器件描述

Effi ciency to 95%

MSR7805-05WUP器件文档内容

MSR7805WUP Series

Low Cost, Non-isolated
UnPotted, Single Output
POL Switching Regulators

                               Electrical Specifications

                               Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.

Key Features:                  Input                                Conditions                 Min. Typ. Max.                     Units
                               Parameter                                                                                           mA
Efficiency to 95%            No-Load Input Current                Positive Ouput Connection                          0.2 1.5
0.5A Output Current          Input Filter
Miniature Construction       Reverse Polarity Input                           Capacitor Filter
EN 60950 Approved            Output
LM78xx Replacement                                                Not Allowed, Could Damage the Unit

Wide Input Range             Parameter                            Conditions                 Min. Typ. Max. Units

Negative Output Capability Output Voltage Accuracy                  3.3 VDC Output                                   2.0 4.0         %
Short Circuit Protected                                           All Other Outputs
                                                                                                                       2.0 3.0

Low Noise                    Line Regulation                      VIN = Min to Max                                   0.2 0.4         %

Low Low Cost                 Load Regulation                      IOUT = 10% to 100%                                 0.4 0.6         %

                               Ripple & Noise (20 MHz)                          See Note 2                             20 75 mV P - P

                               Temperature Coefficient                                                                 0.03       %/C

                               Transient Recovery Time, See Note 3  25% Load Step Change                               0.2 1.0           mS
                               Transient Response Deviation
                                                                                                                       50 250            mV

                               Output Short Circuit                           Continuous (Autorecovery)

                               General

                               Parameter                            Conditions                 Min. Typ. Max. Units

                               Isolation Voltage                                Not Isolated

                               Switching Frequency                                             550                     850               kHz

                               EMI Characteristics

                               Parameter                            Standard                   Criteria                           Level

                               Radiated Emissions, See Note 4                   EN 55022                 B

                               Conducted Emissions, See note 4                  EN 55022                 B

                               ESD                                  EN 61000-4-2                         B             6 kv Air, 4 kV Contact

                               RS                                   EN 61000-4-3                         A                        10V/m

                               EFT, See Note 5                      EN 61000-4-4                         B                        1 kV

                               Surge, See Note 5                    EN 61000-4-5                         B                        1 kV

                               CS                                             EN61000-4-6                A                      3V rms

                               Environmental

                               Parameter                            Conditions                 Min. Typ. Max. Units

                               Operating Temperature Range                      Ambient -40 +25 +85                                      C

MicroPower Direct              Storage Temperature Range                                                          -55  +125              C
                               Lead Temperature                     1.5 mm From Case For 10 Sec
292 Page Street                Cooling                                                                                 300               C
Suite D                        Humidity                                                         Free Air Convection
Stoughton, MA 02072            Physical                                         RH, Non-condensing                     95                %
USA

T: (781) 344-8226              Size                                                             See Mechanical Diagram (Page 4)
F: (781) 344-8481              Weight                                                                                    0.035 Oz (1.0g)
E: sales@micropowerdirect.com  Reliability Specifications
W: www.micropowerdirect.com    Parameter                                                       Min. Typ. Max. Units

                                                                    Conditions

                               MTBF                                 MIL HDBK 217F, 25C, Gnd Benign 2.0                           MHours

                               Safety Standards                                 EN 60950

                                                        www.micropowerdirect.com
Model Selection Guide                                                                                            www.micropowerdirect.com

         Model  Input Voltage (VDC)                          Output     Efficiency (%, Typ)                          Capacitive       Fuse
        Number                                                          Min VIN Max VIN                                  Load       Rating
MSR7805-033WUP  Nom.    Range                         Voltage Current                                                             Slow Blow
MSR7805-05WUP    24   4.75 - 36.0                                                                                      (F, Max)
                 24   6.50 - 36.0                     (VDC)  (mA, Max)                                                             (mA, Max
MSR7805-12WUP    12   7.00 - 31.0
                 24   15.0 - 36.0                     3.3    500.0                                           86  80  680          1,000
MSR7805-15WUP    12   8.00 - 24.0
                 24   19.0 - 36.0                     5.0    500.0                                           90  84  680          1,000
                 12   8.00 - 21.0
                                                      -5.0   -300.0                                          80  81  330

                                                      12.0   500.0                                           94  91  680          1,000

                                                      -12.0  -150.0                                          84  85  330

                                                      15.0   500.0                                           95  93  680          1,000

                                                      -15.0  -150.0                                          85  87  330

Notes:                                                                                                           Derating Curve
1. For many applications, no external components are required. If the input is over 30V, a 22 F/50V

     input capacitor (C1) is required. See the typical application note below.
2. Output ripple is measured with a nominal input and is specified for a load range of 10% to 100%.

     When measuring output ripple, two external capacitors (1 F and 10 F) must be placed from the VOUT to
     the Gnd pins.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
4. The unit may not meet emissions to class A without the addition of external capacitors (C1, C2 &
     C3) as shown in the typical circuit 4 diagram on page 4.
5. The unit meets EFT & surge EMS specifications with the addition of external components as
     shown in the typical circuit 4 diagram on page 4.
6. This regulator is not designed to be used in parallel with another unit to increase output power.
7. A reverse polarity connection on the input could damage the unit.
8. The input should not exceed the range given in the model selection chart. Exceeding this limit
     could damage the unit.

For many applications, the MSR7805-xxWUP can          Typical Application Circuit 1, Positive Output
be used without external components. However, if      Typical Application Circuit 2, Negative Output
the application requires meeting EMC/EMI stan-
dards or operation at inputs over 30V, a minimum
of external components is needed.

A typical connection (for a positive output voltage)
is shown at right. Here, C1 has been added to
improve stability over the input range (and over
the operating temperature range). Capacitor C2
is added to reduce the output ripple.

Suggested values for these capacitors are given
in the "Component Values" table below. These
capacitors are ceramic and should be placed as
close to the unit as possible. Tantalum or low ESR
electrolytic capacitors may also be used.

If very low noise is required, the LC filter may be
added (LOUT & COUT). The recommended value
for LOUT is 10 H - 47 H. For COUT, a 22 F. is
recommended. To meet EMI standards, see the
typical circuit 4 diagram on page 4.

Model          C1     C2
Number

MSR7805-033WUP 22 F/50V 22 F/6.3V

MSR7805-05WUP 22 F/50V 22 F/10V

MSR7805-12WUP 22 F/50V 22 F/25V

MSR7805-15WUP 22 F/50V 22 F/25V

                                                                     To produce a negative output, connect the output to pin 2
                                                                     and ground to pin 3, as shown in the diagram above.

                292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com
Typical Application Circuit 3, Pos/Neg Output                                   www.micropowerdirect.com

                      Typical application circuit 3 shows two units configured          Model     C1/C3       C2/C4    LDM1
                      with a common input connection to produce positive               Number
                      and negative outputs. The inductor LDM1 is added to                       10 F/50V  10 F/6.3V  10 H
                      reduce interference between the units. The recommended    MSR7805-033WUP  10 F/50V  10 F/6.3V  10 H
                      values for all the external components are given in the   MSR7805-05WUP   10 F/50V  10 F/6.3V  10 H
                      table at right.                                           MSR7805-12WUP   10 F/50V  10 F/6.3V  10 H
                                                                                MSR7805-15WUP
Characteristic Curves, Positive Output
                                                                                Characteristic Curves, Negative Output
Efficiency vs Input Voltage - (Full Load)
                                                                                Efficiency vs Input Voltage - (Full Load)

Efficiency vs Output Power - (VIN = Nominal)                                    Efficiency vs Output Power - (VIN = Nominal)

MicroPower Direct 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com
Typical Application Circuit 2: External EMC Components www.micropowerdirect.com

The diagram above illustrates a typical connection of the MSR7805WUP       3. Recommended values for components are:              4. The values for C1 and C2 are given in the
series for applications that require meeting EMC standards. Some notes on                                                            "Component Values" table on page 2.
this diagram (starting with the input circuit) are:                        Component    Value     Component             Value
1. It is recommended that an external fuse be used. The recommended fuse       MOV     S20K30        LDM2               12 H     5. The LC filter LOUT & COUT is only needed if very
                                                                               LDM1     82 H          C1             See Note 4     low ripple is required. Recommended values
   is shown in the model chart on page 2.                                       C3    680 F/50V       C2             See Note 4     for these components are given on page 2.
2. An external MOV is recommended on the input to protect the unit in the       C4    4.7 F/50V

   event of a surge. A recommended value is given in the table at right.

Mechanical Dimensions

                                                                                                                      Packing Carton

                                                                           Pin Connection

                                                                           Positive Output                      Notes:
                                                                                                                1. MSR7805WUP units are shipped in a product carton (inner carton)
                                                                           Pin        Function
                                                                                                                     which is then paced into a shipping carton. The shipping carton will hold
                                                                           1          +VIN                           two product cartons.
                                                                                                                2. Products are placed into individual slots cut into foam trays. A foam cover
                                                                           2          GND                            is then secured to the tray. Each tray will hold 140 units. Up to four trays
                                                                                                                     will fit into a product carton.
                                                                           3          VOUT
                                                                                                  Notes:
                                                                           Negative Output         All dimensions are typical in inches (mm)
                                                                                                   Tolerance x.xx = 0.01 (0.25)
                                                                           Pin        Function    Pin 1 is marked by a "dot" on the front of the unit

                                                                           1          +VIN

                                                                           2          VOUT

                                                                           3          GND

MicroPower Direct

We Power Your Success - For Less!

292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
搜索索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2021 EEWORLD.com.cn, Inc. All rights reserved