Solid-state Timer                                                                                       RC

H3BA-N                                                                                          H3BH-N

Please read and understand this catalog before purchasing the products.
Please consult your OMRON representative if you have any questions or
comments. Refer to Warranty and Application Considerations (page 20),
and Safety Precautions (page 16).

Solid-state Timer with Valuable Multiple-time
Ranges and Multiple-operating Modes

Handles a wide range of applications through six operating
modes.

With H3BA-N8H models, the output type can be switched
between time-limit DPDT and time-limit SPDT + instantaneous
SPDT using a selector.

Setting rings (order separately) to enable consistent settings
and to limit the setting range.

Panel Covers (order separately) to enable various panel
designs.

Conforms to LR and approved by UL and CSA.

Broad Line-up of H3B@-N Series

                                           H3B@-N

H3BA-N                    H3BF-N                                         H3BG-N

Multi-functional Timer    Twin Timer               Star-delta Timer                              Power OFF-delay Timer
                                                                                                 H3BH-N8 8-pin model
H3BA-N    11-pin model    H3BF-N8     8-pin model  H3BG-N8                       8-pin model
H3BA-N8H  8-pin with                               H3BG-N8H                      8-pin with
          instantaneous                                                          instantaneous
          contact output                                                         contact output
          and time-limit
          output

Note: Refer to the H3BF-N/BG-N/BH-N Datasheet (Cat. No. L094-E1-1) for details.

                                                                                 Solid-state Timer H3BA-N               1
Model Number Structure

Model Number Legend

H3BA-N@

                  1
1. Number of Pins/Output

    None: 11-pin models/Time-limit DPDT
    8H: 8-pin models/Time-limit SPDT and switchable SPDT (time-limit  instantaneous)

Ordering Information

List of Models

                    Control output                          Supply voltage            11-pin models             8-pin models
Contact output: DPDT (time-limit output)          110 VAC (50/60 Hz)        H3BA-N 110 VAC           ---
                                                  220 VAC (50/60 Hz)        H3BA-N 220 VAC
Contact output: Time-limit SPDT and               24 VDC                    H3BA-N 24 VDC            H3BA-N8H 110 VAC
                     switchable SPDT              110 VAC (50/60 Hz)        ---                      H3BA-N8H 220 VAC
                     (time-limit  instantaneous)  220 VAC (50/60 Hz)                                 H3BA-N8H 24 VDC
                                                  24 VDC

Accessories (Order Separately)

                                         Name/specifications                                         Models
Flush Mounting Adapters
                                                                            Y92F-30
Mounting Tracks                50 cm (l) 7.3 mm (t)                       Y92F-70
                               1 m (l) 7.3 mm (t)                         Y92F-71
End Plate                      1 m (l) 16 mm (t)                          PFP-50N
Spacer                                                                      PFP-100N
Protective Cover               8-pin                                        PFP-100N2
Track Mounting/                11-pin                                       PFP-M
Front Connecting Sockets       8-pin                                        PFP-S
Back Connecting Sockets        11-pin                                       Y92A-48B
                               Setting a specific time                      P2CF-08
Time Setting Ranges            Limiting the setting range                   P2CF-11
                               Light gray (5Y7/1)                           P3G-08
Panel Covers (See note 1.)     Black (N1.5)                                 P3GA-11
                               Medium gray (5Y5/1)                          Y92S-27
Hold-down Clips (See note 2.)  For PL08 Socket                              Y92S-28
                               For PF085A Socket                            Y92P-48GL
                                                                            Y92P-48GB
                                                                            Y92P-48GM
                                                                            Y92H-1
                                                                            Y92H-2

Note: 1. The Time Setting Ring and Panel Cover are sold together.
        2. Hold-down Clips are sold in sets of two.

2  Solid-state Timer H3BA-N
Specifications

General                                        H3BA-N                                              H3BA-N8H

                  Item   A: ON-delay                                     A: ON-delay
Operating mode
                         B: Flicker OFF start                            H: ON-delay with instantaneous output contact
Pin type
Input type               B2: Flicker ON start
Output type
Mounting method          C: Signal ON/OFF-delay
Approved standards       D: Signal OFF-delay

                         E: Interval

                         11-pin                                          8-pin

                         No-voltage input                                ---

                         DPDT (time-limit)                               SPDT (time-limit) and switchable SPDT (time-limit <--->
                                                                         instantaneous)

                         DIN track mounting, surface mounting, and flush mounting

                         UL508, CSA C22.2 No.14,
                         Conforms to LR (currently under application and approval is expected by the end of Feb. 2006)

Time Ranges

         Time unit                     s (sec)                  min                        h (hrs)             10 h (10 h)
                         0.05 to 1.2            0.12 to 1.2                                         1.2 to 12
Setting  1.2             0.3 to 3                                                                   3 to 30
                         1.2 to 12                                                                  12 to 120
         3               3 to 30                                                                    30 to 300

         12

         30

Ratings

                Item                                     H3BA-N                                     H3BA-N8H
Rated supply voltage     110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC
(See notes 1 and 2)
Operating voltage range  85% to 110% of rated supply voltage
(See note 3)
Power reset              Minimum power-opening time: 0.1 s
No-voltage input
                         ON impedance: 1 k max.
Power consumption
                         ON residual voltage: 1 V max.
Control outputs
                         OFF impedance: 200 k min.

                         110 VAC: Approx. 4.6 VA (1.5 W)                 110 VAC: Approx. 3.6 VA (1.6 W)

                         220 VAC: Approx. 7.9 VA (1.3 W)                 220 VAC: Approx. 5.4 VA (1.4 W)

                         24 VDC: Approx. 0.6 W                           24 VDC: Approx. 0.9 W

                         Contact:               5 A at 250 VAC, resistance load (cos = 1)

Note: 1. DC ripple rate: 20% max.
        2. Models other than 24-VDC H3BA-N models cause an inrush current. Pay careful attention when attempting to turn on power to such
            models with non-contact output from a device such as a sensor.
        3. 90% or higher if the Timer is used continuously at a high ambient temperature.

                                                                                   Solid-state Timer H3BA-N                                3
Characteristics

                    Item                                                   H3BA-N                                                                          H3BA-N8H
Accuracy of operating time
Setting error                                         0.3% FS max. (0.3%10 ms in a range of 1.2 s)
Reset time
Influence of voltage                                  5% FS 0.05 s max.
Influence of temperature
Insulation resistance                                 Min. power-opening time: 0.1 s max.
Dielectric strength
                                                      Min. pulse-input time: 50 ms
Impulse withstand voltage
                                                      0.5% FS max. (0.5%10 ms in a range of 1.2 s)
Noise immunity
                                                      2% FS max. (2%10 ms in a range of 1.2 s)
Static immunity
Vibration resistance                                  100 M min. (at 500 VDC)
Shock resistance
                                                      2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal
Ambient temperature                                   parts
Ambient humidity                                      2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit
Life expectancy                                       1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-N8H)

Case color                                            1 kV (between power terminals)
Enclosure ratings                                     2 kV (between current-carrying terminal and exposed non-current-carrying metal parts,
Weight                                                1.5 kV for 24-VDC models)

                                                      AC models: 1.5 kV (between power terminals), and 600 V (between input terminals),
                                                                      square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise)

                                                      DC models: 480 V (between power terminals), and 600 V (between input terminals),
                                                                      square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise)

                                                      Malfunction: 4 kV

                                                      Destruction: 8 kV

                                                      Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions

                                                      Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions

                                                      Destruction: 1,000 m/s2 (approx. 100G) each in three directions

                                                      Malfunction: 100 m/s2 (approx. 10G) each in three directions

                                                      Operating: 10C to 55C (with no icing)
                                                      Storage: 25C to 65C (with no icing)

                                                      Operating: 35% to 85%

                                                      Mechanical: 20 million operations min. (under no load Mechanical: 10 million operations min. (under no

                                                              at 1,800 operations/h)                                          load at 1,800 operations/h)

                                                      Electrical: 100,000 operations min. (5 A at 250 VAC, Electrical: 100,000 operations min. (5 A at 250

                                                              resistive load at 1,800 operations/h)                           VAC, resistive load at 360 operations/h)

                                                      Light gray (Munsell 5Y7/1)

                                                      IEC: IP40 (panel surface)

                                                      Approx. 95 g

Note: For setting the time-limit of the Timer to a cycle of less than 3 seconds or applying the forced reset, use the H3BA-N in mode D (signal OFF-
        delay).

Nomenclature

H3BA-N                                                                                        H3BA-N8H

        Power Indicator (Green):                         Operating Mode Display Window                 Power Indicator (Green):                            Output Type Display Window
        Lit when Timer operates.                                                                       Lit when Timer operates.

                                    PW                MODE A                                                                       PW                      MODE A    Output Type Selector:
                                                                                                                              UP                                     Select a type from A
Output Indicator (Orange):      UP                                  Operating Mode Selector:  Output Indicator (Orange):                                   2         and H
    Lit when Timer outputs.                                         Select a mode from            Lit when Timer outputs.                             1.5            A: Time-limit DPDT
                                            1.5                     A, B, B2, C, D, and E                                                                      2.5
     Time Range Selector:                                           Scale Range Display            Time Range Selector:                 1                               (default setting)
              Select one from            1            2             Windows                                Select one from                                  3        H: Time-limit SPDT and
                                                                                                                                      0.5
           1.2, 3, 12, and 30.      0.5                  2.5        Time Unit Selector                   1.2, 3, 12, and 30.                                            instantaneous SPDT
                                                                    Select a unit from                                                0
                                                                    sec, min, hrs, and 10h.                                                                          Scale Range Display
                                                                                                                                                                     Windows

                                        0             3

                                                 sec                                                                                                 sec
                                    H3BA                                                                                                H3BA

                                Time setting knob (set time)                                                                  Time setting knob (set time)           Time Unit Selector
                                                                                                                                                                     Select a unit from sec,
                                                                                                                                                                     min, hrs, and 10 h.

4       Solid-state Timer H3BA-N
Operation                                                        Time range/     Operating
                                                                 unit selectors  mode selector
Block Diagrams

H3BA-N

                                     AC (DC) input

                         Power supply               Oscillation  Counting        Output circuit
                         circuit                    circuit      circuit

                Reset input, start input, and gate input         Input circuit   Indicator
                                                                                 circuit

                                                                                 Power-ON Output-ON
                                                                                 indicator indicator

H3BA-N8H

                AC (DC) input                                    Time range/     Output type
                                                                 unit selectors  selector

                         Power supply               Oscillation  Counting        Output circuit
                         circuit                    circuit      circuit

                                                                                        Indicator
                                                                                        circuit

                                                                                 Power-ON Output-ON
                                                                                 indicator indicator

                                                                                     Instantaneous
                                                                                     output circuit

I/O Functions

Inputs   Start           Starts time-measurement.
         Reset           Interrupts time-measurement and resets time-measurement value. No time-measurement is made and
                         control output is OFF while the reset input is ON.
Outputs  Gate            Prohibits time-measurement.
         Control output  Outputs are turned ON according to designated output mode when preset value is reached.

                                                                                Solid-state Timer H3BA-N                 5
Basic Setting                                                                                   Using the Setting Ring

Setting of Selector                                                                             Setting a Specific Time

The selectors can be turned clockwise and counterclockwise to                                   Mount the Panel Cover on the Timer, set the desired time with the
select the desired time unit, time range, output type (only for H3BA-                           time setting knob, and place Time Setting Ring A onto the time
N8H) or operating mode.                                                                         setting knob so that the time setting notch of Time Setting Ring A is
Each selector has a snap mechanism that secures the selector at a                               in the center of the reset lock position of the Panel Cover.
given position. Set the selector at a position at which it is secured. Do
not set it midway between two securing positions or a malfunction                                             Time setting  Reset lock  position
could result from improper setting.                                                                           notch

   Operating mode selector/
   Output type selector

                             Operating mode/                                                    Time setting ring A Panel cover
                             Output type                                                                          Time setting notch
                             display window

                                                                                                                                                  Setting position

                                                                                   Groove for                 Example: To set the time to 10 s.
                                                                                   screwdriver
                                                                                                Limiting the Setting Range
Selection of Operating Mode with H3BA-N
                                                                                                Example: To set a range of 10 and 20 s.
Turn the operating mode selector with a screwdriver until the desired                           Mount the Panel Cover on the Timer, set the time setting knob to 10 s
operating mode (A, B, B2, C, D, or E) appears in the display window                             (the lower limit of the setting range), and place Time Setting Ring C
located above the selector.                                                                     onto the time setting knob so that the stopper of Time Setting Ring C
                                                                                                is on the right edge of the reset lock position of the Panel cover. Next,
Selection of Output Type with H3BA-N8H                                                          set the time setting knob to 20 s (the upper limit of the setting range),
                                                                                                place Time Setting Ring B onto the time setting knob so that the
Turn the output type selector with a screwdriver until the desired out-                         stopper of Time Setting Ring B is on the left edge of the reset lock
put type (A or H) appears in the display window located above the                               position of the Panel Cover.
selector.
                                                                                                Stopper       Reset lock position
Selection of Time Unit and Time Range

The desired time unit (sec, min, hrs, or 10h) is displayed in the
window below the time setting knob by turning the time unit selector
located at the lower right corner of the front panel. A time range (1.2,
3, 12, or 30) is selected with the time range selector at the lower left
corner of the front panel, and the selected time range appears (in the
window at the lower right part) within the plastic frame of the time
setting knob.

                                                                                                Time setting  Time setting Panel cover
                                                                                                ring B        ring C

                                                                                                                                                       Range

   Time range                            Operating mode
   selector                              display window

                             Time unit selector

                             Time unit display window

Setting of Time

Use the time setting knob to set the desired time.

6  Solid-state Timer H3BA-N
Timing Chart

Note: 1. The minimum power-opening time ("Rt") is 0.1 s and the minimum pulse width is 0.05 s.
        2. The letter "t" in the timing charts stands for the set time and "ta" means that the period is less than the time set.

H3BA-N

    Operating mode                                                                                             Timing chart

A: ON-delay                                                                                                          t

                                                                                      t                                         Basic operation

                                             Power                                                                              Power
                                             2 and 10
                                                                                                                                  Start
                                             Start                                                                                                           t
                                             2 and 6
                                             Reset                                                                              Output
                                             2 and 7
                                                                                               t-a       t     t  t
                                             Output relay (NC)                           t
                                             1 and 4 (11 and 8)
                                                                                                                                Basic operation
                                             Output relay (NO) 1
                                             and 3 (11 and 9)                                                                   Power
                                             and output indicator
                                                                                                                                Start
                                             Power indicator
                                                                                                                                           t                       t     t     t
B: Flicker OFF start
                                                                                                                                Output
                                                                                     t
                                                                                               t-a       t     t  t
                                              Power                                      t
                                              2 and 10
                                                                                                                                Basic operation
                                              Start
                                              2 and 6                                                                           Power

                                              Reset                                                                             Start
                                              2 and 7
                                              Output relay (NC)                                                                            t                       t     t     t
                                              1 and 4 (11 and 8)
                                                                                                                                Output
                                              Output relay (NO)
                                              1 and 3 (11 and 9)                                    t-a           t-a t-a
                                              and output indicator
                                                                                         t                  t                t
                                              Power indicator
                                                                                                                                 Basic operation
B2: Flicker ON start
                                                                                                                                Power
                                                                                     t
                                                                                                                                Start
                                               Power
                                               2 and 10                                                                                 t                       t     t     t

                                               Start                                                                            Output
                                               2 and 6

                                               Reset
                                               2 and 7
                                               Output relay
                                               1 and 4 (11 and 8)
                                               (NC)
                                               Output relay (NO)
                                               (Output indicator)
                                               1 and 3 (11 and 9)

                                               Power indicator

C: Signal ON/OFF-delay

                                                                                 t
                                              Power
                                              2 and 10

                                              Start
                                              2 and 6

                                              Reset
                                              2 and 7
                                              Output relay
                                              1 and 4 (11 and 8)
                                              (NC)
                                              Output relay (NO)
                                              (Output indicator)
                                              1 and 3 (11 and 9)
                                              Power indicator

                                                                                                                             Solid-state Timer H3BA-N                             7
   Operating mode                                                                  Timing chart

D: Signal OFF-delay                                                                                            t-a          t-a

                                                                 t                     t-a                          t

                     Power
                     2 and 10

                     Start
                     2 and 6

                     Reset
                     2 and 7

                     Output relay
                     1 and 4 (11 and 8)
                     (NC)

                     Output relay (NO)
                     (Output indicator)
                     1 and 3 (11 and 9)

                     Power indicator

                                             Basic operation Power

                                                                         Start                 t
                                                                       Output

E: Interval                                                                                                    t-a  t-a

                                                                    t           t           t                            t

                                             Power
                                             2 and 10

                                             Start
                                             2 and 6

                                             Reset
                                             2 and 7

                                             Output relay
                                             1 and 4 (11 and 8)
                                             (NC)

                                             Output relay (NO)
                                             (Output indicator)
                                             1 and 3 (11 and 9)

                                             Power indicator

                                             Basic operation                    Power

                                                                                  Start
                                                                                                            t

                                                                                Output

Gate Signal Input in Operating Mode A (ON-delay Operation)

              t1     t2

          ON
Power OFF

        ON
Start OFF

        ON
Gate OFF

         ON
Reset OFF

Output ON
relay OFF

Note: The set time is the sum of t1 and t2.

8             Solid-state Timer H3BA-N
H3BA-N8H, Output Type: A Type

    Operating mode                                      Timing chart
A: ON-delay
                                                                Rt                                      Rt t - a
                                                  t                                               t      Rt t - a

                         Power 2 and 7
                         Output relay (NC)
                         8 and 5 (1 and 4)

                         Output relay (NO)
                         8 and 6 (1 and 3)
                         and output indicator

                         Power indicator

                               Basic operation Power

                                                                                            t
                                                                 Output

H3BA-N8H, Output Type: H Type

    Operating mode                                      Timing chart

H: ON-delay with                                     t          Rt                                   t
   instantaneous output
   contact               Power 2 and 7

                         Output relay
                         8 and 5 (NC)
                         Output relay 8 and 6
                         (NO) (output indicator)
                         Instantaneous 1 and
                         4 output relay (NC)

                         Instantaneous 1 and
                         3 output relay (NO)

                         Power indicator

                               Basic operation          Power

                                                                                               t

                                                        Output

                                                                                                  Solid-state Timer H3BA-N  9
Dimensions                                                                                                       15                                             78

Note: All units are in millimeters unless otherwise indicated.                                                         6  63.7                                           13.6

H3BA-N                                                                                                                                                              0.7

                                                                                             48         39 dia.                                                                44.8 44.8
                                                                                                                                                                         11 pins
             PW
        UP

                                                                          48

H3BA-N8H                                                                                                         15                                             78

             PW                                                                                                        6  63.7                                           13.6
        UP                                                                                                                        0.7
                                            48
                         48                                                                             39 dia.                                                                   44.8 44.8
                                                                                                                                                                         8 pins

Dimensions with Set Ring                                                                                         16.5

                                                                                             50         42 dia.

                                                                         50

                                                                                                                  Time setting ring Panel cover                          P3G Back Connecting Socket
                                                                                                                                                                         (sold separately)
Dimensions with Y92F-30 Flush Mounting Adapter

                                                                                                                                                         Panel

                     PW

                 UP      58                                                                             52

                                                                                                    42                                                                         Panel Cutout
                                                                                                    48
                                                                                                                                                                         0.5 R max.  45+-00.6
Note: The mounting panel thickness should be 1 to 5 mm.                                                                                                                              (N)

                                                                                                                                                                         45+-00.6

10  Solid-state Timer H3BA-N
Dimensions with Y92F-70 Flush Mounting Adapter                                                                                                  Panel Cutout

                                                                                                                         Panel              Adapter mounting hole Two, 4.5 dia.

                                       45                                                                                               R0.5 max. 52 to 53

                    PW                 88 0.15

                UP

                                                                                                                                                 65 to 66                      760.2

                                                  450.15
                                                     58

Dimensions with Y92F-71 Flush Mounting Adapter

                                                  56               Panel                                                                         R0.5 max.           45+-00.5

                    PW

                UP                                                                                                                                         55+-00.5

                                       58 450.2             68

                                                  430.2                                                                                 Note: The mounting panel thickness
                                                   50+-00.2                                                                                      should be 1 to 3.2 mm.

Track Mounting                                                     Flush Mounting

                                                                   15                                                                            15
                                                                                      91.4                                                                        86.4

        H3BA-N                                                                                                                  H3BA-N
                                                                                                                                +
112.2*                                 H3BA-N8H                                                                                 Adapter                              H3BA-N8H

                        109.9  101.3*             99

                                                                                                                                Y92F-30 P3GA-11            Y92F-30 P3G-08

        P2CF-11 2.3*                   P2CF-08 2.3*

Note: These dimensions vary with the kind of DIN track (reference
        value).

                                                                                                                                         Solid-state Timer H3BA-N                      11
Accessories (Order Separately)

Track Mounting/Front Connecting Socket

P2CF-08                            Eight,                                                                   Terminal Arrangement/
                                                                                                            Internal Connections
                                                                  7.8          3             4.5            (Top View)

                                   M3.5 7.5 sems                                                                                      Surface Mounting Holes

                                   70 max.                                                          35.4                                        Two, 4.5 dia. or two, M4
                                                                                                                                                 400.2
                                     4                            Two, 4.5 dia.
                                                    50 max.       holes                                                                         Two, 4.5 dia. or two, M4

                                       Eleven,                                    20.3 max.
                                       M3.5 7.5 sems
P2CF-11                                                                     3                4.5

                                                                  7.8

                                                                                                                                        400.2

                                   70 max.                                                            35.4
                                                                  Two, 4.5 dia.
                                     4                            holes
                                                    50 max.
                                                                                     31.2 max.

Back Connecting Socket

P3G-08                                                                                                      Terminal Arrangement/
                                                                                                            Internal Connections
                                               27 dia.                                                      (Bottom View)

                                   45

                                                45                          4.9   17
                                               27 dia.
P3GA-11

                                               45                                            25.6

                                                              45            4.5              6.2

Mounting Track                                                                    16.3

PFP-100N, PFP-50N                                                                       PFP-100N2

                                                                                                                                                      16

4.5                                                               7.30.15              4.5
                                                                    350.3
                                                                            270.15                                                     350.3 27 24      29.2

     15 25 25                      25          25 *                            1                          15 25 25            25 25 15          1         1.5
                                                                                                                                    10
                10                         10                                                               10
                                L                                                                                   L

         L: Length

         1 m PFP-100N
         50 cm PFP-50N
         1 m PFP-100N2

12       Solid-state Timer H3BA-N
End Plate                                                                           Time Setting Ring/Panel Cover

PFP-M                                        10                                     There are three types of Panel Covers (Y92P-48GL, Y92P-48GB,
                                             6.2 1.8                                and Y92P-48GM), all of which are available in three colors. Use the
Spacer                                                                              most suitable type of Panel Cover with the design of the scaling plate
                                             1       35.5 35.3                      according to the application.
PFP-S                                           1.8                                 When setting a given time for the Timer, use of the Y92S-27 or
           50                                                                       Y92S-28 Time Setting Ring facilitates the time setting operation and
                                                                                    minimizes possible setting errors by operators.

                                                                                    The Time Setting Ring and Panel Cover should be used as a pair.

                    11.5                     1.3                                    Setting a specific time Time Setting Ring A (Y92S-27) and Panel
                              10 M4 8      4.8                                                                      Cover (Y92P-48GL, -48GB, or -48GM)
                                   pan head

                       screw                                                        Limiting the setting  Time Setting Ring B or C (Y92S-28), and
                                                                                    range                 Panel Cover (Y92P-48GL, -48GB, or -
                                                                                                          48GA)

                              16                                                    Y92S-27               Y92S-28         Y92S-28
                                                                                    Time Setting A        Time Setting B  Time Setting C
                    5         12

                                               34.8
                       44.3

                                                                              16.5  Y92P-48GL             Y92P-48GB       Y92P-48GM
                                                                                    Light Gray            Black           Medium Gray
Protective Cover
                                                                                    Hold-down Clip                   Y92H-2
Y92A-48B                                                                                                             For PF085A Socket
                                                                                    Y92H-1
The protective cover protects the front panel, particularly the time                For PL08 Socket
setting section, against dust, dirt, and water. It also prevents the set
value from being altered due to accidental contact with the time
setting knob.
Note: 1. The Y92A-48B Protective Cover is made of a hard plastic

               and therefore it must be removed to change the timer set
               value.
           2. The Protective Cover cannot be mounted if the Panel Cov-
               er (sold separately) is used on the Timer.

Y92A-48B

                PW
           UP

                                                                                                    Solid-state Timer H3BA-N              13
Installation

Terminal Arrangement

H3BA-N (Contact Output)

Reset input
       Start input
              Gate input

                           ()(~) Power supply (+)(~)

H3BA-N8H (Contact Output)

                                                                     Note: The delayed contacts of conventional timers
                                                                               are shown as follows:

       A                  H                                          The contact symbol of the H3BA-N is ex-
                                                                     pressed as follows because of its multiple op-
             MODE            Power supply                            erating modes:
          (See note.)
                                                                     The instantaneous contacts of conventional
                                                                     timers are shown as follows:

                             (-)(~) (+)(~)

Note:  The output contact can be set to either instantaneous or
       time-limit contact using the output type selector located at
       the upper right corner of the front panel.

14        Solid-state Timer H3BA-N
Input Connections

The inputs of the H3BA-N are no-voltage (short circuit or open) inputs.

No-voltage Inputs

No-contact Input                     Contact Input                       No-contact Input
(Connection to NPN open                                                  (Connection to a voltage
collector output sensor.)                                                output sensor.)

12 to 24 VDC                                                             12 to 24 VDC
(sensor power supply)                                                    (sensor power supply)

                       + DC power                                                               + DC power
                       - supply                                                                 - supply

Sensor                 Timer                        Timer                                        Timer

                                                                         Sensor                 Start/reset/
                                                                                                gate
                       Start/reset/            Start/reset/                                     Input (0 V)
                       gate                    gate                                             (No. 2 pin)

                       Input (0 V)             Input (0 V)
                       (No. 2 pin)             (No. 2 pin)

Operates with transistor ON          Operates with relay ON              Operates with transistor ON

No-voltage Input Signal Levels

No-contact  1. Short-circuit level
input
            Transistor ON

            Residual voltage: 1 V max.
            Impedance when ON: 1 k max.

Contact     2. Open level
input       Transistor OFF
            Impedance when OFF: 200 k min.

            Use contacts which can adequately
            switch 0.1 mA at 5 V

                                                                                 Solid-state Timer H3BA-N     15
Safety Precautions                                                         Precautions for Correct Use

                                CAUTION                                   Changing the Setting

Minor electric shock may occasionally occur. Do not                       Do not change the time unit, time range, or operation mode while the
disassemble the product or touch the interior of the Timer.               Timer is in operation, otherwise the Timer may malfunction.

Minor burns may occasionally occur. Do not touch the                      Connecting the Operating Power
product while power is being supplied or immediately                      Supply
after power is turned OFF.
                                                                          The H3BA-N@ contains a capacitor-drop power circuit. Use a
Minor fires may occasionally occur. Tighten terminal                      sinusoidal power supply with a commercial frequency. Do not use
screws to a torque of 1.08 Nm so that they do not                        power supplies with a high frequency component (such as inverter
become loose.                                                             power supplies) for Timers with 110 or 220-VAC specifications. Using
                                                                          these power supplies can damage internal circuits.
Minor electric shock may occasionally occur during
operation. Install the terminal cover.                                    If voltages other than the rated voltage is applied, the internal
                                                                          components may be damaged. The internal element (varistor) will be
Minor electric shock, fire, or malfunction may occasionally               damaged if a voltage of higher than 100 VAC is applied to the 24-
occur.                                                                    VDC line.
Do not allow metal fragments, lead wire scraps, or chips
from processing during installation to fall inside the Timer.             Connect the power supply voltage through a relay or switch in such a
                                                                          way that the voltage reaches a fixed value immediately or the Timer
Precautions for Safe Use                                                 may not be reset or a timer error could result.

Please observe the following precautions for safe use of this product.    A DC power supply can be connected if its ripple factor is 20% or
                                                                          less and the mean voltage is within the rated operating voltage range
Environmental Precautions                                                 of the Timer.

Store the Timer within specified ratings. If the Timer has been stored    If the wiring to the terminal 2 (common terminal for both the power
at -10C or lower, let it stand for 3 hours or longer at room             supply and input signals) is broken, the internal circuit will be
temperature before turning ON the power supply.                           destroyed.
Use the Timer within the specified ratings for operating temperature
and humidity.                                                                                   5, 6, 7                  10
Do not operate the Timer in locations subject to sudden or extreme                              G, S, R           H3BA-N
changes in temperature, or locations where high humidity may result
in condensation.                                                                               Input terminal
Do not use the Timer in locations subject to excessive dust, corrosive
gas, or direct sunlight.                                                                       Closed
Do not use the Timer in locations subject to vibration or shock.                                                                  2
Extended use in such locations may result in damage due to stress.
Install the Timer well away from any sources of static electricity, such  Input/Output
as pipes transporting molding materials, powders, or liquids.
                                                                          An appropriate input will be applied to the input signal terminals of
Usage Precautions                                                         the Timer when one of the input terminals (terminals 5, 6, and 7) and
                                                                          the common terminal (terminal 2) for the input signals are short-
Install a switch or circuit breaker that allows the operator to           circuited. Do not attempt to connect any input terminal to any
immediately turn OFF the power, and label it to clearly indicate its      terminal other than the common terminal or to apply voltage across
function.                                                                 other than the specified input and common terminals or the internal
Pay careful attention to polarity to prevent wrong connections when       circuits of the Timer may be damaged.
wiring terminals.
Internal elements may be destroyed if a voltage outside the rated         Power supply         (See note 2)               10
voltage is applied.                                                       AC or DC                                H3BA-N
Maintain voltage fluctuations in the power supply within the specified                              5, 6, 7
range.                                                                          Input contact       G, S, R              2 (see note 1)
The Timer uses a transformerless power supply. Do not touch the                                   Input terminal
input terminals while the supply voltage is being applied, otherwise
an electric shock may occur.

                                                                          Note: 1. Power supply terminal 2 is a common terminal for the input
                                                                                       signals (G, S, R) to the Timer. Never use terminal 10 as the
                                                                                       common terminal for this purpose, otherwise the internal
                                                                                       circuit of the Timer may be damaged.

                                                                                  2. Do not connect a relay or any other load between these two
                                                                                       points, otherwise the internal circuit of the Timer may be
                                                                                       damaged due to the high-tension voltage applied to the
                                                                                       input terminals.

16  Solid-state Timer H3BA-N
Operating Time Setting                                                      Mounting

When setting the operating time, do not turn the setting knob beyond       Surface Mounting
its scale range. For precise time setting, conduct operation tests by
adjusting the setting knob.                                                There is no particular restriction on surface mounting directions, but
                                                                           be sure that the Timer is securely mounted horizontally.
The accuracy of the operating time of the Analog Timer is indicated
by the percentage value on the basis of the full-scale time. The           P2CF Socket
absolute fluctuation value will not be improved by changing the time
setting. Therefore, when selecting the model, be sure that the             When mounting the Timer vertically with the P2CF Socket, consider
application will be able to use a time setting as close as the full-scale  the movable hooks and be sure that there is a 20-mm space on each
time setting of the Timer.                                                 of the upper and lower parts of the Socket.

Others                                                                                                                          Duct

When conducting a dielectric test, impulse voltage test, or insulation                                                      Hook
resistance test between the electric circuit and non-current-carrying
metal parts of the Timer mounted to a control panel, be sure to take                                                                               P2CF-08
the following steps. These steps will prevent the internal circuitry of
the Timer from damage that may be caused if a machine on the                                                                        Panel
control panel has an improper dielectric strength or insulation
resistance.

1. Separate the Timer from the circuitry of the control panel by
    disconnecting the socket from the Timer or wires.

2. Short-circuit all terminals of the Timer.
    If any device with no-contact output, such as a proximity sensor,
    photoelectric sensor, or SSR, is directly connected to the Timer,
    current leakage from the device may cause Timer malfunction. Be
    sure to test the device with the Timer before using the device for
    actual applications.

Before using the Timer to switch inductive loads, be sure to connect
a surge absorbing element to the Timer in order to prevent the Timer
from malfunction and damage. A diode is an example of a surge
absorbing element for DC circuits and a surge absorber is an
example of a surge absorbing element for AC circuits.

Do not leave the Timer in time-up condition for a month or longer in
places with high temperatures, otherwise the internal parts, such as
an electrolytic capacitor, of the Timer may be damaged. Use the
Timer with an appropriate relay so that the Timer will not be left in
time-up condition for a long time.

If the Timer is mounted in contact with a mounting surface, the
service life of internal parts may be shortened. Provide at least 10
mm between the Timer and the mounting surface to prolong the
service life of the Timer.

When the Timer is reset right after the Timer goes into time-up
condition, be sure to provide the Timer with an appropriate circuit
configuration considering the resetting time of the Timer so that a
sequential error will not result.

The Timer uses the constant value read method. Be careful when
changing the set value because the output of the Timer will be ON
when the set value coincides with the count value.

Be sure that the casing of the Timer is free from organic solvents,
such as paint thinner and benzene, strong acid, and alkali solvents,
which will damage the casing.

Note: It is impossible to connect more than two Timers in parallel.

                                                                           Solid-state Timer H3BA-N  17
PL Socket                                                                               Dismounting

1. Secure the Socket to the panel surface with screws and insert the                   Surface Mounting with P2CF
    F-shaped hook into the sockets.

2. Connect the Timer to the Socket and press the tip of each hook
    by hand.

                                                                                       Panel Mounting

                                                                                       Loosen the screws of the Flush Mounting Adapter, spread open the
                                                                                       hooks, and remove the Mounting Adapter.

Panel Mounting                                                                         When the Y92F-40, Y92F-70, Y92F-71 Mounting Adapter is used,
                                                                                       press the hook inwards with the thumb and index finger of both
When the Y92F-30 Flush Mounting Adapter is used, insert the Timer                      hands, and press the Timer towards the front side.
into the square hole from the front side of the panel and put on the
Flush Mounting Adapter from the rear side of the Timer. Press the
Flush Mounting Adapter so that the space between the Flush
Mounting Adapter and the panel is reduced as much as possible,
and secure the Flush Mounting Adapter with screws.

                                                 Panel

                                                           Screw
                                                      Y92F-30

When using the US08, be sure to use 10.5-dia. max. multi-conductor
cable or 3-dia. max. insulated stranded wire for wiring.
When the Y92F-40, Y92F-70 or Y92F-71 Flush Mounting Adapter is
used, just insert the Timer into the square panel hole. If the panel
coating is too thick and the hooks do not click, spread open the
hooks appropriately to the left and right after inserting the Timer to
the hole.

                        Spread open the hooks to the left and right.
                                                          Panel

                                                            The illustration is an ex
                                                            ample with the Y92F-70.

                       Spread open the hooks to the left and right.

18  Solid-state Timer H3BA-N
Solid-state Timer H3BA-N  19
Terms and Conditions of Sale

1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed                      ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
     part of all quotes, agreements, purchase orders, acknowledgments, price lists,              BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
     catalogs, manuals, brochures and other documents, whether electronic or in                  PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
     writing, relating to the sale of products or services (collectively, the "Products")        INTENDED USE. Omron further disclaims all warranties and responsibility of
     by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron                      any type for claims or expenses based on infringement by the Products or oth-
     objects to any terms or conditions proposed in Buyer's purchase order or other              erwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obli-
     documents which are inconsistent with, or in addition to, these Terms.                      gation hereunder shall be, at Omron's election, to (i) replace (in the form
                                                                                                 originally shipped with Buyer responsible for labor charges for removal or
2. Prices; Payment Terms. All prices stated are current, subject to change with-                 replacement thereof) the non-complying Product, (ii) repair the non-complying
     out notice by Omron. Omron reserves the right to increase or decrease prices                Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
     on any unshipped portions of outstanding orders. Payments for Products are                  the non-complying Product; provided that in no event shall Omron be responsi-
     due net 30 days unless otherwise stated in the invoice.                                     ble for warranty, repair, indemnity or any other claims or expenses regarding
                                                                                                 the Products unless Omron's analysis confirms that the Products were prop-
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices              erly handled, stored, installed and maintained and not subject to contamina-
     sent to Buyer after deducting transportation charges, taxes and duties, and will            tion, abuse, misuse or inappropriate modification. Return of any Products by
     be allowed only if (i) the invoice is paid according to Omron's payment terms               Buyer must be approved in writing by Omron before shipment. Omron Compa-
     and (ii) Buyer has no past due amounts.                                                     nies shall not be liable for the suitability or unsuitability or the results from the
                                                                                                 use of Products in combination with any electrical or electronic components,
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or                 circuits, system assemblies or any other materials or substances or environ-
     the maximum legal rate, whichever is less, on any balance not paid within the               ments. Any advice, recommendations or information given orally or in writing,
     stated terms.                                                                               are not to be construed as an amendment or addition to the above warranty.
                                                                                                 See http://www.omron247.com or contact your Omron representative for pub-
5. Orders. Omron will accept no order less than $200 net billing.                                lished information.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all               14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
                                                                                                 FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
     costs involved in, obtaining any government approvals required for the impor-               LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
     tation or sale of the Products.                                                             WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
7. Taxes. All taxes, duties and other governmental charges (other than general                   BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
     real property and income taxes), including any interest or penalties thereon,               Further, in no event shall liability of Omron Companies exceed the individual
     imposed directly or indirectly on Omron or required to be collected directly or             price of the Product on which liability is asserted.
     indirectly by Omron for the manufacture, production, sale, delivery, importa-          15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
     tion, consumption or use of the Products sold hereunder (including customs                  their employees from and against all liabilities, losses, claims, costs and
     duties and sales, excise, use, turnover and license taxes) shall be charged to              expenses (including attorney's fees and expenses) related to any claim, inves-
     and remitted by Buyer to Omron.                                                             tigation, litigation or proceeding (whether or not Omron is a party) which arises
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory              or is alleged to arise from Buyer's acts or omissions under these Terms or in
     to Omron, Omron reserves the right to stop shipments or require satisfactory                any way with respect to the Products. Without limiting the foregoing, Buyer (at
     security or payment in advance. If Buyer fails to make payment or otherwise                 its own expense) shall indemnify and hold harmless Omron and defend or set-
     comply with these Terms or any related agreement, Omron may (without liabil-                tle any action brought against such Companies to the extent based on a claim
     ity and in addition to other remedies) cancel any unshipped portion of Prod-                that any Product made to Buyer specifications infringed intellectual property
     ucts sold hereunder and stop any Products in transit until Buyer pays all                   rights of another party.
     amounts, including amounts payable hereunder, whether or not then due,                 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
     which are owing to it by Buyer. Buyer shall in any event remain liable for all              sive property of Omron Companies and Buyer shall not attempt to duplicate it
     unpaid accounts.                                                                            in any way without the written permission of Omron. Notwithstanding any
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation                     charges to Buyer for engineering or tooling, all engineering and tooling shall
     unless Buyer indemnifies Omron against all related costs or expenses.                       remain the exclusive property of Omron. All information and materials supplied
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery                by Omron to Buyer relating to the Products are confidential and proprietary,
     resulting from causes beyond its control, including earthquakes, fires, floods,             and Buyer shall limit distribution thereof to its trusted employees and strictly
     strikes or other labor disputes, shortage of labor or materials, accidents to               prevent disclosure to any third party.
     machinery, acts of sabotage, riots, delay in or lack of transportation or the          17. Export Controls. Buyer shall comply with all applicable laws, regulations and
     requirements of any government authority.                                                   licenses regarding (i) export of products or information; (iii) sale of products to
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:                   "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of
     a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship              regulated technology or information.
                                                                                            18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
        except in "break down" situations.                                                       and no course of dealing between Buyer and Omron shall operate as a waiver
     b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall          of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
                                                                                                 without Omron's written consent. (c) Law. These Terms are governed by the
        constitute delivery to Buyer;                                                            law of the jurisdiction of the home office of the Omron company from which
     c. All sales and shipments of Products shall be FOB shipping point (unless oth-             Buyer is purchasing the Products (without regard to conflict of law princi-
                                                                                                 ples). (d) Amendment. These Terms constitute the entire agreement between
        erwise stated in writing by Omron), at which point title and risk of loss shall          Buyer and Omron relating to the Products, and no provision may be changed
        pass from Omron to Buyer; provided that Omron shall retain a security inter-             or waived unless in writing signed by the parties. (e) Severability. If any provi-
        est in the Products until the full purchase price is paid;                               sion hereof is rendered ineffective or invalid, such provision shall not invalidate
     d. Delivery and shipping dates are estimates only; and                                      any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
     e. Omron will package Products as it deems proper for protection against nor-               against the amount owing in respect of this invoice. (g) Definitions. As used
        mal handling and extra charges apply to special conditions.                              herein, "including" means "including without limitation"; and "Omron Compa-
12. Claims. Any claim by Buyer against Omron for shortage or damage to the                       nies" (or similar words) mean Omron Corporation and any direct or indirect
     Products occurring before delivery to the carrier must be presented in writing              subsidiary or affiliate thereof.
     to Omron within 30 days of receipt of shipment and include the original trans-
     portation bill signed by the carrier noting that the carrier received the Products
     from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the
     Products will be free from defects in materials and workmanship for a period of
     twelve months from the date of sale by Omron (or such other period expressed
     in writing by Omron). Omron disclaims all other warranties, express or implied.
     (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
     EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1. Suitability of Use. Omron Companies shall not be responsible for conformity                   ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROP-
     with any standards, codes or regulations which apply to the combination of the              ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
     Product in the Buyer's application or use of the Product. At Buyer's request,               OVERALL EQUIPMENT OR SYSTEM.
     Omron will provide applicable third party certification documents identifying          2. Programmable Products. Omron Companies shall not be responsible for the
     ratings and limitations of use which apply to the Product. This information by              user's programming of a programmable Product, or any consequence thereof.
     itself is not sufficient for a complete determination of the suitability of the Prod-  3. Performance Data. Data presented in Omron Company websites, catalogs
     uct in combination with the end product, machine, system, or other application              and other materials is provided as a guide for the user in determining suitabil-
     or use. Buyer shall be solely responsible for determining appropriateness of                ity and does not constitute a warranty. It may represent the result of Omron's
     the particular Product with respect to Buyer's application, product or system.              test conditions, and the user must correlate it to actual application require-
     Buyer shall take application responsibility in all cases but the following is a             ments. Actual performance is subject to the Omron's Warranty and Limitations
     non-exhaustive list of applications for which particular attention must be given:           of Liability.
     (i) Outdoor use, uses involving potential chemical contamination or electrical         4. Change in Specifications. Product specifications and accessories may be
     interference, or conditions or uses not described in this document.                         changed at any time based on improvements and other reasons. It is our prac-
     (ii) Use in consumer products or any use in significant quantities.                         tice to change part numbers when published ratings or features are changed,
     (iii) Energy control systems, combustion systems, railroad systems, aviation                or when significant construction changes are made. However, some specifica-
     systems, medical equipment, amusement machines, vehicles, safety equip-                     tions of the Product may be changed without any notice. When in doubt, spe-
     ment, and installations subject to separate industry or government regulations.             cial part numbers may be assigned to fix or establish key specifications for
     (iv) Systems, machines and equipment that could present a risk to life or prop-             your application. Please consult with your Omron's representative at any time
     erty. Please know and observe all prohibitions of use applicable to this Prod-              to confirm actual specifications of purchased Product.
     uct.                                                                                   5. Errors and Omissions. Information presented by Omron Companies has been
     NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS                                  checked and is believed to be accurate; however, no responsibility is assumed
     RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT                                     for clerical, typographical or proofreading errors or omissions.
     ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
Note: This datasheet is provided as a guideline for selecting products. Do not use this document to operate the Unit.

                    ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                       To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                          OMRON ELECTRONICS LLC THE AMERICAS HEADQUARTERS
                      Schaumburg, IL USA 847.843.7900 800.556.6766 www.omron247.com

OMRON CANADA, INC. HEAD OFFICE                                      OMRON ARGENTINA SALES OFFICE
Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com  Cono Sur 54.11.4783.5300

OMRON ELETRNICA DO BRASIL LTDA HEAD OFFICE                         OMRON CHILE SALES OFFICE
So Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br            Santiago 56.9.9917.3920

OMRON ELECTRONICS MEXICO SA DE CV HEAD OFFICE                       OTHER OMRON LATIN AMERICA SALES
Apodaca, N.L. 52.811.156.99.10 001.800.556.6766 mela@omron.com  54.11.4783.5300

Cat. No. L093-E1-02A                   2009 Omron Electronics LLC
                      Specifications are subject to change without notice.
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved