ISO9001: 2000
ISO14001: 2004
APPROVAL SPECIFICATIONS
Title.
Product Model.
TACT SWITCH
KAN0631K
Customer’s Part NO.
Customer’s Model:
Customer’s
Approval Requested.
Please return this copy as a certification of your approval.
Checked by:
Approved by:
Date:
Date:
APPROVE
REVIEW
POLT
杨过
刘三军
曹 盖
WENZHOU GANGYUAN ELECTRONICS CO.,LTD.
GANGYUAN
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
KAN0631K
PRODUCT
TACT SWITCH
REVISION
A
A.Specification
& meanings
The name of the tact switch is composed by type and specification, particular meaning of the type、
the
specification
and code is as follows.
KAN0631K-
Press force(refer to chart 3)
Stem color(refer to chart 2)
Product height(refer to chart 1)
1、
Product height: It is denoted by three figures; For examples,“050”expresses the product which the total
height is 5mm,as chart 1 shows:
Code
050
060
070
073
080
090
Product height
5
6
7
7.3(方头)
8
9
Code
095
100
110
115
120
125
130
Product height
9.5
10
11
11.5
12
12.5
13
Code
153
170
180
Product height
15.3
17
18
2、Stem
color: It is expressed by a figure, as chart 2 shows:
Color
Code
Black
1
Red
2
Gray
7
Light gray
8
3、Operating
force: An English letter expresses it, unite: Newton (N),as chart 3 shows:
Operating
force
Code
A
B
C
Press force
Spec
1.0
1.6
2.6
1.0±0.3
1.6±0.5
2.6±0.5
0.2min
0.4min
0.6min
Return force
Examples: “KAN0631K-0501B” denotes the tact switch with 6×6 base, the height is 5mm,the stem is black , the
operating force is 1.6N.
APPROVE BY
杨 过
11.04.07
CHECKED BY
刘三军
11.04.07
PRPARE BY
曹 盖
11.04.07
Page 1 of 11
GANGYUAN
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
PRODUCT
TACT SWITCH
REVISION
A
KAN0631K
1、
概述
GENERAL
1.2
适用范围
APPLICATION
此规格书适用于机械式½触开关的相关要求
This specification is applied to the requirements for TACTILE SWITCH (MECHANICAL CONTACT)
1.3
工½温度范围
Operating Temperature Range
-20℃½70
℃
(
在标准大气压、标准湿度条件下)
-20℃½70℃(Normal humidity, normal air pressure)
1.4
贮藏温度范围
Storage Temperature Range
-30℃½80
℃
(
在标准大气压、标准湿度条件下)
-30℃½80℃(Normal humidity, normal air pressure)
1.5
测试条件
Test Conditions
在没有其它特定的条件下,应该在以下的条件下进行测试和测量:
Unless otherwise specified, tests and measurement shall be made in the following standard conditions:
常温…………………………………5℃½35℃
Normal temperature………………5℃½35℃
标准湿度……………………………相对湿度
25%½85%
Normal humidity…………………relative humidity 25%½85%
标准大气压…………………………86KPa½106Kpa
Normal air pressure…………………86Kpa½106Kpa
在制造过程中,测试和测量应该在以下的条件下进行:
If any doubt arise from the judgment, tests shall be conducted at the following conditions:
温度…………………………………20
℃
±2
℃
Temperature………………………20
℃
±2
℃
相对湿度……………………………65%±5%
Relative humidity………………65%±5%
环境气压…………………………86KPa½106Kpa
Air pressure…………………………86KPa½106Kpa
APPROVE BY
杨 过
11.04.07
CHECKED BY
刘三军
11.04.07
PRPARE BY
曹 盖
11.04.07
Page 2 of 11
GANGYUAN
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
KAN0631K
PRODUCT
TACT SWITCH
REVISION
A
2、
2.1
2.2
2.3
2.4
详细说明
Detailed specification
外观:应无½响、降½产品性½的缺陷;
Appearance: There should be no defects that affect the serviceability of product.
结构尺寸和安装尺寸:应符合装配图要求;
Style and dimension: shall conform to the assemble drawings.
操½½式:有触觉反应的操½
Type of actuating: Tactile feedback.
开关结构:单回路单输出(具½的触点结构在装配图中已绘出);
Contact arrangement: 1 pole, 1 throw
(Details of contact arrangement are given in the assembly drawings.)
2.5 开关工½额定值:DC 12V,50mA(有效值)
Ratings: 12V DC, 50mA (effective value)
3.电气性½:
ELECTRICAL SPECIFICATION
项
目
试 验 条 件
TEST CONDITIONS
在以 5V 10mA 的直流电源或不½于 1KHz 的交流电源
的电路中,以一个等于 2 倍按力的静负荷½加于手柄中心
1
接触电阻
Contact Resistance
Applying a static load of 2 times operating force to
the center of the stem, measurements shall be made by
5V DC 10mA or more than 1KHZ AC small-current
contact resistance meter.
在端子之间½加 DC 100V /1min 的条件下,测量端子
之间底座、盖板的电阻值
Measurement shall be made following application of
100V DC potential, across terminals, and across
terminals and cover, for one minute.
无击穿、无飞弧
There should be
no breakdown and
flashover
PRPARE BY
曹 盖
11.04.07
Page 3 of 11
≥100MΩ
≤100mΩ
要求
REQUIREMENTS
ITEM
绝缘电阻
2
Insulation
Resistance
介质耐压
3
Dielectric
voltage proof
APPROVE BY
杨 过
11.04.07
在端子之间½加 250V AC(50HZ 或 60HZ)/1min
250V AC (50HZ or 60HZ) shall be applied across
terminals, for one minute.
CHECKED BY
刘三军
11.04.07
GANGYUAN
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
KAN0631K
PRODUCT
TACT SWITCH
REVISION
A
要求
REQUIREMENTS
项目
ITEM
4.机械性½:
MECHANICAL SPECIFICATION
试 验 条 件
TEST CONDITIONS
1
按力
Operating
Force
开关垂直于操½方向放½,在开关驱动件顶端中心逐渐½力,测
量开关导通所需的最大力度。
Placing the switch such that the direction of switch operation is
vertical and then gradually increasing the load applied to the
center of the stem, the maximum load required for the switch to
come to a stop shall be measured.
refer to chart 3
2
最大行程
Full Travel
开关垂直于操½方向放½,以一个等于
2
倍按力的静负荷½加在
开关驱动件顶端中心,测量顶端移动的距离。
Placing the switch such that the direction of switch operation is
vertical and then applying static load of 2times operating force to
the center of the stem; the travel distance for the switch to come
to a stop shall be measured.
0.25±0.1mm
APPROVE BY
杨 过
11.04.07
CHECKED BY
刘三军
11.04.07
PRPARE BY
曹 盖
11.04.07
Page 4 of 11