±0.3
4.04
4.02
4.02
4.03
4.04
4.03
4.02
4.06
4.02
4.01
MECHANICAL DIMENSIONS
B(mm)
3.8
±0.3
4.03
4.05
4.01
4.03
4.02
4.04
4.01
4.06
4.07
4.02
C(mm)
2.8
±0.3
2.87
2.80
2.87
2.86
2.87
2.89
2.80
2.88
2.87
2.81
E(mm)
1.1
Ref
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
Test Equipmets: IM3536,VR126,VR7210,Calipers
5.
Test and Measurement Procedures
5.1 Test Conditions
5.1.1 Unless otherwise specified, the standard atmospheric conditions for measurement/test as:
a. Ambient Temperature: 20±
15℃
b. Relative Humidity: 65%±
20%
c. Air Pressure: 86KPa to 106KPa
5.1.2 If any doubt on the results, measurements/tests should be made within the following limits:
a. Ambient Temperature: 20±
2℃
b. Relative Humidity: 65%±
5%
c. Air Pressure: 86KPa to 106Kpa
5.2 Visual Examination
a. Inspection Equipment: 10X magnifier
5.3 Electrical Test
5.3.1 Inductance (L)
a. Refer to the third item.
b. Test equipment: IM3536 LCR meter or equivalent.
c. Test Frequency and Voltage: Refer to the third item.
5.3.2 Direct Current Resistance (DCR)
a. Refer to the third item.
b. Test equipment: VR126 or equivalent.
5.3.3 Current
a. Refer to the third item.
b. Test equipment (see Fig.5.3.3-1): Electric Power, Electric current meter, Thermometer.
c. Measurement method (see Fig. 5.3.3-1):
Http://www.coilank.com
E-mail:sales@coilank.com
Power Inductors
1. Set test current to be 0 mA.
2. Measure initial temperature of chip surface.
3. Gradually increase voltage and measure chip temperature for corresponding current.
d. Definition of Temperature rise current: DC current that causes the temperature rise (△ T =40°
C)
from 20° ambient (see Fig. 5.3.3-2).
C
Fig.5.3.3-1
Fig.5.3.3-2
5.4 Reliability Test
Item
Specifications
Test conditions
Temperature: 125±2℃.
Duration:1000hrs.
Measured at room temperature after
placing for 24± hrs.
4
5.4.1
High temperature storage
test
No visible mechanical damage.
Inductance change: Within ±
10%.
Condition for 1 cycle.
Step1:-40±2℃ 30min Min.
Step2:125±2℃, transition time 1min Max.
Step3:125±2℃ 30min Min.
Step4:Low temp, transition time 1min Max.
Number of cycles:1000.
Measured at room temperature after placing for 24±
4
hrs.
5.4.2
Temperature cycling test
No visible mechanical damage.
Inductance change: Within ±
10%.
5.4.3
Biased humidity test
No visible mechanical damage.
Inductance change: Within ±
10%.
Humidity :85﹪±3 RH.
Temperature:85℃±2℃.
Duration : 1000hrs.
Measured at room temperature after
placing for24± hrs.
4
Http://www.coilank.com
E-mail:sales@coilank.com