电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

Y92B-N150

器件型号:Y92B-N150
器件类别:热门应用    机电/工控/自动化   
文件大小:19266.45KB,共16页
厂商名称:OMRON
厂商官网:https://www.omron.com
标准:
下载文档

器件描述

控制器 trk MT heat sink g3n

参数
制造商: Omron
产品种类: 控制器
RoHS:
类型: Solid State Relay
特点: Built-in varistor effectively absorbs external surges

Y92B-N150器件文档内容

Solid State Relays                                                                                CSM_G3NA_DS_E_5_1

G3NA

Wide Lineup of General-purpose Solid State
Relays with Applicable Loads of 5 to 90 A

AC Output Relays with 75-A and 90-A output currents have
been added to the G3NA Series.

All models feature the same compact dimensions to provide a
uniform mounting pitch.

Built-in varistor effectively absorbs external surges.
(except G3NA-D210B)

Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by

TV.
(except G3NA-410B, G3NA-420B, and G3NA-440B)

          Refer to Safety Precautions for All Solid State
          Relays.

Model Number Structure

Model Number Legend

G3NA-@@@@@-@

1    23456 7

1. Basic Model Name                                            5. Terminal Type

G3NA: Solid State Relay                                        B:  Screw terminals

2. Load Power Supply                                           6. Zero Cross Function

Blank: AC output                                               Blank: Equipped with zero cross function
                                                                             (AC-output models only)
D:   DC output

3. Rated Load Power Supply Voltage                             7. Certification

2:   200 VAC or 200 VDC                                        Blank: Standard models (certified by UL and CSA)

4:   400 VAC                                                   UTU: Certified by UL, CSA, and TV

4. Rated Load Current

05:  5A

10:  10 A

20:  20 A

40:  40 A

50:  50 A

75:  75 A

90:  90 A

                                                                                                                      1
                                                                                                                   G3NA

Ordering Information

List of Models

        Isolation       Zero cross     Indicator    Applicable output load     Rated input voltage                  Model
                         function                           (See note 1.)
Phototriac Coupler                  Yes                                     5 to 24 VDC             G3NA-205B DC5-24
Photocoupler          Yes           (Yellow)      5 A at 24 to 240 VAC      100 to 120 VAC          G3NA-205B AC100-120
                                                  (See note 2.)             200 to 240 VAC          G3NA-205B AC200-240
Phototriac Coupler                                                          5 to 24 VDC             G3NA-210B DC5-24
Photocoupler                                      10 A at 24 to 240 VAC     100 to 120 VAC          G3NA-210B AC100-120
                                                  (See note 2.)             200 to 240 VAC          G3NA-210B AC200-240
Phototriac Coupler                                                          5 to 24 VDC             G3NA-220B DC5-24
Photocoupler                                      20 A at 24 to 240 VAC     100 to 120 VAC          G3NA-220B AC100-120
                                                  (See note 2.)             200 to 240 VAC          G3NA-220B AC200-240
Phototriac Coupler                                                          5 to 24 VDC             G3NA-240B DC5-24
Photocoupler                                      40 A at 24 to 240 VAC     100 to 120 VAC          G3NA-240B AC100-120
                                                  (See note 2.)             200 to 240 VAC          G3NA-240B AC200-240
Phototriac Coupler                                                          5 to 24 VDC             G3NA-275B-UTU DC5-24
Photocoupler                                      75 A at 24 to 240 VAC     100 to 240 VAC          G3NA-275B-UTU AC100-240
Phototriac Coupler                                (See note 2.)             5 to 24 VDC             G3NA-290B-UTU DC5-24
Photocoupler                                      90 A at 24 to 240 VAC     100 to 240 VAC          G3NA-290B-UTU AC100-240
                                                  (See note 2.)             5 to 24 VDC             G3NA-D210B DC5-24
                      ---                         10 A at 5 to 200 VDC      100 to 240 VAC          G3NA-D210B AC100-240
                      Yes                                                   5 to 24 VDC             G3NA-410B DC5-24
                                                  10 A at 200 to 480 VAC    100 to 240 VAC          G3NA-410B AC100-240
                                                                            5 to 24 VDC             G3NA-420B DC5-24
                                                  20 A at 200 to 480 VAC    100 to 240 VAC          G3NA-420B AC100-240
                                                                            5 to 24 VDC             G3NA-440B DC5-24
                                                  40 A at 200 to 480 VAC    100 to 240 VAC          G3NA-440B AC100-240
                                                                            5 to 24 VDC             G3NA-450B DC5-24
                                                  50 A at 200 to 480 VAC
                                                  (See note 2.)             5 to 24 VDC             G3NA-475B-UTU DC5-24
                                                  75 A at 200 to 480 VAC    100 to 240 VAC          G3NA-475B-UTU AC100-240
                                                  (See note 2.)             5 to 24 VDC             G3NA-490B-UTU DC5-24
                                                  90 A at 200 to 480 VAC    100 to 240 VAC          G3NA-490B-UTU AC100-240
                                                  (See note 2.)

*The standard models are certified by UL and CSA. To order a TV-certified model, add "-UTU" to the model number.

Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The applicable load de-
            pends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.

        2. Loss time increases under 75 VAC. (Refer to page 14.) Confirm operation with the actual load.

Accessories (Order Separately)

One-touch Mounting Plates                                       Mounting Bracket

               Model                                                  Model                        Applicable SSR
R99-12 FOR G3NA                                                 R99-11       G3NA-240B, G3NA-440B

Heat Sinks

Slim Models Enabling DIN-track Mounting                         Low-cost Models

      Model                        Applicable SSR                     Model                        Applicable SSR
Y92B-N50     G3NA-205B, G3NA-210B, G3NA-D210B,                  Y92B-A100    G3NA-205B, G3NA-210B, G3NA-D210B,
             G3NA-410B, G3NA-210T(L)                                         G3NA-220B, G3NA-410B, G3NA-420B
Y92B-N100    G3NA-220B, G3NA-420B, G3NA-220T(L)                 Y92B-A150N   G3NA-240B, G3NA-440B
Y92B-N150    G3NA-240B, G3NA-440B                               Y92B-A250    G3NA-440B
Y92B-P250    G3NA-450B
Y92B-P250NF  G3NA-275B-UTU, G3NA-290B-UTU,
(See note.)  G3NA-475B-UTU, G3NA-490B-UTU

Note: The Y92B-P250NF is scheduled for release on May 1, 2004.

                                                                                                                                                    2
                                                                                                                G3NA

Specifications

Ratings

Input (at an Ambient Temperature of 25C)

Model      Rated voltage      Operating voltage      Impedance                           Voltage level
                                                    (See note 1.)
                                                                             Must operate voltage  Must release voltage

G3NA-2@@B  5 to 24 VDC        4 to 32 VDC        7 mA max. (See note 2.) 4 VDC max.                1 VDC min.
           100 to 120 VAC
           200 to 240 VAC     75 to 132 VAC      36 k20% (See note 4.) 75 VAC max. (See note 3.) 20 VAC min. (See note 3.)

                              150 to 264 VAC 72 k20%              150 VAC max. (See note 3.) 40 VAC min. (See note 3.)
                                                                                                                           (See note 5.)

G3NA-4@@B  5 to 24 VDC        4 to 32 VDC        5 mA max. (See note 2.) 4 VDC max.                1 VDC min.

G3NA-D210B 100 to 240 VAC     75 to 264 VAC      72 k20%          75 VAC max.                     20 VAC min.

G3NA-275B-UTU 5 to 24 VDC     4 to 32 VDC        15 mA max.        4 VDC max.                      1 VDC min.

G3NA-290B-UTU 100 to 240 VAC  75 to 264 VAC      72 k20%          75 VAC max.                     20 VAC min.

G3NA-475B-UTU 5 to 24 VDC     4 to 32 VDC        7 mA max.         4 VDC max.                      1 VDC min.

G3NA-490B-UTU 100 to 240 VAC  75 to 264 VAC      72 k20%          75 VAC max.                     20 VAC min.

Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,
            the input impedance is measured at 120 VAC).

        2. With constant current input circuit system. The impedance for the G3NA-2@@B-UTU is 15 mA max.
        3. Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data on page 6 for further

            details.
        4. The G3NA-240B(-UTU) is 72k20%.
        5. The G3NA-240B(-UTU) is 20 VAC min.

Output

Model                                                       Applicable load

           Rated load voltage   Load voltage range           Load current (See note 1.)                  Inrush current

                               19 to 264 VAC                With heat sink   Without heat sink     60 A (60 Hz, 1 cycle)
                                                             (See note 2.)                         150 A (60 Hz, 1 cycle)
                               180 to 528 VAC
G3NA-205B  24 to 240 VAC       19 to 264 VAC        0.1 to 5 A (at 40C) 0.1 to 3 A (at 40C)      220 A (60 Hz, 1 cycle)
                               180 to 528 VAC
G3NA-210B                      19 to 264 VAC        0.1 to 10 A (at 40C) 0.1 to 4 A (at 40C)     440 A (60 Hz, 1 cycle)
                               180 to 528 VAC
G3NA-410B  200 to 480 VAC      180 to 528 VAC       0.2 to 10 A (at 40C) 0.2 to 4 A (at 40C)     20 A (10 ms)
                               4 to 220 VDC                                                        800 A (60 Hz, 1 cycle)
G3NA-220B  24 to 240 VAC       19 to 264 VAC        0.1 to 20 A (at 40C) 0.1 to 4 A (at 40C)     800 A (60 Hz, 1 cycle)
                               180 to 528 VAC                                                      1,000 A (60 Hz, 1 cycle)
G3NA-420B  200 to 480 VAC      19 to 264 VAC        0.2 to 20 A (at 40C) 0.2 to 4 A (at 40C)     1,000 A (60 Hz, 1 cycle)
                               180 to 528 VAC
G3NA-240B  24 to 240 VAC                            0.1 to 40 A (at 40C) 0.1 to 6 A (at 40C)

G3NA-440B  200 to 480 VAC                           0.2 to 40 A (at 40C) 0.2 to 6 A (at 40C)

G3NA-450B  200 to 480 VAC                           0.2 to 50 A (at 40C) 0.2 to 6 A (at 40C)

G3NA-D210B 5 to 200 VDC                             0.1 to 10 A (at 40C) 0.1 to 4 A (at 40C)

G3NA-275B-UTU 24 to 240 VAC                         1 to 75 A (at 40C)      1 to 7 A (at 40C)

G3NA-475B-UTU 200 to 480 VAC                        1 to 75 A (at 40C)      1 to 7 A (at 40C)

G3NA-290B-UTU 24 to 240 VAC                         1 to 90 A (at 40C)      1 to 7 A (at 40C)

G3NA-490B-UTU 200 to 480 VAC                        1 to 90 A (at 40C)      1 to 7 A (at 40C)

Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data
            on page 5.

        2. When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.

                                                                                                                                                 3
                                                                                                                  G3NA

Characteristics

       Item    G3NA- G3NA- G3NA- G3NA- G3NA- G3NA- G3NA-                G3NA- G3NA-               G3NA-  G3NA-    G3NA-          G3NA-
                205B 210B 220B 240B 410B 420B 440B                       450B D210B               275B-  290B-    475B-          490B-
Operate time                                                                                       UTU    UTU      UTU            UTU
              1/2 of load power source cycle + 1 ms max. (DC input)
Release time  3/2 of load power source cycle + 1 ms max. (AC input)     1 ms 1/2 of load power source cycle + 1 ms
                                                                        max. (DC max. (DC input)
Output ON                                                               input) 3/2 of load power source cycle + 1 ms
voltage drop                                                            30 ms max. (AC input)
Leakage                                                                 max. (AC
current                                                                 input)

Insulation    1/2 of load power source cycle + 1 ms max. (DC input)     5 ms 1/2 of load power source cycle + 1 ms
resistance    3/2 of load power source cycle + 1 ms max. (AC input)     max. (DC max. (DC input)
Dielectric                                                              input) 3/2 of load power source cycle + 1 ms
strength                                                                30 ms max. (AC input)
Vibration                                                               max. (AC
resistance                                                              input)
Shock
resistance    1.6 V (RMS) max.               1.8 V (RMS) max.           1.5 V                     1.6 V (RMS) max. 1.8 V (RMS) max.
Ambient       5 mA max. (at 100 VAC)                                    max.
temperature   10 mA max. (at 200 VAC)        10 mA max. (at 200 VAC)
Ambient                                      20 mA max. (at 400 VAC)    5 mA                      5 mA max. (at   10 mA max. (at
humidity      100 M min. (at 500 VDC)                                   max.                      100 VAC)        200 VAC)
Weight                                                                  (at 200                   10 mA max. (at  20 mA max. (at
                                                                        VDC)                      200 VAC)        400 VAC)

              2,500 VAC, 50/60 Hz for 1 min                                                       4,000 VAC, 50/60 Hz for 1 min

              Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)

              Destruction: 1,000 m/s2

              Operating: 30C to 80C (with no icing or condensation)
              Storage: 30C to 100C (with no icing or condensation)

              Operating: 45% to 85%

              Approx. 60 g             Approx. Approx. 80 g             Approx. Approx. 120 g
                                       70 g                             70 g

                                                                                                                                        4
Engineering Data                                                                                                                                                        G3NA

Load Current vs. Ambient Temperature                                                                                                             G3NA-220B/420B

G3NA-205B                                                                      G3NA-210B/410B                                                                With standard heat sink
                                                                                                                                                             (Y92B-A100 or
Load current (A)       With standard heat sink               Load current (A)  20                                                                            Y92B-N100) or aluminumLoad current (A)
                       (Y92B-A100 or                                           16                                                                            plate measuring 200 mm
                       Y92B-N50) or aluminum                                                                                                                 x 200 mm x t3.2 mm
                       plate measuring 75 mm                                   10                                                                            (W x H x t)
                       x 75 mm x t3.2 mm                                             With standard heat sink                                                With iron plate measuring
                       (W x H x t)                                                   (Y92B-A100 or                                                          100 x 100 x t0.8 (W x H x t)
                                                                                     Y92B-N50) or aluminum
                         Without heat sink                                                                                                                    Without heat sink
                                                                                8 plate measuring 150 mm
                              Ambient temperature (C)                               x 150 mm x t3.2 mm                                                        Ambient temperature (C)

                  G3NA-240B                                                     6 (W x H x t)                                                      G3NA-450B
                                                                                5 With iron plate measuring
                  50                                                            4 100 x 100 x t0.8 (W x H x t)                                     60
                  45
                                                                                     Without heat sink                                             50
                  40                                                                                                                                    With standard heat sink
                        With standard heat                                      2                                                                       (Y92B-P250)
                        sink (Y92B-A150N or
                        Y92B-N150)                                              0                                                                  40

                  30                                                                    Ambient temperature (C)                                   30

                                                                               G3NA-440B               With Y92B-A250                              20
                                                                                                       or heat sink with a
                                                                                 50                    radiation efficiency                        10 Without heat sink
                                                                                 45                    of 1C/W.                                    6
                                                                                                                                                    0
                                                                                 40                                                                 -30-20 0 20 40 60 80 100

Load current (A)                                             Load current (A)  30  With standard heat                           Load current (A)              Ambient temperature (C)

                                                                                   sink (Y92B-A150N                                             G3NA-D210B

                                                                                   or Y92B-N150)                                                 20

                  20                                                           20                                                                10
                                                                                                                                                       With standard heat sink
                        With iron plate measuring    80 100                           With iron plate measuring  80 100                                (Y92B-A100 or Y92B-N50)
                                                                                                                                                       or aluminum plate measuring
                  12 100 x 100 x t0.8 (W x H x t)                              12 100 x 100 x t0.8 (W x H x t)                                         150 mm x 150 mm x t3.2 mm
                  10                                                           10                                                                      (W x H x t)

                   6 Without heat sink                                          6 Without heat sink                                                6
                   4                                                            4                                                                  5 With iron plate measuring
                   2                                                            2
                   -030-20 0 20 40 60                                           -030-20 0 20 40 60                                                    100 x 100 x t0.8 (W x H x t)
                                                                                                                                                   4
                       Ambient temperature (C)                                    Ambient temperature (C)
                                                                                                                                                        Without heat sink
                  G3NA-275B-UTU                                                G3NA-290B-UTU                                                       2
                  G3NA-475B-UTU                                                G3NA-490B-UTU                                                      -030-20 0 20 40 60 80 100

                  80                                                           100                                                                         Ambient temperature (C)
                  75
                  70 0.6C/W with                                              90

                           Heat Sink                                           80  0.3C/W with
                                                                                   Heat Sink
                  60
Load current (A)                                             Load current (A)  70                                               Load current (A)
                  50
                                                                               60

                  40   Using the Y92B-P250NF                                   50  Using the Y92B-P250NF

                  30                                                           40
                                                                               35
                                                                               30

                  20 With iron plate measuring                                     With iron plate measuring
                       100 x 100 x t0.8 (W x H x t)                            20  100 x 100 x t0.8 (W x H x t)
                  12
                  10
                    7                                                          12
                  20                                                           7
                       Without heat sink             4A                        20  Without heat sink                        4A
                                                                                                                 60 70 80 100
                  -30-20 0 20 40 60 70 80 100                                  -30-20 0 20 40

                       Ambient temperature (C)                                    Ambient temperature (C)

Note: The ambient operating temperature of the Y92B-P250NF is
        -30 to 70C. Be sure the operating temperature is within this range.

                                                                                                                                                                                          5
One Cycle Surge Current                                                                                                                                                                                                                                                  G3NA

The values shown by the solid line are for non-repetitive inrush currents.                                                                                                                                                                                   G3NA-240B
Keep the inrush current below the values shown by the dotted line if it occurs repetitively.                                                                                                                                                                 G3NA-440B/-450B

                              G3NA-205B                                                                 G3NA-210B                                                                          G3NA-220B
                                                                                                        G3NA-410B                                                                          G3NA-420B

Inrush current (A peak)  60                                               Inrush current (A peak)  150                                                       Inrush current (A peak)                                           Inrush current (A peak)

                                                                                                                                                                                      200                                                               400

                         40                                                                        100                                                                                150                                                               300

                                                                                                                                                                                      100                                                               200

                         20                                                                        50

                                                                                                                                                                                      50                                                                100

                         0                                5,000                                    0                               5,000                                              010 30 50 100 200 500 1,000       5,000                           0                            5,000
                          10 30 50 100 200 500 1,000                                                10 30 50 100 200 500 1,000                                                                                                                           10 30 50 100 200 500 1,000

                                          Energized time (ms)                                                             Energized time (ms)                                                         Energized time (ms)                                    Energized time (ms)

                                                                                                        G3NA-275B-UTU                                                                      G3NA-290B-UTU

                              G3NA-D210B                                                                G3NA-475B-UTU                                                                      G3NA-490B-UTU

Inrush current (A peak)  30                                               Inrush current (A peak)  900                                                       Inrush current (A peak)  1,200
                         28

                         26                                                                        800

                         24                                                                                                                                                           1,000

                         22                                                                        700

                         20                                                                        600                                                                                800

                         18

                         16                                                                        500

                         14                                                                                                                                                           600

                         12                                                                        400

                         10                                                                        300                                                                                400

                         8

                         6                                                                         200

                         4                                                                         100                                                                                200

                         2                                                                           0                                                                                  0
                                                                                                       10                                                                                 10
                         010 20 30 50 70 100 200 300 500  1,000 2,000                                         30 50 100   300           1,000                                                 30 50 100            300  1,000

                                         Energized time (ms)                                                              Energized time (ms)                                                         Energized time (ms)

Temperature

Characteristics

(for Must Operate

Voltage and Must                                                          Heat Sink Area
                                                                          vs. Load Current
Release Voltage)

                              G3NA-2@@B AC input                                                              G3NA-220B

Variation rate (%)       40                                                                        3,000
                                                                    Heat sink area (cm2)
                                                                                                   2,000 Ambient          Ambient

                                                                                                              temperature 80C temperature 40C

                         20                                                                        1,000

                                                                                                   700

                                                                                                   500                                                                                Note: The heat sink area refers to the combined area
                                                                                                                                                                                              of the sides of the heat sink that radiate heat.
                                                                                                   300                                                                                        For example, when a current of 18 A is allowed
                                                                                                                                                                                              to flow through the SSR at 40C, the graph
                         0                                                                         200                                                                                        shows that the heat sink area is about 450 cm2.
                                                                                                                                                                                              Therefore, if the heat sink is square, one side of
                                                                                                                          Aluminum plate                                                      the heat sink must be 15 cm ( 450 (cm2)/2 ) or
                                                                                                                                                                                              longer.
                                                                                                   100                    3.2 mm thick
                                                                                                                                                                                      Thermal Resistance Rth of Heat Sinks
                         -20                                                                       70                                                                                 (Examples)
                                                                                                   50

                                                                                                          30
                                                                                                          20
                         -40

                         -30 -20 0 20 40 60 80 100                                                      0 2 4 6 8 10 12 14 16 18 20 22 24
                                                Ambient temperature (C)                                                                   Load current (A)

Thermal Resistance Rth (Back of

Junction SSR) (Examples)

                     Model                                                                                    Rth (C/W)                                                                                   Model                                             Rth (C/W)
                                                                                                                  3.22                                                                Y92B-N50                                                                    2.8
G3NA-205B                                                                                                         2.62                                                                Y92B-N100                                                                  1.63
                                                                                                                  1.99                                                                Y92B-N150                                                                  1.38
G3NA-210B                                                                                                         0.45                                                                Y92B-A100                                                                  1.63
                                                                                                                  0.45                                                                Y92B-A150N                                                                 1.37
G3NA-220B                                                                                                                                                                             Y92B-A250                                                                  1.00
                                                                                                                  2.62                                                                Y92B-P250NF                                                                0.46
G3NA-240B
                                                                                                                                                                                      Note: When using a commercially available heat sink, use one with a
G3NA-275B-UTU                                                                                                                                                                                 thermal resistance equal to or less that the OMRON Heat Sink.
G3NA-475B-UTU
G3NA-290B-UTU
G3NA-490B-UTU

G3NA-D210B

                                                                                                                                                                                                                                                                                            6
                                                                                                                                                               G3NA

Dimensions

Relays

Note: All units are in millimeters unless otherwise indicated.

G3NA-205B, G3NA-210B, G3NA-220B, G3NA-410B, G3NA-420B

                                                             11.9         Four, M4 x 8                    Mounting Holes
                                                                                                                       Two, 4.3-dia.
                                                                   4.5 dia. screws                                     or M4 holes         Terminal Arrangement/
                                                                                                                                           Internal Connections
                                                                                                        47.60.2                           (Top View)

                                                                                                                                                 Load            Load
                                                                                                                                                                 power
58 max. 47.5 44                                                                                                                                                  supply

                                                                                                                                                 Output

                                                                                                                                           1             2

                                                                                            15.8 *18.9                                     (-)           (+)

                                                                    4.5   Operating                                                        4             3
                                                                     25
                                                                          indicator 25 max. *28 max.                                             Input
                                                                 43 max.
                                                                                            27 max. *30 max.

                                                                                                       *Size for G3NA-410B and G3NA-420B.

G3NA-240B, G3NA-440B                                         11.9                                             Mounting Holes               Terminal Arrangement/
                                                                      4.5 dia. Two, M5 x 12 screws                                         Internal Connections
                                            58 min. 47.5 44                                                                 Two, 4.3-dia.  (Top View)
                                                                                                                            or M4 holes
                                                                                                                                                 Load            Load
                                                                                                                                                                 power
                                                                                                                                                 Output          supply

                                                                                                                   47.60.2                   1             2

                                                                          Operating             15.8 *18.9                                 (-)           (+)
                                                                          indicator         25 max. *28 max.
                                                                     4.5                    27 max. *30 max.                                  4             3
                                                                     25   Two,
                                                                          M4x8                                                                   Input
                                                                 43 max.

                                                                                                       *Size for G3NA-240B.

G3NA-D210B

Note: The load can be connected to either the positive or negative side.

                                                             11.9         Four, M4 x 8                   Mounting Holes                    Terminal Arrangement/
                                                                                                                                           Internal Connections
                                                                   4.5 dia. screws                                      Two, 4.3-dia.      (Top View)
                                                                                                                        or M4 holes
                                                                                                                                                 Load
                                                                                                       47.60.2
58 max. 47.5 44                                                                                                                                  Output        Load
                                                                                                                                                               power
                                                                                                                                                               supply

                                                                                                                                           1             2
                                                                                                                                           -             +

                                                                                                                                           (-)           (+)

                                                                          Operating            15.8                                        4             3
                                                                          indicator         25 max.
                                                                  4.5                       27 max.                                              Input
                                                                 25
                                                                                                                             Note: When connecting the load, either the
                                                             43 max.                                                                 positive or negative side of the load
                                                                                                                                     terminals can be connected.

G3NA-275B-UTU, G3NA-475B-UTU, G3NA-290B-UTU, G3NA-490B-UTU

                                                             12    4.5 dia. Two, M5 x 12

                                                                          screws

                                                                                                        Mounting Holes                     Terminal Arrangement/
                                                                                                                                           Internal Connections
                                                                                                                  Two, 4.3-dia.            (Top View)
                                                                                                                  or M4 holes
                                                                                                                                                        Load

            58 max.47.5 44

                                                                                                                                                 Output

                                                                                                        47.60.2                           1             2 Load

                                                                                 Operating                                                                     power
                                                                          4.5 indicator
                                                                                                 16.8                                                          supply
                                                                                            26 max.
                                                                    8.2   Two, M4 x         28 max.                                        (-)           (+)
                                                                    25    8 screws
                                                                                                                                           4     Input   3
                                                                 43 max.

                                                                                                                                                                            7
                                                                                                                                                                G3NA

Options (Order Separately)                                                                            To mount the Relay to DIN
                                                                                                       Track, first mount it to the
One-touch Mounting Plate                                                                               One-touch Mounting Plate
                                                                                                       and then attach it to the DIN
The One-touch Mounting Plate is used to mount the GN3A to a DIN                                        Track as shown in the
Track.                                                                                                 diagram.

R99-12 FOR G3NA (for the G3NA and G3NE)

                                                                                Two, M4 mounting
                                                                                holes for the G3NA

                Two, M4 mounting       30                                                              To remove the Relay from
                                                                                                       the DIN Track, pull down on
                holes for the G3NE     44                                                              the tab with a screwdriver in
                                                                                                       the direction of the arrow.

                                                                                                       When a Relay is mounted to DIN Track, use it within the rating for a
                                                                                                         Relay without a heat sink.

                                                                                                       Use the following DIN Tracks: PFP-100N or PFP-100N2.

Mounting Bracket

R99-11 (for the G3NA-240B, G3NA-440B)

Use Mounting Bracket R99-11 so that the G3NA-240B/-440B can be
mounted with the same pitch as that of the G3N-240B.

                                               16
                                                 8

                12.5                5

            21                                                                                                       56

                             4                   4.6

Heat Sinks

Y92B-N50 Heat Sink (for the G3NA-205B, G3NA-210B, G3NA-D210B, G3NA-410B, G3NE-210T(L))

For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs).

The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the
mounting hole dimensions.

                                                                                                                                              Mounting Holes

                      4.6 dia. Two, M3 holes                                                                                          Two, 4.4-dia.
                                                        Two, M4 holes Two, 3.2-dia. holes                                             or M4 holes

                35 30.50.3                                     44 max. 30                                      47 max.

                                       47.6           5.6                                           5  6        4.5                                     900.4

                                       77 max.                                                         51 max.                              350.2
                                                                                                                                      Weight: approx. 200 g
                                       900.3

                                       100 max.

                                                                                                                                                                               8
                                                                                                                                                         G3NA

Y92B-N100 Heat Sink (for the G3NA-220B, G3NA-420B, G3NE-220T(L))

For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs).

The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the

mounting hole dimensions.                          Two, M3 holes Two, M4         Two, 3.2-dia. holes                   Mounting Holes
                                         4.6 dia.                       holes
                                                                                                                                Two, 4.4-dia.
                                                                                                                                or M4 holes

35 30.50.3                                                         71 max. 30                               75 max.

                                                                                                                                          900.4

                                                   47.6             5.6          28 5                    13 4.5

                                                   77 max.                       100 max.
                                                   900.3

                                                   100 max.                                                                    350.2
                                                                                                                       Weight: approx. 400 g

Y92B-N150 Heat Sink (for the G3NA-240B, G3NA-440B)

For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs).

The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the

mounting hole dimensions.                                                        Two, 3.2-dia. holes                   Mounting Holes
                                                              47.6

4.6 dia.                                                            Three,                                                                Two, 4.4-dia.
                                                                    M4 holes                                                              or M4 holes

35                                                                  100 max. 30                              104 max.

                                                   560.3           5.6          28 5                    13  4.5
                                                                                      100 max.
                                                   77 max.

                                                   900.3                                                              Weight: approx. 560 g

                                                   100 max.

Y92B-P250NF Heat Sink (for the G3NA-275B-UTU, G3NA-475B-UTU, G3NA-290B-UTU, G3NA-490B-UTU)

The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the

mounting hole dimensions.
Observe the precautions given in Mounting Method under Precautions for Correct Use.

                                                                    172 max.           Fan power supply, 200 VAC 50/60 Hz                               Mounting Holes
                                                                     160 max.                                                                                   640.3
                                                                    120                                                        133.4
                                                                                                                              120 max.
                                                                                                                               105

                                                                                       M4                                                      1300.3
                                                                                              110max.
    80 max. 64

    Two, 4.6-dia. holes

                                                                    47.6       Two, M4 holes Thermostat           Weight: approx. 2.5 kg                 Two, 4.5-dia. or
                                                                                                                                                         M4 holes
                                                                                 NC contact, 90C

                                                                                                                                                                           9
Y92B-P250                                                                                                                                      G3NA

               Two, M4       Four, M4                                                                              Mounting Holes
               Depth 10                                                                                                             Four, 4.5 dia. or M4

                       47.6                             190.5 max.

Four, R2.5

                       130.5 max.

                                                  70 max.

Y92B-A100 Heat Sink        Y92B-A150N Heat Sink                          Y92B-A250 Heat Sink
(for the G3NA-205B,        (for the G3NA-240B,                           (for the G3NA-440B)
G3NA-210B,                 G3NA-440B)
G3NA-220B,                                                          Three, M4 holes
G3NA-410B,             Three, M4 holes
G3NA-420B,
G3NA-D210B)

Two, M4 holes
900.1                                                                                                                                               80.5 max.102 max.
                                             900.1                                                                                                  1.5
                                                                                                           900.1
                             R2.2                 47.6                                                             R2.2 47.6

            47.6                           500.1                                                                              500.1           30      9.6
           500.1                         560.5                                                                              560.5      45.5 max.     2
           100 max.                    150 max.
                                                                                                                                250 max.             1.5
Weight: approx. 210 g        Weight: approx. 310 g                                                                 Weight: approx. 510 g

Mounting Holes
Y92B-A100
Y92B-A150
Y92B-A250

                      Four, 4.3-dia. or M4 holes

For surface mounting, a 30% derating of the load current is required (from the Load Current vs. Ambient Temperature graphs).

The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the
mounting hole dimensions.

                                                                                                                                                                        10
                                                                                                                  G3NA

Safety Precautions                                                          3. Wire the G3NA and tighten screws correctly, observing the
                                                                                following precautions
Refer to Safety Precautions for All Solid State Relays.                         Heat generated by a terminal error may occasionally result in fire
                                                                                damage. Do not operate if the screws on the output terminal are
                            !CAUTION                                            loose.

  Touching the charged section may occasionally cause                            Abnormal heat generated by wires may occasionally result in
  minor electric shock. Do not touch the G3NA terminal                            fire damage. Use wires suitable for the load current.
  section (the charged section) when the power supply
  is ON. Be sure to attach the cover before use.                            Abnormal heat generated by terminals may occasionally result
                                                                              in fire damage. Do not operate if the screws on the output
                            !CAUTION                                          terminal are loose.

  The G3NA and heat sink will be hot and may                                Tightening Torque
  occasionally cause minor burns. Do not touch the
  G3NA or the heat sink either while the power supply is                    Screw size Tightening torque
  ON, or immediately after the power is turned OFF.
                                                                            M4  1.2 Nm
                            !CAUTION
                                                                            M5  2.0 Nm
  The internal snubber circuit is charged and may
  occasionally cause minor electric shock. Do not touch                      Abnormal heat generated by terminals may occasionally result
  the G3NA's main circuit terminals immediately after                         in fire damage. When tightening terminal screws, be sure that
  the power is turned OFF.                                                    no non-conductive foreign matter is caught in screw.

                            !CAUTION                                        For GN3A Relays of 40 A or higher, use crimp terminals of an
                                                                              appropriate size for the wire diameter for M5 terminals.
  Be sure to conduct wiring with the power supply turned
  OFF, and always attach the terminal cover after                            Do not use any wires with damaged sheaths. These may cause
  completing wiring. Touching the terminals when they                         electric shock or leakage.
  are charged may occasionally result in minor electric
  shock.                                                                     Do not place wiring in the same conduit or duct as high-voltage
                                                                              lines. Induction may cause malfunction or damage.
                            !CAUTION
                                                                            Use wires of an appropriate length, otherwise malfunction and
  Do not apply a short-circuit to the load side of the                        damage may result due to induction.
  G3NA. The G3NA may rupture. To protect against
  short-circuit accidents, install a protective device, such                Mount the DIN Track securely. Otherwise, the DIN Track may
  as a quick-burning fuse, on the power supply line.                          fall.

Precautions for Safe Use                                                       Be sure that the G3NA clicks into place when mounting it to DIN
                                                                                  Track. The G3NA may fall if it is not mounted correctly.
Although OMRON continuously strives to improve the quality and
reliability of our relays, the G3NA contains semiconductors, which               Do not mount the G3NA when your hands are oily or dirty, e.g.,
are generally prone to occasional malfunction and failure.                        with metal powder. These may cause G3NA failure.
Maintaining safety is particularly difficult if a relay is used outside of
its ratings. Always use the G3NA within the rated values. When using             Tighten the G3NA screws securely.
the G3NA, always design the system to ensure safety and prevent                   Tightening torque: 0.78 to 0.98 Nm
human accidents, fires, and social damage even in the event of
G3NA failure, including system redundancy, measures to prevent                   Tighten the heat sink screws securely.
fires from spreading, and designs to prevent malfunction.                         Tightening torque: 0.98 to 1.47 Nm

1. G3NA malfunction or fire damage may occasionally occur. Do not           4. Preventing Overheating
    apply excessive voltage or current to the G3NA terminals.                   When using the High-capacity Heat Sink (Y92B-P250NF), always
                                                                                use a thermostat or other method to protect from overheating in
2. Heat Dissipation                                                             the event that the fan stops.
    Do not obstruct the airflow to the G3NA or heat sink. Heat
      generated from an G3NA error may occasionally cause the               5. Do Not Touch Fan Blades
      output element to short, or cause fire damage.                            When the fan is operating, do not touch the fan blades with any
                                                                                part of your body or allow foreign matter to come into contact with
    Be sure to prevent the ambient temperature from rising due to             the blades. Always attach the enclosed finger guard when using
      the heat radiation of the G3NA. If the G3NA is mounted inside a           the G3NA.
      panel, install a fan so that the interior of the panel is fully
      ventilated.                                                           6. Operating Conditions

    Mount the G3NA in the specified orientation. If the G3NA is                Only use the G3NA with loads that are within the rated values.
      mounted in any other orientation, abnormal heat generation                  Using the G3NA with loads outside the rated values may result
      may cause output elements to short or may cause burning.                    in malfunction, damage, or burning.

    Do not use the G3NA if the heat sink fins are bent, e.g., as the       Use a power supply within the rated frequency range. Using a
      result of dropping the G3NA. Heat dissipation characteristics will      power supply outside the rated frequency range may result in
      be reduced, possibly causing G3NA failure.                              malfunction, damage, or burning.

    Apply a thin layer of Toshiba Silicone's YG6260 or Sinetsu            7. Do not transport the G3NA under the following conditions. Failure
      Silicone's G746, or a similar product to the heat sink before             or malfunction may occur.
      mounting
                                                                                 Conditions under which the G3NA will be exposed to water
    If a material with high thermal resistance, such as wood, is
      used, heat generated by the G3NA may occasionally cause fire          High temperatures or high humidity
      or burning. When installing the G3NA directly into a control
      panel so that the panel can be used as a heat sink, use a panel       Without proper packing
      material with low thermal resistance, such as aluminum or steel.

    Use the specified heat sink or one with equivalent or better
      characteristics.

                                                                                                                                                    11
                                                                                                                                                                                     G3NA

Operating and Storage Locations                                             Relationship between SSRs and Duct Height

Do not use or store the G3NA in the following locations. Doing so           Incorrect Example                   Countermeasure 1 Countermeasure 2
may result in damage, malfunction, or deterioration of performance
characteristics.                                                                                          Duct  50 mm max.                                                           Duct
                                                                                                                (A height of no
Do not use or store in locations subject to direct sunlight.                                                  more than half
Do not use in locations subject to ambient temperatures outside                                               the SSR's height
                                                                                                                is recommended.)
  the range 20 to 60C.
Do not use in locations subject to relative humidity outside the          Mounting surface                                                                                         Airflow
                                                                                                                      Mounting surface
  range 45% to 85% or locations subject to condensation as the                                                                                               Mounting surface
  result of severe changes in temperature.                                  Vertical                                                                                           Base
Do not store in locations subject to ambient temperatures outside         direction
  the range 30 to 70C.
Do not use or store in locations subject to corrosive or flammable        Duct                                Duct                                                                 Duct
  gases.
Do not use or store in locations subject to dust (especially iron         Do not surround the SSR             Use short ducts.     If the ducts cannot be
  dust) or salts.                                                           with ducts, otherwise the                                shortened, place the SSR on
Do not use or store in locations subject to shock or vibration.           heat radiation of the SSR                                a metal base so that it is not
Do not use or store in locations subject to exposure to water, oil, or    will be adversely affected.                              surrounded by the ducts.
  chemicals.
Do not use or store in locations subject to high temperatures or          Ventilation Outside the Control Panel
  high humidity.
Do not use or store in locations subject to salt damage.                                                      Be aware of airflow
Do not use or store in locations subject to rain or water drops.
                                                                                                                Duct
Precautions for Correct Use
                                                                                                                                                              Ventilation
Please observe the following precautions to prevent failure to                                                                                                outlet
operate, malfunction, or undesirable effect on product performance.                                                                                           (axial fan)

Before Actual Operation                                                                   Air inlet

1. The G3NA in operation may cause an unexpected accident.                  If the air inlet or air outlet has a filter, clean the filter regularly to
    Therefore it is necessary to test the G3NA under the variety of         prevent it from clogging to ensure an efficient flow of air.
    conditions that are possible. As for the characteristics of the
    G3NA, it is necessary to consider differences in characteristics        Do not locate any objects around the air inlet or air outlet, otherwise
    between individual SSRs.                                                the objects may obstruct the proper ventilation of the control panel.

2. Unless otherwise specified, the ratings in this catalog are tested       A heat exchanger, if used, should be located in front of the SSRs to
    values in a temperature range between 15C and 30C, a relative         ensure the efficiency of the heat exchanger.
    humidity range between 25% and 85%, and an atmospheric
    pressure range between 88 and 106 kPa (standard test                     Please reduce the ambient temperature of SSRs.
    conditions according to JIS C5442). It will be necessary to               The rated load current of an SSR is measured at an ambient
    provide the above conditions as well as the load conditions if the        temperature of 40C.
    user wants to confirm the ratings of specific G3NAs.
                                                                            An SSR uses a semiconductor in the output element. This causes
Mounting Method                                                               the temperature inside the control panel to increase due to heating
                                                                              resulting from the passage of electrical current through the load. To
SSR Mounting Pitch (Panel Mounting)                                           restrict heating, attach a fan to the ventilation outlet or air inlet of
                                                                              the control panel to ventilate the panel. This will reduce the ambient
             Duct                                                             temperature of the SSRs and thus increase reliability. (Generally,
                                                                              each 10 C reduction in temperature will double the expected life.)
                                                                60 mm min.
                                                                             Load current (A) 5 A 10 A 20 A 40 A 75 A 90 A
            Vertical direction                                              Required number 0.08 0.16 0.31 0.62 1.2 1.44
            30 mm min.                                                      of fans per SSR

80 mm min.                                                                  Example: For 10 SSRs with load currents of 10 A,
                                                                                         0.16 x 10 = 1.6
                                                                                         Thus, 2 fans would be required.

                                                                            Size of fans: 92 mm2, Air volume: 0.7 m3/min,
                                                                            Ambient temperature of control panel: 30 C

                                                                            If there are other instruments that generate heat in the control panel
                                                                            other than SSRs, additional ventilation will be required.

                                                                                                                                                                                              12
                                                                                                                                    G3NA

High-capacity Heat Sink (Y92B-                                                   Ratings and Characteristics of High-
P250NF)                                                                          capacity Heat Sink (Y92B-P250NF)

DIN-track Mounting                                                               Fan Ratings

Assembled DIN Tracks are heavy. Mount the DIN Tracks securely.                 Rated voltage      200 V
  Be sure that the Heat Sink is securely locked to the DIN Track.
                                                                                 Operating voltage  85% to 110% of rated voltage
Attach End Plates (PFP-M, order separately) to both ends of the
  Units on the DIN Track to hold them in place.                                  Frequency          50/60 Hz

To mount a Heat Sink to a DIN Track, press down at the point                   Rated current      0.061 A at 50 Hz
  indicated by arrow 1 in the diagram and then press in the Heat Sink            (See note.)        0.052 A at 60 Hz
  at the point indicated by arrow 2.
                                                                                 Rated speed        2,600 r/min at 50 Hz
                                                                                 (See note.)        3,050 r/min at 60 Hz

                                                                                 Note: Average values.

                                                                                 Thermostat Ratings

                                                                                 Operating temperature Approx. 90C

               Vertical                                                          Contact ratings           3 A at 240 VAC, resistive load
                                                                                                           3 A at 24 VDC, resistive load

                                                                                 Fan/Thermostat Characteristics

                                                                                 Motor type         Single-phase shading coil induction motor
                                                                                                    (2-pole, open type)

Applicable DIN Track                                                             Terminal type      Terminals

Mounting is possible on TE35-15Fe (IEC 60715) DIN tracks. DIN                    Insulation class   IEC class B (130C)
tracks from the following manufacturers can be used.                                                UL class A (105C)
                                                                                                    CSA class A (105C)

Manufacturer    Thickness: 1.5 mm    Thickness: 2.3 mm                          Insulation         100 M min. (at 500 VDC) between all power
Schneider      AM1-DE2000           ---                                          resistance         supply connections and uncharged metal parts.
WAGO           210-114 or 210-197   210-118
PHOENIX        N35/15               N35/15/15-2.3                                Insulation         2,000 VAC (1 minute) between all power supply

                                                                                 withstand voltage connections and uncharged metal parts.

Direct Mounting                                                                  Ambient operating -30 to 70C (no icing)
                                                                                 temperature
Prepare mounting holes as shown in the diagram.
  Tightening torque: 0.98 to 1.47 Nm                                             Ambient storage -40 to 85C (no icing)
                                                                                 temperature
                                                           640.3
                                                                                 Ambient humidity 25 to 85%

                                                                                 Protection         Impedance protection

                                                                                 Materials          Frame : Die-cast aluminum
                                                                                                    Blades : Glass polycarbonate

               1300.3                                                           Bearings           Ball bearings

                                                                                 Weight             Approx. 300 g

                                                                                 Compliant standards PSE, EN/IEC 60335 (CE marking compliant)

                                                                                 Certified standards UL/CSA (pending)

                                                     Four, 4.5 dia. or M4 holes   Use a commercial power supply (50/60 Hz) for the Fan.

When mounting a Heat Sink directly, first remove the Fan Unit, then             Be sure to turn OFF the power supply and wait for the blades to
  mount the Heat Sink by itself before attaching the Fan Unit again.               stop before inspecting the Fan.
  (Remove the two screws shown in the following diagram.)
                                                                                  High-precision ball bearings are used in the fan and these may be
                      Remove screws Fan Unit                                       damaged if the Fan is dropped or otherwise subjected to shock.
                                                                                   The life and characteristics of the Fan will be reduced if the
                                  Heat Sink                                        bearings are damaged. Do not subject the Fan to shock.

First, temporarily mount the Heat Sink with the bottom two screws               The life of the Fan depends on the ambient temperature, As a
  and then attach the top two screws with the mounting bracket                     guideline, the Fan life is 40,000 hours for continuous usage at
  sandwiched between the Heat Sink and mounting surface. Finally,                  40C.
  tighten all four screws.
                                                                                  Be sure there are no objects near the air vents that would restrict
                                                                                   air flow and no loose objects, such as electrical lines.

                                                                                  The Fan is an OMRON R87F-A4A-93HP (200 VAC) Fan. Use the
                                                                                   same model of Fan for replacement.

                                                                                  The recommended tightening torque for the Fan is 0.44 Nm.

                                                                                  Terminals equivalent to Faston #110 are used for the Fan power
                                                                                   supply terminals.

                                                                                  Refer to the following table for the OMRON Fan power supply plug
                                                                                   cables (order separately).

                                                                                   Cable     UL certified   Complies with Electrical Appliance
                                                                                  length                       and Material Safety Law (Japan)
                                                                                            R87F-PC
                                                                                 1m         R87F-PC-20     R87F-PCJT

                                                                                 2m                        R87F-PCJT-20

                                                                                  Connect the ground screw hole on the fan to PE.

                                                                                                                                                        13
                                                                                                                                                                       G3NA

Preventing Overheating with a High-                                                                                    2. DC-switching models

capacity Heat Sink (Y92B-P250NF)                                                                                       Less than 3 m                      Load
                                                                                                                                 Input G3NA-UTU Output
When the High-capacity Heat Sink is used, high-capacity switching
  at 75 A or 90 A requires forced cooling with a fan. Connect the Fan                                                   The input cable must be less than 3 m.
  to a power supply according to its ratings specifications.
                                                                                                                       Loss Time
If the Fan stops due to a power supply error, due to foreign matter
  in the power supply connection, or due to aging, the Heat Sink will                                                  The loss time will increase when the G3NA is used at a low applied
  heat to high temperatures, possibly resulting in failure of the SSR or                                               voltage or current. Be sure that this does not cause any problems.
  adverse affects on other devices. Implement an overheating
  prevention measure, such as turning OFF the load current, if the                                                                             Loss time
  Heat Sink overheats.
                                                                                                                       Using DC Loads
A thermostat is provided to detect overheating. The thermostat
  uses a NC contact, i.e., the circuit will be opened for overheating.                                                 For a DC or L load, a diode should be connected in parallel the load
  This thermostat can be used to stop the operation of the SSR.                                                        to absorb the counter electromotive force of the load.
  Implement an overheating prevention measure by using this signal
  to output an alarm or perform another response applicable to the                                                                                              Load
  system. Also, confirm that there is no problem with the overall
  system.

Do not connect the thermostat directly to the load power supply.
  Connect it to a contactor or other shutoff device connected above
  the SSR.

Terminals equivalent to Faston #187 are used for the thermostat
  terminals.

Do not place heat-dissipating silicon grease on the thermostat.

Do not solder the thermostat terminals.

The following diagram shows a protective circuit example.

                                                                         Circuit breaker                               Input          SSR                              Load power
                                                                         (contact side)                                                                                supply

      Circuit breaker                Y92B-P250NF                  Load
      (coil side)
                       Thermostat                                                                                      Fuses
Coil                   (NC contact)
power                                                                                                                  Connect a quick-break fuse in series with the load as a short-circuit
supply                               G3NA              Load side                                                       protection measure. Use one of the fuses in the following table or
                                                                                                                       one with equivalent or better characteristics.
Input side

                                                                                                              Circuit  Recommended Fuses
                                                                                                              breaker
                                                                                                                        G3NA rated     Fuse model        Manufacturer    Applicable SSR
Ventilating a High-capacity Heat Sink                                                                                   load current                                   G3NA-205B
(Y92B-P250NF)                                                                                                          5A             60LFF5       HINODE ELECTRIC     G3NA-210B
                                                                                                                       8A             60LFF8       CO.,LTD.            G3NA-220B
Refer to Ventilation Outside the Control Panel.                                                                      10 A           60LFF10                          G3NA-240B
                                                                                                                       15 A           60LFF15
Operating Conditions                                                                                                   20 A           60LFF20                          G3NA-275B-UTU
                                                                                                                                      50SHA20                          G3NA-290B-UTU
Do not apply currents exceeding the rated current otherwise, the                                                     25 A           60PFF25
  temperature of the G3NA may rise excessively.                                                                                       50SHA25
                                                                                                                       30 A           60PFF30
As protection against accidents due to short-circuiting, be sure to                                                                 50SHA30
  install protective devices, such as fuses and no-fuse breakers, on                                                   40 A           50SHA40
  the power supply side.                                                                                               45 A           50SHA45
                                                                                                                       50 A           50SHA50
Do not apply overvoltages to the input circuit or output circuit.                                                    75 A           50SHA75
  Failure or burning may result.                                                                                       80 A           50SHA80
                                                                                                                       100 A          50SHB100
Do not drop the G3NA or otherwise subject it to abnormal shock.
  Malfunction or failure may result.                                                                                   Reverse Connection

Keep the cooling system running continuously during the ON/OFF                                                       The output terminal side of the G3NA-D210B is connected to a built-
  operation of the SSR. This is to allow residual heat to dissipate                                                    in diode to protect the SSR from damage that may result from
  while the SSR is OFF. (load current 75 A, 90 A models)                                                               reverse connection. The SSR, however, cannot withstand one minute
                                                                                                                       or more if the wires are connected in reverse. Therefore, pay the
EMC Directive Compliance (For -UTU type)                                                                               utmost attention not to make polarity mistakes on the load side.

EMC direcives can be complied with under the following conditions.

1. AC-switching models

A capacitor must be connected to the input power supply.
A capacitor, varistor and toroidal core must be connected to the

  load power supply.
The input cable must be less than 3 m.

Input                  G3NA              Troidal core
                                         Load
                                     Output

3 m max.               Recommended Capacitor : 0.05F, 500 VAC (Load)
                                                           0.1F, 250 VAC (Input)

                       Recommended Varistor : 470 V, 1750 A
                       Recommended Troidal core : NEC/TOKIN:ESD-R-25B or equivalent

                                                                                                                                                                                              14
                                                                                                                G3NA

Precautions on Operating and Storage Environments

1. Operating Ambient Temperature                                                                    3. Vibration and Shock

The rated value for the ambient operating temperature of the G3NA                                   Do not subject the G3NA to excessive vibration or shock. Otherwise
is for when there is no heat build-up. For this reason, under                                       the G3NA may malfunction and internal components may be
conditions where heat dissipation is not good due to poor ventilation,                              deformed or damaged, resulting in failure of the G3NA to operate.
and where heat may build up easily, the actual temperature of the                                   To prevent the G3NA from abnormal vibration, do not install the
G3NA may exceed the rated value resulting in malfunction or                                         G3NA in locations or by means that will subject it to vibration from
burning.                                                                                            other devices, such as motors.

When using the G3NA, design the system to allow heat dissipation                                    4. Solvents
sufficient to stay below the Load Current vs. Ambient Temperature
characteristic curve. Note also that the ambient temperature of the                                 Do not allow the G3NA or the resin portion of the Fan's thermostat to
G3NA may increase as a result of environmental conditions (e.g.,                                    come in contact with solvents, such as thinners or gasoline. Doing so
climate or air-conditioning) and operating conditions (e.g., mounting                               will dissolve the markings on the G3NA.
in an airtight panel).
                                                                                                    5. Oil
2. Transportation
                                                                                                    Do not allow the G3NA terminal cover to come in contact with oil.
When transporting the G3NA, observe the following points. Not doing                                 Doing so will cause the cover to crack and become cloudy.
so may result in damage, malfunction, or deterioration of
performance characteristics.

Do not drop the G3NA or subject it to severe vibration or shock.
Do not transport the G3NA if it is wet.
Do not transport the G3NA under high temperatures or humidity.
Do not transport the G3NA without packing it properly.

Operation                                                                                          2. Screw Tightening Torque

1. Leakage Current                                                                                  Tighten the G3NA terminal screws properly. If the screws are not
                                                                                                    tight, the G3NA will be damaged by heat generated when the power
A leakage current flows through a snubber circuit in the G3NA even                                  is ON. Perform wiring using the specified tightening torque.
when there is no power input. Therefore, always turn OFF the power
to the input or load and check that it is safe before replacing or wiring                           3. Handling Relays
the G3NA.
                                                                                                    Do not mount the G3NA when your hands are oily or dirty, e.g., with
                                     Switch element Snubber circuit                                 metal powder. These may cause G3NA failure.

                                                                                   Leakage current  4. Do Not Drop
Input circuit
        Trigger circuit                                                                             Be careful not to drop a Relay or Heat Sink onto any part of your
                                                                                                    body while working. Injury may result. This is particularly true for the
                                                     Varistor                                       High-capacity Heat Sink (Y92B-P250NF), which weighs 2.5 kg.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                  In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                15
                                                       Read and Understand This Catalog

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

                                                      Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

                                                            Application Considerations

SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

       Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

       Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
           safety equipment, and installations subject to separate industry or government regulations.

       Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

                                                                       Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

OMRON Corporation                                                                                                                                      2010.10
                               In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
                                                                                   (c)Copyright OMRON Corporation 2010 All Right Reserved.
http://www.ia.omron.com/
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved