HT23F
Page:
1
宁波博粤电子有限公司
产品承认书
品牌:
型号:
客户:
日期:
Htv
继电器
HT23F
供应商签章
客户确认签章
---------------------------------------------------------------------------------------------------------------------------
宁波博粤电子有限公司
宁波市鄞州区四明中路688号 TEL:0574-88120933 FAX:0574-88120533
HT23F
Page:
2
1.
安全认证:
Safety Standard:
C-UL
2.
接点规格:
Contact Specification:
2.1
接点间隙:
Contact Gap:
2.2
接点阻抗:
Contact Resistance
最小
0.15 mm。
0.15mm Minimum.
初始值最大
100mΩ;
流通电流
1A、开路测试电压: 6VDC;
½用电压下降法量测。
Maximum 100mΩ at initial value.
Test Current: 1A, Open Circuit Test Voltage: 6VDC.
By using Voltage Drop Method.
125VAC Cosφ =1,可通过电流为 1
安培。
30VDC
,可通过电流为
2
安培。
1Amps at 125VAC Cosφ =1.
2 Amps at 30VDC .
2.3
接点容量:
Contact Capacity:
3.
摄氏
20
度之线圈规格:
Coil Specification at
20 °
C:
3.1
额定电压:
3VDC.
5VDC.
6VDC.
9VDC.
12VDC.
Rated Voltage:
3.2
额定电流:(
mA± 10% )
50/67/120 29.9 /40/72 25/33.3/60 16.7/22.5/40 12.5/16.7/30
Nominal Current:
3.3
额定消耗功率:
(±
10%.)
0.15W/0.2W0.36W
Rated Power
Consumption:
24VDC.
6.25/8.3/15
---------------------------------------------------------------------------------------------------------------------------
宁波博粤电子有限公司
宁波市鄞州区四明中路688号 TEL:0574-88120933 FAX:0574-88120533
HT23F
Page:
3
3.4
线圈阻抗:
(Ω± 10%.)
Coil Resistance:
3.5
感动电压:
Pull In Voltage:
60/45/25 167/125/70 240/180/100 540/400/220 960/720/400 3840/2880/1600
≦
(½电压渐渐½加于继电器时接点之动½电压,为额定电压之 80%)
V DC
≦
(Contact operating voltage when voltage is gradually applied. It is 80% of
the Rated Voltage) V DC
≧
(½额定电压渐渐的减少时接点放开之电压,为额定电压之 10%) VDC
≧
(Contact breaking voltage when rated voltage is gradually reduced. It is
10% of the Rated Voltage) VDC
(为额定电压之 130%) V DC
(130% of the Rated Voltage) V DC
3.6
开放电压:
Drop Out Voltage:
3.7
最大应加电压:
Max. Allowable
Voltage:
3.8
动½时间:
Operate Time:
3.9
开放时间
Release Time:
3.10
线圈温升:
Coil Temperature
Rise:
在½加额定电压时最大为
5 milliseconds。
5 milliseconds Maximum when rated Voltage is applied.
在额定电压突然消失时最大为
5 milliseconds.。
5 milliseconds Maximum when rated Voltage is suddenly cut off.
在空½½时线圈½加最大可允许电压,
待温度稳定后量测的温度不可超过
40℃。
(不
包含环境温度)
40℃ Maximum.
Maximum Allowable Voltage is applied to Coil while no load should be applied to
Contacts, then the temperature should be measured when the value is
stabilized. Environment temperature should not be included in.
4.
电气特性:
Electrical
Characteristics:
4.1
½用寿½:
Life Expectancy:
4.1.1
电气寿½:
Electrical Life:
1A/125VAC Cosφ =1,½加额定电压时,有 100,000
次以上之电气寿½。
2A/30VDC
,½加额定电压时,有
100,000
次以上之电气寿½。
100,000 operations Minimum at 1A/125VAC Cosφ =1.
100,000 operations Minimum at2A/30VDC
Rated Voltage is applied.
在无负½½的情况下有
10,000,000
次以上之机械寿½。
10,000,000 operations Minimum at No Load condition.
电气: 每分钟
30
次。
机械: 每分钟
300
次。
Electrical: 30 operations/minute.
Mechanical: 300 operations/minute.
4.1.2
机械寿½:
Mechanical Life:
4.1.3
最大操½频率
Maximum
Operating
Frequency:
---------------------------------------------------------------------------------------------------------------------------
宁波博粤电子有限公司
宁波市鄞州区四明中路688号 TEL:0574-88120933 FAX:0574-88120533
HT23F
Page:
4
4.2
绝缘耐压:
Dielectric Strength:
4.2.1
接点对接点间:
Between
Contacts:
4.2.2
线圈对接点间:
Between Coil &
Contact:
4.3
绝缘阻抗:
Insulation
Resistance:
400VAC,50/60 Hz,漏电流小于 1mA,持续一分钟。
400VAC at Test Frequency 50/60 Hz, Leakage Current: 5mA for 1 minute.
1,000VAC,50/60 Hz,漏电流小于 1mA,持续一分钟。
1,000VAC at Test Frequency 50/60 Hz, Leakage Current: 5mA for 1 minute.
在½加
500VDC
绝缘阻抗之量测值需≧100
MΩ。
≧100
MΩ Minimum.
A Voltage of 500VDC should be applied after which measurement shall be
made.
4.4
震动测试:
Vibration
4.4.1
耐震性
I:
Endurance I:
在无激磁状态下双振幅½度为
1.5mm,震动频率在一分钟内由
10HZ~55HZ~10HZ。XYZ
各方向各进行
2
小时,共六小时,实验后外观构造不
可异常,且电气功½需符合规格之要求。
The Coil shall be maintained under not energized condition, double amplitude
1.5 mm, the entire frequency range changes from 10 to 55 Hz then returns to 10
Hz shall be made in 1 minute. This motion shall be applied for a period of 2
hours in each of 3 mutually perpendicular axis (a total of 6 hours) There should
not be any deformations in construction and in appearance, while the Electrical
Specifications should be fulfilled after the test.
在激磁状态下双振幅½度是
1.5mm,
震动频率在一分钟内由
10HZ~55HZ~10HZ。
XYZ
各方向进行
5
分钟,实验中不得有误(接点断开时间不可超过
1 mS)。实验后
外观,构造不可异常,且电气功½需符合规格之要求。
The Coil shall be maintained under energized condition, double amplitude 1.5
mm, the entire frequency range changes from 10 to 55 Hz then returns to 10 Hz
shall be made in 1 minute. This motion shall be applied for a period of 5
minutes in 3 mutually perpendicular axis. Malfunction is not allowed during the
test (contact breaking time should be less than 1 millisecond) In addition, there
should not be any deformations in construction and in appearance while the
Electrical Specifications should be fulfilled after the test.
4.4.2
耐震性
II (误动
½):
Endurance II
(Error
Operation):
4.5
冲击测试:
Shock:
4.5.1
耐冲击性
I:
Endurance I:
在无激磁状态加速度
1000m/s
2
冲击情况下,XYZ 各方向进行
5
次,实验后外观,
构造不可异常,且电气功½需符合规格之要求。
Peak Acceleration: 1000m/s
2
The Coil shall be maintained under not energized condition, 5 successive
shocks shall be applied in 3 mutually perpendicular axis. There should not be
any deformations in construction and in appearance while the Electrical
Specifications should be fulfilled after the test.
---------------------------------------------------------------------------------------------------------------------------
宁波博粤电子有限公司
宁波市鄞州区四明中路688号 TEL:0574-88120933 FAX:0574-88120533
HT23F
Page:
5
4.5.2
耐冲击性
II (误
动½):
Endurance II
(Error
Operation):
在激磁状态加速度
100m/s
2
冲击情况下,XYZ 各方向进行
2
次,实验中不得有误
(接点断开时间不可超过 1 mS),实验后外观,构造不可异常,且电气功½需符合
规格之要求。
Peak Acceleration: 100m/s
2
The Coil should be maintained under energized condition, 2 successive shocks
shall be applied in 3 mutually perpendicular axis. Malfunction is not allowed
during the test (contact breaking time should be less than 1 millisecond) In
addition, there should not be any deformations in construction and in
appearance while the Electrical Specifications should be fulfilled after the test.
5.
环境特性:
Environmental
Characteristics:
5.1
温度范围:
Temperature Range:
5.1.1
½用温度范围:
Operating
Temperature
Range:
-30 to + 75°
C。
½用温度范围是代表继电器在线圈之动½电压范围内可以持续动½的温度范围
(在½温时无水滴凝结现象)
Operating temperature range is the range of ambient temperature of which the
Relay can be operated continuously within operative voltage range of coil (no
condensation of water drops under low temperature condition)
-30 to + 70°
C.
储存温度范围是代表继电器在没有损伤的情况下可以被储存的温度范围(在½温
时无水滴凝结现象)。储存的情况在本
SPEC
其它地方所示。
Storage temperature range is the range of ambient temperature of which the
Relay can be stored without damages (no condensation of water drops under
low temperature condition). Conditions are as specified elsewhere in these
specifications.
35~85% RH.
5.1.2
储存温度范围:
Storage
Temperature
Range:
5.2
湿度范围:
Humidity Range:
5.3
耐寒性:
Cold Resistance:
5.3.1
½用耐寒性:
Cold Resistance
in Use:
继电器不给予电压或电流状态下,在恒温箱以-30
± 2°
的温度连续保持
2
小时。
C
保持原状态操½回路上给予定格电压实验时继电器动½要正常。(在½温时无水滴
凝结现象)
Relay should be kept in temperature chamber at -30 ± 2° for two hours that no
C
current or voltage shall be supplied to Relay. Such condition shall be
maintained while the rated voltage is supplied to Relay, then the Relay shall
operate normally. (No condensation of water drops under low temperature
condition)
---------------------------------------------------------------------------------------------------------------------------
宁波博粤电子有限公司