BSY2-IOV2-M
BYD Microelectronics Co., Ltd.
Current Sensors
Description
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic
isolation between the primary circuit and the secondary circuit.
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Compact design for PCB mounting
Low power consumption
Extended measuring range (3 *I
PN
)
Insulated plastic case recognized
according to UL 94-V0
I
PN
=
50…600A
V
OUT
= ± 4 V
Advantages
Easy installation
Excellent accuracy
No insertion losses
Excellent performance and price
Only one design for wide current
ratings range
High immunity against external
Interference
Industrial applications
AC variable speed drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Power supplies for welding applications
Static converters for DC motor drives
Switched-Mode Power Supplies (SMPS)
TYPES OF PRODUCTS
Type
BSY2 – 50/4IOV2
BSY2 -75/4IOV2
BSY2-100/4IOV2
BSY2-150/4IOV2
BSY2-200/4IOV2
BSY2-300/4IOV2
BSY2-400/4IOV2
BSY2-500/4IOV2
BSY2-600/4IOV2
Primary nominal current
r. m. s I
PN
(A)
50
75
100
150
200
300
400
500
600
Primary current measuring
range I
PM
(A)
±150
±225
±300
±450
±600
±900
±900
±900
±900
Datasheet
ES-BYD-WDZCE11D-001
Rev. A/0
Page 1 of 4
BYD Microelectronics Co., Ltd.
BSY2-IOV2-M
Current Sensors
Parameters Table
PARAMETERS
SYMBOL
UNIT
VALUE
CONDITIONS
Electrical data
Supply voltage(±5%)
(1)
Current consumption
Output voltage(Analog)
Overload capability(1ms)
Isolation resistance
Output internal resistance
Load resistance
(2)
R. m. s voltage for AC isolation test
R. m. s rated voltage、safe separation
V
C
I
C
V
OUT
I
PC
R
IS
R
OUT
R
L
V
d
V
b
V
mA
mV
At
MΩ
Ω
KΩ
KV
V
±15
±15
±4V±40
50* I
PN
>1000
100
>1
3
500
@50Hz, 1 min
@ 500 VDC
approx
@ ± I
PN
, R
L
= 10 kΩ, T
A
= 25°C
Accuracy - Dynamic performance data
Linearity
(3)
(0…±I
PN
)
Accuracy
Electrical offset voltage
Hysteresis offset voltage
Temperature coefficient of VOE
Temperature coefficient of V
OUT
Response time
d
i
/d
t
accurately followed
Frequency bandwidth
(4)
ε
L
X
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
d
i
/d
t
BW
%of I
PN
%
mV
mV
mV/K
%/K
µS
A/µS
kHz
<±1
<±1
<±20
<±20
<±2
<±1
<±0.1
<3
>50
DC~50
@-3dB
@ I
PN
, T
A
= 25°C
(without offset)
@T
A
= 25°C
@ I
P
= 0;
after an excursion of 1* I
PN
@BSY2 50--75IOV2-M
@BSY2 100--600IOV2-M
@% of reading
@ 90% of I
PN
step
General data
Ambient operating temperature
Ambient storage temperature
Mass
T
A
T
S
m
℃
℃
g
-40….+85
-40….+105
approx 60
Notes:
(1)Operating
at ±12V
≤V
C
<±15V will reduce the measuring range.
(2)If
the customer uses 1 KΩ of the load resistor, the primary current has to be limited as
the nominal. To measure the full defined measuring range, the load resistor should be at
minimum 10 KΩ
(3)Linearity
data exclude the electrical offset.
(4)Please
refer to derating curves in the technical file to avoid excessive core heating at
high frequency.
Datasheet
ES-BYD-WDZCE11D-001
Rev. A/0
Page 2 of 4
BYD Microelectronics Co., Ltd.
BSY2-IOV2-M
Current Sensors
Dimensions BSY2-IOV2-M
(in mm. 1 mm = 0.0394 inch)
◆Instructions
of use
1. When the test current passes through the sensors you can get the size of the output voltage.
(Warning: wrong connection may lead to sensors damage)
2. Based on user needs, the sensors output range can be appropriately regulated.
3. According to user needs, different rated input currents and output voltages of the sensors can
be customized.
Datasheet
ES-BYD-WDZCE11D-001
Rev. A/0
Page 3 of 4
BYD Microelectronics Co., Ltd.
BSY2-IOV2-M
Current Sensors
RESTRICTIONS ON PRODUCT USE
The information contained herein is subject to change without notice.
BYD Microelectronics Co., Ltd. (short for BME) exerts the greatest possible effort to ensure high quality and
reliability. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent
electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing
BME products, to comply with the standards of safety in making a safe design for the entire system,
including redundancy, fire-prevention measures, and malfunction prevention, to prevent any accidents, fires,
or community damage that may ensue. In developing your designs, please ensure that BME products are used
within specified operating ranges as set forth in the most recent BME products specifications.
The BME products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic
appliances, etc.). These BME products are neither intended nor warranted for usage in equipment that
requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of
human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control
instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments,
combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of
BME products listed in this document shall be made at the customer’s own risk.
Datasheet
ES-BYD-WDZCE11D-001
Rev. A/0
Page 4 of 4