H U IK E
1.
,安全认证:
Safety Standard:
2.
接点规格:
Contact Specification:
2.1
接点间隙:
Contact Gap:
2.2
接点阻抗:
Contact Resistance
最小
0.25 mm。
0.25 mm Minimum.
初始值最大
100mΩ;
流通电流
1A、开路测试电压: 6VDC;
½用电压下降法量测。
Maximum 100mΩ at initial value.
Test Current: 1A, Open Circuit Test Voltage: 6VDC.
By using Voltage Drop Method.
250VAC Cosφ=1,可通过电流为 5
安培。
14VDC
,可通过电流为
20
安培。
5 Amps at 250VAC Cosφ=1.
20 Amps at 14VDC
C-UL
CQC
TUV
HKV6
Page:
1
2.3
接点容量:
Contact Capacity:
3.
摄氏
20
度之线圈规格:
Coil Specification at 20 °C:
3.1
额定电压:
Rated Voltage:
3.2
额定电流:(
mA± 10%)
Nominal Current:
3.3
额定消耗功率:
(± 10%.)
Rated Power Consumption:
3.4
线圈阻抗:
(Ω± 10%.)
Coil Resistance:
3.5
感动电压:
Pull In Voltage:
3VDC.
200/268
5VDC.
119/156
6VDC.
100/133
9VDC.
67/89
12VDC.
50/67
24VDC.
25/33
0.6W / 0.8W
15/11.2
42/31.3
60/45
135/101
240/180
960/720
≦
(½电压渐渐½加于继电器时接点之动½电压,为额定电压之 60%)
V DC
≦
(Contact operating voltage when voltage is gradually applied. It is
75% of the Rated Voltage) V DC
≧
(½额定电压渐渐的减少时接点放开之电压,为额定电压之 10%) VDC
≧
(Contact breaking voltage when rated voltage is gradually reduced.
It is 10% of the Rated Voltage) VDC
(为额定电压之 130%) V DC
(130% of the Rated Voltage) V DC
在½加额定电压时最大为
10 milliseconds。
10 milliseconds Maximum when rated Voltage is applied.
3.6
开放电压:
Drop Out Voltage:
3.7
最大应加电压:
Max. Allowable Voltage:
3.8
动½时间:
Operate Time:
中½浙江宁波市鄞州区姜山镇新塘沿工业开发区
Jiangshan Town Yinzhou
Ningbo Zhjiang
China
宁波汇科新纪元电器有限公司
FAX:( 0574)
88457928
Ningbo Huike New Era Elierical Appliances Co.,Ltd
TEL:
(
0574
)
88457918
88457948
H U IK E
3.9
开放时间
Release Time:
3.10
线圈温升:
Coil Temperature Rise:
HKV6
Page:
2
在额定电压突然消失时最大为
10 milliseconds.。
10 milliseconds Maximum when rated Voltage is suddenly cut off.
在空½½时线圈½加最大可允许电压,待温度稳定后量测的温度不可超过
40℃。(不包含环境温度)
40℃ Maximum.
Maximum Allowable Voltage is applied to Coil while no load should be
applied to Contacts, then the temperature should be measured when
the value is stabilized. Environment temperature should not be
included in.
4.
电气特性:
Electrical Characteristics:
4.1
½用寿½:
Life Expectancy:
4.1.1
电气寿½:
Electrical Life:
5A/250VAC Cosφ=1,½加额定电压时,有 100,000
次以上之电气寿½。
20A/14VDC
,½加额定电压时,有
100,000
次以上之电气寿½。
100,000 operations Minimum at 5A/250VAC Cosφ=1.
100,000 operations Minimum at20A/14VDC
Rated Voltage is applied.
在无负½½的情况下有
10,000,000
次以上之机械寿½。
10,000,000 operations Minimum at No Load condition.
电气: 每分钟
30
次。
机械: 每分钟
300
次。
Electrical: 30 operations/minute.
Mechanical: 300 operations/minute.
4.1.2
机械寿½:
Mechanical Life:
4.1.3
最大操½频率
Maximum Operating
Frequency:
4.2
介质耐压:
Dielectric Strength:
4.2.1
接点对接点间:
Between Contacts:
500VAC,50/60 Hz,漏电流小于 1mA,持续一分钟。
500VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1
minute.
500VAC,50/60 Hz,漏电流小于 1mA,持续一分钟。
500VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1
minute.
在½加
500VDC
绝缘阻抗之量测值需≧1000
MΩ。
≧1000
MΩ Minimum.
A Voltage of 500VDC should be applied after which measurement shall
be made.
4.2.2
线圈对接点间:
Between Coil &
Contact:
4.3
绝缘阻抗:
Insulation Resistance:
中½浙江宁波市鄞州区姜山镇新塘沿工业开发区
Jiangshan Town Yinzhou
Ningbo Zhjiang
China
宁波汇科新纪元电器有限公司
FAX:( 0574)
88457928
Ningbo Huike New Era Elierical Appliances Co.,Ltd
TEL:
(
0574
)
88457918
88457948
H U IK E
4.4
振动测试:
Vibration
4.4.1
振动
I(强度):
Endurance I:
HKV6
Page:
3
在无激磁状态下双振幅½度为
1.5mm,震动频率在一分钟内由
10HZ~55HZ~10HZ。XYZ
各方向各进行
2
小时,共六小时,实验后外观
构造不可异常,且电气功½需符合规格之要求。
The Coil shall be maintained under not energized condition, double
amplitude 1.5 mm, the entire frequency range changes from 10 to 55 Hz
then returns to 10 Hz shall be made in 1 minute. This motion shall be
applied for a period of 2 hours in each of 3 mutually perpendicular axis
(a total of 6 hours) There should not be any deformations in
construction and in appearance, while the Electrical Specifications
should be fulfilled after the test.
在激磁状态下双振幅½度是
1.5mm,震动频率在一分钟内由
XYZ
各方向进行
5
分钟,
实验中不得有误(接点断开
10HZ~55HZ~10HZ。
时间不可超过
1 mS)。实验后外观,构造不可异常,且电气功½需符合规
格之要求。
The Coil shall be maintained under energized condition, double
amplitude 1.5 mm, the entire frequency range changes from 10 to 55 Hz
then returns to 10 Hz shall be made in 1 minute. This motion shall be
applied for a period of 5 minutes in 3 mutually perpendicular axis.
Malfunction is not allowed during the test (contact breaking time should
be less than 1 millisecond) In addition, there should not be any
deformations in construction and in appearance while the Electrical
Specifications should be fulfilled after the test.
4.4.2
振动
II (稳定性):
Endurance II (Error
Operation):
4.5
冲击测试:
Shock:
4.5.1
耐冲击性
I(强度):
Endurance I:
在无激磁状态加速度
1000m/s
2
冲击情况下,XYZ 各方向进行
5
次,实验
后外观,构造不可异常,且电气功½需符合规格之要求。
Peak Acceleration: 1000m/s
2
The Coil shall be maintained under not energized condition, 5
successive shocks shall be applied in 3 mutually perpendicular axis.
There should not be any deformations in construction and in
appearance while the Electrical Specifications should be fulfilled after
the test.
在激磁状态加速度
100m/s
2
冲击情况下,XYZ 各方向进行
2
次,实验中
不得有误(接点断开时间不可超过
1 mS),实验后外观,构造不可异常,
且电气功½需符合规格之要求。
Peak Acceleration: 100m/s
2
The Coil should be maintained under energized condition, 2 successive
shocks shall be applied in 3 mutually perpendicular axis. Malfunction
is not allowed during the test (contact breaking time should be less than
1 millisecond) In addition, there should not be any deformations in
construction and in appearance while the Electrical Specifications
should be fulfilled after the test.
4.5.2
耐冲击性
II (稳定性):
Endurance II (Error
Operation):
中½浙江宁波市鄞州区姜山镇新塘沿工业开发区
Jiangshan Town Yinzhou
Ningbo Zhjiang
China
宁波汇科新纪元电器有限公司
FAX:( 0574)
88457928
Ningbo Huike New Era Elierical Appliances Co.,Ltd
TEL:
(
0574
)
88457918
88457948
H U IK E
5.
环境特性:
Environmental
Characteristics:
5.1
温度范围:
Temperature Range:
5.1.1
½用温度范围:
Operating
Temperature Range:
HKV6
Page:
4
-30 to + 85°C。
½用温度范围是代表继电器在线圈之动½电压范围内可以持续动½的温
度范围(在½温时无水滴凝结现象)
Operating temperature range is the range of ambient temperature of
which the Relay can be operated continuously within operative voltage
range of coil (no condensation of water drops under low temperature
condition)
-30 to + 850°C.
储存温度范围是代表继电器在没有损伤的情况下可以被储存的温度范围
(在½温时无水滴凝结现象)。储存的情况在本 SPEC
其它地方所示。
Storage temperature range is the range of ambient temperature of
which the Relay can be stored without damages (no condensation of
water drops under low temperature condition). Conditions are as
specified elsewhere in these specifications.
35~85% RH.
5.1.2
储存温度范围:
Storage Temperature
Range:
5.2
湿度范围:
Humidity Range:
5.3
耐寒性:
Cold Resistance:
5.3.1
½用耐寒性:
Cold Resistance in
Use:
继电器不给予电压或电流状态下,在恒温箱以-25
± 2°C
的温度连续保持
2
小时。保持原状态操½回路上给予定格电压实验时继电器动½要正常。
(在½温时无水滴凝结现象)
Relay should be kept in temperature chamber at -30 ± 2°C for two hours
that no current or voltage shall be supplied to Relay. Such condition
shall be maintained while the rated voltage is supplied to Relay, then the
Relay shall operate normally. (No condensation of water drops under
low temperature condition)
继电器在恒温箱以-25
± 2°C
的温度连续保持
72
小时。
接着,
于常温常湿
中消除水滴
1
至
2
小时以后,进行构造,动½,及绝缘阻抗,耐压的测
试,结果需要符合
SPEC。(在½温时无水滴凝结现象)
Relay should be kept in temperature chamber at -40 ± 2°C for 72 hours.
Then the Relays shall be maintained at standard atmospheric condition
for 1 to 2 hours after which measurement shall be made.
Construction, Relay operation, Insulation Resistance and Dielectric
Strength shall satisfy the specification requirements. (No
condensation of water drops under low temperature condition)
5.3.2
储存耐寒性:
Storage Cold
Resistance:
5.4
耐热性:
Heat Resistance:
中½浙江宁波市鄞州区姜山镇新塘沿工业开发区
Jiangshan Town Yinzhou
Ningbo Zhjiang
China
宁波汇科新纪元电器有限公司
FAX:( 0574)
88457928
Ningbo Huike New Era Elierical Appliances Co.,Ltd
TEL:
(
0574
)
88457918
88457948
H U IK E
5.4.1
½用耐热性:
Heat Resistance in
Use:
HKV6
Page:
5
继电器操½回路提供定格电压,
在接点部½提供定格电流的状态下,
在恒
温箱以
70 ± 2°C
的温度连续保持
2
小时后,保持原状态进行继电器动½
之测试,结果必须符合
SPEC。
Relay should be kept in temperature chamber at 70 ± 2°C for two hours
that rated Voltage should be supplied to Coil while rated Current should
be supplied to Contacts. Such condition shall be maintained while the
rated voltage is supplied to Relay, then Relay shall operate normally.
继电器在恒温箱以
70 ± 2°C
的温度连续保持
16
小时,在常温,常湿状态
下,放½
1-2
小时后,进行构造,动½,及绝缘阻抗,耐压的测试,结果
需要符合
SPEC。
Relay should be kept in temperature chamber at 70 ± 2°C for 16 hours.
Then the Relays shall be maintained at standard atmospheric condition
for 1 to 2 hours after which measurement shall be made.
Construction, Relay operation, Insulation Resistance and Dielectric
Strength shall satisfy the specification requirements.
继电器以温度
30 ± 2°C
相对温度在
85%环境下连续保持 48
小时,接着,
于常温常湿放½
1-2
小时后,
进行构造,
动½,
及绝缘阻抗,
耐压的测试,
结果需要符合
SPEC。
Relay should be kept in temperature chamber at 40 ± 2°C (90~95% RH)
for 48 hours. Then the Relays shall be maintained at standard
atmospheric condition for 1 to 2 hours after which measurement shall
be made. Construction, Relay operation, Insulation Resistance,
Dielectric Strength shall satisfy the specification requirements.
5.4.2
储存耐热性:
Storage Heat
Resistance
5.5
耐湿性:
Moisture Resistance:
6.
端脚特性:
Terminal Characteristics:
6.1
端脚强度:
Terminal Strength:
在水平方向负重
300
克持续
1
分钟,测试完成后端脚不½有任½的松脱
或是弯曲。
A load of 300g should be applied to the Terminal for one minute in
horizontal direction. There should not be any looseness or bending of
Terminals.
温度
230 ± 5°C,时间 3 ± 0.5
秒,浸渍端子前端
3mm,须沾锡面积需达
90%以上。
The front 3 mm of Terminal should be immersed for 3 ± 0.5 seconds at
230 ± 5°C. Soldered area must be minimum 90% of the soldering
surface.
½端脚浸到
350°C
的锡炉内
3
秒钟时,继电器必须½符合所有的电气与
机械规格之要求,且外观不会有改变。
When the Terminal are immersed into soldering bath at 350 °C for 3
seconds, the Relay shall satisfy all electrical and mechanical
specifications and must not have excessive change in outside
appearance.
约
6
克
Approx.6g
GB2828-2000
之½样标准中,以一般检查水准
II
级
AQL – 0.4
为依据。
GB2828-2000 Level – General II, AQL 0.4.
6.2
沾锡测试:
Soldering Dip Test:
6.3
沾锡耐热性:
Soldering Heat Resistance:
7.
重量:
Weight:
8. ½样检查标准:
Sample Test Method:
中½浙江宁波市鄞州区姜山镇新塘沿工业开发区
Jiangshan Town Yinzhou
Ningbo Zhjiang
China
宁波汇科新纪元电器有限公司
FAX:( 0574)
88457928
Ningbo Huike New Era Elierical Appliances Co.,Ltd
TEL:
(
0574
)
88457918
88457948