温控器系列
KSD301
试验报告
Test report of thermostat KSD301 series
客户名称
Customer
产品型号
Product model
温度规格
Temperature
specification
动½温度
Switching temperature
W.HQ
KSD301
生产日期
Date:
样品数量
Sample
quantity:
2018-01-25
5pcs
壳½材料
70/103PAK/18IB/RTG-WHQ
Shell material:
√塑料
PF
□陶瓷
Ceramic
□高温塑料
PPS
70+/-3℃
端子:
Tab
□4.8mm √6.3mm√180o
□90
o
□20o □45
o
□
大铝盖
Big Aluminum cap with fixed bracket
√
小铝盖带活动环
Small aluminum cap with moveable
bracket
□
小铝盖不带活动环
Small aluminum cap without movable
bracket
复½温度
Reset temperature
55+/-5℃
特殊要求
Special
request:
技术说明
Technology of specification
接触电阻
Resistance of contact
绝缘电阻
Resistance of Insulated
耐压
Test voltage
CQC、TUV
参数
VDE、UL
参数
EnduranceCycles tested
EnduranceCycles tested
≤50
mΩ
Dc 500V >100 MΩ
>AC 1500V/1Min
AC250V 10A
AC250V 10A
100,000 cycles
100,000 cycles
测试数据
Test data
动½温度 (℃)
NO.
1
2
3
4
5
switching
temperature
复½温度 (℃)
Reset temperature
接触电阻 (mΩ)
Resistance of
contact
耐 压
Test voltage
结论
conclusion
72-78
72-78
72-78
72-78
72-78
50-60
50-60
50-60
50-60
50-60
合格(OK)
合格(OK)
合格(OK)
合格(OK)
合格(OK)
合格
(OK)
测试设备
Testing Device:
恒温测温桶:Thermostatic
temperature measurement barrel;
温度异常时以我方测温为准:
It is subject to our test temperature when the temperature
anomalies
拟制(Prepared
by):
刘春青
审核
(Checked by):
½俊刚
审批(Approved
by):吴斌怀
φ16+/-0.2
技术要求(Technology
Specification)
11.8+/-0.5
A
33.6+/-1
KSD301
3
A
向
1、电气性½(Electric Performance):
额定电压/电流(Rated
Voltage/Current):250V10A
IP-防护等级(Protection Degree): IP00级
寿½(Operation
Cycles):CQC、TUV 10000
VDE、UL 100000
接触电阻(Resistance
of Contact):
≤50mΩ
绝缘电阻(Resistance
of Insulated):≥100MΩ
耐压(Test
Voltage):≥1500V/1min (Normality)
2、适用标准(Relevant Standards)
UL873,CSA C22.2 NO 24-93
EN 60730-1 2012-10
EN 60730-2-9:2011-07
GB14536.1-2008 idt IEC 60730-1-2008
GB14536.10-2008 idt IEC 60730-2-9-2010
3、证书号码(Certificate No):
0.4
3.6
0.8
K070
PM
φ
1.8
6.3
□
CQC: CQC04002009128
√
TUV: 50035898
□
VDE: 40020934
√
U L: E251340
24+/-0.5
32+/-1
(Phenolic)
4、客户代码
:W.HQ
编码/Part.NO
复½状态/Auto/Manual
reset
动½温度/Open
temperature
同
复½温度/Close
temperature
活动支架/Bracket
端子尺寸/Terminal
size
设计/Designed
by
自动复½
70+/-3℃
55+/-5℃
6.3*0.8平脚
型号/Model
KSD301
名称/Name
Thermostat/温控器
图号/Code
XC-WK.CP/K3.01-
XXXX
小铝盖带活动环
材质/Material
承认/
SIGNATURE
核准/
APPROVED BY
客户签章/
CUSTOMER
电木
页次/Total
审核/Checked
by
批准/Approved
by
日期/Date
1/1
版本/Edition
A/1
刘春青
2018-01-25
旭程电子(深圳)有限公司温控器事业部
XC ELECTRONICS (SHENZHEN)CO.,LTD.
技术规格
Technology Specification
1.型号½名 (Type Designation)
KSD.301- XXX / XX X X X X
触点 接 触状 态:
B常闭
、
K常
开
Contact status:Nomally Closed
、
Nomally Open
A/C. 6.3x0.8
端子
flat push-on connectors
B/D .4.8x0.8
端 子
flat push-on connectors
B/C.
陶瓷 壳 ½
ceramic material
P.
塑 料电 木 壳½
PF
(
plastic
)
material
S.
高 温塑 料 壳½
high-temp material
铝 盖 及安 装 固定 环
Shell and fixed bracket
电 流
(Rated Current)
250
V
(1-10
A
)/125
V
(1-15
A
)
动 ½ 温度
Switching Temperature
产 品 设计 型 号
Type Code
0
½
150
℃
塑 料电 木 壳½
(0
½
150
℃
for KSD301XPZ)
0
½
210
℃
陶 瓷壳 ½
(0
½
210
℃
for KSD301XCZ)
0
½
180
℃
高 温塑 料 壳½
﹝0
½
180
℃
forKSD301XSZ
﹞
2.适用标准(Relevant Standards)
UL873, CSA C22.2 NO 24-93
EN60730-1 2000+A11
EN60730-2-9:2002
GB14536.1-2008 idt IEC730-1
GB14536.10-2008 idt IEC730-2-9-1992
3.电气性½(Electric Performance):
额定电压(Rated
Voltage): AC125V 50~60Hz
额定电流(Rated
Current):1-10A/1-15A of Resistive Load
开关类型和单极断开(Switch
Type and Number of poles): 1 pole opener
IP-防护等级(Protection Degree): IP00
动½类型(Action
Type)
:2C
认证(Approved
Symbol):CQC、T¨ V、 VDE、 UL
寿½(Operation
Cycles): CQC、T¨ V 10,000
VDE、 UL 100,000
所用绝缘材料
PTI
值(Insulation
material PTI value):175V
接触电阻(Resistance
of Contact)
≤50mΩ(Original State)
:
绝缘电阻(Resistance
of Insulated)
:≥100MΩ(DC500V
Normality)
耐压(
Test Voltage ): ≥
1250V/1min(Normality)
4.端子应½承受的½向力(Axis force that tab can endure)
½用于端子的½向力
1min(如下表)不应有½移和损坏。
Axis force that Tab can endure for 1min, and no deformation and damage.
推力
thrust force(N)
80
拉力
pull force(N)
70
扭力
torque (N.m)
0.2
5.标志 (Marking)
在温控器壳½上应标注商标
,
额定电压
250V/125V(必要时)电流性质交流½,认
证标志(必要时)
,型号标志
KSD301,动½温度标示应清晰、持久、耐用,应印在主
½及不可拆部½上。
On the thermostat, our trade mark
; voltage rating 250V/125V AC(necessary);
approved symbol
(necessary).And
item No.KSD301 should be carved. Switching
temperature should be on the main part of the thermostat or on the part that cannot be torn
up. The mark should be clear and durable.
6.环境试验(Ambient test)
6.1
环境应力(Ambient
resistance stress)
温控器在-10℃+/-2
℃
24h,+60
℃+/-5℃
4h,
塑料件不应开裂、
变½,温控器仍½正常工
½。
Under the situation of -10℃+/-2
℃
24h,+60
℃+/-5℃
4h, the plastic parts should be no
breaking and deformation, and the thermostat can work normally.
6.2
½湿试验(Humidity
resistance test)
温控器在相对湿度
91½95%温度在 20½30(¡ 1℃)½湿箱内处理 48h
应½承受
AC 1250V,频率 50Hz-60Hz 1min
不应产生闪络或击穿.
In the humid box of relative humidity 91-95%, temperature 20½30(¡ 1℃) for 48 hours,
the thermostat should endure voltage of 1250V AC. When the frequency is 50Hz-60Hz
1min, flashover and bumping is not allowed.
7.
温控器的发热(Heat
resistance test)
温控器在比工½温度½
5
℃
¡ 1
℃环境条件下,通
10.6A
电流,它的端子温度不大于
230
℃
.
The contact temperature of thermostat is not higher than 230
℃
in the circuit of 10.6A, at
the temperature of less than 5
℃
¡ 1
℃
of working temperature.
8.动½方式(Action Forms)
室温下触点接通(nc)
,温度上升触点断开,温度降½触恢复接通。
Normal close:Cut out at temperature rise,cut in at temperature decreasing.
室温下触点接通(nc)
,温度下降触点断开,温度上升触恢复接通。
Normal close:Cut out at temperature decreasing.,cut in at temperature rise.
室温下触点断开(no)
,温度上升触点接通,温度降½触恢复断开。
Nornal opon:Cut in at temperature rise, cut out at temperature decreasing.
室温下触点断开(no)
,温度下降触点接通,温度上升触恢复断开。
Nornal opon:Cut in at temperature decreasing, cut out at temperature rise.
室温下触点接通(nc)
,温度上升触点断开,温度降½手动复½接通。
Normal close:Cut out at temperature rise,manual reset at temperature decreasing.
9.手动复½产品
温控器手动复½产品所受复½力为:14-20N.