Surge Arrester
2-Electrode Ceramic Surge Arrester
2R600A5L
2R Ceramic Surge Arresters
SPECIFICATION
Changzhou Wujin Jiangnan Discharge Tube Co.,Ltd
Add:Zouqu Town Industrial Zone,Wujin Changzhou City,Jiangsu,China
Tel:0519-83631254
Fax:0519-83631533
Email:jiangnan@jiangnan-cn.cn
第
1
页 共
3
页
Surge Arrester
2-Electrode Ceramic Surge Arrester
2R600A5L
·Electrical
Characteristics
DC spark-over voltage
Impulse spark-over voltage
at 100V/μs - for 99% of measured values
-typical values of distribution
at 1 kV/μs - for 99% of measured values
- typical values of distribution
Service life
10 operations
10 operations
1 operation
1 operation
Insulation resistance at
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Marking, blue
2R
600
Type: 2R600A
5
L
600
±20
<1000
<900
<1200
<1100
10
10
15
1
>10
<1.5
~10
~0.5
~60
~1.5
-40…+125
V
%
V
V
V
V
A
kA
kA
kA
GΩ
pF
V
A
V
g
℃
50 Hz, 1 s
8/20 µs
8/20 µs
10/350 µs
250 Vdc
2R600
-Two Electrode
-Nominal voltage
第
2
页 共
3
页