ISO9001: 2000
ISO14001: 2004
APPROVAL SPECIFICATIONS
Title.
Product Model.
Customer’s Part NO.
Customer’s Model:
TACT SWITCH
TS-1087SM
Customer’s Approval Requested.
Please return this copy as a certification of yourapproval.
Checked by:
Approved by:
Date:
Date:
APPROVE
REVIEW
POLT
王凱
李成功
許志明
XUNPU ELECTRONICS CO.,LTD
XUNPU
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
PRODUCT
REVISION
TS-1087SM
TACT SWITCH
产品符合ROHS
General tolerance:±0.2mm
NO.
1
2
3
4
NAME
Terminal
Contact
Base
Dust Caver
MATERIAL
Phosphor Bronze
F.Ag/SUS
NATIONALITY
QTY.
4
1
1
1
FINISHING
Plating silver
Natural
Black
Yellow
Nylon
Kapton Film
APPROVE BY
王凱
12.05.21
CHECKED BY
李成功
12.05.21
PRPARE BY
許志明
12.05.21
Page 1of 10
XUNPU
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
PRODUCT
REVISION
A.Specification
& meanings
The name of the tact switch is composed by type and specification,the particular meaning of the type、specification
and code is as follows.
TS-1087SM
-
TS-1087SM
TACT SWITCH
Operating force
(
refer to chart1
)
1
、Ope
rating force: An English letter expresses it, uni te: Newton (N),as chart 1 shows:
Operating
force
Code
16
26
Spec
Press force(N)
Return force
1.6
2.6
1.6±0.5
2.6±0.5
0.4min
0.4min
Examples: “TS-1087SM-16” dhe pressure of this type of touch switch is 1.6N.
APPROVE BY
王凱
12.05.21
CHECKED BY
李成功
12.05.21
PRPARE BY
許志明
12.05.21
Page 2 of 10
XUNPU
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
PRODUCT
TACT SWITCH
REVISION
TS-1087SM
1、
概述
GENERAL
1.2
适用范围
APPLICATION
此规格书适用于机械式½触开关的相关要求
This specification is applied to the requirements for TACTILE SWITCH (MECHANICAL CONTACT)
1.3
工½温度范围
Operating Temperature Range
-20℃½70℃(在标准大气压、标准湿度条件下)
-20℃½70℃(Normal humidity, normal air pressure)
1.4
贮藏温度范围
Storage Temperature Range
-30℃½80℃(在标准大气压、标准湿度条件下)
-30℃½80℃(Normal humidity, normal air pressure)
1.5
测试条件
Test Conditions
在没有其它特定的条件下,应该在以下的条件下进行测试和测量:
Unless otherwise specified, tests and measurement shall be made in the following standard conditions:
常温…………………………………5℃½35℃
Normal temperature………………5℃½35℃
标准湿度………
………… …………相对湿度 25%½85%
Normal humidity…………………relative humidity 25%½85%
标准大气压………
…………………86KPa½106Kpa
Normal air pressure…………………86Kpa½106Kpa
在制造过程中,测试和测量应该在以下的条件下进行:
If any doubt arise from the judgment, tests shall be conducted at the following conditions:
温度…………………………………20℃±2℃
Temperature………………………20℃±2℃
相对湿度………
………… …………65%±5%
Relative humidity………………65%±5%
环境气压…………………………86KPa½106Kpa
Airpressure…………………………86KPa½106Kpa
APPROVE BY
王凱
12.05.21
CHECKED BY
李成功
12.05.21
PRPARE BY
許志明
12.05.21
Page 3 of 10
XUNPU
CUSTOMER
CUSTOMER’S P/N
APPROVAL SPECIFICATIONS
GYE’S P/N
PRODUCT
REVISION
TS-1087SM
2、
详细说明
Detailed specification
2.1 外观:应无½响、降½产品性½的缺陷;
Appearance: There should be no defects that affect the serviceability of product.
2.2 结构尺寸和安装尺寸:应符合装配图要求;
Style and dimension: shall conform to the assemble drawings.
2.3 操½½式:有触觉反应的操½
Type of actuating: Tactile feedback.
2.4 开关结构:单回路单输出(具½的触点结构在装配图中已绘出);
Contact arrangement: 1 pole, 1 throw
(Details of contact arrangement are given in the assembly drawings.)
2.5 开关工½额定值:DC 12V,50mA(有效值)
Ratings: 12V DC, 50mA (effective value)
3.电气性½:
ELECTRICAL SPECIFICATION
项
目
试 验 条 件
TEST CONDITIONS
在以 5V 10mA 的直流电源或不½于1KHz 的交流电源
的电路中,以一个等于2倍按力的静负荷½加于手柄中心
1
接触电阻
Contact Resistance
Applying a static load of 2 times operating force to
the center of the stem, measurements shall be made by
5V DC 10mA or more than 1KHZ AC small-current
contact resistance meter.
绝缘电阻
2
Insulation
Resistance
介质耐压
3
Dielectricvolt
age proof
APPROVE BY
王凱
12.05.21
在端子之间½加 DC 100V /1min 的条件下,测量端
子之间底座、盖板的电阻值
Measurement shall be made following application of
100V DC potential, across terminals, and across
terminals and cover, for one minute.
在端子之间½加
250V AC(50HZ
或
60HZ)/1min
250V AC (50HZ or 60HZ) shall be applied across
terminals, for one minute.
CHECKED BY
李成功
12.05.21
PRPARE BY
无击穿、无飞弧
There should be
no breakdown and
flashover
許志明
12.05.21
≥100MΩ
≤100mΩ
要求
REQUIREMENTS
ITEM
Page 4 of 10