D9412G/D7412G                                                  Control/Communicators

Specifications                                           User Interface

Control Features                                          Supervises up to 8 command centers (up to 32
                                                              non-supervised command centers can be used)
Eight programmable areas, each with
     perimeter/interior partitioning. Regular, master,    Custom command center text
     associate, or shared option by area                  D7412G: 4 custom functions
                                                          D9412G: 16 custom functions
Real-time clock and test timer                         Full function command menu including custom
Up to 1000-event log, including time, date and
                                                              functions
     event with area, point and user number               D7412G: 99 Users
Battery charging circuit; AC power, voltage and         D9412G: 249 Users
                                                          Each user has authority by area and 16-character
     ground fault supervision
Automatic reset circuit protectors                          name
On-board CPU watchdog warning buzzer and                14 custom authority levels control user's authority

     diagnostic LEDs                                          to change, add, delete passcodes or access control
Lightning and EMI protection                                tokens/cards, disarm, bypass points, initiate system
Power limited external circuits                             tests, and more
                                                          Adjustable brightness/loudness for command
Communicator                                                  center display/ sounder
                                                          D7412G: 1 parallel printer
Built-in digital communicator with phone line          D9412G: 3 parallel printers
     monitor (loop or ground start)
                                                         Access Control
Multiple telephone numbers, primary and duplicate
     paths with main and alternate destinations          D7412G: 2 access control doors and 396
                                                              tokens/cards
All reports within each 4 route groups are
     programmable                                        D9412G: 8 access control doors and 996
                                                              tokens/cards
Optional dual phone line switcher monitors 2 phone
     lines                                                Custom door strike, point shunt and auto disarming
                                                              response by area
Automatic test and status reports
Time windows for arming and open/close report          Logging options for: Access Granted, No Entry,
                                                              Request to Exit and Request to Enter
     suppression
Programmable answering machine work-around for          14-panel wide access levels with both manual and
                                                              scheduled control
     remote programming on shared phone line

Programmable Outputs

2-amp alarm power @ 12 VDC
1.4-amp aux power @ 12 VDC
4 alarm output patterns
Automatic bell test
Programmable bell shut-off timer
D7412G: 67 programmable outputs
D9412G: 131 programmable outputs

System Response

D7412G: 75 points, 8 on-board, up to 67 off-board
D9412G: 246 points, 8 on-board, up to 238 off-

     board
31 custom point indexes, including fire supervisory
Selectable point response time
Fire alarm verification
Fire inspector's local test
Watch mode
Scheduled events (Skeds) arm, disarm, bypass and

     unbypass points, control relays, control authority
     levels, control door access and more
D9412G/D7412G                                              Each user may have a 16-character customized name
                                                           that may be viewed, printed, reported to a central station
System Description                                         in Radionics' Modem IIIa2 Communications format or
                                                           retrieved with Remote Account Manager (RAM).
D9412G/D7412G Control/Communicators provide an
integrated solution to Access Control, Security, and Fire  Security and Fire Detection
Alarm System applications.
                                                           D9412G/D7412G provide eight "on-board" detection
Control/Communicators are capable of monitoring alarm      points, and up to 238 additional off-board points
points for intruder or fire alarms while operating user    (depending on Model and expansion interfaces). Points
command centers, (access readers, door locks -             may be individually programmed and used to monitor all
D7412G/ D9412G), and other outputs. Includes a built-      types of burglar alarm, fire alarm, and supervision
in digital communicator, which reports events to           devices.
selected destinations via 4 programmable route groups.
                                                           Communications
Programming and accessory modules offer flexibility
and beneficial features rarely found in other security     D9412G/D7412G have four route groups, sort reports
control systems.                                           by priority and are capable of transmitting reports to up
                                                           to four locations. Each group has a programmable
Area Configurations                                        primary and backup destination. Compatible with D6600
                                                           NetCom Communications System using a D9133TTL-E
D9412G/D7412G area programming offers you a wide           Ethernet Interface Module. Radionics' Modem IIIa2
selection of different system configurations. Each area    Communications Format, available with Radionics'
is assigned an account number to define annunciation,      receiver, adds these reporting capabilities. To name just
control, and reporting functions. Multiple areas can be    a few:
linked to a shared area which is automatically controlled
(hallway or lobby). Area arming can be conditional on       Individual point numbers and text
other areas (master/associate).                            Opening/Closing reports by area number
                                                            Remote programming attempts
User Interface                                              Diagnostic reports
                                                            Access control events with user name
D9412G/D7412G command centers provide on-                  Event Log Storage, Viewing and Printing
premises point and system status annunciation. A fully
selectable user interface can customize command            D9412G/D7412G event log automatically stores up to
center displays and simplify operation by creating menu    1000 events. All local and transmitted events are stored
items and functions, appropriate only to that command      (some access events are selectable). Event log includes
center.                                                    time, date and event, with area, point and user number.
                                                           Users may view event log from Alpha Command
Function Lists can help a user become familiar with the    Centers. Events may be retrieved remotely using RAM.
operation of the control panel.
                                                           Events are printed as they are stored in event log.
Custom functions allow users to perform complex            D9131A Parallel Printer Interfaces can be installed to
functions with a few keystrokes. Each may be               record events locally on one, two, or three printers
programmed and identified by 16 characters of custom       (depending on model). Each can print opening and
text and contain up to 32 keystrokes.                      closing, access, alarm, Skeds, or any combination of
                                                           events. Each can print information from any combination
D1255 Command Center, D1256 Fire Alarm Command             of areas. Each can supervise various printer status
Center and D1257 Fire Alarm Annunciator use a 16-          conditions.
character English language display to show system
status, area status (custom text), and point status        Event log and local printer are ideally suited for
(custom text). D720 8-point LED area command center        customers who like to have a record of openings and
provides command functions and annunciation for up to      closings without having extra communications costs.
8 points in a single area. Any combination of these        Logger and RAM, can suppress reports and then
command centers may be used within the same area.          retrieve events periodically using one phone call, rather
                                                           than receiving several calls each day.
Easy to remember commands like Command 1,
Command 2, and Command 8 make an easy transition           When the panel's event log reaches its programmed
for seasoned Radionics users.                              threshold of stored events, it can send a report to a
                                                           receiver to remind central station to retrieve events from
User Passcodes                                             the panel's event log with RAM.

D9412G/D7412G can accommodate:

D7412G: 99 user passcodes
     D9412G: 249 user passcodes.
     (Each passcode individually programs with 3 to 6
     digits in length and no fixed digits).

Each user is assigned one of 14 customized authority
levels in each area. You may restrict passcodes to
operate only during certain times.

2001 Radionics  D9412G/D7412G Specifications             47487B
                                  Page 2
Scheduled Events (Skeds)                                                        D9412G/D7412G

D9412G/D7412G internal clock and calendar help the           D9210B Access Control Interface Module
panel operate individual scheduled events (Skeds).
Skeds perform a specific function (such as arm/disarm,       Access is granted from Wiegand format readers or
relay control, point bypassing, etc.). Each Sked is          Request to Enter/Exit devices when connected to the
programmed for a time and day-of-week schedule or a          D9210B.
date-of-year schedule.
                                                             Also provided are connections for door point, strike,
Users may change Sked Time if programmed for local           buzzer and enclosure tamper. (One D9210B required
time editing. Holiday schedules can enable or disable        per door).
individual Skeds during holiday periods.
                                                             Each access door can be configured independently
64 scheduled events with up to 26 different                Door point controls access door and is part of alarm
     functions
                                                                  system (door does not need double contacts)
Day-of-week or date-of-year schedules                      Door contact can reset strike time when opened
Four holiday schedules of 366 days each (leap               Door contact can terminate entry buzzer (if used)
                                                             Door contact is shunted when valid access is
     year)
                                                                  granted
Fire Test                                                    Optional buzzer can trigger prior to end of door

D9412G/D7412G Fire Test Mode suppresses reports to                shunt period, warning user a "door left open"
the central station receiver so you can test initiating and       condition is about to occur
indicating devices without transmitting alarms. Initiating    Door point can be configured to generate alarm or
Fire Test Mode, sends "Fire Walk Start" to central                trouble (or have no response) when door is left
station indicating start of test. Test events become "local       open beyond shunt period
only." Command center shows how many points are to            In addition to granting access, cards control
be tested.                                                        whether system will disarm along with granting
                                                                  access
Each time a device initiates an alarm, programmed point       Door strike can release automatically during
text displays at command center and the fire bell rings           disarmed periods, then automatically re-lock when
for 2 seconds. Automatic sensor reset feature allows              area is armed
continued testing of devices without time consuming          Door can generate an alarm, trouble, (or have no
trips to manually reset sensors. At the end of test,              response) depending on area's armed condition
command center displays the number of untested                    when door is opened outside authorized access
points. You can also view point text for each untested            period
point.                                                       REQUEST TO ENTER and REQUEST TO EXIT
                                                                  can be programmed to shunt door without
Ending Fire Test Mode, sends "Fire Walk End" to the               activating strike
central station receiver indicating end of test.             An option determines whether access granted, no
                                                                  entry, request to enter, or request to exit messages
Combining Access Control with Security and Fire                   are sent to event log
Detection (D7412G/D9412G)                                    RAM IV and RAM IV Lite

D9412G/D7412G combined systems can help prevent              These account management and panel-programming
false alarms making it easy to use one system that           utilities allow computers equipped with the Microsoft
controls access, security, and fire functions.               Windows operating system and a modem to act as a
                                                             remote programming, record storage, remote control
Access control features of D7412G/D9412G can deny            and troubleshooting tool for the D9412G/D7412G
access during armed periods, grant access only to            Control/Communicators. To enhance the down/upload
certain authorized users depending whether an area is        capabilities RAM can be used in a TCP/IP and Dynamic
master armed, perimeter armed or disarmed. Alarm             Host Communication Protocol (DHCP) configuration.
system can automatically disarm when designated
authorized users are granted access.

D7412G: Two (2) access doors; 75 detection
     points; 396 Token/Users

D9412G: Eight (8) access doors; 246 detection
     points; 996 Token/Users

47487B  D9412G/D7412G Specifications                         2001 Radionics
                        Page 3
D9412G/D7412G

Specifications                                              be equipped with a 16-character alphanumeric display,
                                                            distinct fire and burglary tones, and backlighted multi-
General                                                     key touchpad.

Contractor shall furnish and install, where indicated on    D1255, D1256, and D1257 shall have the ability to
plans, a Radionics D9412G/D7412G                            display for each detection point: alarm, trouble,
Control/Communicator. Panel shall be listed by              supervisory, or faulted, and custom text. In addition,
Underwriters Laboratories for NFPA 72 Applications.         expanded, addressable point displays shall include
                                                            missing and extra point information. System-wide
D9412G/D7412G shall support initiating and indicating       displays shall include: local system test, sensor reset,
modules and Radionics Command Centers. Power                fire test mode, and user programming prompts.
supply shall provide 1.4-amp @12 VDC for all
processing functions and auxiliary requirements.            Fire Test

Software                                                    D9412G/D7412G Fire Test Mode shall support single-
                                                            person operation. All reports to central station shall be
D9412G/D7412G programming of all system functions           suppressed while fire test is being conducted. Fire Test
shall be accomplished on site using Radionics' Hand-        Mode shall be activated by entering a user passcode at
held D5200 Programmer or remotely using a RAM               a command center. All testing data shall be visible on
software package. A programmable system passcode            command center and annunciator displays during
shall be used to prevent unauthorized remote                testing.
programming.
                                                            Hardware
Panel shall accommodate up to four separate telephone
numbers for primary, alternate and backup receivers,        D9412G/D7412G shall provide up to 246 individually
automatic test reports, selective relay activation, and     identified addresses, (75 with D7412G). Each shall
custom text on associated command centers and               accommodate normally open and/or normally closed
annunciators.                                               devices with end-of-line resistor supervision. Each point
                                                            shall be programmable for fire, fire supervisory or
When resetting alarms, arming or disarming a                burglary applications. Point output shall be silent or
combination fire/burglary and/or access control system,     audible. Audible output shall be steady, pulsed, CA
the user shall be identified by name and number.            standard, or temporal code 3.

D7212/D7412G: Up to 99 users                                External Hardware
D9112/D9412G: Up to 249 users
                                                            D9412G/D7412G shall allow use of up to three on-site
Panel's internal clock shall support Skeds (scheduled       parallel printers (one with D7412G), using Radionics
events) feature. User shall have option to alter Sked       D9131A Printer Interface Modules. Events shall print
activation times using a programmable passcode.             time, date, and event description with area, account,
                                                            point, and user number, including text for points and
Up to 64 programmable, scheduled event functions shall      users.
be available for controlling relays, enabling passcodes,
windows, and supporting service alert feature.              Installation, Warranty, and Training

Other programmable functions shall include fire alarm       D9412G/D7412G System Installation, wiring of initiating
reset commands, and day/date/time adjustments.              devices and signaling circuits, shall be the responsibility
                                                            of installing company.
Event Logger/Clock
                                                            Warranty on all components shall be two years, subject
D9412G/D7412G event log shall store up to 1000              to manufacturer's limitations. Training on complete
events. All system events shall include time, date and      system operation shall be furnished by installing
event with area, point and user number.                     company upon completion of installation.

Access events (optional) stored shall include: Access
granted, No Entry, Request To Enter, and Request To
Exit. Logger records certain functions entered at
command centers. Stored events in Logger shall be
retrievable with a RAM software package.

Remote Diagnostics and Controls

D9412G/D7412G shall be able to be remote controlled
through use of RAM software. Features shall include:
reset of audible signals, activation/deactivation of D8129
relays, interrogation of battery, point and armed status,
enabling or disabling reporting functions, and shunting
of reporting points during servicing.

Command Centers

D9412G/D7412G command centers shall be Radionics
D1255 Command Center, D1256 Fire Alarm Command
Center and D1257 Fire Alarm Annunciator. Each shall

2001 Radionics                 D9412G/D7412G Specifications  47487B
                                                 Page 4
                                                                         D9412G/D7412G

Accessories/Ordering Information

Model Description                                   Model Description
Command Centers, Keypads and Accessories:
D1255 Command Center                                Fire Alarm Modules and Accessories:

                                                    D125B Dual Class B Powered Loop Interface Module

D1256 Fire Alarm Command Center                     D129 Dual Class A Initiation Circuit Module

D1257 Fire Alarm Annunciator                        D130 Auxiliary Relay Module, 12/24 VDC

D720    8 Point LED Area Command Center             D184 Auxiliary Local Energy Interface Kit

D268    Independent Point Control Module            D185 Reverse Polarity Interface Module

D269    Independent Point Control Keypad            D192C N.A.C. Module, Class B, 12/24 VDC, 1.8-amp

D279    Independent Point Control                   D192D N.A.C. Module, Class A/B, 12/24 VDC, 3-amp

D54B Command Center Flush Mount Kit, Brass          D928 Dual Phone Line Switcher

D54C Command Center Flush Mount Kit, Stainless      D8130 Release Module

D55     Command Center Desk Stand                   Power Supplies, Transformers, Batteries &
                                                    Accessories:
D56     Command Center Surface Mnt. Conduit Box
                                                    D9142F Auxiliary Power Supply, 24 VDC, 4-amp
Zone Expansion and Interface Modules:

D8125   POPEX Module                                D8132 Battery Charger Module, 12 VDC

D9127U/T POPIT Module, U=No Tamper /                D1640 16.5 VAC 40 VA Transformer
                  T= Tamper
                                                    D113    Battery Lead Supervision Module

D8128C OctoPOPIT Module                             D122/L Dual Battery Harness/Long Leads

D940    Super Loop Module                           D126    Battery, 12 V, 7.5 Ah

D8129   OctoRelay Module                            D1218 Battery, 12 V, 17.2 Ah

D127    Reversing Relay                             Enclosures, Brackets, and Phone Cords:

D136    Plug-in Relay                               D8103   Universal Enclosure

D8121A Derived Channel S.T.U. Non UL                D8109   Fire Enclosure

D8122   Derived Channel S.T.U. UL Listed            D8108A Attack Resistant Enclosure

D9131A Parallel Printer Interface Module            D8004   Transformer Enclosure

D9210B Access Control Interface Module              D137    Module Mounting Bracket

Detection Devices with Built-in POPIT:              D101    Lock and Key for D8103

ZX835   PIR/Microwave Detector, 35 x 35 ft.         D161/162 Dual Mod. Telephone Phone Cord, 7 ft.
        (10.7 x 10.7 m)                                             (2.1 m) / 2 ft. (61 cm)

ZX970   PIR/Microwave Detector, 60 x 60 ft.         Programming Products:
        (18.3 x 18.3 m)
                                                    D5200   Hand-held Programmer

ZX935Z PIR Detector, 35 x 35 ft. (10.7 x 10.7 m)    D5500-  Remote Account Manager, RAM IV
                                                    ####*
ZX776Z PIR Detector, 50 x 50 ft. (15 x 15 m)

ZX794   PIR Detector, 90 x 90 ft. (27 x 27 m)       D5500-  RAM IV Lite
                                                    ####*-
ZX938Z  PIR Detector, Ceiling Mount, 360 x 60 ft.  LTE
        (18 m)

D278S   Smoke Detector Base 12 VDC                  * #### represents the version number of the software.
                                                    Order Processing has the latest revision information.

D298M   Smoke Detector Base, Master, 24 VDC

D298S   Smoke Detector Base, 24 VDC

47487B                                    D9412G/D7412G Specifications                2001 Radionics
                                                          Page 5
D9412G/D7412G

Listings and Approvals

Fire
UL: Central Station, Local, Auxiliary, Remote

     Station, and Household Fire Warning.
CSFM: Approved for highrise and non-highrise.
Burglary
UL: Central Station, Local, Police Connect, Bank

     Safe and Vault, Mercantile Safe and Vault, and
     Grade A Household
DOD: Approved for installations in Sensitive
     Compartmented Information Facilities (SCIF).
Access
UL: Access Control Systems.

2001 Radionics  D9412G/D7412G Specifications       47487B
                                  Page 6
                                      D9412G/D7412G

        Notes

47487B  D9412G/D7412G Specifications   2001 Radionics
                        Page 7
2001 Radionics, a division of Detection Systems, Inc.  47487B                          7/01
PO Box 80012, Salinas, CA 93912-0012, USA                Specifications  D9412G/D7412G
Customer Service: (800) 538-5807
                                                                               Page 8 of 8
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
搜索索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2021 EEWORLD.com.cn, Inc. All rights reserved