电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

NPS62-M

器件型号:NPS62-M
厂商名称:Vertiv
下载文档 在线购买

NPS62-M在线购买

供应商 器件名称 价格 最低购买 库存  
NPS62-M - 1 点击查看 点击购买

器件描述

60 Watts

NPS62-M器件文档内容

                                                                                                       Embedded Power for
                                                                                                       Business-Critical Continuity

NPS60-M Series                                                                                         Rev.03.21.13_185
                                                                                                         NPS60-M Series
60 Watts                                                                                                                1 of 3

Total Power:    60 Watts
Input Voltage:  90 - 264 VAC
                127 - 300 VDC
# of Outputs:   Single

Special Features                     Electrical Specifications

Medical and ITE Safety Approvals   Input
Universal input
Less than 1U high                  Input range:           90 - 264 VAC (wide range) 127-300 Vdc
2" x 4" footprint
Remote sense                       Frequency:             47 - 63 Hz
Overload and short circuit
                                     Inrush current:        < 50 A peak @ 230 VAC, cold start @ 25 C
   protection
Adjustable output voltage          Input power:           < 74 Watts
High efficiency
High MTBF                          Efficiency:            87% average (as per Energy Star 2.0 standard) (NPS62-M, 80%)
Built in EMI filter                EMI/RFI:
                                                            FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B con-
   (CISPR 22 Class B)                Safety ground leakage  ducted, VDE0878PT3 Class B conducted
International Efficiency Level V,  current:               275uA @ 50/60 Hz; 264 VAC input

   Energy Star 2.0 & CeC compliant   Output
   (except NPS62-M)
Less than 300 mW no-load           Maximum power:         60 W for convection
   power consumption
0C to +80C operation             Adjustment range:       20% minimum
Input power < 74 watts
Complies with EN61000 -3-2         Hold-up time:          10/20 ms 115/230 VAC input line
UL Class I approved                Overload protection:
Class II approved (with Class A                           Short circuit protection on all outputs. Case overload protected @
   EMI)                                                     110-180% of normal rating
LPX50 enclosure kit available
Dual AC fuses                      Overvoltage protection: 30-50% above nominal output

Safety                               Remote sense:          Compensated for 0.5 V lead drop max. Will operate without remote sense

TUV:     60950, 60601-1                                   connected. Reverse connection protected.
UL:     60950, 60601-1
CSA:     60950, 60601-1
NEMKO: 60950, 60601-1
CB: Certificate and report
CE:     Mark (LVD)
CCC:     Mark
                                                                                                        Embedded Power for
                                                                                                        Business-Critical Continuity

Environmental Specifications                                                                                             Rev.03.21.13_185
                                                                                                                           NPS60-M Series
                                                                                                                                          2 of 3

Operating temperature:  0 to 50 C ambient derate each output at 2.5% per degree from 50 to 80 C. -20 C start up

Storage temperature:    -45 C to +85 C

Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3

Humidity:               Operating; non-condensing 10% to 90% RH

Vibration:              IEC68-2-6 to the levels of IEC721-3-2

MTBF demonstrated:      > 550,000 hours at full load and 25 C ambient conditions

Mechanical Drawing

                         BARCODE                                    4.00"                               VR1              1.12"
                        SERIAL LABEL                               (101.6) 3.73"                 OUTPUT VOLTAGE          (28.5)

                            M1                                               (94.6)                 ADJUST POT

                            GND TAB                                                              PIN 1  1.72"
                              (CN1)                                                                SK2     (43.8)

                                PIN 1                                                            PIN 6        2.00"
                                                                                                                 (50.8)
                                 SK1
                                           MODEL LABEL                               M2                 6 PIN OUTPUT
                                PIN 3                  ROHS LABEL
                                    INPUT                                                               CONNECTOR

                                CONNECTOR                                                                   (SK2)
                                    (SK1)

            0.16" (4.0) MOUNTING HOLE
                      (4 PLACES)

                                                                                                 1.26"
                                                                                                    (32.1)

                    0.197" (5.0) MINIMUM STANDOFF HEIGHT
                                                                                                                                    Embedded Power for
                                                                                                                                    Business-Critical Continuity

                                                                                                                                                        Rev.03.21.13_185

Ordering Information                                                                                                                                    NPS60-M Series

                                                                                                                                    Americas                                     3 of 3

Model     Output           Minimum Maximum Load with                Peak      Regulation2  Ripple P/P                              5810 Van Allen Way
Number     Voltage                                                   Load1                   (PARD)3
                                Load  Convection Cooling                                                                            Carlsbad, CA 92008

NPS62-M          5V             0A                  11 A             13 A       2%         50 mV                                   USA

                                                                                                                                    Telephone: +1 760 930 4600

NPS63-M    12 V                 0A                  5A               5.5 A      2%         120 mV                                  Facsimile: +1 760 930 0698

NPS64-M    15 V                 0A                  4A               4.4 A      2%         150 mV                                  Europe (UK)

NPS65-M    24 V                 0A               2.5 A               2.75 A    2%         240 mV                                  Waterfront Business Park
                                                                                                                                    Merry Hill, Dudley
1. Peak current lasting < 15 seconds with a maximum 10% duty cycle.                                                                 West Midlands, DY5 1LX
                                                                                                                                    United Kingdom
2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.              Telephone: +44 (0) 1384 842 211
                                                                                                                                    Facsimile: +44 (0) 1384 843 355
3. Peak-to-peak with 20 MHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and
   load ranges.                                                                                                                     Asia (HK)

Pin Assignments       NPS62-M         NPS63-M                        NPS64-M   NPS65-M                                              14/F, Lu Plaza
                                                                                                                                    2 Wing Yip Street
   Connector             Line            Line                           Line      Line                                              Kwun Tong, Kowloon
                       Neutral         Neutral                        Neutral   Neutral                                             Hong Kong
      SK1-1            Ground          Ground                         Ground    Ground                                              Telephone: +852 2176 3333
      SK1-3                             +12 V                          +15 V     +24 V                                              Facsimile: +852 2176 3888
       CN1               +5 V           +12 V                          +15 V     +24 V
      SK2-1              +5 V         Common                         Common    Common                                               For global contact, visit:
      SK2-2           Common          Common                         Common    Common
      SK2-3           Common           -Sense                         -Sense    -Sense                                              www.Emerson.com/EmbeddedPower
      SK2-4            -Sense          +Sense                         +Sense    +Sense
      SK2-5            +Sense                                                                                                       techsupport.embeddedpower
      SK2-6                                                                                                                         @emerson.com

                                                                                                                                    While every precaution has been taken to ensure
                                                                                                                                    accuracy and completeness in this literature, Emerson
                                                                                                                                    Network Power assumes no responsibility, and disclaims
                                                                                                                                    all liability for damages resulting from use of this
                                                                                                                                    information or for any errors or omissions.

Mating Connectors                                                                                                                   Emerson Network Power.
                                                                                                                                    The global leader in enabling
AC Input:  Molex 09-50-8031 (USA)                                                                                                   business-critical continuity.
           09-93-0300 (UK)
           PINS:  08-52-0113                                                                                                            AC Power
                                                                                                                                        Connectivity
DC Outputs: Molex 09-50-8061 (USA)                                                                                                      DC Power
                 09-93-0600 (UK)                                                                                                        Embedded Computing
                 PINS: 08-52-0113                                                                                                       Embedded Power
                                                                                                                                        Monitoring
Emerson Network Power Connector Kit #70-841-006, includes all of the above                                                              Outside Plant
                                                                                                                                        Power Switching & Controls
Notes:                                                                                                                                  Precision Cooling
1. Specifications subject to change without notice                                                                                      Racks & Integrated Cabinets

2. All dimensions in inches (mm), tolerance is 0.02" (0.5mm)                                                                          Services
                                                                                                                                        Surge Protection
3. Mounting holes M1 and M2 should be grounded for EMI purposes
                                                                                                                                    EmersonNetworkPower.com
4. Mounting hole M1 is safety ground connection
                                                                                                                                    Emerson and the Emerson Network Power
5. Specifications are for convection rating at factory settings at 115 VAC input, 25 C unless otherwise                            logo are trademarks of Emerson Electric Co.
   stated                                                                                                                           2012 Emerson Electric Co.
                                                                                                                                    All rights reserved.
6. For DC input an external DC safety rated fuse must be used

7. Warranty:  2 year

8. Weight: 0.26lbs/0.118kg
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Emerson Network Power:

  NPS64-M
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
搜索索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2021 EEWORLD.com.cn, Inc. All rights reserved