电子工程世界电子工程世界电子工程世界

产品描述

搜索

Y92B-N50

器件型号:Y92B-N50
器件类别:热管理产品   
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

Heat Sinks TRK MT HEAT SINK G3N

参数
产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Omron
产品种类:
Product Category:
Heat Sinks
RoHS:YES
产品:
Product:
Heat Sinks
安装风格:
Mounting Style:
SMD/SMT
Heatsink Material:Aluminum
Fin Style:Plate
Thermal Resistance:2.8 C/W
长度:
Length:
51 mm
宽度:
Width:
47 mm
高度:
Height:
100 mm
Designed for:G3NA Series, G3NE Series
封装:
Packaging:
Bulk
商标:
Brand:
Omron Automation and Safety
产品类型:
Product Type:
Heat Sinks
工厂包装数量:
Factory Pack Quantity:
1
子类别:
Subcategory:
Heat Sinks
零件号别名:
Part # Aliases:
Y92BN50 Y92BN50NC
单位重量:
Unit Weight:
7.054792 oz

Y92B-N50器件文档内容

    G3NA Solid State Relays

                                                                                                            CSM_G3NA_DS_E_12_1

Wide Lineup of General-purpose Solid State
Relays with Applicable Loads of 5 to 90 A

• AC Output Relays with 75-A and 90-A output currents have been

added to the G3NA Series.

• All models feature the same compact dimensions to provide a

uniform mounting pitch.

• Built-in varistor effectively absorbs external surges.

(except G3NA-D210B)

• Operation indicator enables monitoring operation.

• Protective cover for greater safety.

• Standard models certified by UL and CSA and -UTU models by

TÜV.

(except G3NA-410B, G3NA-420B, and G3NA-440B(-2))

                                                                           For the most recent information on models that have been certified for

                                                                           safety standards, refer to your OMRON website.

         Refer to Safety Precautions for All Solid State

         Relays.

Model Number Structure

■ Model Number Legend

G3NA-@@@@@-@-@

    1       2  3  4  5  6  7  8

1.  Basic Model Name                                             5.  Terminal Type

    G3NA:      Solid State Relay                                     B:      Screw terminals

2.  Load Power Supply                                            6.  Zero Cross Function

    Blank:     AC output                                             Blank:  Equipped with zero cross function

    D:         DC output                                                     (AC-output models only)

3.  Rated Load Power Supply Voltage                              7.  Certification

    2:         200 VAC or 200 VDC                                    Blank:  Standard models (certified by UL and CSA)

    4:         400 VAC                                               UTU:    Certified by UL, CSA, and TÜV

4.  Rated Load Current                                           8.  RoHS Conformance

    05:        5A                                                    Blank:  Non RoHS conformance

    10:        10 A                                                          (G3NA-275B, -290B, -440B, -450B, -475B, -490B se-

    20:        20 A                                                          ries only)

    40:        40 A                                                  2:      RoHs conformance

    50:        50 A

    75:        75 A

    90:        90 A

                                                                                                                                                   1
                                                                                                                                            G3NA

Ordering Information

■ List of Models

Isolation           Zero cross  Indicator    Applicable output load  Rated input                         Model

                    function                        (See note 1.)    voltage

Phototriac Coupler  Yes         Yes          5 A at 24 to 240 VAC    5 to 24 VDC     G3NA-205B DC5-24

Photocoupler                    (Yellow)     (See note 2.)           100 to 120 VAC  G3NA-205B AC100-120

                                                                     200 to 240 VAC  G3NA-205B AC200-240

Phototriac Coupler                           10 A at 24 to 240 VAC   5 to 24 VDC     G3NA-210B DC5-24

Photocoupler                                 (See note 2.)           100 to 120 VAC  G3NA-210B AC100-120

                                                                     200 to 240 VAC  G3NA-210B AC200-240

Phototriac Coupler                           20 A at 24 to 240 VAC   5 to 24 VDC     G3NA-220B DC5-24

Photocoupler                                 (See note 2.)           100 to 120 VAC  G3NA-220B AC100-120

                                                                     200 to 240 VAC  G3NA-220B AC200-240

Phototriac Coupler                           40 A at 24 to 240 VAC   5 to 24 VDC     G3NA-240B DC5-24

Photocoupler                                 (See note 2.)           100 to 120 VAC  G3NA-240B AC100-120

                                                                     200 to 240 VAC  G3NA-240B AC200-240

Phototriac Coupler                           75 A at 24 to 240 VAC   5 to 24 VDC     G3NA-275B-UTU-2 DC5-24

Photocoupler                                 (See note 2.)           100 to 120 VAC  G3NA-275B-UTU-2 AC100-240

Phototriac Coupler                           90 A at 24 to 240 VAC   5 to 24 VDC     G3NA-290B-UTU-2 DC5-24

Photocoupler                                 (See note 2.)           100 to 240 VAC  G3NA-290B-UTU-2 AC100-240

                    Yes                      10 A at 200 to 480 VAC  5 to 24 VDC     G3NA-410B DC5-24

                                                                     100 to 240 VAC  G3NA-410B AC100-240

                                             20 A at 200 to 480 VAC  5 to 24 VDC     G3NA-420B DC5-24

                                                                     100 to 240 VAC  G3NA-420B AC100-240

                                             40 A at 200 to 480 VAC  5 to 24 VDC     G3NA-440B-2 DC5-24

                                                                     100 to 240 VAC  G3NA-440B-2 AC100-240

                                             50 A at 200 to 480 VAC  5 to 24 VDC     G3NA-450B-2 DC5-24

                                             (See note 2.)

                                             75 A at 200 to 480 VAC  5 to 24 VDC     G3NA-475B-UTU-2 DC5-24

                                             (See note 2.)           100 to 240 VAC  G3NA-475B-UTU-2 AC100-240

                                             90 A at 200 to 480 VAC  5 to 24 VDC     G3NA-490B-UTU-2 DC5-24

                                             (See note 2.)           100 to 240 VAC  G3NA-490B-UTU-2 AC100-240

                    ---                      10 A at 5 to 200 VDC    5 to 24 VDC     G3NA-D210B DC5-24

                                                                     100 to 240 VAC  G3NA-D210B AC100-240

* The standard models are certified by UL and CSA.

To order a TÜV-certified model for G3NA-205BN/210B/220B/240B/D210B, add “-UTU” to the model number.

Note: 1.  The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The applicable  load  de-

          pends on the ambient temperature.  Refer to Load Current vs. Ambient Temperature in Engineering Data on page 6.

2.        Loss time increases under 75 VAC. (Refer to page 15.) Confirm operation with the actual load.

                                                                                                                                                       2
                                                                                                               G3NA

■ Accessories (Order Separately)

One-touch Mounting Plates                                       Mounting Bracket

             Model                                              Model                    Applicable SSR

R99-12 FOR G3NA                                                 R99-11      G3NA-240B, G3NA-440B(-2)

Heat Sinks

Slim Models Enabling DIN-track Mounting                         Low-cost    Models

Model                     Applicable SSR                        Model                    Applicable SSR

Y92B-N50     G3NA-205B, G3NA-210B, G3NA-D210B,                  Y92B-A100   G3NA-205B, G3NA-210B, G3NA-D210B,

             G3NA-410B, G3NA-210T(L)                                        G3NA-220B, G3NA-410B, G3NA-420B

Y92B-N100    G3NA-220B, G3NA-420B, G3NA-220T(L)                 Y92B-A150N  G3NA-240B-2, G3NA-440B-2

Y92B-N150    G3NA-240B, G3NA-440B-2                             Y92B-A250   G3NA-440B-2

Y92B-P250    G3NA-450B-2

Y92B-P250NF  G3NA-275B-UTU-2, G3NA-290B-UTU-2,

(See note.)  G3NA-475B-UTU-2, G3NA-490B-UTU-2

Note: The Y92B-P250NF is scheduled for release on May 1, 2004.

                                                                                                                     3
                                                                                                                                G3NA

Specifications

■ Ratings

Input (at an Ambient Temperature of 25°C)

          Model       Rated voltage         Operating   Impedance                                        Voltage level

                                              voltage   (See note 1.)               Must operate voltage                     Must release voltage

G3NA-2@@B             5 to 24 VDC     4 to 32 VDC       7 mA max. (See note 2.)  4 VDC max.                        1 VDC min.

                      100 to 120 VAC  75 to 132 VAC     36 kΩ±20% (See note 4.)  75 VAC max. (See note 3.)         20 VAC min. (See note 3.)

                      200 to 240 VAC  150 to 264 VAC    72 kΩ±20%                150 VAC max. (See note 3.) 40 VAC min. (See note 3.)

                                                                                                                                (See note 5.)

G3NA-4@@B             5 to 24 VDC     4 to 32 VDC       5 mA max. (See note 2.)  4 VDC max.                        1 VDC min.

G3NA-D210B            100 to 240 VAC  75 to 264 VAC     72 kΩ±20%                75 VAC max.                       20 VAC min.

G3NA-275B-UTU-2       5 to 24 VDC     4 to 32 VDC       15 mA max.               4 VDC max.                        1 VDC min.

G3NA-290B-UTU-2       100 to 240 VAC  75 to 264 VAC     72 kΩ±20%                75 VAC max.                       20 VAC min.

G3NA-475B-UTU-2       5 to 24 VDC     4 to 32 VDC       7 mA max.                4 VDC max.                        1 VDC min.

G3NA-490B-UTU-2       100 to 240 VAC  75 to 264 VAC     72 kΩ±20%                75 VAC max.                       20 VAC min.

Note: 1.  The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,

          the input impedance is measured at 120 VAC).

2.        With constant current input circuit system. The impedance for the G3NA-2@@B-UTU is 15 mA max.

3.        Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data on page 7 for further

          details.

4.        The G3NA-240B(-UTU) is 72kΩ±20%.

5.        The G3NA-240B(-UTU) is 20 VAC min.

Output

          Model       Rated load      Load voltage      Load current (See note 1.)                   Inrush current            VDRM, VCEO

                      voltage         range             With heat sink         Without heat sink                               (reference value)

                                                        (See note 2.)

G3NA-205B             24 to 240 VAC   19 to 264 VAC     0.1 to 5 A (at 40°C)   0.1 to 3 A (at 40°C)  60 A (60 Hz, 1 cycle)     600 V (VDRM)

G3NA-210B                                               0.1 to 10 A (at 40°C)  0.1 to 4 A (at 40°C)  150 A (60 Hz, 1 cycle)

G3NA-220B                                               0.1 to 20 A (at 40°C)  0.1 to 4 A (at 40°C)  220 A (60 Hz, 1 cycle)

G3NA-240B                                               0.1 to 40 A (at 40°C)  0.1 to 6 A (at 40°C)  440 A (60 Hz, 1 cycle)

G3NA-410B             200 to 480 VAC  180 to 528 VAC    0.2 to 10 A (at 40°C)  0.2 to 4 A (at 40°C)  150 A (60 Hz, 1 cycle)    1,200 V (VDRM)

G3NA-420B                                               0.2 to 20 A (at 40°C)  0.2 to 4 A (at 40°C)  220 A (60 Hz, 1 cycle)

G3NA-440B-2                                             0.2 to 40 A (at 40°C)  0.2 to 6 A (at 40°C)  440 A (60 Hz, 1 cycle)

G3NA-D210B            5 to 200 VDC    4 to 220 VDC      0.1 to 10 A (at 40°C)  0.1 to 4 A (at 40°C)  20 A (10 ms)              400 V (VCEO)

G3NA-275B-UTU-2       24 to 240 VAC   19 to 264 VAC     1 to 75 A (at 40°C)    1 to 7 A (at 40°C)    800 A (60 Hz, 1 cycle)    600 V (VDRM)

G3NA-290B-UTU-2                                         1 to 90 A (at 40°C)    1 to 7 A (at 40°C)    1,000 A (60 Hz, 1 cycle)

G3NA-475B-UTU-2       200 to 480 VAC  180 to 528 VAC    1 to 75 A (at 40°C)    1 to 7 A (at 40°C)    800 A (60 Hz, 1 cycle)    1,200 V (VDRM)

G3NA-490B-UTU-2                                         1 to 90 A (at 40°C)    1 to 7 A (at 40°C)    1,000 A (60 Hz, 1 cycle)

Note: 1.  The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data

          on page 6.

2.        When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.

                                                                                                                                                   4
                                                                                                                                      G3NA

■ Characteristics

Item          G3NA-       G3NA-  G3NA-       G3NA-  G3NA-  G3NA-           G3NA-   G3NA-   G3NA-       G3NA-     G3NA-   G3NA-        G3NA-

              205B        210B   220B        240B   410B   420B            440B-2  450B-2  D210B       275B-     290B-   475B-        490B-

                                                                                                       UTU-2     UTU-2   UTU-2        UTU-2

Operate time  1/2 of load power source cycle + 1 ms max. (DC input)                        1 ms        1/2 of load power source cycle + 1 ms

              3/2 of load power source cycle + 1 ms max. (AC input)                        max. (DC    max. (DC input)

                                                                                           input)      3/2 of load power source cycle + 1 ms

                                                                                           30 ms       max. (AC input)

                                                                                           max. (AC

                                                                                           input)

Release time  1/2 of load power source cycle + 1 ms max. (DC input)                        5 ms        1/2 of load power source cycle + 1 ms

              3/2 of load power source cycle + 1 ms max. (AC input)                        max. (DC    max. (DC input)

                                                                                           input)      3/2 of load power source cycle + 1 ms

                                                                                           30 ms       max. (AC input)

                                                                                           max. (AC

                                                                                           input)

Output ON     1.6 V (RMS) max.                      1.8 V (RMS) max.                       1.5 V       1.6 V (RMS) max.  1.8 V (RMS) max.

voltage drop                                                                               max.

Leakage       5 mA max. (at 100 VAC)                10 mA max. (at 200 VAC)                5 mA        5 mA max. (at     10 mA max. (at

current       10 mA max. (at 200 VAC)               20 mA max. (at 400 VAC)                max.        100 VAC)          200 VAC)

                                                                                           (at 200     10 mA max. (at    20 mA max. (at

                                                                                           VDC)        200 VAC)          400 VAC)

Insulation    100 MΩ min. (at 500 VDC)

resistance

Dielectric    2,500 VAC, 50/60 Hz for 1 min                                                            4,000 VAC, 50/60 Hz for 1 min

strength

Vibration     Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm     double  amplitude)

resistance

Shock         Destruction: 1,000 m/s2

resistance

Ambient       Operating:    –30°C to 80°C (with no icing or condensation)

temperature   Storage:      –30°C to 100°C (with no icing or condensation)

Ambient       Operating: 45% to 85%

humidity

Weight        Approx. 60 g              Approx.     Approx. 80 g                           Approx.     Approx. 120 g

                                        70 g                                               70 g

                                                                                                                                              5
                                                                                                                                                                                                                 G3NA

Engineering Data

Load Current vs. Ambient Temperature

G3NA-205B                                                                                G3NA-210B/410B                                                       G3NA-220B/420B

                                                                                     20

                                                                                     16

(A)                   With standard heat sink                      (A)               10                                                                       (A)

current               (Y92B-A100 or                                current                   With standard heat sink                                          current     With standard heat sink

                      Y92B-N50) or aluminum                                                  (Y92B-A100 or                                                                (Y92B-A100 or

                      plate measuring 75 mm                                                  Y92B-N50) or aluminum                                                        Y92B-N100) or aluminum

                      x 75 mm x t3.2 mm                                                   8  plate measuring 150 mm                                                       plate measuring 200 mm

                      (W x H x t)                                                            x 150 mm x t3.2 mm                                                           x 200 mm x t3.2 mm

Load                  Without heat sink                            Load                   6  (W x H x t)                                                      Load        (W x H x t)

                                                                                          5  With iron plate measuring                                                    With iron plate measuring

                                                                                          4  100 x 100 x t0.8 (W x H x t)                                                 100 x 100 x t0.8 (W x H x t)

                                                                                             Without heat sink

                                                                                          2

                                                                                                                                                                                Without heat sink

                                                                                          0

                           Ambient temperature              (°C)                              Ambient temperature                (°C)                                                  Ambient temperature (°C)

                  G3NA-240B                                                          G3NA-440B-2                                                                       G3NA-450B-2

                  50                                                                 50                                                                       60

                  45                                                                 45                               With Y92B-A250

                                                                                                                      or heat sink with a                     50

                  40                                                                 40                               radiation efficiency                                With standard  heat  sink

                      With standard heat                                                                              of 1°C/W.                                           (Y92B-P250)

Load current (A)      sink (Y92B-A150N or                          Load current (A)                                                         Load current (A)  40

                  30  Y92B-N150)                                                     30      With standard heat

                                                                                             sink (Y92B-A150N

                                                                                             or Y92B-N150)                                                    30

                  20                                                                 20

                                                                                                                                                              20

                      With iron plate measuring                                              With iron plate measuring

                  12  100 x 100 x t0.8 (W x H x t)                                   12      100 x 100 x t0.8 (W x H x t)
                                                                                     10
                  10  Without heat sink                                                      Without heat sink                                                10
                                                                                                                                                                          Without heat sink
                  6                                                                  6                                                                                 6

                  4                                                                  4
                                                                                     2
                  2                                                                  −030−20                                                                           0
                  −030−20
                           0       20      40       60  80    100                             0           20    40         60    80   100                              −30 −20  0        20        40  60  80    100

                           Ambient temperature          (°C)                                 Ambient temperature               (°C)                                             Ambient temperature (°C)

                  G3NA-275B-UTU-2                                                    G3NA-290B-UTU-2

                  G3NA-475B-UTU-2                                                    G3NA-490B-UTU-2                                        G3NA-D210B

                  80                                                                 100                                                                      20

                  75                                                                 90

                  70  0.6°C/W with

                      Heat Sink                                                      80      0.3°C/W with                                                     10

                  60                                                                         Heat Sink

Load current (A)                                                   Load current (A)  70                                                     Load current (A)              With standard heat sink

                                                                                                                                                                          (Y92B-A100 or Y92B-N50)

                  50                                                                 60                                                                                   or aluminum plate measuring

                                                                                                                                                                          150 mm x 150 mm x t3.2 mm

                  40       Using the Y92B-P250NF                                     50                                                                                   (W x H x t)

                                                                                              Using the Y92B-P250NF                                           6

                                                                                     40                                                                       5        With iron plate measuring

                  30                                                                 35                                                                       4        100 x 100 x t0.8 (W x H x t)

                                                                                     30                                                                                   Without heat sink

                  20  With iron plate measuring                                              With iron plate measuring

                  12  100 x 100 x t0.8 (W x H x t)                                   20      100 x 100 x t0.8 (W x H x t)                                     2

                  10                                                                 12
                  7
                           Without heat sink                4A                       7                                               4A
                  20                                                                 20       Without heat sink
                                                                                                                                                              −030 −20          0        20    40      60  80    100
                  −30 −20  0        20        40    60 70 80  100                    −30 −20  0           20     40        60 70 80   100

                              Ambient temperature (°C)                                           Ambient temperature (°C)                                                       Ambient temperature        (°C)

Note: The ambient operating temperature of the Y92B-P250NF is

                      −30 to 70°C. Be sure the operating temperature is within this range.

                                                                                                                                                                                                                       6
                                                                                                                                                                                                                                                                                                                                  G3NA

One Cycle Surge Current

The values shown by the solid line are for non-repetitive inrush currents.

Keep the inrush current below the values shown by the dotted line if it occurs repetitively.

                                                                                                                         G3NA-210B                                                                                      G3NA-220B                                                                      G3NA-240B

                              G3NA-205B                                                                                  G3NA-410B                                                                                      G3NA-420B                                                                      G3NA-440B-2/-450B-2

Inrush current (A peak)  60                                                                Inrush current (A peak)  150                                                                   Inrush current (A peak)                                                        Inrush current (A peak)

                                                                                                                                                                                                                   200                                                                            400

                         40                                                                                         100                                                                                            150                                                                            300

                                                                                                                                                                                                                   100                                                                            200

                         20                                                                                         50

                                                                                                                                                                                                                   50                                                                             100

                         0                                                                                          0                                                                                              010                                                                            0

                              10      30   50     100  200  500      1,000          5,000                                10        30  50     100    200      500  1,000       5,000                                           30  50  100  200  500  1,000       5,000                                10  30  50  100  200  500  1,000  5,000

                                                            Energized time (ms)                                                                               Energized time (ms)                                                                Energized time (ms)                                                         Energized time (ms)

                                                                                                                         G3NA-275B-UTU-2                                                                                G3NA-290B-UTU-2

                              G3NA-D210B                                                                                 G3NA-475B-UTU-2                                                                                G3NA-490B-UTU-2

peak)                    30                                                                peak)                    900                                                                   peak)                    1,200

                         28

                         26                                                                                         800

(A                       24                                                                (A                                                                                             (A                       1,000

current                                                                                    current                  700                                                                   current

                         22

                         20                                                                                         600                                                                                            800

Inrush                   18                                                                Inrush                                                                                         Inrush

                         16                                                                                         500

                         14                                                                                                                                                                                        600

                                                                                                                    400

                         12

                         10                                                                                         300                                                                                            400

                         8

                         6                                                                                          200

                         4                                                                                                                                                                                         200

                                                                                                                    100

                         2

                         010                                                                                             0                                                                                              0

                                  20  30   50 70 100   200  300 500      1,000      2,000                                   10         30        50       100             300      1,000                                   10      30  50        100         300  1,000

                                                            Energized time (ms)                                                                               Energized time (ms)                                                                Energized time (ms)

Temperature

Characteristics

(for Must Operate

Voltage and Must                                                                           Heat Sink Area

Release Voltage)                                                                           vs. Load Current

                              G3NA-2@@B AC input                                                                                G3NA-220B

Variation rate (%)       40                                                                Heat sink area (cm2)     3,000

                                                                                                                    2,000       Ambient                        Ambient

                                                                                                                                temperature 80°C               temperature 40°C

                         20                                                                                         1,000

                                                                                                                    700

                                                                                                                    500                                                                                            Note: The heat sink area refers to the combined area

                                                                                                                    300                                                                                                            of the sides of the heat sink that radiate heat.

                         0                                                                                          200

                                                                                                                                                               Aluminum plate                                                      For example, when a current of 18 A is allowed

                                                                                                                    100                                        3.2 mm thick                                                        to flow through the SSR at 40°C, the graph

                         −20                                                                                             70                                                                                                        shows that the heat sink area is about 450 cm2.

                                                                                                                         50

                                                                                                                         30                                                                                                        Therefore, if the heat sink is square, one side of

                         −40                                                                                             20                                                                                                        the heat sink must be 15 cm (                                           450 (cm2)/2 ) or

                         −30          −20      0       20   40       60         80  100                                                                                                                                            longer.

                                                       Ambient temperature (°C)                                             0   2  4       6  8      10   12  14   16  18  20  22  24

                                                                                                                                                                   Load current (A)

Thermal Resistance Rth (Back of                                                                                                                                                                                    Thermal Resistance Rth of Heat Sinks

Junction SSR) (Examples)                                                                                                                                                                                           (Examples)

                                                  Model                                                                                Rth (°C/W)                                                                                           Model                                                                  Rth (°C/W)

G3NA-205B                                                                                                                                     3.22                                                                      Y92B-N50                                                                                        2.8

G3NA-210B                                                                                                                                     2.62                                                                      Y92B-N100                                                                                       1.63

G3NA-220B                                                                                                                                     1.99                                                                      Y92B-N150                                                                                       1.38

G3NA-240B                                                                                                                                     0.45                                                                      Y92B-A100                                                                                       1.63

G3NA-275B-UTU-2                                                                                                                               0.45                                                                      Y92B-A150N                                                                                      1.37

G3NA-475B-UTU-2                                                                                                                                                                                                         Y92B-A250                                                                                       1.00

G3NA-290B-UTU-2

G3NA-490B-UTU-2                                                                                                                                                                                                         Y92B-P250NF                                                                                     0.46

G3NA-D210B                                                                                                                                    2.62                                                                 Note: When using a commercially available heat sink, use one with a

                                                                                                                                                                                                                                   thermal resistance equal to or less that the OMRON Heat Sink.

                                                                                                                                                                                                                                                                                                                                                  7
                                                                                                                                           G3NA

Dimensions

■ Relays

Note: All units are in millimeters unless otherwise indicated.

G3NA-D210B, G3NA-205B, G3NA-210B, G3NA-220B

                                                 11.9              Four, M4 x 8

                                                         4.5 dia.  screws

                         58 max. 47.5 44

                                                                     Operating          15.8

                                                         4.5         indicator          25 max.

                                                         25                             27 max.

                                                 43 max.

                             Note:  The load can be connected to either the positive or negative side.

G3NA-240B,  G3NA-275B-UTU-2, G3NA-290B-UTU-2, G3NA-440B-2, G3NA-475B-UTU-2,                                          G3NA-490B-UTU-2

                                                 11.9    4.5 dia.

                                                                     Two, M5 x 12 screws

                             58  min. 47.5  44

                                                                     Operating

                                                                     indicator          18.9

                                                         4.5                            28 max.

                                                         25          Two,               30 max.

                                                 43 max.             M4x8

G3NA-410B,  G3NA-420B

                                                 11.9              Four, M4 x 8

                                                        4.5 dia.   screws

                         58  max.   47.5  44

                                                                   Operating            18.9

                                                         4.5       indicator            28 max.

                                                         25                             30 max.

                                                 43 max.

Mounting Holes                                         Terminal Arrangement/ Internal Connections

(Same for all models.)                                                           (Top View)

                                                 DC load                                                    AC load

                                            (G3NA-D210B(-UTU) only)                     (All     models except those given on the  left.)

          Two, 4.3-dia.                          Load   (See Note.)                                   Load

          or M4 holes                                                Load                                            Load

                                                                     power                                           power

                                                 Output              supply                           Output         supply

                                            1            2                                       1            2

47.6±0.2                                    −            +

                                            (−)          (+)                                     (−)          (+)

                                            4            3                                       4            3

                                                 Input                                                Input

                                          Note: When connecting the load, either the

                                                 positive or negative side of the load

                                                 terminals can be connected.

                                                                                                                                                 8
                                                                                                                              G3NA

■ Options (Order Separately)                                                    To mount the Relay to DIN

One-touch Mounting Plate                                                        Track, first mount it to the

                                                                                One-touch Mounting Plate

The One-touch Mounting Plate is used to mount the GN3A              to  a  DIN  and then attach it to the DIN

Track.                                                                          Track as shown in the

                                                                                diagram.

R99-12 FOR G3NA (for the G3NA and G3NE)

                                              Four, M4 mounting

                                              holes for the G3NA

                                   44                 13.5

                                   30                 1.6

                                                                                To remove the Relay from

                                                                                the DIN Track, pull down on

                                                                                the tab with a screwdriver in

            81  47.5  35                                                        the direction of the arrow.

                                                Two, M3 mounting

                                                holes for the G3NE

                                                                                •  When a Relay is mounted to DIN Track, use  it within the rating  for  a

                                                                                   Relay without a heat sink.

                                                                                •  Use the following DIN Tracks: PFP-100N or  PFP-100N2.

Mounting Bracket

R99-11 (for the G3NA-240B, G3NA-440B-2)

Use Mounting Bracket R99-11 so that the G3NA-240B/-440B can be

mounted with the same pitch as that of the G3N-240B.

                          16

                            8

                12.5                   5

            21                                                                                         56

                                    4                 4.6

Heat Sinks

Y92B-N50 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-210T(L))

For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs).

For mounting method, refer to "Precautions for Correct Use".

                                          35                                    Mounting Holes

                                          30.5                                  Two, 4.4-dia.

                                          ±0.3                                  or M4 holes

                                                      4.6 dia.

                100       77
                max.      max.

                      90      47.6                                                      90±0.4

                      ±0.3                            Two, M3 holes

                                                      Two, M4 holes

                               5.6                                              35±0.2

                                                                                Weight: approx. 200 g

                                       44
                                       max.

                                5         30

                                                      Two, 3.2-dia. holes

                          5m1ax.6

                               4.5     47
                                       max.

                                                                                                                                                            9
                                                                                                                                                    G3NA

Y92B-N100 Heat Sink (for the G3NA-220B, G3NA-420B, G3NE-220T(L))

For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient                 Temperature       graphs).

For mounting method, refer to "Precautions for Correct Use".

                     35                                                                     Mounting Holes

                     30.5                                                                          Two, 4.4-dia.

                     ±0.3                                                                          or M4 holes

                                                              4.6 dia.

100      77
max.     max.

90            47.6                                                                                       90±0.4

±0.3                                                          Two, M3 holes

                                                              Two, M4 holes

              5.6                                                                               35±0.2

                     71 max.                                                           Weight: approx. 400 g

                     30

              28                                              Two, 3.2-dia. holes

         100
         max.

               5

              13

              4.5    75 max.

Y92B-N150 Heat Sink (for the G3NA-240B, G3NA-440B-2)

For surface mounting, a 30% derating of the load current is required (from             the  Load Current vs. Ambient    Temperature       graphs).

For mounting method, refer to "Precautions for Correct Use".

                                                                                            Mounting Holes

                           35                                                                            Two, 4.4-dia.

                                                                    4.6 dia.                             or M4 holes

100      77

max.     max.                                                           47.6

     90       56

     ±0.3     ±0.3

                                                                    Three,

              5.6                                                   M4 holes

                     100 max.                                                               Weight: approx. 560 g

                           30

              28                                                        Two, 3.2-dia. holes

         100

         max.

               5

              13

              4.5    104 max.

Y92B-P250NF Heat Sink (for the G3NA-275B-UTU(-2), G3NA-475B-UTU(-2), G3NA-290B-UTU(-2), G3NA-490B-UTU(-2))

For mounting method, refer to "Precautions for Correct Use".                                                                                        Mounting Holes

                                                                                            Fan power supply, 200 VAC  50/60 Hz

                                                              172 max.                                                 133.4                        64±0.3

                                                              166 max.                                                 120 max.

                                                              120                                                       105

                                                                                            M4                                            130±0.3

80 max. 64                                                                                      110max.

Two, 4.6-dia. holes

                                                              47.6      Two, M4 holes  Thermostat                                                   Two, 4.5-dia. or

                                                                                       NC contact, 90°C           Weight: approx. 2.5 kg            M4 holes

                                                                                                                                                                      10
                                                                                                                                            G3NA

Y92B-P250

                              Two, M4        Four, M4                                     Mounting Holes

                              Depth 10                                                                  Four, 4.5 dia. or M4

                                 47.6                        190.5 max.

        Four, R2.5

                                 130.5 max.

                                                       70 max.

Y92B-A100 Heat Sink

(for the G3NA-205B,

G3NA-210B,

G3NA-220B,                               Y92B-A150N Heat Sink                    Y92B-A250 Heat Sink

G3NA-410B,                               (for the G3NA-240B,                     (for the G3NA-440B-2)

G3NA-420B,                               G3NA-440B-2)

G3NA-D210B)                      Three, M4 holes                         Three, M4 holes

        Two, M4 holes            90±0.1                                  90±0.1                                               80.5 max.102  max.

90±0.1                                       R2.2      47.6                      R2.2     47.6                                1.5

                                                                                                                                  9.6

                                                                                                                                  2

           47.6                                        50±0.1                             50±0.1           30                 1.5

        50±0.1                                         56±0.5                             56±0.5           45.5 max.

        100 max.                                       150 max.                           250 max.

        Weight: approx. 210   g              Weight: approx.     310  g          Weight: approx. 510    g

        Mounting Holes

        Y92B-A100

        Y92B-A150

        Y92B-A250

                       Four,  4.3-dia.   or  M4 holes

For surface mounting, a 30% derating of the load current is required     (from the Load Current vs. Ambient Temperature graphs).

For mounting method, refer to "Precautions for Correct Use".

                                                                                                                                                  11
                                                                                                                                             G3NA

Safety Precautions

Refer to Safety Precautions for All Solid State Relays.

                          !CAUTION                                          3.  Wire the G3NA and tighten screws correctly, observing the

                                                                                following precautions

Touching the charged section may occasionally cause                             Heat generated by a terminal error may occasionally result in fire

minor electric shock. Do not touch the G3NA terminal                            damage. Do not operate if the screws on the output terminal are

section (the charged section) when the power supply                             loose.

is ON. Be sure to attach the cover before use.                                  • Abnormal heat generated by wires may occasionally result in

                                                                                   fire damage. Use wires suitable for the load current.

                          !CAUTION                                              • Abnormal heat generated by terminals may occasionally result

The G3NA and heat sink will be hot and may                                         in fire damage. Do not operate if the screws on the output

occasionally cause minor burns. Do not touch the                                   terminal are loose.

G3NA or the heat sink either while the power supply is                             Tightening Torque

ON, or immediately after the power is turned OFF.

                                                                                   Screw size  Tightening torque

                          !CAUTION                                                 M4          1.2 N⋅m

The internal snubber circuit is charged and may                                    M5          2.0 N⋅m

occasionally cause minor electric shock. Do not touch                           •  Abnormal heat generated by terminals may occasionally result

the G3NA’s main circuit terminals immediately after                                in fire damage. When tightening terminal screws, be sure that

the power is turned OFF.                                                           no non-conductive foreign matter is caught in screw.

                                                                                •  For GN3A Relays of 40 A or higher, use crimp terminals of an

                                                                                   appropriate size for the wire diameter for M5 terminals.

                          !CAUTION                                              •  Do not use any wires with damaged sheaths. These may cause

Be sure to conduct wiring with the power supply turned                             electric shock or leakage.

OFF, and always attach the terminal cover after                                 •  Do not place wiring in the same conduit or duct as high-voltage

completing wiring. Touching the terminals when they                                lines. Induction may cause malfunction or damage.

are charged may occasionally result in minor electric                           •  Use wires of an appropriate length, otherwise malfunction and

shock.                                                                             damage may result due to induction.

                          !CAUTION                                              •  Mount the DIN Track securely. Otherwise, the DIN Track may

Do not apply a short-circuit to the load side of the                               fall.

G3NA. The G3NA may rupture. To protect against                                  • Be sure that the G3NA clicks into place when mounting it to DIN

short-circuit accidents, install a protective device, such                         Track. The G3NA may fall if it is not mounted correctly.

as a quick-burning fuse, on the power supply line.                              • Do not mount the G3NA when your hands are oily or dirty, e.g.,

                                                                                   with metal powder. These may cause G3NA failure.

■ Precautions for Safe Use                                                      • Tighten the G3NA screws securely.

                                                                                   Tightening torque: 0.78 to 0.98 N⋅m

Although OMRON continuously strives to improve the quality and                  • Tighten the heat sink screws securely.

reliability of our relays, the G3NA contains semiconductors, which                 Tightening torque: 0.98 to 1.47 N⋅m

are generally prone to occasional malfunction and failure.                  4.  Preventing Overheating

Maintaining safety is particularly difficult if a relay is used outside of      When using the High-capacity Heat Sink (Y92B-P250NF), always

its ratings. Always use the G3NA within the rated values. When using            use a thermostat or other method to protect from overheating in

the G3NA, always design the system to ensure safety and prevent                 the event that the fan stops.

human accidents, fires, and social damage even in the event of              5.  Do Not Touch Fan Blades

G3NA failure, including system redundancy, measures to prevent                  When the fan is operating, do not touch the fan blades with any

fires from spreading, and designs to prevent malfunction.                       part of your body or allow foreign matter to come into contact with

1.  G3NA malfunction or fire damage may occasionally occur. Do not              the blades. Always attach the enclosed finger guard when using

    apply excessive voltage or current to the G3NA terminals.                   the G3NA.

2.  Heat Dissipation                                                        6.  Operating Conditions

    • Do not obstruct the airflow to the G3NA or heat sink. Heat                • Only use the G3NA with loads that are within the rated values.

    generated from an G3NA error may occasionally cause the                        Using the G3NA with loads outside the rated values may result

    output element to short, or cause fire damage.                                 in malfunction, damage, or burning.

    • Be sure to prevent the ambient temperature from rising due to             • Use a power supply within the rated frequency range. Using a

    the heat radiation of the G3NA. If the G3NA is mounted inside a                power supply outside the rated frequency range may result in

    panel, install a fan so that the interior of the panel is fully                malfunction, damage, or burning.

    ventilated.                                                             7.  Do not transport the G3NA under the following conditions. Failure

    • Mount the G3NA in the specified orientation. If the G3NA is               or malfunction may occur.

    mounted in any other orientation, abnormal heat generation                  • Conditions under which the G3NA will be exposed to water

    may cause output elements to short or may cause burning.                    • High temperatures or high humidity

    • Do not use the G3NA if the heat sink fins are bent, e.g., as the          • Without proper packing

    result of dropping the G3NA. Heat dissipation characteristics will

    be reduced, possibly causing G3NA failure.

    • Apply a thin layer of Momentive Performance Materials’s

    YG6260 or Shin-Etsu Chemical’s G747, or a similar product to

    the heat sink before mounting

    • If a material with high thermal resistance, such as wood, is

    used, heat generated by the G3NA may occasionally cause fire

    or burning. When installing the G3NA directly into a control

    panel so that the panel can be used as a heat sink, use a panel

    material with low thermal resistance, such as aluminum or steel.

    • Use the specified heat sink or one with equivalent or better

    characteristics.

                                                                                                                                                     12
                                                                                                                                                                                           G3NA

Operating and Storage Locations                                             Relationship between SSRs and Duct Height

Do not use or store the G3NA in the following locations. Doing so           Incorrect Example                          Countermeasure 1                          Countermeasure 2

may result in damage, malfunction, or deterioration of performance                                                                             50 mm max.

characteristics.                                                                                            Duct                               (A height of no                                 Duct

                                                                                                                                               more than half

•   Do not use or store in locations subject to direct sunlight.                                                                               the SSR's height

                                                                                                                                               is recommended.)

•   Do not use in locations subject to ambient temperatures outside            Mounting surface                        Mounting surface                          Mounting surface        Airflow

    the range –20 to 60°C.

•   Do not use in locations subject to relative humidity outside the

    range 45% to 85% or locations subject to condensation as the                                            Vertical                                                               Base

    result of severe changes in temperature.                                                                direction

•   Do not store in locations subject to ambient temperatures outside

    the range –30 to 70°C.                                                                                  Duct                               Duct                                            Duct

•   Do not use or store in locations subject to corrosive or flammable

    gases.

•   Do not use or store in locations subject to dust (especially iron

    dust) or salts.                                                         Do not surround the SSR                    Use short ducts.                          If the ducts cannot be

•   Do not use or store in locations subject to shock or vibration.         with ducts, otherwise the                                                            shortened, place the SSR on

                                                                            heat radiation of the SSR                                                            a metal base so that it is not

•   Do not use or store in locations subject to exposure to water, oil, or  will be adversely affected.                                                          surrounded by the ducts.

    chemicals.                                                              Ventilation Outside the Control Panel

•   Do not use or store in locations subject to high temperatures or

    high humidity.                                                                                                                       Be aware of airflow

•   Do not use or store in locations subject to salt damage.

•   Do not use or store in locations subject to rain or water drops.                                                  Duct

■ Precautions for Correct Use                                                                                                                                                      Ventilation

                                                                                                                                                                                   outlet

                                                                                                                                                                                   (axial fan)

Please observe the following precautions to prevent failure to

operate, malfunction, or undesirable effect on product performance.

Before Actual Operation

1.  The G3NA in operation may cause an unexpected accident.

    Therefore it is necessary to test the G3NA under the variety of                              Air inlet

    conditions that are possible. As for the characteristics of the

    G3NA, it is necessary to consider differences in characteristics

    between individual SSRs.                                                If the air inlet or air outlet has a filter, clean the filter regularly to

2.  Unless otherwise specified, the ratings in this catalog are tested      prevent it from clogging to ensure an efficient flow of air.

    values in a temperature range between 15°C and 30°C, a relative         Do not locate any objects around the air inlet or air outlet, otherwise

    humidity range between 25% and 85%, and an atmospheric                  the objects may obstruct the proper ventilation of the control panel.

    pressure range between 88 and 106 kPa (standard test                    A heat exchanger, if used, should be located in front of the SSRs to

    conditions according to JIS C5442). It will be necessary to             ensure the efficiency of the heat exchanger.

    provide the above conditions as well as the load conditions if the

    user wants to confirm the ratings of specific G3NAs.                    •  Please reduce the ambient temperature of SSRs.

Mounting Method                                                                The rated load current of an SSR is measured at an ambient

                                                                               temperature of 40°C.

Note: The same method in case not use heatsink.                             •  An SSR uses a semiconductor in the output element. This causes

                                                                               the temperature inside the control panel to increase due to heating

SSR Mounting Pitch (Panel Mounting)                                            resulting from the passage of electrical current through the load. To

The correct mounting direction is vertical as below figure.                    restrict heating, attach a fan to the ventilation outlet or air inlet of

                                                                               the control panel to ventilate the panel. This will reduce the ambient

            Duct                                                               temperature of the SSRs and thus increase reliability. (Generally,

                                                                               each 10 °C reduction in temperature will double the expected life.)

                                                                               Load current (A)                       5A                 10 A  20 A              40 A                    75 A     90 A

                                              60 mm min.                    Required number                 0.08                         0.16  0.31              0.62              1.2            1.44

                                                                            of fans per SSR

                                                                            Example: For 10 SSRs with load currents of 10 A,

                                                                                                 0.16 x 10 = 1.6

                                              Vertical direction                                 Thus, 2 fans would be required.

                                                                            Size of fans: 92 mm2, Air volume: 0.7 m3/min,

                                              30 mm min.                    Ambient temperature of control panel: 30 °C

            80 mm min.                                                      If there are other instruments that generate heat in the control panel

                                                                            other than SSRs, additional ventilation will be required.

                                                                                                                                                                                                        13
                                                                                                                                          G3NA

High-capacity Heat Sink (Y92B-                                         Ratings and Characteristics of High-

P250NF)                                                                capacity Heat Sink (Y92B-P250NF)

DIN-track Mounting                                                     Fan Ratings

• Assembled DIN Tracks are heavy. Mount the DIN Tracks securely.       Rated voltage          200 V

Be sure that the Heat Sink is securely locked to the DIN Track.        Operating voltage      85% to 110% of rated voltage

• Attach End Plates (PFP-M, order separately) to both ends of the      Frequency              50/60 Hz

Units on the DIN Track to hold them in place.

• To mount a Heat Sink to a DIN Track, press down at the point         Rated current          0.061 A at 50 Hz

indicated by arrow 1 in the diagram and then press in the Heat Sink    (See note.)            0.052 A at 60 Hz

at the point indicated by arrow 2.                                     Rated speed            2,600 r/min at 50 Hz

                                                                       (See note.)            3,050 r/min at 60 Hz

                                                                       Note: Average values.

                                                                       Thermostat Ratings

                                                                       Operating temperature          Approx. 90°C

              Vertical                                                 Contact ratings                8 A at 250 VAC, resistive load

                                                                                                      5 A at 30 VDC, resistive load

                                                                       Fan Characteristics

                                                                       Motor type             Single-phase shading coil induction motor

                                                                                              (2-pole, open type)

Applicable DIN Track                                                   Terminal type          Terminals

Mounting is possible on TE35-15Fe (IEC 60715) DIN tracks. DIN          Insulation class       IEC class B (130°C)

tracks from the following manufacturers can be used.                                          UL class A (105°C)

                                                                                              CSA class A (105°C)

Manufacturer  Thickness: 1.5 mm                Thickness: 2.3 mm       Insulation             100 MΩ min. (at 500 VDC) between all power

Schneider     AM1-DE2000             ---                               resistance             supply connections and uncharged metal parts.

WAGO          210-114 or 210-197     210-118                           Insulation             2,000 VAC (1 minute) between all power supply

PHOENIX       N35/15                 N35/15/15-2.3                     withstand voltage      connections and uncharged metal parts.

                                                                       Ambient operating      −30 to 70°C (no icing)

Direct Mounting                                                        temperature

• Prepare mounting holes as shown in the diagram.                      Ambient storage        −40 to 85°C (no icing)

Tightening torque: 0.98 to 1.47 N⋅m                                    temperature

                                                                       Ambient humidity       25 to 85%

                          64±0.3                                       Protection             Impedance protection

                                                                       Materials              Frame : Die-cast aluminum

                                                                                              Blades : Glass polycarbonate

              130±0.3                                                  Bearings               Ball bearings

                                                                       Weight                 Approx. 300 g

                                                                       Compliant standards    PSE, EN/IEC 60335 (CE marking compliant)

                                                                       Certified standards    UL/CSA (pending)

                          Four, 4.5 dia. or M4 holes                   •  Use a commercial power supply (50/60 Hz) for the Fan.

• When mounting a Heat Sink directly, first remove the Fan Unit, then  •  Be sure to turn OFF the power supply and wait for the blades to

mount the Heat Sink by itself before attaching the Fan Unit again.        stop before inspecting the Fan.

(Remove the two screws shown in the following diagram.)                •  High-precision ball bearings are used in the fan and these may be

           Remove screws                                                  damaged if the Fan is dropped or otherwise subjected to shock.

                          Fan Unit                                        The life and characteristics of the Fan will be reduced if the

                                                                          bearings are damaged. Do not subject the Fan to shock.

                                                                       •  The life of the Fan depends on the ambient temperature, As a

                                                                          guideline, the Fan life is 40,000 hours for continuous usage at

                                                                          40°C.

                                                                       •  Be sure there are no objects near the air vents that would restrict

                                                                          air flow and no loose objects, such as electrical lines.

              Heat Sink                                                •  The Fan is an OMRON R87F-A4A-93HP (200 VAC) Fan. Use the

• First, temporarily mount the Heat Sink with the bottom two screws       same model of Fan for replacement.

and then attach the top two screws with the mounting bracket           •  The recommended tightening torque for the Fan is 0.44 N⋅m.

sandwiched between the Heat Sink and mounting surface. Finally,        •  Terminals equivalent to Faston #110 are used for the Fan power

tighten all four screws.                                                  supply terminals.

                                                                       •  Refer to the following table for the OMRON Fan power supply plug

                                                                          cables (order separately).

                                                                          Cable     UL certified      Complies with Electrical Appliance

                                                                          length                      and Material Safety Law (Japan)

                                                                       1m          R87F-PC            R87F-PCJT

                                                                       2m          R87F-PC-20         R87F-PCJT-20

                                                                       • Connect the ground screw hole on the fan to PE.

                                                                                                                                                14
                                                                                                                                                        G3NA

Preventing Overheating with a High-                                                     2.  DC-switching models

capacity Heat Sink (Y92B-P250NF)                                                               Less than 3 m

                                                                                                                                 Load

•  When the High-capacity Heat Sink is used, high-capacity switching                                    Input  G3NA-UTU  Output

   at 75 A or 90 A requires forced cooling with a fan. Connect the Fan

   to a power supply according to its ratings specifications.                           • The input cable must be less than 3 m.

•  If the Fan stops due to a power supply error, due to foreign matter

   in the power supply connection, or due to aging, the Heat Sink will                  Loss Time

   heat to high temperatures, possibly resulting in failure of the SSR or

   adverse affects on other devices. Implement an overheating                           The loss time will increase when the G3NA is used at a low applied

   prevention measure, such as turning OFF the load current, if the                     voltage or current. Be sure that this does not cause any problems.

   Heat Sink overheats.

•  A thermostat is provided to detect overheating. The thermostat

   uses a NC contact, i.e., the circuit will be opened for overheating.

   This thermostat can be used to stop the operation of the SSR.

   Implement an overheating prevention measure by using this signal

   to output an alarm or perform another response applicable to the

   system. Also, confirm that there is no problem with the overall                                                Loss time

   system.

•  Do not connect the thermostat directly to the load power supply. Connect it

   to a contactor or other shutoff device connected above the SSR.                      Using DC Loads

•  Terminals equivalent to Faston #187 are used for the thermostat terminals.

•  Do not place heat-dissipating silicon grease on the thermostat.                      For a DC or L load, a diode should be connected in parallel the load

•  Do not solder the thermostat terminals.                                              to absorb the counter electromotive force of the load.

•  The following diagram shows a protective circuit example.

                                                                       Circuit breaker

                                                                       (contact side)                                                  Load

         Circuit breaker                                         Load                                          SSR                              Load power

         (coil side)      Thermostat    Y92B-P250NF                                            Input                                            supply

   Coil                   (NC contact)

   power                                G3NA

   supply                                             Load side

                                                                                        Fuses

    Input side

                                                                              Circuit   Connect a quick-break fuse in series with the load as a short-circuit

                                                                              breaker   protection measure. Use one of the fuses in the following table or

Ventilating a High-capacity Heat Sink                                                   one with equivalent or better characteristics.

(Y92B-P250NF)                                                                           Recommended Fuses

• Refer to Ventilation Outside the Control Panel.                                           G3NA rated  Fuse model       Manufacturer           Applicable SSR

                                                                                        load current

Operating Conditions                                                                    5A              60LFF5           HINODE ELECTRIC     G3NA-205B

                                                                                        8A              60LFF8           CO.,LTD.            G3NA-210B

•  Do not apply currents exceeding the rated current otherwise, the

   temperature of the G3NA may rise excessively.                                        10 A            60LFF10

•  As protection against accidents due to short-circuiting, be sure to                  15 A            60LFF15                              G3NA-220B

   install protective devices, such as fuses and no-fuse breakers, on                   20 A            60LFF20

   the power supply side.                                                                               50SHA20

•  Do not apply overvoltages to the input circuit or output circuit.                    25 A            60PFF25                              G3NA-240B

   Failure or burning may result.                                                                       50SHA25

•  Do not drop the G3NA or otherwise subject it to abnormal shock.                      30 A            60PFF30

   Malfunction or failure may result.                                                                   50SHA30

•  Keep the cooling system running continuously during the ON/OFF                       40 A            50SHA40

   operation of the SSR. This is to allow residual heat to dissipate                    45 A            50SHA45

   while the SSR is OFF. (load current 75 A, 90 A models)                               50 A            50SHA50                              G3NA-275B-UTU(-2)

•  The Y92B-P250NF is a Class 1 device.                                                 75 A            50SHA75

   If compliance with EU standards is required, ground the Y92B-P250NF.

•  Use the ground terminal on the Heat Sink.                                            80 A            50SHA80                              G3NA-290B-UTU(-2)

   Screw size: M5                       Tightening torque: 2 N·m                        100 A           50SHB100

   Do not use the ground terminal on the fan.

                                                                                        Reverse Connection

EMC Directive Compliance (For -UTU type)                                                The output terminal side of the G3NA-D210B is connected to a built-

EMC directives can be complied with under the following conditions.                     in diode to protect the SSR from damage that may result from

1.  AC-switching models                                                                 reverse connection. The SSR, however, cannot withstand one minute

                                                                                        or more if the wires are connected in reverse. Therefore, pay the

• A capacitor must be connected to the input power supply.                              utmost attention not to make polarity mistakes on the load side.

• A capacitor, varistor and toroidal core must be connected to the

   load power supply.                                                                   Installation and Mounting

• The input cable must be less than 3 m.

                                        Troidal core                                    • Mount the G3NA securely with screws.

                                        Load                                            Keep the screws tightened to a torque of 0.78 to 0.98 N·m.

          Input           G3NA          Output                                          • Mount the Heat Sink securely with screws.

                                                                                        Keep the screws tightened to a torque of 0.98 to 1.47 N·m.

         3 m max.         Recommended Capacitor : 0.05μF, 500 VAC (Load)

                                                     0.1μF,  250 VAC (Input)

                          Recommended Varistor : 470 V, 1750 A

                          Recommended Troidal core : NEC/TOKIN:ESD-R-25B or equivalent

                                                                                                                                                                15
                                                                                                                                                           G3NA

■ Precautions on Operating and Storage Environments

1. Operating Ambient Temperature                                                             3. Vibration and Shock

The rated value for the ambient operating temperature of the G3NA                            Do not subject the G3NA to excessive vibration or shock. Otherwise

is for when there is no heat build-up. For this reason, under                                the G3NA may malfunction and internal components may be

conditions where heat dissipation is not good due to poor ventilation,                       deformed or damaged, resulting in failure of the G3NA to operate.

and where heat may build up easily, the actual temperature of the                            To prevent the G3NA from abnormal vibration, do not install the

G3NA may exceed the rated value resulting in malfunction or                                  G3NA in locations or by means that will subject it to vibration from

burning.                                                                                     other devices, such as motors.

When using the G3NA, design the system to allow heat dissipation

sufficient to stay below the Load Current vs. Ambient Temperature                            4. Solvents

characteristic curve. Note also that the ambient temperature of the

G3NA may increase as a result of environmental conditions (e.g.,                             Do not allow the G3NA or the resin portion of the Fan’s thermostat to

climate or air-conditioning) and operating conditions (e.g., mounting                        come in contact with solvents, such as thinners or gasoline. Doing so

in an airtight panel).                                                                       will dissolve the markings on the G3NA.

2. Transportation                                                                            5. Oil

When transporting the G3NA, observe the following points. Not doing                          Do not allow the G3NA terminal cover to come in contact with oil.

so may result in damage, malfunction, or deterioration of                                    Doing so will cause the cover to crack and become cloudy.

performance characteristics.

• Do not drop the G3NA or subject it to severe vibration or shock.

• Do not transport the G3NA if it is wet.

• Do not transport the G3NA under high temperatures or humidity.

• Do not transport the G3NA without packing it properly.

■ Operation

1. Leakage Current                                                                           2. Screw Tightening Torque

A leakage current flows through a snubber circuit in the G3NA even                           Tighten the G3NA terminal screws properly. If the screws are not

when there is no power input. Therefore, always turn OFF the power                           tight, the G3NA will be damaged by heat generated when the power

to the input or load and check that it is safe before replacing or wiring                    is ON. Perform wiring using the specified tightening torque.

the G3NA.

                                           Switch element  Snubber circuit                   3. Handling Relays

                                                                                             Do not mount the G3NA when your hands are oily or dirty, e.g., with

           Input circuit  Trigger circuit                  Varistor                          metal powder. These may cause G3NA failure.

                                                                            Leakage current  4. Do Not Drop

                                                                                             Be careful not to drop a Relay or Heat Sink onto any part of your

                                                                                             body while working. Injury may result. This is particularly true for the

                                                                                             High-capacity Heat Sink (Y92B-P250NF), which weighs 2.5 kg.

                          ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                          To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                                           In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                                       16
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2016.9

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2016 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

G3NA-D210B-DC5-24       Y92B-N50  Y92B-N100  G3NA-210B-AC200-240  G3NA-240B-AC200-240      G3NA-210B-

AC100-120   G3NA-240B-AC100-120   Y92B-N150  G3NA-225B-AC200-240      G3NA-205B-AC200-240  G3NA-205B-

AC100-120   G3NA-225B-AC100-120   G3NA-D210B-AC100-240  Y92B-A100     G3NA-205B-DC5-24     G3NA-225B-DC5-

24   G3NA-240B-DC5-24   G3NA-210B-DC5-24     Y92B-A250  G3NA-220B-AC100-120  G3NA-220B-AC200-240   G3NA-

220B-DC5-24  G3NA-425B DC5-24     G3NA-440B-AC100-240   G3NA-440B-DC5-24     G3NA-205B-UTU DC5-24  G3NA-

210B-UTU AC200-240     G3NA-210B-UTU DC5-24  G3NA-220B-UTU DC5-24     G3NA-225B-UTU DC5-24      G3NA-240B-

UTU DC5-24   G3NA-410B AC100-240  G3NA-410B-DC5-24      G3NA-420B-DC5-24     G3NA-425B AC100-240   G3NA-

450B DC5-24  G3NA-D210B-UTU DC5-24    G3NA-250B-UTU DC5-24  Y92B-S08N        G3NA-210BL DC5-24    G3NA-220B-

UTU AC100-120  G3NA-220B-UTU AC200/240       G3NA-275B-UTU AC100-240  G3NA-275B-UTU DC5-24        G3NA-290B-

UTU AC100-240  G3NA-290B-UTU DC5-24   G3NA-450B-UTU AC100-240      G3NA-475B-UTU AC100-240        G3NA-475B-

UTU DC5-24   G3NA-490B-UTU AC100-240  G3NA-490B-UTU DC5-24  G3NA-420B AC100-240  G3NA-225B AC100-

120  G3NA-450B-UTU DC5-24   G3NA-425B-2 DC5-24  G3NA440B2AC100240     G3NA490BUTU2DC524         G3NA-450B-2

DC5-24  G3NA-440B-2 DC5-24  G3NA-275B-UTU-2 DC5-24      G3NA-450B-UTU-2DC5-24  G3NA-475B-UTU-2AC100-

240  Y92B-A150NV  G3NA-240B-UTU AC200-240

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
搜索索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved