SLD-Axial Leaded Strap Lead(Pb) Free PTC Devices
SLD-Axial Leaded Strap Lead(Pb) Free PTC Devices
Description
The new SLD Axial Leaded Strap Lead(Pb) Free PTC device are designed
based on a proprietary conductive polymer material, to provide both
overcurrent and overtemperature protection for rechargeable battery cells.
The SLD Axial Leaded Strap Lead(Pb) Free devices featuring a slim, low
profile and low resistance design and are ideal to install directly on the latest
generations of battery cells for longer battery run time.
SLD products provide reliable, noncycling protection against overcharging
and short circuits events and increase the battery safety level.
Agency Approval and Environmental Compliance
Agency
File Number
E201431
R50103314
Regulation
Standard
2011/65/EU
IEC 61249-2-21:2003
Electrical Characteristics
I
hold
(A)
1.40
1.90
1.90
1.90
1.90
1.90
1.90
2.70
2.70
2.70
3.10
3.70
3.70
3.70
Part Number
SLD140GF
SLD190GF
SLD190LF
SLD190MF
SLD190RLF
SLD190VF2
SLD190VF4
SLD270GF-22
SLD270UF
SLD270UF2
SLD310GF-12
SLD370GF-C
SLD370GF-D
SLD370GUF-AC
I
trip
(A)
3.60
4.90
4.90
4.90
4.90
4.90
4.90
6.20
6.20
6.20
8.00
9.00
9.00
9.00
V
max
(Vdc)
6
6
6
6
6
6
6
6
10
6
6
6
6
6
I
max
(A)
50
50
50
50
50
50
50
50
50
50
50
50
50
50
P
d typ
(W)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.2
Maximum
Time To Trip
Current Time
(A)
(Sec.)
7.0
9.5
9.5
9.5
9.5
9.5
9.5
13.5
13.5
13.5
15.5
18.5
18.5
18.5
3.00
3.00
3.00
3.00
3.00
3.00
3.00
2.00
2.00
2.00
3.00
5.00
5.00
5.00
Resistance
R
min
(Ω)
0.010
0.006
0.006
0.007
0.006
0.008
0.008
0.006
0.006
0.006
0.005
0.005
0.005
0.005
Agency
Approval
R
max
R
1max
(Ω)
(Ω)
0.020
0.013
0.013
0.015
0.014
0.014
0.014
0.014
0.014
0.014
0.013
0.013
0.013
0.013
0.035
0.024
0.024
0.024
0.024
0.024
0.024
0.026
0.026
0.026
0.024
0.020
0.020
0.020
新竹市科學工業園區工業東四路
24-1
號
No. 24-1 Industry E. Rd. IV, Hsinchu Science Park, Hsinchu 300, Taiwan.
TEL: +886-3-5643931 FAX: +886-3-5644624
http://www.pttc.com.tw
Page: 2 of 7
2017/03/23 Revision: F
SLD-Axial Leaded Strap Lead(Pb) Free PTC Devices
How to Select a Polymer PTC fuse
(1) Determine the following operating parameters for the circuits:
(A) Normal Operating Current (I hold)
(B) Maximum Circuit Voltage (V max)
I Maximum Interrupt Current (I max)
(D) Normal Operating Temperature (min ºC /max ºC)
(2) Select the device form factor and dimension suitable for the application:
Axial Leaded Strap Device (SLD, VTD, LTD, LRD , STD ,LTD Series)
Surface Mount Device (SMD Series)
Radial Leaded Device (RLD Series)
Other Custom-designed Device (Disc/Chip)
(3) Compare the maximum ratings for V max and I max of the PTC device with the circuit in
application and make sure that the circuit’s requirement does not exceed the device ratings.
(4) Check that the PTC device’s trip time (time-to-trip) will protect the circuit.
(5) Verify that the circuit operating temperatures are within the PTC device’s normal operating temperature range.
(6) Verify the performance and suitability of the chosen PTC device in the application.
新竹市科學工業園區工業東四路
24-1
號
No. 24-1 Industry E. Rd. IV, Hsinchu Science Park, Hsinchu 300, Taiwan.
TEL: +886-3-5643931 FAX: +886-3-5644624
http://www.pttc.com.tw
Page: 3 of 7
2017/03/23 Revision: F
SLD-Axial Leaded Strap Lead(Pb) Free PTC Devices
THERMAL DERATING CURVE FOR SLD SERIES
200.00
Pe r c e n t a g e o f r a t e d c u r r e n t ( %)
160.00
120.00
80.00
40.00
-40.00
0.00
40.00
80.00
Device ambient temperature(degC)
THERMAL DERATING CHART FOR SLD SERIES – Ihold (Amps)
Model
SLD140GF
SLD190GF
SLD190LF
SLD190MF
SLD190RLF
SLD190VF2
SLD190VF4
SLD270GF-22
SLD270UF
SLD270UF2
SLD310GF-12
SLD370GF-C
SLD370GF-D
SLD370GUF-AC
Ambient Operation Temperature
-40 ºC
2.2
3.5
3.5
3.5
3.5
3.5
3.5
5.4
5.4
5.4
5.0
6.5
6.5
6.5
-20 ºC
2.0
3.0
3.0
3.0
3.0
3.0
3.0
4.6
4.6
4.6
4.4
5.6
5.6
5.6
0 ºC
1.7
2.6
2.6
2.6
2.6
2.6
2.6
3.8
3.8
3.8
3.8
4.8
4.8
4.8
25 ºC
1.4
1.9
1.9
1.9
1.9
1.9
1.9
2.7
2.7
2.7
3.1
3.7
3.7
3.7
40 ºC
1.2
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.6
3.0
3.0
3.1
50 ºC
1.1
1.4
1.4
1.4
1.4
1.4
1.4
1.8
1.8
1.8
2.3
2.6
2.6
2..6
60 ºC
1.0
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
2.0
2.2
2.2
2.2
70 ºC
0.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.7
1.7
1.7
80 ºC
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.6
0.6
0.6
1.1
1.3
1.3
1.3
新竹市科學工業園區工業東四路
24-1
號
No. 24-1 Industry E. Rd. IV, Hsinchu Science Park, Hsinchu 300, Taiwan.
TEL: +886-3-5643931 FAX: +886-3-5644624
http://www.pttc.com.tw
Page: 4 of 7
2017/03/23 Revision: F
SLD-Axial Leaded Strap Lead(Pb) Free PTC Devices
AVERAGE TIME-CURRENT CURVE FOR SLD SERIES
100.00
A= SLD140
B= SLD190
C= SLD270
B
C
DE
10.00
A
D= SLD310
E= SLD370
Time to Trip (sec)
1.00
0.10
0.01
0.00
1.00
10.00
100.00
Fault Current (Amp.)
PART NUMBERING SYSTEM
SLD
□□□ □□
G: General Type
R: Rectangular lead
V: Vertical Lead
M: Small Chip
F: Lead Free
Hold Current Rating
Axial Leaded Strap Device
新竹市科學工業園區工業東四路
24-1
號
No. 24-1 Industry E. Rd. IV, Hsinchu Science Park, Hsinchu 300, Taiwan.
TEL: +886-3-5643931 FAX: +886-3-5644624
http://www.pttc.com.tw
Page: 5 of 7
2017/03/23 Revision: F