电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

Y92A-48G

器件型号:Y92A-48G
器件类别:热门应用    机电/工控/自动化   
文件大小:65135.05KB,共11页
厂商名称:All Sensors
标准:
下载文档

器件描述

控制器 p3g/p3gA terminal cover

参数
制造商: Omron
产品种类: 控制器
RoHS:

Y92A-48G器件文档内容

Digital Temperature Controllers/Digital Controllers

E5@N/E5@N-H

Upgraded 1/16, 1/8, and 1/4 DIN Controllers, the Best-selling E5@N Series.
Basic Type (Renewal E5@N) and Advanced Type (New E5@N-H).

Improved indication accuracy and preventive maintenance (Basic Type E5@N).
New high-performance Controllers (Advanced Type E5@N-H).
Easy-to-use one-touch operation with PF Key (Only for 1/8 and 1/4 DIN).
Logic operations.

                                             E5@N Series

Basic Type (Renewal E5@N)   Advanced Type (New E5@N-H)

E5CN      E5EN     E5AN     E5CN-H    E5EN-H   E5AN-H

1/16 DIN  1/8 DIN  1/4 DIN  1/16 DIN  1/8 DIN  1/4 DIN

                                                                              1
                        Contents

   Digital Temperature Controllers

   E5CN/E5CN-U .............................................          3

   E5AN/E5EN .................................................        17

   Digital Controllers

   E5CN-H........................................................     31

   E5AN-H/E5EN-H..........................................            43

   Operation Procedure

    Operation .....................................................  58

   Common to All Controllers

    Safety Precautions .......................................       66

   CX-Thermo Support Software

    EST2-2C-MV4..............................................        70

2
Basic-type Digital Temperature Controller                                                                                                 E5CN
                                                                                                                                             E5CN-U (48 x 48 mm)
E5CN/E5CN-U (48 x 48 mm)

New 48 x 48-mm Basic Temperature                                                                                                          E5AN (96 x 96 mm)
Controller with Enhanced Functions and                                                                                                       E5EN (48 x 96 mm)
Performance. Improved Indication
Accuracy and Preventive Maintenance                                                  48 48-mm    48 48-mm
Function.                                                                                E5CN        E5CN-U

Indication Accuracy                                                                            Refer to Safety Precautions on page 66.       E5CN-H (48 x 48 mm)
  Thermocouple input: 0.3% of PV (previous models: 0.5%)
  Pt input: 0.2% of PV (previous models: 0.5%)
  Analog input: 0.2% FS (previous models: 0.5%)

New E5CN-U Models (Plug-in Models) with analog inputs and
  current outputs.

A PV/SV-status display function can be set to automatically
  alternate between displaying the status of the Temperature
  Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV.

Preventive maintenance for relays in the Temperature Controller
  using a Control Output ON/OFF Counter.

Main I/O Functions

                                   Event Inputs  E5CN                                                                                     E5AN-H (96 x 96 mm)
                                    None                                                                                                    E5EN-H (48 x 96 mm)
                                    Two               2-level Display: PV and SV 4-digit Display

Sensor Inputs                                    Control Output 2    Auxiliary Outputs   Auto/manual switching
Universal thermocouple/Pt inputs                None               None             Temperature Controller status display
                                                 Voltage output    One               Simple program function
(Models with temperature inputs)                                     Two               Control output ON/OFF count alarm
Analog current/voltage inputs                   (for driving SSR)                      PV change rate alarm
                                                                                        Models also available with RS-485                    Operation
(Models with analog inputs)
                                                                                         communications
Indication Accuracy
Thermocouple input: 0.3% of PV                Control Output 1
Pt input: 0.2% of PV                           Relay output
Analog input: 0.2% FS                         Voltage output (for driving SSR)
                                                 Current output
Sampling Period                                  Long-life relay output (hybrid)
250 ms

This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions  Safety Precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)

                                                                                3
E5CN                    E5CN/E5CN-U
   E5CN-U (48 x 48 mm)
                        Lineup

                                                                                                          1 control output   0 or 2 auxiliary outputs

                                                                                       Temperature input  2 control outputs 2 auxiliary outputs

                                     Terminal block                                       Analog input    1 control output   0 or 2 auxiliary outputs
                                         Plug-in                                       Temperature input
                        E5CN                                                                              2 control outputs  2 auxiliary outputs
                                                                                          Analog input    1 control output
                        Basic Type                                                                        1 control output   0, 1, or 2 auxiliary
                                                                                                                             outputs
E5AN (96 x 96 mm)
   E5EN (48 x 96 mm)                                                                                                         0, 1, or 2 auxiliary
                                                                                                                             outputs

                        Note: Models with one control output and one or two auxiliary outputs and models with two control outputs can be used for heating/cooling control.

                        Model Number Structure

E5CN-H (48 x 48 mm)     Model Number Legend                                            Option Units

E5AN-H (96 x 96 mm)     Controllers                                                    E53-CN@@@
   E5EN-H (48 x 96 mm)
                        E5CN-@@M@@-@-500                                                           1 234
Operation
                                       12345 6 7                                       1. Applicable Controller
                                                                                           CN: E5CN or E5CN-H
                        1. Control Output 1
                            R: Relay output                                            2. Function 1
                            Q: Voltage output (for driving SSR)                            Blank: None
                            C: Current output                                              Q: Control output 2 (voltage for driving SSR)
                            Y: Long-life relay output (hybrid) 1                           P: Power supply for sensor

                        2. Auxiliary Outputs 2                                         3. Function 2
                            Blank: None                                                    Blank: None
                            2: Two outputs                                                 H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
                                                                                           HH: Heater burnout/SSR failure/Heater overcurrent detection
                        3. Option                                                                (CT2)
                            M: Option Unit can be mounted.                                 B: Two event inputs
                                                                                           03: RS-485 communications
                        4. Input Type                                                      H03: Heater burnout/SSR failure/Heater overcurrent detection
                            T: Universal thermocouple/platinum resistance thermometer             (CT1) + RS-485 communications
                            L: Analog current/voltage input                                HB: Heater burnout/SSR failure/Heater overcurrent detection
                                                                                                 (CT1) + Two event inputs
                        5. Power Supply Voltage                                            HH03: Heater burnout/SSR failure/Heater overcurrent detection
                            Blank: 100 to 240 VAC                                                   (CT2) + RS-485 communications
                            D: 24 VAC/VDC
                                                                                       4. Version
                        6. Case Color                                                      N2: Applicable only to models released after January 2008
                            Blank: Black
                            W: Silver

                        7. Terminal Cover
                            -500: With terminal cover

Safety Precautions      Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).
                        1. Always connect an AC load to a long-life relay output. The output will not turn OFF if a DC load is connected because a triac is used for

                             switching the circuit. For details, check the conditions in Ratings.
                        2. Auxiliary outputs are contact outputs that can be used to output alarms or results of logic operations.

                     4
                                                                                                                         E5CN/E5CN-U

Ordering Information                                                                                                                                 E5CN
                                                                                                                                                        E5CN-U (48 x 48 mm)
Controllers with Terminal Blocks

Size            Case color  Power supply    Input type                Auxiliary outputs                Control output 1                       Model
                                voltage
                                                                                                                                  E5CN-RMT-500
                                                     Thermocouple or  None               Relay output                             E5CN-QMT-500
                            100 to 240 VAC Resistance                 2                  Voltage output (for driving SSR)         E5CN-CMT-500
                                                                      None               Current output                           E5CN-R2MT-500
                                                     thermometer      2                  Relay output                             E5CN-Q2MT-500
                                                                      None               Voltage output (for driving SSR)         E5CN-C2MT-500
                            24 VAC/VDC      Thermocouple or           2                  Current output                           E5CN-Y2MT-500      E5AN (96 x 96 mm)
                                            Resistance                2                  Long-life relay output (hybrid)          E5CN-RMTD-500         E5EN (48 x 96 mm)
                                            thermometer               None               Relay output                             E5CN-QMTD-500
                                                                      2                  Voltage output (for driving SSR)         E5CN-CMTD-500
              Black                                                   2                  Current output                           E5CN-R2MTD-500
                                                                                         Relay output                             E5CN-Q2MTD-500
1/16 DIN                    100 to 240 VAC  Analog                                       Voltage output (for driving SSR)         E5CN-C2MTD-500
                                            (current/voltage)                            Current output                           E5CN-RML-500
48 48 78                                                                             Relay output                             E5CN-QML-500
(W H D)                                                                              Voltage output (for driving SSR)         E5CN-CML-500          E5CN-H (48 x 48 mm)
                                                                                         Current output                           E5CN-R2ML-500
                            24 VAC/VDC      Analog                                       Relay output                             E5CN-Q2ML-500
                                            (current/voltage)                            Voltage output (for driving SSR)         E5CN-C2ML-500
                                                                                         Current output                           E5CN-Y2ML-500
                            100 to 240 VAC                                               Long-life relay output (hybrid)          E5CN-R2MLD-500
                                                                                         Relay output                             E5CN-Q2MLD-500
              Silver                        Thermocouple or                              Voltage output (for driving SSR)         E5CN-C2MLD-500     E5AN-H (96 x 96 mm)
                                            Resistance                                   Current output                           E5CN-RMT-W-500        E5EN-H (48 x 96 mm)
                                            thermometer                                  Relay output                             E5CN-QMT-W-500
                                                                                         Voltage output (for driving SSR)         E5CN-CMT-W-500
                            24 VAC/VDC                                                   Current output                           E5CN-R2MT-W-500
                                                                                         Relay output                             E5CN-Q2MT-W-500
                                                                                         Voltage output (for driving SSR)         E5CN-C2MT-W-500
                                                                                         Current output                           E5CN-Y2MT-W-500
                                                                                         Long-life relay output (hybrid)          E5CN-R2MTD-W-500
                                                                                         Relay output                             E5CN-Q2MTD-W-500
                                                                                         Voltage output (for driving SSR)         E5CN-C2MTD-W-500
                                                                                         Current output

Option Units

One of the following Option Units can be mounted to provide the E5CN with additional functions.

                                                     Functions                                                                            Model
                                                                                                                                  E53-CNHH03N2
Communications  3-phase heater burnout/SSR failure/  Event inputs                                                                 E53-CNHBN2            Operation
RS-485          Heater overcurrent detection         Event inputs                                                                 E53-CNQ03N2
                                                                                                                                  E53-CNPBN2
Communications  Heater burnout/SSR failure/Heater                                                                                 E53-CNPHN2
RS-485          overcurrent detection                                                                                             E53-CNP03N2
                                                                                                                                  E53-CNH03N2
                                                                            Control output 2                                      E53-CN03N2
                                                                            (Voltage for driving SSR)                             E53-CNBN2
                                                                                                                                  E53-CNQHN2
Communications  Heater burnout/SSR failure/Heater                                                      External power supply for  E53-CNQHHN2
RS-485          overcurrent detection                                                                  ES1B                       E53-CNQBN2

Communications  Heater burnout/SSR failure/Heater                                                      External power supply for
RS-485          overcurrent detection                                                                  ES1B

Communications                                                                                         External power supply for
RS-485                                                                                                 ES1B

                Heater burnout/SSR failure/Heater    Event inputs           Control output 2                                                            Safety Precautions
                overcurrent detection                Event inputs           (Voltage for driving SSR)

                3-phase heater burnout/SSR failure/                         Control output 2
                Heater overcurrent detection                                (Voltage for driving SSR)

                                                                            Control output 2
                                                                            (Voltage for driving SSR)

Note: Option Units cannot be used for plug-in models.
        These Option Units are applicable only to models released after January 2008.

                                                                                                                                                     5
E5CN                    E5CN/E5CN-U
   E5CN-U (48 x 48 mm)
                        Model Number Structure

                        Model Number Legend (Plug-in-type Controllers)

                        E5CN-@@@U                                                      3. Input Type
                                                                                           T: Universal thermocouple/platinum resistance thermometer
                                       1234                                                L: Analog Input

                        1. Output Type                                                 4. Plug-in type
                            R: Relay output                                                U: Plug-in type
                            Q: Voltage output (for driving SSR)
E5AN (96 x 96 mm)           C: Current output
   E5EN (48 x 96 mm)
                        2. Number of Alarms
                            Blank: No alarm
                            1: One alarm
                            2: Two alarms

                        Ordering Information

                        Plug-in-type Controllers

                              Size  Case color Power supply voltage Input type Auxiliary outputs  Control output 1  Model
                        1/16 DIN
                                                                                                  Relay output      E5CN-RTU

                                                                                    None          Voltage output (for driving SSR) E5CN-QTU

E5CN-H (48 x 48 mm)                                                                               Current output    E5CN-CTU

                                                                 Thermocouple                     Relay output      E5CN-R1TU
                                                                 or resistance 1
                                                                 thermometer                      Voltage output (for driving SSR) E5CN-Q1TU

                                                                                                  Current output    E5CN-C1TU

                                                                                                  Relay output      E5CN-R2TU

                                           100 to 240 VAC                           2             Voltage output (for driving SSR) E5CN-Q2TU

                                                                                                  Current output    E5CN-C2TU

                                                                                                  Relay output      E5CN-R1LU

                                                                                    1             Voltage output (for driving SSR) E5CN-Q1LU

E5AN-H (96 x 96 mm)                 Black                        Analog                           Current output    E5CN-C1LU
   E5EN-H (48 x 96 mm)                                           (current/voltage)                Relay output      E5CN-R2LU

                                                                                    2             Voltage output (for driving SSR) E5CN-Q2LU

                                                                                                  Current output    E5CN-C2LU

                                                                                                  Relay output      E5CN-RTDU

                                                                                    None          Voltage output (for driving SSR) E5CN-QTDU

                                                                                                  Current output    E5CN-CTDU

                                                                 Thermocouple                     Relay output      E5CN-R1TDU
                                                                 or resistance 1
                                           24 VAC/VDC            thermometer                      Voltage output (for driving SSR) E5CN-Q1TDU

                                                                                                  Current output    E5CN-C1TDU

                                                                                                  Relay output      E5CN-R2TDU

                                                                                    2             Voltage output (for driving SSR) E5CN-Q2TDU

Operation                                                                                         Current output    E5CN-C2TDU

Safety Precautions

                     6
                                                                                              E5CN/E5CN-U

Accessories (Order Separately)                                         Adapter                                                             E5CN
                                                                                                                                              E5CN-U (48 x 48 mm)
USB-Serial Conversion Cable

                       Model                                           Connectable models           Model
                    E58-CIFQ1                                          Terminal block models       Y92F-45

Terminal Cover                                                         Note: Use this Adapter when the panel has been previously prepared
                                                                               for the E5B@.
Connectable models  Terminal block models
Model               E53-COV17                                          Sockets (for Plug-in Models)

Note: The Terminal Cover comes with the E5CN-@@@-500 models.                                       Type                   Model
                                                                       Front-connecting Socket                         P2CF-11
Waterproof Packing                                                     Front-connecting Socket with Finger Protection  P2CF-11-E
                                                                       Back-connecting Socket                          P3GA-11
                                         Model                         Terminal Cover for Back-connecting socket with                      E5AN (96 x 96 mm)
                                        Y92S-29                        Finger Protection                               Y92A-48G               E5EN (48 x 96 mm)

Note: The Waterproof Packing is included with the Controller only for  CX-Thermo Support Software
        models with terminal blocks.
                                                                                     Model
Current Transformers (CTs)                                                      EST2-2C-MV4

Hole diameter                   Model
     5.8 dia.                  E54-CT1
    12.0 dia.                  E54-CT3

                                                                                                                                              E5CN-H (48 x 48 mm)

                                                                                                                                           E5AN-H (96 x 96 mm)
                                                                                                                                              E5EN-H (48 x 96 mm)

                                                                                                                                              Operation

                                                                                                                                              Safety Precautions

                                                                                                                                           7
E5CN                    E5CN/E5CN-U
   E5CN-U (48 x 48 mm)
                        Specifications

                        Ratings

                        Power supply voltage         No D in model number: 100 to 240 VAC, 50/60 Hz
                                                     D in model number: 24 VAC, 50/60 Hz; 24 VDC

                        Operating voltage range      85% to 110% of rated supply voltage

                        Power      E5CN              100 to 240 VAC: 7.5 VA (max.) (E5CN-R2T at 100 VAC: 3.0 VA)
                        consump-   E5CN-U            24 VAC/VDC: 5 VA/3 W (max.) (E5CN-R2TD at 24 VAC: 2.7 VA)
                        tion
                                                     100 to 240 VAC: 6 VA (max.)
                                                     24 VAC/VDC: 3 VA/2 W (max.) (models with current output: 4 VA/2 W)

E5AN (96 x 96 mm)       Sensor input                 Models with temperature inputs
   E5EN (48 x 96 mm)                                   Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                                                       Platinum resistance thermometer: Pt100 or JPt100
                                                       Infrared temperature sensor: 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
                                                       Voltage input: 0 to 50 mV

                                                     Models with analog inputs
                                                       Current input: 4 to 20 mA or 0 to 20 mA
                                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

                        Input impedance              Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB.)

                        Control method               ON/OFF control or 2-PID control (with auto-tuning)

                                   Relay output      E5CN    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
                                                     E5CN-U  load: 5 V, 10 mA
E5CN-H (48 x 48 mm)
                                                             SPDT, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load:
                                                             5 V, 10 mA

                        Control    Voltage output    E5CN Output voltage: 12 VDC 15% (PNP), max. load current: 21 mA, with short-circuit protection
                        outputs
                                   (for driving SSR) E5CN-U circuit

                                   Current output    E5CN 4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 10,000

                                   Long-life relay   E5CN    SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply
                                   output                    voltage: 75 to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA,
                                                             leakage current: 5 mA max. (250 VAC, 60 Hz)

                        Auxiliary  Number of outputs 1 or 2 max. (Depends on the model.)
                        outputs
                                   Output specifica- Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum

                                   tions             applicable load: 5 V, 10 mA

                                   Number of inputs 2

E5AN-H (96 x 96 mm)     Event      External contact  Contact input: ON: 1 k max., OFF: 100 k min.
   E5EN-H (48 x 96 mm)  inputs     input specifica-  Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
                                   tions             Current flow: Approx. 7 mA per contact

                        External power supply for ES1B 12 VDC 10%, 20 mA, short-circuit protection circuit provided

                        Setting method               Digital setting using front panel keys

                        Indication method            11-segment digital display and individual indicators (7-segment display also possible)
                                                     Character height: PV: 11 mm, SV: 6.5 mm

                        Multi SP                     Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial
                                                     communications.

                        Bank switching               Not supported

Operation               Other functions              Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
                                                     detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
                                                     protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic
                                                     operations, PV/SV status display, simple program, automatic cooling coefficient adjustment

                        Ambient operating temperature -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C

                        Ambient operating humidity   25% to 85%

                        Storage temperature          -25 to 65C (with no condensation or icing)

Safety Precautions

                     8
                                                                                                                                                                                  E5CN/E5CN-U

Input Ranges                                                                                                                                                                                                         E5CN
                                                                                                                                                                                                                        E5CN-U (48 x 48 mm)
Thermocouple/Platinum Resistance Thermometer (Universal Inputs)

Input                           Platinum resistance                                                    Thermocouple                                                               Infrared temperature    Analog
Type                                 thermometer                                                                                                                                           sensor           input
                                                                                                                                                                                                             0 to
Name                                   Pt100         JPt100               K           J        T       EL                 U       N      R  S  B    W                       PL    10 to  60 to  115  140   50 mV
                                                                                                                                                                             II   70C           to   to
                                                                                                                                                                                          120   165  260  Usable
                                                                                                                                                                                          C    C   C   in the
                                                                                                                                                                                                          following
                        2300                                                                                                                                          2300                                ranges
                        1800                                                                                                                                1800                                          by
                        1700                                                                                                             1700 1700                                                        scaling:
                                                                                                                                                                                                          -1999 to
                        1600                                                                                                                                                                              9999 or
                                                                                                                                                                                                          -199.9
                        1500                                                                                                                                                                              to 999.9

                        1400                                        1300                                                          1300                                      1300                              23     E5AN (96 x 96 mm)
                        1300                                                                                                                                                                                            E5EN (48 x 96 mm)
Temperature range (C)
                        1200

                        1100

                        1000                                                     850                             850
                                  850

                         900

                        800

                        700                                                                            600

                        600            500.0         500.0                500.0

                        500                                                           400.0 400 400.0                  400 400.0

                        400                                                                                                                                                                          260

                        300                                                                                                                                                              120 165

                        200                   100.0          100.0                                                                                                                90

                        100                                                                                                                    100                                                                      E5CN-H (48 x 48 mm)

                        0                     0.0            0.0                                                                         0  0       0                       0     0      0      0    0

                        -100.0                                            -20.0 -100 -20.0                       -100

                        -200.0  -200 -199.9          -199.9         -200                       -200 -199.9 -200        -200 -199.9 -200

Setting                         0      1      2      3       4      5        6   7          8  9 10 11 12 13 14 15 16 17 18 24 25 19 20 21 22
number

Shaded settings are the default settings.                                                                              JPt100: JIS C 1604-1989, JIS C 1606-1989
The applicable standards for the input types are as follows:                                                           Pt100: JIS C 1604-1997, IEC 751
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1                                                                     PL II: According to Platinel II electromotive force charts from BASF (previously
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985                                                                                                     Engelhard)
W: W5Re/W26Re, ASTM E988-1990

Models with Analog Inputs                                                                                                                                                                                            E5AN-H (96 x 96 mm)
                                                                                                                                                                                                                        E5EN-H (48 x 96 mm)
                        Input Type                           Current                                   Voltage

Input specification 4 to 20mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V

Setting range                                    Usable in the following ranges by scaling:
                                                 -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or -1.999 to 9.999

Setting number 0                                                    1                    2        3                    4

Shaded settings are the default settings.

                                                                                                                                                                                                                        Operation

                                                                                                                                                                                                                        Safety Precautions

                                                                                                                                                                                                                     9
                        E5CN/E5CN-U

E5CN                    Alarm Outputs
   E5CN-U (48 x 48 mm)
                        Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
                        Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

                        Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
                                following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
                                failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).

                         Set                            Alarm output operation                     1. With set values 1, 4 and 5, the upper and lower limit values can
                        value                                                                           be set independently for each alarm type, and are expressed as
                               Alarm type               When X is               When X is               "L" and "H."
                                                         positive                negative
                                                                                                   2. Set value: 1, Upper- and lower-limit alarm

E5AN (96 x 96 mm)       0      Alarm function      Output OFF                                      Case 1          Case 2           Case 3 (Always ON)
   E5EN (48 x 96 mm)           OFF
                                                                                                                                                                                               H < 0, L < 0
                        1 Upper- and lower- ON             LH                                          L H SP      SP L H             H SP L
                                                                                                                                    H L SP                                                     H < 0, L > 0
                        1 limit                    OFF                     2                       H < 0, L > 0    H > 0, L < 0                                                                H  L
                                                                       SP                          H < L           H > L                                                                       H > 0, L < 0
                                                                                                                                                                                               H  L
                                                   ON          X           ON   X
                                                   OFF     SP
                        2 Upper limit                                      OFF                                                                                                         SP H L
                                                                                               SP
                                                                                                   3. Set value: 4, Upper- and lower-limit range
                                                           X                        X
                                                   ON                      ON   SP
                        3 Lower limit                                      OFF
                                                   OFF                                             Case 1          Case 2           Case 3 (Always OFF)
                                                                       SP                                                                  H SP L
                                                                                                          L H SP     SP L H
                        4 Upper- and lower- ON             LH                                        H < 0, L > 0     H > 0, L < 0      H L SP                                                 H < 0, L < 0
                                                                                                      H < L           H > L
                        1 limit range              OFF                     3                                                                                                                   H < 0, L > 0
                                                                       SP                                                                                                                      H  L

E5CN-H (48 x 48 mm)     5      Upper- and lower- ON        LH              4                                                                                                                   H > 0, L < 0
                               limit with standby OFF       SP                                                                                                                                 H  L
                        1
                               sequence            5                                                                                SP H L

                               Upper-limit with    ON          X           ON   X                  4. Set value: 5, Upper- and lower-limit with standby sequence
                                                           SP                                           For Upper- and Lower-Limit Alarm Described Above
                        6      standby sequence OFF                        OFF
                                                                                               SP

                        7      Lower-limit with    ON      X               ON       X               Case 1 and 2
                                                            SP             OFF  SP                  Always OFF when the upper-limit and lower-limit hysteresis
                               standby sequence OFF                                                 overlaps.

                        8      Absolute-value      ON        X             ON      X                Case 3: Always OFF
                               upper-limit         OFF  0                  OFF          0

                        9      Absolute-value      ON        X             ON      X               5. Set value: 5, Upper- and lower-limit with standby sequence
                               lower-limit         OFF  0                  OFF          0               Always OFF when the upper-limit and lower-limit hysteresis
                                                                                                        overlaps.

E5AN-H (96 x 96 mm)            Absolute-value      ON         X            ON      X
   E5EN-H (48 x 96 mm)                             OFF                     OFF          0
                        10 upper-limit with

                               standby sequence         0

                               Absolute-value      ON         X            ON      X
                                                   OFF                     OFF          0
                        11 lower-limit with

                               standby sequence         0

                        12     LBA                 ---
                               (for alarm 1 only)

                        13     PV change rate      ---
                               alarm

Operation

Safety Precautions

10
                                                                                                             E5CN/E5CN-U

Characteristics                                                                                                                                                E5CN
                                                                                                                                                                  E5CN-U (48 x 48 mm)
Indication accuracy         Thermocouple: 1
                              Terminal block models (E5CN): (0.3% of indicated value or 1C, whichever is greater) 1 digit max.
                              Plug-in models (E5CN-U): (1% of indicated value or 2C, whichever is greater) 1 digit max.

                            Platinum resistance thermometer input:
                              Terminal block models (E5CN) and plug-in models (E5CN-U): (0.2% of indicated value or 0.8C, whichever is greater)

                            1 digit max.
                            Analog input:

                              Terminal block models (E5CN) and plug-in models (E5CN-U): 0.2% FS 1 digit max.
                            CT input:

                              Terminal block models (E5CN): 5% FS 1 digit max.

Influence of temperature 2  Thermocouple input (R, S, B, W, PL II):                                                                                            E5AN (96 x 96 mm)
Influence of voltage 2        Terminal block models (E5CN): (1% of PV or 10C, whichever is greater) 1 digit max.                                              E5EN (48 x 96 mm)
                              Plug-in models (E5CN-U): (2% of PV or 10C, whichever is greater) 1 digit max.

                            Other thermocouple input: 3
                              Terminal block models (E5CN): (1% of PV or 4C, whichever is greater) 1 digit max.
                              Plug-in models (E5CN-U): (2% of PV or 4C, whichever is greater) 1 digit max.

                            Platinum resistance thermometer input:

                              Terminal block models (E5CN) and plug-in models (E5CN-U):
                              (1% of PV or 2C, whichever is greater) 1 digit max.
                            Analog input:
                              Terminal block models (E5CN) and plug-in models (E5CN-U): (1%FS) 1 digit max.

Input sampling period       250 ms

Hysteresis                  Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) 4
                            Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS)

Proportional band (P)       Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1 EU) 4
                            Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
                                                                                                                                                               E5CN-H (48 x 48 mm)
Integral time (I)           0 to 3999 s (in units of 1 s)

Derivative time (D)         0 to 3999 s (in units of 1 s) 5

Control period              0.5, 1 to 99 s (in units of 1 s)

Manual reset value          0.0 to 100.0% (in units of 0.1%)

Alarm setting range         -1999 to 9999 (decimal point position depends on input type)

Affect of signal source resis- Thermocouple: 0.1C/ max. (100  max.)

tance                       Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance       20 M min. (at 500 VDC)

Dielectric strength         2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

Vibration   Malfunction     10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions                                                                     E5AN-H (96 x 96 mm)
resistance  Destruction     10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions                                                        E5EN-H (48 x 96 mm)

Shock       Malfunction     100 m/s2, 3 times each in X, Y, and Z directions
resistance  Destruction     300 m/s2, 3 times each in X, Y, and Z directions

Weight      E5CN            Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g
            E5CN-U          Controller: Approx. 110 g, Mounting Bracket: Approx. 10 g

Degree of   E5CN            Front panel: IP66, Rear case: IP20, Terminals: IP00
protection  E5CN-U          Front panel: IP50, Rear case: IP20, Terminals: IP00

Memory protection           Non-volatile memory (number of writes: 1,000,000 times)

Setup Tool                  CX-Thermo version 4.0 or higher

Setup Tool port             Provided on the bottom of the E5CN. Use this port to connect a computer to the E5CN when using the Setup Tool. An
                            E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5CN. 6

Standards   Approved        UL 61010-1, CSA C22.2 No. 1010-1                                                                                                   Operation
            standards 7     EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II

            Conformed
            standards

                            EMI:                                                 EN 61326

                            Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                            Noise Terminal Voltage:                              EN 55011 Group 1, class A

                            EMS:                                                 EN 61326

                            ESD Immunity:                                        EN 61000-4-2

EMC                         Electromagnetic Field Immunity:                      EN 61000-4-3

                            Burst Noise Immunity:                                EN 61000-4-4

                            Conducted Disturbance Immunity:                      EN 61000-4-6

                            Surge Immunity:                                      EN 61000-4-5                                                                  Safety Precautions

                            Power Frequency Magnetic Field Immunity:             EN 61000-4-8

                            Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U and L
     thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max. is not specified.
     The indication accuracy of B thermocouples in the 400 to 800C range is 3C max. The indication accuracy of the R and S thermocouples at a temperature
     of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is 0.3 of PV or 3C, whichever is greater, 1 digit max. The indication
     accuracy of PL II thermocouples is 0.3 of PV or 2C, whichever is greater, 1 digit max.

2. Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
3. K thermocouple at -100C max.: 10 max.
4. "EU" stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is C or F.
5. When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s).
6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time.
7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket.

     The P3GA-11 is not certified for UL listing.

                                                                                                                                                    11
                        E5CN/E5CN-U

E5CN                    USB-Serial Conversion Cable                                                Current Transformer (Order Separately)
   E5CN-U (48 x 48 mm)                                                                             Ratings
                        Applicable OS        Windows 2000, XP, or Vista

                        Applicable software  Thermo Mini, CX-Thermo version 4.0 or                 Dielectric strength 1,000 VAC for 1 min
                                             higher
                                                                                                   Vibration resistance 50 Hz, 98 m/s2

                        Applicable models    E5AN/E5EN/E5CN/E5CN-U/E5AN-H/                         Weight                                             E54-CT1: Approx. 11.5 g, E54-CT3: Approx.
                                             E5EN-H/E5CN-H                                                                                            50 g

                        USB interface standard Conforms to USB Specification 1.1.                  Accessories                                        Armatures (2)
                                                                                                   (E54-CT3 only)                                     Plugs (2)
                        DTE speed            38400 bps

E5AN (96 x 96 mm)       Connector            Computer: USB (type A plug)                           Heater Burnout Alarms, SSR Failure
   E5EN (48 x 96 mm)    specifications       Temperature Controller: Setup Tool port               Alarms, and Heater Overcurrent Alarms
                                             (on bottom of Controller)

                        Power supply         Bus power (Supplied from USB host                     CT input                                              Models with detection for single-phase
                                             controller.)                                          (for heater current de-                               heaters: One input
                                                                                                   tection)                                              Models with detection for single-phase
                        Power supply voltage 5 VDC                                                                                                       or three-phase heaters: Two inputs

                        Current consumption 70 mA

                        Ambient operating    0 to 55C (with no condensation or icing)             Maximum heater current 50 A AC
                        temperature
                                                                                                   Input current indication                              5% FS 1 digit max.
                        Ambient operating                                                          accuracy
                        humidity
                                             10% to 80%                                            Heater burnout alarm                                  0.1 to 49.9 A (in units of 0.1 A)
                                                                                                   setting range 1                                       Minimum detection ON time: 100 ms
                                             -20 to 60C (with no condensation or
E5CN-H (48 x 48 mm)     Storage temperature  icing)                                                SSR failure alarm set- 0.1 to 49.9 A (in units of 0.1 A)

                        Storage humidity     10% to 80%                                            ting range 2                                          Minimum detection OFF time: 100 ms

                        Altitude             2,000 m max.                                          Heater overcurrent                                    0.1 to 49.9 A (in units of 0.1 A)

                                                                                                   alarm setting range 3 Minimum detection ON time: 100 ms

                        Weight               Approx. 100 g                                         1. For heater burnout alarms, the heater current will be measured
                                                                                                        when the control output is ON, and the output assigned to the
                        Note: A driver must be installed in the personal computer. Refer to             alarm 1 function will turn ON if the heater current is lower than the
                                installation information in the operation manual for the                set value (i.e., heater burnout detection current value).
                                Conversion Cable.
                                                                                                   2. For SSR failure alarms, the heater current will be measured when
                        Communications Specifications                                                   the control output is OFF, and the output assigned to the alarm 1
                                                                                                        function will turn ON if the heater current is higher than the set
E5AN-H (96 x 96 mm)     Transmission line    RS-485: Multipoint                                         value (i.e., SSR failure detection current value).
   E5EN-H (48 x 96 mm)  connection method
                                                                                                   3. For heater overcurrent alarms, the heater current will be
                        Communications RS-485 (two-wire, half duplex)                                   measured when the control output is ON, and the output assigned
                                                                                                        to the alarm 1 function will turn ON if the heater current is higher
                        Synchronization      Start-stop synchronization                                 than the set value (i.e., heater overcurrent detection current
                        method                                                                          value).

                        Protocol             CompoWay/F, SYSWAY, or Modbus

                        Baud rate            1200, 2400, 4800, 9600, 19200, 38400, or              Electrical Life Expectancy Curve for
                                             57600 bps                                             Relays (Reference Values)

                        Transmission code ASCII

                        Data bit length  7 or 8 bits                                               Life ( 104 operations)  500
                                                                                                                            300
                        Stop bit length  1 or 2 bits

Operation               Error detection      Vertical parity (none, even, odd)                                              100
                                             Frame check sequence (FCS) with SYSWAY
                                             Block check character (BCC) with                                                50
                                             CompoWay/F or CRC-16 Modbus                                                     30

                        Flow control         None

                        Interface            RS-485                                                                         10

                        Retry function       None

                        Communications                                                                                      5       E5CN
                        buffer
                                             217 bytes                                                                      3       250 VAC, 30 VDC

                                                                                                                                    (resistive load)

                        Communications 0 to 99 ms                                                                                   cos = 1
                        response wait time Default: 20 ms
Safety Precautions                                                                                                          1

                                                                                                                                 0  1        2        3  4  5        6

                         The baud rate, data bit length, stop bit length, and vertical parity can                                                        Switching current (A)
                          be individually set using the Communications Setting Level.
                                                                                                   Note: Do not connect a DC load to a Controller with a Long-life Relay
                                                                                                           Output.

12
                                                                                                                                                              E5CN/E5CN-U

External Connections                                                                                                                                                                     E5CN
                                                                                                                                                                                            E5CN-U (48 x 48 mm)
A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,
  do not connect any of the control output terminals to ground. (If the control output terminals are connected to ground, errors will occur in the
  measured temperature values as a result of leakage current.)

Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose.

E5CN

Controllers

                    Control output 1                                +                                           Auxiliary outputs (relay outputs)                                        E5AN (96 x 96 mm)
          Long-life relay output                                                                                250 VAC, 3 A                                                                E5EN (48 x 96 mm)
          250 VAC, 3 A (resistive load)                             Control output 1                            (resistive load)
          Relay output                                                                        Auxiliary outputs
          250 VAC, 3 A (resistive load)         + DO NOT              -                       (relay outputs)
         Voltage output (for driving SSR)                           DO NOT A
          12 VDC, 21 mA                                                                       Auxiliary output 2
          Current output
          0 to 20 mA DC                                                                       Auxiliary output 1
          4 to 20 mA DC
          Load: 600  max.                       mA USE -            US-E       B                                                         A heater burnout alarm, heater short alarm,
                                                                                                                                         heater overcurrent alarm, or input alarm is
                  Control output 2              -V                             B                   Input power supply                    sent to the output to which the alarm 1
         Voltage output (for driving SSR)                           +                                                                    function is assigned.
         12 VDC, 21 mA                          DO NOT           +                                    100 to 240 VAC
                                                USE                 TC/Pt                            24 VAC/VDC (no polarity)
Option Units                                                        universalinput
                                                Analog input                                                                                                                             E5CN-H (48 x 48 mm)

        E53-CNHH03N2                       E53-CNHBN2                     E53-CNQ03N2         E53-CNPBN2               E53-CNPHN2                             E53-CNP03N2
        Communications                     Event inputs                   Communications      Event Inputs and         External Power                         Communications (RS-485)
        (RS-485) and CT2                   and CT                         (RS-485) and        External Power Supply    Supply and CT                          and External Power Supply
                                                                          Control Output 2
            B(+)                                11                                                          11         External +                               B(+) 11
                    11                                                        B(+)
                                           EV1 12                                     11      EV1 12                   power supply   11 12 VDC,              RS-485
         RS-485                                                                                                                           20 mA
                                                                            RS-485                                               -                              A(-) 12
            A(-) 12                                                                                                                   12
                                                                              A(-) 12
                    13                     EV2  13                                                          13         DO NOT 13                              DO NOT 13
                                                                       DO NOT 13                                       USE
                                                                       USE                    EV2                                                             USE

        CT2       14                                     14                   + 14            External+ 14 12 VDC,                                            External+     14
                                           CT1                                                                                                                              15
             CT1                                                    Control output 2          power supply      20 mA                14                       power supply      12 VDC,
                                                         15                                                            CT1                                                      20 mA
                  15                                                          - 15                 - 15                                                                -                 E5AN-H (96 x 96 mm)
                                                                                                                                     15                                                     E5EN-H (48 x 96 mm)

         E53-CNH03N2                            E53-CN03N2                E53-CNBN2             E53-CNQHN2              E53-CNQHHN2                           E53-CNQBN2
         Communications                         Communications            Event inputs          Control Output 2        Control Output 2                      Event Inputs and
         (RS-485) and CT                        (RS-485)                                        and CT                  and CT2                               Control Output 2

             B(+)                                  B(+) 11                            11                + 11                     + 11                                       11
                     11
                                                RS-485                    EV1 12              Control output 2         Control output 2                            EV1 12
           RS-485
                                                   A(-) 12                EV2         13                - 12                     - 12                         EV2           13
             A(-) 12
      DO NOT 13                            DO NOT 13                                             DO NOT 13                               13
      USE                                  USE                                                   USE
                                           DO NOT 14                DO NOT 14                                                    CT2           14                  + 14
                     14                    USE                      USE                                         14
      CT1                                  DO NOT 15                                             CT1                                  CT1                     Control output 2
                                           USE                      DO NOT 15                                                                 15
                     15                                             USE                                         15                                                 - 15

E5CN-U                                                                                                                                                                                   Operation

                                                                                                                Auxiliary output

                                                                                                                250 VAC, 3 A (resistive load)
                                                                                                                (Relay outputs)

        Control output 1

      Relay output                                       DO NOT     Control output 1                            Auxiliary output 1
                                                         USE                                                                 Auxiliary output 2
      (three terminals used)               mA                          DO NOT A                                              (Control output (cooling side))
      SPDT, 250 VAC, 3 A
                                                          V             USE                                                                        An input error is sent to the         Safety Precautions
      (resistive load)                        DO NOT                                                                                               output to which the alarm 1
                                              USE                                   B                                                              function is assigned.
      Voltage output
                                               Analog input                          B                          Input power supply
      (for driving SSR)                                                      TC/Pt
                                                                             universal input                            100 to 240 VAC
       12 VDC, 21 mA                                                                                                    24 VAC/VDC (no polarity)
      Current output
       4 to 20 mA DC
       0 to 20 mA DC
       Load: 600 W max.

Note: For the Wiring Socket, purchase the P2CF-11 or PG3A-11 separately.

                                                                                                                                                                                         13
E5CN                    E5CN/E5CN-U                                                                                                           Temperature unit
   E5CN-U (48 x 48 mm)
                        Nomenclature

                        E5CN
                        E5CN-U

                        The front panel is the same for the E5CN and E5CN-U.

                                                  Operation indicators                                                                                                        No.1 display
                                                                                                                                                                              No. 2 display
                                                      Level Key
                                                                                                                                                                                 Up Key

E5AN (96 x 96 mm)                                                                                                                             Mode Key           Down Key
   E5EN (48 x 96 mm)
                        Dimensions                                                                                                                                                                                      (Unit: mm)

                        E5CN                                                                                                                                                                            Panel Cutout
                        Terminal Models
                                                                                 91                                                                              Mounted Separately                                    Group Mounted
                        E5CN-U                                                78
E5CN-H (48 x 48 mm)     Plug-in Models                6                                                                                                                                                               (48 number of units - 2.5)+10.0
                                                            1.5
                                         48 48

                                                                                                                                                                                                                        45+00.6

                                                  58                                                                                                44.8 44.8 48.8 60 min.                                          Group mounting does not
                                                                                                                                                                                                                      allow waterproofing.

                                                                                                                                                                                                        45+00.6   Recommended panel thickness is 1 to
                                                                                                                                                                                                                   5 mm.
                                                  Waterproof Mounting Adapter                                                                 Terminal Cover                                   45+00.6
                                                  Packing (Accessory)                                                                         (E53-COV17)                                                         Group mounting is not possible in the
                                                  (Accessory)                                                                                 (Accessory)                                                          vertical direction. (Maintain the specified
                                                                                                                                                                                                                   mounting space between Controllers.)
E5AN-H (96 x 96 mm)                                      Note: The terminal block cannot be removed.
   E5EN-H (48 x 96 mm)                                                                                                                                                                                           To mount the Controller so that it is
                                                                                                                                                                                                                   waterproof, insert the waterproof packing
                                                                                                                                                                                                                   onto the Controller.

                                                                                                                                                                                                                  When two or more Controllers are
                                                                                                                                                                                                                   mounted, make sure that the surrounding
                                                                                                                                                                                                                   temperature does not exceed the
                                                                                                                                                                                                                   allowable operating temperature
                                                                                                                                                                                                                   specified in the specifications.

                                                                                                                                                                                                        Panel Cutout

                                                      6                       (84.7)                                                          14.2               Mounted Separately                                    Group Mounted

                                         48 48                              70.5                                                                                                                                    (48 number of units - 2.5)+10.0

                                                                                                                                                                                                                        45+00.6

                                                                                                       58                                           44.8 44.8

                                                                                                                         Mounting Adapter                        60 min.                                45+00.6   Recommended panel thickness is 1 to 5
                                                                                                                         (Accessory)                                              45+00.6                          mm.
Operation
                        Accessories (Order Separately)                                                                                                                                                            Group mounting is not possible in the
                                                                                                                                                                                                                   vertical direction. (Maintain the specified
                        USB-Serial Conversion Cable                                                                                                                                                                mounting space between Controllers.)

                        E58-CIFQ1                                                                                                                                                                                 When two or more Controllers are
                                                                                                                                                                                                                   mounted, make sure that the surrounding
                                                                                                                                         250                                                                       temperature does not exceed the
                                                                                                                                                                                                                   allowable operating temperature specified
                                                                                                                                                                                                                   in the specifications.

Safety Precautions                                                                                                                                                                    (2,100)                    1,765
                                                                                                                                                                LED indicator (SD)

                                                      USB connector (type A plug)                                                                                             LED indicator (RD)                        Serial connector

14
                                                                                                                                                                                 E5CN/E5CN-U

Terminal Cover                                                                  Waterproof Packing                                                                                                                           E5CN
                                                                                                                                                                                                                                E5CN-U (48 x 48 mm)
E53-COV17                                                                       Y92S-29 (for DIN 48 48)

                        Note: The E53-COV10                                                                                         Order the Waterproof Packing separately if it becomes lost or                            E5AN (96 x 96 mm)
                                 cannot be used.                                                                                    damaged.                                                                                    E5EN (48 x 96 mm)
                                                                                                                                    The Waterproof Packing can be used to achieve an IP66 degree of
                       48                                                                                                           protection.
48.8                                                                                                                                (Deterioration, shrinking, or hardening of the waterproof packing may
                                                                                                                                    occur depending on the operating environment. Therefore, periodic
22                                                                                                                                 replacement is recommended to ensure the level of waterproofing
                                                                                                                                    specified in IP66. The time for periodic replacement depends on the
                                                                                                                                    operating environment. Be sure to confirm this point at your site.
                                                                                                                                    Consider one year a rough standard. OMRON shall not be liable for
                                                                                                                                    the level of water resistance if the customer does not perform periodic
                                                                                                                                    replacement.)
                                                                                                                                    The Waterproof Packing does not need to be attached if a waterproof
                                                                                                                                    structure is not required.

     9.1                                                                  21                               2.8                      E54-CT1                                                                                  E5CN-H (48 x 48 mm)
                                                                                                                      7.5
Current Transformers                                                      15    5.8 dia.                                            Thru-current (Io) vs. Output Voltage

E54-CT1                                                                                                                             (Eo) (Reference Values)

                                                               25 3                                                                 Maximum continuous heater current: 50 A (50/60 Hz)
                                                                                                                                    Number of windings: 4002
                                                                      10                                                            Winding resistance: 182

E54-CT3                                                                                            10.5                             Output voltage (Eo) V (r.m.s.)  100 V 50 Hz

                                                               40 40    40                                                                                              10                                 Distortion
                                                                                            Two, 3.5 dia.                                                                  1                                 factor 10%
                                                                                                                                                                                 1 k
                                                                                                                                                                    100 mV                                   3%
                                                                                                                                                                                                         1%                  E5AN-H (96 x 96 mm)
                                                                                                                                                                                                                                E5EN-H (48 x 96 mm)
                                                                           30                                                                                       10                         100

                                                                                                             2.36 dia.                                              1                       RL = 10
                                                                          30
                                                                                                                                                                    100 V
                                                                                           12 dia.
                                                                                                                                 9

                                                                                                                                                                    10

                                                                                                                                                                    1            10 100 mA 1         10  100 1,000 A

                                                                                                                                                                                               Thru-current (Io) A (r.m.s.)

                                                                  Two, M3 (depth: 4)                                                E54-CT3                                                                                  Operation
                          15
                                                                                                                                    Thru-current (Io) vs. Output Voltage
                                                  30
                                                                                                                                    (Eo) (Reference Values)

                                                                                                                                    Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                                                                    (Maximum continuous heater current for the
                                                                                                                                    Temperature Controller is 50 A.)
                                                                                                                                    Number of windings: 4002
                                                                                                                                    Winding resistance: 80.8

E54-CT3 Accessory         Connection Example                                                                                        Output voltage (Eo) V (r.m.s.)  100 V 50 Hz                             Distor-
                                                                                                                                                                       10                                   tion
Armature                                                                     Armature                                                                                 1        1 k                       factor           Safety Precautions
                                                                                                                                                                                                            10%
  Approx. 3 dia.                                                                                                                                                                 500
                                                                                                                                                                                                           3%
                                                                          Plug                                                                                                                           1%

                                                                                          Lead

                      18                                                                                                                                            100 mV                      100
                (22)                                                                                                                                                      10                   50
                                                                                                                                                                           1
                                                                                                                                                                                               RL = 10

Plug                                                                                                                                                              100 V

Approx. 6 dia.                                                                                                                                                           10
                                                                                                                                                                            1
                                                                                                                                                                                 10 100 mA  1        10  100 1,000 A

                                                                                                                                                                                               Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                         15
                        E5CN/E5CN-U

E5CN                    Adapter
   E5CN-U (48 x 48 mm)
                        Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@.

                                                                                                                                                                                                            Fixture (Accessory)

                                                                                                                                                                      4.7             76

                                                                                                                                                                                   69.6 to 77.6

                                                                                                                                 72 72

                                                                                                                                                                                                            67 67 87

E5AN (96 x 96 mm)       Mounted to E5CN                                                                                                                                            Panel (1 to 8 mm)
   E5EN (48 x 96 mm)                                                                                                                                                  48 48
                                                                                                                                 72 72

E5CN-H (48 x 48 mm)                                                                                                                                                   2.2     4.7

                                                                                                                                                                                 77.3 (to back of E5CN)

                        E5CN-U Wiring Socket

E5AN-H (96 x 96 mm)     Front-connecting Socket                                                                                                                       Terminal Layout/Internal Connections
   E5EN-H (48 x 96 mm)                                                                                                                                                                  (Top View)
                        P2CF-11          Eleven, M3.5 7.5                                                                      3             4.5
                                                                                                                                                                                         8765
                                         sems screws                                                                        7.8                                                                       4

                                                                                                                                                                                                                  Mounting Holes

                                                                                                                                                                                                                 Two, 4.5 dia. mounting holes

                                         70 max.                                                                                                                35.4

                                                                                                                            Two,                                              9                       3                                     400.2
                                                                                                                            4.5-dia.
                                                                                                                            holes                                             10 11 1 2                     Note: Can also be mounted to a DIN track.

                                                 4    50 max.

                                                                                                                                    31.2 max.

                        Note: A model with finger protection (P2CF-11-E) is also available.

Operation               Back-connecting Socket                                                                                                                4 73         Terminal Layout/Internal Connections
                        P3GA-11                                                                                                                                                            (Bottom View)
                                                                                                                                                      25.6
                                                                                                                   27 dia.                                                          5 678
                                                                                                                                 4.5 16.3 6.2                                      4
                                                                                                    45                                                    8.7
                                                                                                                                                                                   3                     9
                                                                                                                      45
                                                                                                                                                                                   2 1 11 10

Safety Precautions                                                                                                                                                         6

                        Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets.
                                2. A Protective Cover for finger protection (Y92A-48G) is also available.

16
Basic-type Digital Temperature Controller                                                                                                                 E5CN
                                                                                                                                                             E5CN-U (48 x 48 mm)
E5AN/E5EN (96 x 96 mm and 48 x 96 mm)

New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with                                                                                          E5AN (96 x 96 mm)
Enhanced Functions and Performance.                                                                                                                          E5EN (48 x 96 mm)
Improved Indication Accuracy and
Preventive Maintenance Function.

Indication Accuracy

Thermocouple input: 0.3% of PV (previous models: 0.5%)

Pt input: 0.2% of PV (previous models: 0.5%)

Analog input: 0.2% FS (previous models: 0.5%)

A PV/SV-status display function can be set to automatically

alternate between displaying the status of the Temperature

Controller (auto/manual, RUN/STOP, and alarms) and the PV or                                                                                              E5CN-H (48 x 48 mm)

  SV.                                                                                      96 96 mm       48 96 mm
Preventive maintenance for relays in the Temperature Controller                              E5AN             E5EN

  using a Control Output ON/OFF Counter.

Three-level display that simultaneously displays the PV, SV, and

MV.

One-touch operation with PF Key that can be assigned to auto/manual, RUN/                            Refer to Safety Precautions on page 66.
  STOP, or other functions.

Main I/O Functions                                     E5AN                 E5EN           3-level Display                                                E5AN-H (96 x 96 mm)
                                                                                           Simultaneously displays set items,                                E5EN-H (48 x 96 mm)
                                    Event Inputs
                                     None                                                 such as the PV, SV, and MV.
                                     Two
                                                                                            A 2-level display when shipped from the factory. A
        Sensor Inputs                                                                         3-level display is activated if parameters are
         Universal thermocouple/Pt inputs                                                    initialized. For details on the third display level, refer
                                                                                              to the User's Manual, Basic Type (Cat. No. H156).
         (Models with temperature inputs)
         Analog current/voltage inputs                                                    4-digit Display

         (Models with analog inputs)                                        Auxiliary Outputs                Auto/manual switching                       Operation
                                                                            Three                         Temperature Controller
        Indication Accuracy
         Thermocouple input: 0.3% of PV              Control Output 2                                       status display
         Pt input: 0.2% of PV                         Voltage output                                     Simple program function
         Analog input: 0.2% FS                                                                            Control output ON/OFF
                                                         (for driving SSR)
        Sampling Period                                 Long-life relay                                      count alarm
         250 ms                                                                                             PV change rate alarm
                                                         output (hybrid)                                     Models also available with
                          PF Key
                          (Programmable function key)                                                         RS-485 or RS-232C
                                                                                                              communications

                                                       Control Output 1                                                                                   Safety Precautions
                                                       Relay output
                                                       Voltage output (for driving SSR)
                                                       Current output

This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.

E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)

E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)

                                                                                                                                                          17
                        E5AN/E5EN

                        Lineup

E5CN                                                                                                                          1 control output  3 auxiliary outputs
   E5CN-U (48 x 48 mm)
                                                    Temperature input                                                         2 control outputs 3 auxiliary outputs
                                                       Analog input
                        E5AN/E5EN   Terminal block
                        Basic Type
                                                                                                                              1 control output
                                                                                                                                                3 auxiliary outputs

                                                                                                                              2 control outputs 3 auxiliary outputs

E5AN (96 x 96 mm)       Note: Models with one control output or two control outputs can be used for heating/cooling control.
   E5EN (48 x 96 mm)
                        Model Number Structure                                                Option Units
E5CN-H (48 x 48 mm)
                        Model Number Legend                                                   E53-@

                        Controllers                                                                      1

                        E5AN/E5EN-@3@M@@-@-500-N                                              1. Function
                                                                                                  EN01: RS-232C communications
                                                    123 4 5 6 7 8 9                               EN03: RS-485 communications
                                                                                                  AKB: Event input
                        1. Control Output 1
E5AN-H (96 x 96 mm)         R: Relay output
   E5EN-H (48 x 96 mm)      Q: Voltage output (for driving SSR)
                            C: Current output
Operation
                        2. Auxiliary Outputs
Safety Precautions          3: Three outputs

                        3. Heater Burnout/SSR Failure, Control Output 2, or External
                            Power Supply for ES1B
                            Blank: None
                            Q: Control output 2 (voltage output for driving SSR)
                            Y: Long-life relay output (hybrid)
                            H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
                            HH: Heater burnout/SSR failure/Heater overcurrent detection
                                  (CT2)
                            P: Power supply for sensor

                        4. Option
                            M: Option Unit can be mounted.

                        5. Input Type
                            T: Universal thermocouple/platinum resistance thermometer input
                            L: Analog current/voltage input

                        6. Power Supply Voltage
                            Blank: 100 to 240 VAC
                            D: 24 VAC/VDC

                        7. Case Color
                            Blank: Black
                            W: Silver

                        8. Terminal Cover
                            -500: With terminal cover

                        9. Version
                            N: Available only to models released after January 2008.

18
                                                                                                             E5AN/E5EN

Ordering Information

E5AN                                                                                                                             E5CN
Controllers with Terminal Blocks                                                                                                    E5CN-U (48 x 48 mm)

Size          Case    Power       Input type      Auxilia-  Control output                     Functions     Model
              color   supply                          ry             1
                      voltage                                                   Heater Power supply Control
                                                  outputs                      burnout for Sensor output 2

                                                            Relay output                                     E5AN-R3MT-500-N

                                                            Voltage output                                   E5AN-Q3MT-500-N
                                                            (for driving SSR)

                                                            Current output                                   E5AN-C3MT-500-N

                                                            Relay output       1                             E5AN-R3HMT-500-N    E5AN (96 x 96 mm)
                                                                                                                                    E5EN (48 x 96 mm)
                                                            Voltage output     1                             E5AN-Q3HMT-500-N
                                                            for driving SSR)

                                                            Relay output       2                             E5AN-R3HHMT-500-N

                                                            Voltage output     2                             E5AN-Q3HHMT-500-N
                                                            for driving SSR)

                               Thermocouple                                                     Voltage
                                                                                                output
                               or                 3         Relay output                                     E5AN-R3QMT-500-N
                               Resistance                                                       Voltage      E5AN-Q3QMT-500-N
                                                                                                output
                               thermometer                  Voltage output
                                                            (for driving SSR)
                                                                                                                                 E5CN-H (48 x 48 mm)
                                                            Current output                      Voltage      E5AN-C3QMT-500-N
                                                                                                output
                                                            Relay output
                      100 to                                Voltage output                                    E5AN-R3YMT-500-N
                      240 VAC                               (for driving SSR)                   Long-life
                                                            Current output                      relay E5AN-Q3YMT-500-N
                                                                                                output

                                                                                                              E5AN-C3YMT-500-N

              Black                                         Relay output          Sensor Power               E5AN-R3PMT-500-N
                                                                                  Sensor Power               E5AN-Q3PMT-500-N
                                                            Voltage output
                                                            (for driving SSR)

                                                            Relay output                                     E5AN-R3ML-500-N

                                                            Voltage output                                   E5AN-Q3ML-500-N     E5AN-H (96 x 96 mm)
                                                            (for driving SSR)                                                       E5EN-H (48 x 96 mm)

1/4 DIN                                                     Current output                                   E5AN-C3ML-500-N
96 96 78                                                                                                 E5AN-R3HML-500-N
(W H D)                    Analog             3         Relay output       1
                               (current/voltage)                                                             E5AN-Q3HML-500-N
                                                            Voltage output
                                                            (for driving SSR)  1

                                                            Voltage output                      Long-life
                                                            (for driving SSR)                   relay E5AN-Q3YML-500-N
                                                                                                output

                                                            Relay output                                     E5AN-R3MTD-500-N

                                                            Voltage output                                   E5AN-Q3MTD-500-N
                                                            (for driving SSR)
                                                                                                                                 Operation
                               Thermocouple                 Current output                                   E5AN-C3MTD-500-N
                                                                                                             E5AN-R3HMTD-500-N
                      24 VAC/ or                  3         Relay output       1
                                                                                                             E5AN-Q3HMTD-500-N
                      VDC      Resistance                   Voltage output
                                                            (for driving SSR)
                               thermometer                                     1

                                                            Relay output       2                             E5AN-R3HHMTD-500-N

                                                            Voltage output     2                             E5AN-Q3HHMTD-500-N
                                                            (for driving SSR)

                                                            Relay output                                     E5AN-R3MT-W-500-N   Safety Precautions

                                                            Voltage output                                   E5AN-Q3MT-W-500-N
                                                            (for driving SSR)                                E5AN-C3MT-W-500-N
                                                                                                             E5AN-R3HMT-W-500-N
                      100 to                                Current output                                   E5AN-Q3HMT-W-500-N
                      240 VAC

                               Thermocouple or              Relay output       1

              Silver           Resistance         3         Voltage output     1
                                                            (for driving SSR)
                               thermometer

                                                            Relay output                                     E5AN-R3MTD-W-500-N

                      24 VAC/                               Voltage output                                   E5AN-Q3MTD-W-500-N
                      VDC                                   (for driving SSR)

                                                            Current output                                   E5AN-C3MTD-W-500-N

                                                                                                                                 19
                        E5AN/E5EN

E5CN                    E5EN
   E5CN-U (48 x 48 mm)  Controllers with Terminal Blocks

                        Size          Case    Power       Input type  Auxilia-  Control                              Functions  Control       Model
                                      color   supply                      ry    output 1                                        output 2
                                              voltage                                               Heater Power supply
                                                                      outputs                      burnout for Sensor

                                                                                Relay output                                                  E5EN-R3MT-500-N

                                                                                Voltage output                                                E5EN-Q3MT-500-N
                                                                                (for driving SSR)

                                                                                Current output                                                E5EN-C3MT-500-N

E5AN (96 x 96 mm)                                                               Relay output       1                                          E5EN-R3HMT-500-N
   E5EN (48 x 96 mm)
                                                                                Voltage output     1                                          E5EN-Q3HMT-500-N
                                                                                (for driving SSR)

                                                                                Relay output       2                                          E5EN-R3HHMT-500-N

                                                                                Voltage output     2                                          E5EN-Q3HHMT-500-N
                                                                                (for driving SSR)

                                                       Thermocouple             Relay output                                    Voltage       E5EN-R3QMT-500-N
                                                                                                                                output        E5EN-Q3QMT-500-N
                                                       or             3         Voltage output
                                                       Resistance               (for driving SSR)                               Voltage
                                                                                                                                output
E5CN-H (48 x 48 mm)                                    thermometer

                                                                                Current output                                  Voltage       E5EN-C3QMT-500-N
                                                                                Relay output                                    output

                                              100 to                                                                            Long-life     E5EN-R3YMT-500-N
                                              240 VAC                                                                           relay output

                                                                                Voltage output                                  Long-life     E5EN-Q3YMT-500-N
                                                                                (for driving SSR)                               relay output

                                                                                Current output                                  Long-life     E5EN-C3YMT-500-N
                                                                                Relay output                                    relay output
                                      Black
                                                                                                            Sensor Power                      E5EN-R3PMT-500-N

                                                                                Voltage output              Sensor Power                      E5EN-Q3PMT-500-N
                                                                                (for driving SSR)
E5AN-H (96 x 96 mm)
   E5EN-H (48 x 96 mm)                                                          Relay output                                                  E5EN-R3ML-500-N

                        1/8 DIN                                                 Voltage output                                                E5EN-Q3ML-500-N
                        48 96 78                                            (for driving SSR)
                        (W H D)
                                                       Analog                   Current output                                                E5EN-C3ML-500-N
                                                       (current/volt- 3
                                                       age)                     Relay output       1                                          E5EN-R3HML-500-N

                                                                                                         1                                    E5EN-Q3HML-500-N
                                                                                Voltage output
                                                                                (for driving SSR)                               Long-life     E5EN-Q3YML-500-N
                                                                                                                                relay output

                                                                                Relay output                                                  E5EN-R3MTD-500-N

                                                                                Voltage output                                                E5EN-Q3MTD-500-N
                                                                                (for driving SSR)
Operation
                                                       Thermocouple             Current output                                                E5EN-C3MTD-500-N
                                                                                                                                              E5EN-R3HMTD-500-N
                                              24 VAC/ or              3         Relay output       1
                                                                                                                                              E5EN-Q3HMTD-500-N
                                              VDC      Resistance               Voltage output
                                                                                (for driving SSR)
                                                       thermometer                                 1

                                                                                Relay output       2                                          E5EN-R3HHMTD-500-N

                                                                                Voltage output     2                                          E5EN-Q3HHMTD-500-N
                                                                                (for driving SSR)

Safety Precautions                                                              Relay output                                                  E5EN-R3MT-W-500-N

                                              100 to                            Voltage output                                                E5EN-Q3MT-W-500-N
                                              240 VAC                           (for driving SSR)                                             E5EN-C3MT-W-500-N
                                                                                                                                              E5EN-R3HMT-W-500-N
                                                                                Current output                                                E5EN-Q3HMT-W-500-N
                                                                                                                                              E5EN-R3MTD-W-500-N
                                                       Thrmocouple              Relay output       1                                          E5EN-Q3MTD-W-500-N

                                      Silver           or             3         Voltage output     1
                                                       Resistance               (for driving SSR)

                                                       thermometer

                                              24 VAC/                           Relay output
                                              VDC
                                                                                Voltage output
                                                                                (for driving SSR)

                                                                                Current output                                                E5EN-C3MTD-W-500-N

20
                                                                                                           E5AN/E5EN

Option Units                                                         Function                   Model                 E5CN
                                             RS-232C communications                           E53-EN01                   E5CN-U (48 x 48 mm)
                            Name             RS-485 communications                            E53-EN03
Communications Unit                         Event inputs                                     E53-AKB
Event Input Unit

Accessories (Order Separately)                                 Current Transformers (CTs)

USB-Serial Conversion Cable

                                     Model                                     Hole diameter                Model     E5AN (96 x 96 mm)
                                  E58-CIFQ1                                         5.8 dia.               E54-CT1       E5EN (48 x 96 mm)
                                                                                   12.0 dia.               E54-CT3
Terminal Cover

Connectable models                           Model             CX-Thermo Support Software

E5AN                                         E53-COV16                                             Model
E5EN                                                                                          EST2-2C-MV4

Note: The Terminal Cover comes with the E5CN-@@@-500 models.

Waterproof Packing

Connectable models                            Model                                                                   E5CN-H (48 x 48 mm)
          E5AN                               Y92S-P4
          E5EN                               Y92S-P5

Note: The Waterproof Packing is included with the Controller.

                                                                                                                      E5AN-H (96 x 96 mm)
                                                                                                                         E5EN-H (48 x 96 mm)

                                                                                                                      Operation

                                                                                                                      Safety Precautions

                                                                                                                    21
                        E5AN/E5EN

                        Specifications

E5CN                    Ratings
   E5CN-U (48 x 48 mm)
                        Power supply voltage                 No D in model number: 100 to 240 VAC, 50/60 Hz
                                                             D in model number: 24 VAC, 50/60 Hz; 24 VDC

                        Operating voltage range              85% to 110% of rated supply voltage

                        Power                                100 to 240 VAC: 10 VA
                        consumption                          24 VAC/VDC: 5.5 VA (24 VAC)/4 W (24 VDC)

E5AN (96 x 96 mm)       Sensor input                         Models with temperature inputs
   E5EN (48 x 96 mm)                                           Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
                        Input impedance                        Platinum resistance thermometer: Pt100 or JPt100
                        Control method                         Infrared temperature sensor: 10 to 70C, 60 to 120C, 115 to 165C, or 140 to 260C
                                                               Voltage input: 0 to 50 mV

                                                             Models with analog inputs
                                                               Current input: 4 to 20 mA or 0 to 20 mA
                                                               Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

                                                             Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB.)

                                                             ON/OFF control or 2-PID control (with auto-tuning)

                        Control   Relay output               SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V,
                        output                               10 mA
                                  Voltage output
                                  (for driving SSR)          Output voltage: 12 VDC 15% (PNP), max. load current: 40 mA,
                                  Current output             With short-circuit protection circuit: Max. load current of 21 mA for control output 2

                                                             4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 10,000

E5CN-H (48 x 48 mm)                    Long-life relay out-  SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 1,000,000 operations, load power supply voltage: 75
                                       put                   to 250 VAC (DC loads cannot be connected.), minimum applicable load: 5 V, 10 mA, leakage current: 5 mA
                                                             max. (250 VAC, 60 Hz)
                                       Number of outputs
                        Auxiliary                            3
                        output Output specifica-
                                                             Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable
                                       tions                 load: 5 V, 10 mA

                                  Number of inputs 2

                        Event     External contact in-       Contact input: ON: 1 k max., OFF: 100 k min.
                        input     put specifications         Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
                                                             Current flow: Approx. 7 mA per contact

                        External power supply for ES1B 12 VDC 10%, 20 mA, short-circuit protection circuit provided

                        Setting method                       Digital setting using front panel keys

E5AN-H (96 x 96 mm)     Indication method                    11-segment digital display and individual indicators (7-segments displays also possible)
   E5EN-H (48 x 96 mm)                                       Character height: E5AN: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN: PV: 11.8 mm, SV: 8.1 mm,

                                                                                     MV: 5.8 mm
                                                             Content of 3-level display: PV/SV/MV, PV/SV/multi-SP, or soak time remain
                                                             Number of digits: 4 for PV, SV, and MV

                        Multi SP                             Up to four set points (SP0 to SP3) can be saved and selected using event inputs, key operations, or serial
                                                             communications.

                        Bank switching                       Not supported.

                        Other functions                      Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
                                                             detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
                                                             protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, logic
                                                             operations, PV/SV status display, simple program, automatic cooling coefficient adjustment

                        Ambient operating temperature -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C

                        Ambient operating humidity 25% to 85%

Operation               Storage temperature                  -25 to 65C (with no condensation or icing)

                         A 2-level display when shipped from the factory. A 3-level display is activated if parameters are initialized. For details on the third display level,
                          refer to the User's Manual, Basic Type (Cat. No. H156).

Safety Precautions

22
                                                                                                                                                                                         E5AN/E5EN

Input Ranges                                                                                                                                                                                                         E5CN
                                                                                                                                                                                                                        E5CN-U (48 x 48 mm)
Thermocouple/Platinum Resistance Thermometer (Universal inputs)

Input                           Platinum resistance                                                    Thermocouple                                                               Infrared temperature    Analog
type                                 thermometer                                                                                                                                           sensor           input
                                                                                                                                                                                                             0 to
Name                                   Pt100         JPt100               K           J        T       EL                 U       N      R  S  B    W                       PL    10 to  60 to  115  140   50 mV
                                                                                                                                                                             II   70C           to   to
                                                                                                                                                                                          120   165  260  Usable
                                                                                                                                                                                          C    C   C   in the
                                                                                                                                                                                                          following
                        2300                                                                                                                                          2300                                ranges
                        1800                                                                                                                                1800                                          by
                        1700                                                                                                             1700 1700                                                        scaling:
                                                                                                                                                                                                          -1999 to
                        1600                                                                                                                                                                              9999 or
                                                                                                                                                                                                          -199.9
                        1500                                                                                                                                                                              to 999.9

                        1400                                        1300                                                          1300                                      1300                              23     E5AN (96 x 96 mm)
                        1300                                                                                                                                                                                            E5EN (48 x 96 mm)
Temperature range (C)
                        1200

                        1100

                        1000                                                     850                             850
                                  850

                         900

                        800

                        700                                                                            600

                        600            500.0         500.0                500.0

                        500                                                           400.0 400 400.0                  400 400.0

                        400                                                                                                                                                                          260

                        300                                                                                                                                                              120 165

                        200                   100.0          100.0                                                                                                                90

                        100                                                                                                                    100                                                                   E5CN-H (48 x 48 mm)

                        0                     0.0            0.0                                                                         0  0       0                       0     0      0      0    0

                        -100.0                                            -20.0 -100 -20.0                       -100

                        -200.0  -200 -199.9          -199.9         -200                       -200 -199.9 -200        -200 -199.9 -200

Setting                         0      1      2      3       4      5        6   7          8  9 10 11 12 13 14 15 16 17 18 24 25 19 20 21 22
number

Shaded settings are the default settings.                                                                              JPt100: JIS C 1604-1989, JIS C 1606-1989
The applicable standards for the input types are as follows:                                                           Pt100: JIS C 1604-1997, IEC 751
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1                                                                     PL II: According to Platinel II electromotive force charts from BASF (previously
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985                                                                                                     Engelhard)
W: W5Re/W26Re, ASTM E988-1990

Models with Analog Inputs                                                                                                                                                                                            E5AN-H (96 x 96 mm)
                                                                                                                                                                                                                        E5EN-H (48 x 96 mm)
                        Input type                           Current                                   Voltage

Input specification 4 to 20mA 0 to 20 mA 1 to 5 V 0 to 5 V 0 to 10 V

Setting range                                    Usable in the following ranges by scaling:
                                                 -1999 to 9999, -199.9 to 999.9, -19.99 to 99.99 or -1.999 to 9.999

Setting number 0                                                    1                    2        3                    4

Shaded settings are the default settings.

                                                                                                                                                                                                                     Operation

                                                                                                                                                                                                                     Safety Precautions

                                                                                                                                                                                                                     23
                        E5AN/E5EN

E5CN                    Alarm Outputs
   E5CN-U (48 x 48 mm)
                        Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
                        Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

                        Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
                                following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
                                failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).

                         Set                          Alarm output operation                        1. With set values 1, 4 and 5, the upper and lower limit values can
                        value                                                                            be set independently for each alarm type, and are expressed as
                               Alarm type             When X is                  When X is               "L" and "H."
                                                       positive                   negative
                                                                                                    2. Set value: 1, Upper- and lower-limit alarm

E5AN (96 x 96 mm)       0      Alarm function    Output OFF                                         Case 1           Case 2           Case 3 (Always ON)   H < 0, L < 0
   E5EN (48 x 96 mm)           OFF                                                                                                         H SP L
                                                                                                           L H SP      SP L H                              H < 0, L > 0
                        1 Upper- and             ON   LH                                               H < 0, L > 0     H > 0, L < 0     H L SP            H  L
                        1 lower-limit            OFF                                                   H < L            H > L                    SP H L    H > 0, L < 0
                                                                            2                                                                              H  L

                                                      SP

                                                 ON       X                 ON   X
                                                 OFF  SP
                        2 Upper limit                                       OFF
                                                                                                SP

                                                 ON   X                     ON       X              3. Set value: 4, Upper- and lower-limit range
                                                                            OFF  SP
                        3 Lower limit            OFF
                                                                     SP
                                                                                                    Case 1           Case 2           Case 3 (Always OFF)
                        4 Upper- and             ON   LH                                                                                     H SP L        H < 0, L < 0
                                                                                                           L H SP      SP L H
                        1 lower-limit range OFF                             3                         H < 0, L > 0      H > 0, L < 0      H L SP           H < 0, L > 0
                                                                                                       H < L            H > L                              H  L
                                                      SP

E5CN-H (48 x 48 mm)            Upper- and             LH

                        5 lower-limit with ON                               4                                                                              H > 0, L < 0
                                                 OFF                                                                                                       H  L
                        1 standby                                    SP                                                                            SP H L

                               sequence          5

                               Upper-limit with  ON                      X  ON   X                  4. Set value: 5, Upper- and lower-limit with standby sequence
                                                 OFF                                                     For Upper- and Lower-Limit Alarm Described Above
                        6 standby
                                                                            OFF
                               sequence               SP                                        SP   Case 1 and 2
                                                                                                     Always OFF when the upper-limit and lower-limit hysteresis
                               Lower-limit with  ON   X                     ON       X               overlaps.
                                                 OFF                        OFF  SP
                        7 standby                                                                   Case 3: Always OFF

                               sequence               SP

                        8      Absolute-value    ON        X                ON      X               5. Set value: 5, Upper- and lower-limit with standby sequence
                               upper-limit       OFF  0                     OFF          0               Always OFF when the upper-limit and lower-limit hysteresis
                                                                                                         overlaps.

E5AN-H (96 x 96 mm)     9      Absolute-value    ON        X                ON      X
   E5EN-H (48 x 96 mm)         lower-limit       OFF  0                     OFF           0

                               Absolute-value                               ON      X
                                                                            OFF          0
                        10     upper-limit with  ON        X
                               standby           OFF  0

                               sequence

                               Absolute-value

                        11     lower-limit with  ON        X                ON      X
                               standby           OFF  0                     OFF          0

                               sequence

                        12     LBA (for alarm 1  ---
                               only)

                        13     PV change rate    ---
                               alarm

Operation

Safety Precautions

24
                                                                                                             E5AN/E5EN

Characteristics                                                                                                                                     E5CN
                                                                                                                                                       E5CN-U (48 x 48 mm)
Indication accuracy         Thermocouple: (0.3% of indicated value or 1C, whichever is greater) 1 digit max. 1
                            Platinum resistance thermometer: (0.2% of indicated value or 0.8C, whichever is greater) 1 digit max.
                            Analog input: 0.2% FS 1 digit max.
                            CT input: 5% FS 1 digit max.

Transfer output accuracy 0.3% FS max.

Influence of temperature    Thermocouple input (R, S, B, W, PL II): (1% of PV or 10C, whichever is greater) 1 digit max.
2                           Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. 3
                            Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max.
Influence of voltage 2      Analog input: (1%FS) 1 digit max.

Input sampling period 250 ms

Hysteresis                  Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1      E5AN (96 x 96 mm)
                            EU) 4                                                                                                                      E5EN (48 x 96 mm)
                            Models with analog input: 0.01 to 99.99% FS (in units of 0.01% FS)

Proportional band (P)       Models with thermocouple/platinum resistance thermometer input (universal input): 0.1 to 999.9 EU (in units of 0.1
                            EU) 4
                            Models with analog input: 0.1 to 999.9% FS (in units of 0.1% FS)

Integral time (I)           0 to 3999 s (in units of 1 s)

Derivative time (D)         0 to 3999 s (in units of 1 s) 5

Control period              0.5, 1 to 99 s (in units of 1 s)

Manual reset value          0.0 to 100.0% (in units of 0.1%)

Alarm setting range         -1999 to 9999 (decimal point position depends on input type)

Affect of signal source Thermocouple: 0.1C/ max. (100  max.)                                                                                       E5CN-H (48 x 48 mm)
                            Platinum resistance thermometer: 0.1C/ max. (10  max.)
resistance

Insulation resistance       20 M min. (at 500 VDC)

Dielectric strength         2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

Vibration Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions

Shock       Malfunction 100 m/s2, 3 times each in X, Y, and Z directions

resistance Destruction 300 m/s2, 3 times each in X, Y, and Z directions

Weight      E5AN            Controller: Approx. 310 g, Mounting Bracket: Approx. 100 g
            E5EN            Controller: Approx. 260 g, Mounting Bracket: Approx. 100 g

Degree of protection        Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection           Non-volatile memory (number of writes: 1,000,000 times)                                                                 E5AN-H (96 x 96 mm)
                                                                                                                                                       E5EN-H (48 x 96 mm)
Setup Tool                  CX-Thermo version 4.0 or higher

Setup Tool port             Provided on the bottom of the E5AN and E5EN.
                            An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN and E5EN 6

                 Approved   UL 61010-1, CSA C22.2 No. 1010-1
                 standards  EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II
Standards
                 Conformed
                 standards

                            EMI:                                                 EN 61326

                            Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                            Noise Terminal Voltage:                              EN 55011 Group 1, class A

                            EMS:                                                 EN 61326

                            ESD Immunity:                                        EN 61000-4-2

EMC                         Electromagnetic Field Immunity:                      EN 61000-4-3                                                       Operation

                            Burst Noise Immunity:                                EN 61000-4-4

                            Conducted Disturbance Immunity:                      EN 61000-4-6

                            Surge Immunity:                                      EN 61000-4-5

                            Power Frequency Magnetic Field Immunity:             EN 61000-4-8

                            Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U             Safety Precautions
     and L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max.
     is not specified. The indication accuracy of B thermocouples in the 400 to 800C range is 3C max. The indication accuracy of the R and S
     thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is 0.3 of PV or 3C,
     whichever is greater, 1 digit max. The indication accuracy of PL II thermocouples is 0.3 of PV or 2C, whichever is greater, 1 digit max.

2. Ambient temperature: -10C to 23C to 55, Voltage range: -15% to 10% of rated voltage
3. K thermocouple at -100C max.: 10C max.
4. "EU" stands for Engineering Unit and is used as the unit after scaling. For a temperature sensor, the EU is C or F.
5. When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s).
6. External communications (RS-232C or RS-485) and cable communications for the Setup Tool can be used at the same time.

                                                                                                                                                25
                        E5AN/E5EN

E5CN                    USB-Serial Conversion Cable                                                Current Transformer (Order Separately)
   E5CN-U (48 x 48 mm)                                                                             Ratings
                        Applicable OS             Windows 2000, XP, or Vista

                        Applicable software       Thermo Mini, CX-Thermo version                   Dielectric strength 1,000 VAC for 1 min
                                                  4.0 or higher
                                                                                                   Vibration resistance 50 Hz, 98 m/s2

                        Applicable models         E5AN/E5EN/E5CN/E5CN-U/E5AN-                      Weight                                 E54-CT1: Approx. 11.5 g,
                                                  H/E5EN-H/E5CN-H                                                                         E54-CT3: Approx. 50 g

                        USB interface standard    Conforms to USB Specification 1.1.               Accessories                            Armatures (2)
                                                                                                   (E54-CT3 only)                         Plugs (2)
                        DTE speed                 38400 bps

E5AN (96 x 96 mm)       Connector specifications  Computer: USB (type A plug)                      Heater Burnout Alarms, SSR Failure
   E5EN (48 x 96 mm)                              Temperature Controller: Setup Tool               Alarms, and Heater Overcurrent Alarms
                                                  port (on bottom of Controller)

                        Power supply              Bus power (Supplied from USB host                                                          Models with detection for single-
                                                  controller.)                                                                               phase heaters: One input
                                                                                                                                             Models with detection for single-
                        Power supply voltage      5 VDC                                            CT input (for heater cur-                 phase or three-phase heaters: Two
                                                                                                   rent detection)                           inputs
                        Current consumption       70 mA
                                                                                                   Maximum heater current                    50 A AC
                        Ambient operating temper- 0 to 55C (with no condensation or               Input current indication
                                                                                                   accuracy                                  5% FS 1 digit max.
                        ature                     icing)                                           Heater burnout alarm set-
                                                                                                   ting range 1                              0.1 to 49.9 A (in units of 0.1 A)
                        Ambient operating humidity 10% to 80%                                      SSR failure alarm setting                 Minimum detection ON time: 100 ms
                                                                                                   range 2
                        Storage temperature       -20 to 60C (with no condensation                Heater overcurrent alarm                  0.1 to 49.9 A (in units of 0.1 A)
                                                  or icing)                                        setting range 3                           Minimum detection OFF time: 100 ms
E5CN-H (48 x 48 mm)
                        Storage humidity          10% to 80%                                                                                 0.1 to 49.9 A (in units of 0.1 A)
                                                                                                                                             Minimum detection ON time: 100 ms
                        Altitude                  2,000 m max.

                        Weight                    Approx. 100 g

                        Note: A driver must be installed in the personal computer. Refer to        1. For heater burnout alarms, the heater current will be measured
                                installation information in the operation manual for the                when the control output is ON, and the output assigned to the
                                Conversion Cable.                                                       alarm 1 function will turn ON if the heater current is lower than the
                                                                                                        set value (i.e., heater burnout detection current value).
                        Communications Specifications
                                                                                                   2. For SSR failure alarms, the heater current will be measured when
E5AN-H (96 x 96 mm)     Transmission line         RS-485: Multipoint                                    the control output is OFF, and the output assigned to the alarm 1
   E5EN-H (48 x 96 mm)  connection method         RS-232C: Point-to-point                               function will turn ON if the heater current is higher than the set
                                                                                                        value (i.e., SSR failure detection current value).
                        Communications            RS-485 (two-wire, half duplex) or RS-
                                                  232C                                             3. For heater overcurrent alarms, the heater current will be
                                                                                                        measured when the control output is ON, and the output assigned
                        Synchronization method Start-stop synchronization                               to the alarm 1 function will turn ON if the heater current is higher
                                                                                                        than the set value (i.e., heater overcurrent detection current
                        Protocol                  CompoWay/F, SYSWAY, or Modbus                         value).

                        Baud rate                 1200, 2400, 4800, 9600, 19200, 38400,
                                                  or 57600 bps

                        Transmission code         ASCII                                            Electrical Life Expectancy Curve for
                                                                                                   Relays (Reference Values)
                        Data bit length           7 or 8 bits

                        Stop bit length           1 or 2 bits

                                                  Vertical parity (none, even, odd)                Life ( 104 operations)  500
                                                  Frame check sequence (FCS) with                                           300
                                                  SYSWAY
Operation               Error detection           Block check character (BCC) with
                                                  CompoWay/F or CRC-16 Modbus
                                                                                                                            100           E5AN/E5EN

                                                                                                                                          250 VAC, 30 VDC

                                                                                                                                          (resistive load)

                                                                                                                            50            cos = 1

                        Flow control              None                                                                      30

                        Interface                 RS-485, RS-232C

                        Retry function            None                                                                      10
                                                                                                                             5
                        Communications buffer 217 bytes                                                                      3

Safety Precautions      Communications            0 to 99 ms
                        response wait time        Default: 20 ms

                         The baud rate, data bit length, stop bit length, and vertical parity can                           1
                          be individually set using the Communications Setting Level.
                                                                                                                                 0  1  2  3  4              5  6

                                                                                                                                             Switching current (A)

                                                                                                   Note: Do not connect a DC load to a Controller with a Long-life Relay
                                                                                                           Output.

26
                                                                                                                         E5AN/E5EN

External Connections

A voltage output (control output 1, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,     E5CN
  do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the            E5CN-U (48 x 48 mm)
  measured temperature values as a result of leakage current.
  The voltage output (control output 2, for driving SSR) has basic insulation provided for the internal circuit.

Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose.

Controllers                                                                                          Option Units

100 to 240 VAC                                                                                                         Communications
24 VAC/VDC (no polarity)

  Control output 1                                                                                   E53-EN01            E53-EN03        E53-AKB          E5AN (96 x 96 mm)
                                                                                                     RS-232C             RS-485          Event inputs        E5EN (48 x 96 mm)
Relay output                                                                                        11 SD               11 B (+)
250 VAC, 5A                                                                                         12 RD               12 A (-)        11
  (resistive load)                                                                                   13 SG
Voltage output                                            1            Event Inputs                                      13 DO NOT USE   12  EV2
(for driving SSR)       Input power supply                    11                                                                                      EV
  12 VDC, 40 mA
Current output                                            2   12  EV2                                                                    13
  0 to 20 mA DC                                                            EV1                                                                   CT1/CT2
  4 to 20 mA DC                                           3
  Load: 600  max.           Control output 1                  13                                External Power Supply
                                                                      CT1/CT2 Control Output 2
  Control output 2                                        4                                      +
                                                              14              +
Voltage output                                            5                                       External power supply
(for driving SSR)         Auxiliary output 3                      CT1 Control output 2           - 12 VDC, 20 mA
                                                                                                 DO NOT
      12 VDC, 21 mA                                       6   15              -                  USE

Long-life relay output                                    7   16  CT2 DO NOT
250 VAC, 3 A              Auxiliary output 2
(resistive load)                                                              USE
                                                          8
                                                                      DO NOT                                                                              E5CN-H (48 x 48 mm)
                                                          9   17 USE
                          Auxiliary output 1
                                                              18 DO NOT A            DO NOT
                                                          10          USE
                                                                                     USE        mA

                                                              19                 B

                                                              20                 B   V DO NOT        A heater burnout alarm, heater short alarm,
                                                                                                     heater overcurrent alarm, or input alarm is
                                                                                                USE  sent to the output to which the alarm 1
                                                                                                     function is assigned.
                                                                  TC/Pt multi-input Analog input

Auxiliary output
      1, 2, 3

Relay outputs

250 VAC, 3 A

(resistive load)

                                                                                                                                                          E5AN-H (96 x 96 mm)
                                                                                                                                                             E5EN-H (48 x 96 mm)

                                                                                                                                                          Operation

                                                                                                                                                          Safety Precautions

                                                                                                                                                          27
                        E5AN/E5EN

                        Nomenclature

E5CN                    E5AN                                                                                                              E5EN
   E5CN-U (48 x 48 mm)
                                              Temperature unit

                                                            SUB1                                PV                                        Operation indicators  SUB1 SUB2
                                                            SUB2                                                                             Temperature unit   HA SUB3
                                                            SUB3                                                  No.1 display
                        Operation indicators                HA                                                                                                                           PV
                                                                                                                                                                                                  No.1 display

                                                                                                SV                                                                                       SV  No.2 display

                                                                                                                 No. 2 display

E5AN (96 x 96 mm)                                           OUT1  STOP                          MV        No. 3 display                                         OUT1 STOP                MV No.3 display
   E5EN (48 x 96 mm)                                                                                                                                            OUT2 CMW MANU
                                                            OUT2  CMW MANU                                                                Operation indicators

                        Programmable                                                                                                            Mode Key                                     Up Key
                        Function Key/                                                                                                           Level Key
                        Auto/Manual Key            PF                                                      Up Key                                                              PF            Programmable
                                                                                                          Down Key
                                                       A/M                                                                                                                     A/M           Function Key/

                                              E5AN                                                                                                                                           Auto/Manual Key

                                                                                                                                                                E5EN

                                              Level Key                         Mode Key                                                                                       Down Key

E5CN-H (48 x 48 mm)      A 2-level display when shipped from the factory. A 3-level display is activated if parameters are initialized. For details on the third display level,
                          refer to the User's Manual, Basic Type (Cat. No. H156).

                        Dimensions                                                                                                                                                           (Unit: mm)

                        E5AN

E5AN-H (96 x 96 mm)                                                                                                                       Mounted Separately                         Group Mounted
   E5EN-H (48 x 96 mm)
                                                                                                                                                      92+00.8                  (96 number of units - 3.5)+01.0

                                                                             6            79.2                                                                                                                                   92+00.8

                                                                                     2

                        96 96                                         112                               91                    120 min.                                 Group mounting does not allow waterproofing.

Operation                                                                                                                                                       92+00.8    Recommended panel thickness is 1 to
                                                                                                                                                                            8 mm.
                                                                        Waterproof      Mounting Bracket  Terminal Cover
                                                                        Packing         (Accessory)       (E53-COV16)                                                       Group mounting is not possible in the
                                                                        (Accessory)                       (Accessory)                                                       vertical direction. (Maintain the specified
                                                                                                                                                                            mounting space between Controllers.)
                                                                                                          Crimp terminal size: M3.5
                                                                                                                                                                            To mount the Controller so that it is
                                                                                                                                                                            waterproof, insert the waterproof packing
                                                                                                                                                                            onto the Controller.

                                                                                                                                                                            When two or more Controllers are
                                                                                                                                                                            mounted, make sure that the surrounding
                                                                                                                                                                            temperature does not exceed the
                                                                                                                                                                            allowable operating temperature specified
                                                                                                                                                                            in the specifications.

Safety Precautions

28
                                                                                                                         E5AN/E5EN

E5EN                                                                                                  Mounted Separately Group Mounted                                E5CN
                                                                                                                                                                         E5CN-U (48 x 48 mm)
                                       6                                                                        45+00.6  (48 number of units - 2.5)+10.0

                                                       79.2

          48                                   2

                                                                                                                                        92+00.8

      96                          112                                          91

                                                                                                      120 min.                  Group mounting does not
                                                                                                                                allow waterproofing.

                                  Waterproof   Mounting Bracket  Terminal Cover                                                         92+00.8                       E5AN (96 x 96 mm)
                                  Packing      (Accessory)       (E53-COV16)                                                                                             E5EN (48 x 96 mm)
                                  (Accessory)                    (Accessory)                           Recommended panel thickness is 1 to 8 mm.
                                                                                                       Group mounting is not possible in the vertical direction.
                                                                 Crimp terminal size: M3.5
                                                                                                       (Maintain the specified mounting space between
                                                                                                       Controllers.)                                                  E5CN-H (48 x 48 mm)
                                                                                                       To mount the Controller so that it is waterproof, insert the
                                                                                                       waterproof packing onto the Controller.
                                                                                                       When two or more Controllers are mounted, make sure that
                                                                                                       the surrounding temperature does not exceed the allowable
                                                                                                       operating temperature specified in the specifications.

Accessories (Order Separately)

USB-Serial Conversion Cable

E58-CIFQ1

                                                                                             (2,100)

                                                  250                              LED (SD)                              1,765

                                  USB connector (type A plug)                                LED (RD)                           Serial connector                      E5AN-H (96 x 96 mm)
                                                                                                                                                                         E5EN-H (48 x 96 mm)
Terminal Covers
                                                                      1.2 3.2
E53-COV16 (Six Covers provided.)                           10
                                               44.8
                                                                                                                                                                      Operation

                                                                                                                                                                      Safety Precautions

                                                                                                                                                                      29
                        E5AN/E5EN

E5CN                    Waterproof Packing                                                        Y92S-P5 (for DIN 48 96)                                 Order the Waterproof Packing separately if it becomes lost or
   E5CN-U (48 x 48 mm)                                                                                                                                      damaged.
                        Y92S-P4 (for DIN 96 96)                                                                                                           The Waterproof Packing can be used to achieve an IP66 degree of
                                                                                                                                                            protection.
E5AN (96 x 96 mm)                                                                                                                                           (Deterioration, shrinking, or hardening of the waterproof packing may
   E5EN (48 x 96 mm)                                                                                                                                        occur depending on the operating environment. Therefore, periodic
                                                                                                                                                            replacement is recommended to ensure the level of waterproofing
                                                                                                                                                            specified in IP66. The time for periodic replacement depends on the
                                                                                                                                                            operating environment. Be sure to confirm this point at your site.
                                                                                                                                                            Consider one year a rough standard. OMRON shall not be liable for
                                                                                                                                                            the level of water resistance if the customer does not perform periodic
                                                                                                                                                            replacement.)
                                                                                                                                                            The Waterproof Packing does not need to be attached if a waterproof
                                                                                                                                                            structure is not required.

                        Current Transformers                                                      21                               2.8                      E54-CT1
                                                                                                                                              7.5
                        E54-CT1                                                                   15    5.8 dia.                                            Thru-current (Io) vs. Output Voltage
                                                                                                                                                            (Eo) (Reference Values)
E5CN-H (48 x 48 mm)                                                                    25 3
                                                                                                                                                            Maximum continuous heater current: 50 A (50/60 Hz)
                                                                                              10                                                            Number of windings: 4002
                                                                                                                                                            Winding resistance: 182
                        E54-CT3
                                                                                                                           10.5                             Output voltage (Eo) V (r.m.s.)    100 V 50 Hz                              Distortion
                                                                                       40 40                                                                                                    10                                   factor 10%
                                                                                                  40                                                                                               1       1 k
                                                                                                                    Two, 3.5 dia.                                                                                                      3%
                                                                                                                                                                                            100 mV                                 1%

                                                                                                    30                                                                                      10                           100

E5AN-H (96 x 96 mm)                                                                                                                  2.36 dia.                                              1                         RL = 10
   E5EN-H (48 x 96 mm)                                                                            30
                                                                                                                                                                                            100 V
                                                                                                                   12 dia.
                                                                                                                                                         9

                                                                                                                                                                                            10

                                                                                                                                                                                            1              10 100 mA 1         10  100 1,000 A

                                                                                                                                                                                                                         Thru-current (Io) A (r.m.s.)

Operation                                                                                  Two, M3 (depth: 4)                                               E54-CT3
                                                   15
                                                                                                                                                            Thru-current (Io) vs. Output Voltage
                                                                           30
                                                                                                                                                            (Eo) (Reference Values)

                                                                                                                                                            Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                                                                                            (Maximum continuous heater current for an OMRON
                                                                                                                                                            Temperature Controller is 50 A.)
                                                                                                                                                            Number of windings: 4002
                                                                                                                                                            Winding resistance: 80.8

                        E54-CT3 Accessory                                                         Connection Example                                        Output voltage (Eo) V (r.m.s.)  100 V 50 Hz                               Distor-
                                                                                                                                                                                               10                                     tion
                         Armature                                                                               Armature                                                                       1          1 k                       factor
                                                                                                                                                                                                                                      10%
                         Approx. 3 dia.                                                           Plug                                                                                                     500
                                                                                                                                                                                                                                     3%
                                                                                                                                                                                                                                   1%

                                                                                                                                   Lead

Safety Precautions       Plug               18                                                                                                                                             100 mV                        100
                                        (22)                                                                                                                                                      10                     50
                        Approx. 6 dia.                                                                                                                                                             1
                                                                                                                                                                                                                         RL = 10

                                                                                                                                                                                            100 V         10 100 mA  1        10  100 1,000 A

                                                                                                                                                                                                 10
                                                                                                                                                                                                    1

                                                                                                                                                                                                                         Thru-current (Io) A (r.m.s.)

30
Advanced Digital Temperature Controller                                                                                         E5CN
                                                                                                                                   E5CN-U (48 x 48 mm)
E5CN-H (48 x 48 mm)

A New High-performance Controller: High Resolution, High Speed, and

High Input Accuracy.

Logic Operations and Preventive

Maintenance Function.                                                                                                           E5AN (96 x 96 mm)
                                                                                                                                   E5EN (48 x 96 mm)
High-resolution display with 5 digits/0.01C display in a compact
  Controller (48 x 48 mm).                                                                      48 48 mm                                   E5CN-H (48 x 48 mm)
                                                                                                  E5CN-H
High-speed sampling cycle of 60 ms.
High Accuracy                                                                     Refer to Safety Precautions on page 66.

  Thermocouple/Pt input: 0.1% of PV
  Analog input: 0.1% FS
Universal inputs on all models (thermocouple, PT, or analog input)
  to handle various sensors with one Controller.
A PV/SV-status display function can be set to automatically alternate
  between displaying the status of the Temperature Controller (auto/
  manual, RUN/STOP, and alarms) and the PV or SV.
Flexible contact outputs with logic operations (AND, OR, and delays)
  set from the Support Software (CX-Thermo Ver. 4.0)
Preventive maintenance for relays in the Temperature Controller
  using a Control Output ON/OFF Counter.

Main I/O Functions                                                                                                              E5AN-H (96 x 96 mm)
                                                                                                                                   E5EN-H (48 x 96 mm)
                               Event Inputs  E5CN-H
                               None
                               Two                 2-level Display: PV and SV 5-digit Display with high resolution of 0.01C

Universal Sensor Inputs                                          Auxiliary Outputs   Auto/manual switching
Universal thermocouple/Pt/analog                               Two               Temperature Controller status display
                                                                                     Simple program function
   (current/voltage) inputs.                 Control Output 2                        Logic operations                          Operation
                                              None                                  Control output ON/OFF count alarm
Indication Accuracy                           Voltage output                        PV change rate alarm
Thermocouple/Pt input: 0.1% of PV                                                 Models also available with RS-485 or
Analog input: 0.1% FS                      (for driving SSR)
                                                                                      RS-232C communications
Sampling Period
60 ms                                     Control Output 1
                                              Relay output
                                              Voltage output (for driving SSR)                                                              Safety Precautions
                                              Current output
                                              Linear voltage output

This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157)
E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159)

                                                                               31
                        E5CN-H

                        Lineup

E5CN                                                                                    1 control output                                   2 auxiliary outputs
   E5CN-U (48 x 48 mm)
                        E5CN-H         Terminal block            Fully universal input

                        Advanced Type                                                   2 control outputs 2 auxiliary outputs

                        Note: Models with one control output and models with two control outputs can be used for heating/cooling control.

                        Model Number Structure

E5AN (96 x 96 mm)       Model Number Legend                      Option Units
   E5EN (48 x 96 mm)
                        Controllers

E5CN-H (48 x 48 mm)     E5CN-@@@M@-@-500                         E53-@@@@

E5AN-H (96 x 96 mm)                    12345 6 7                            1234
   E5EN-H (48 x 96 mm)
                        1. Type                                  1. Applicable Controller
                            H: Advanced                              CN: E5CN-H or E5CN

                        2. Control Output 1                      2. Function 1
                            R: Relay output                          Blank: None
                            Q: Voltage output (for driving SSR)      Q: Control output 2 (voltage output for driving SSR)
                            C: Current output                        P: Power supply for sensor
                            V: Linear voltage output                 C: Current output

                        3. Auxiliary Outputs                     3. Function 2
                            2: Two outputs                           Blank: None
                                                                     H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
                        4. Option 1                                  HH: Heater burnout/SSR failure/Heater overcurrent detection
                            M: Option Unit can be mounted.                 (CT2)
                                                                     B: Two event inputs
                        5. Power Supply Voltage                      03: RS-485 communications
                            Blank: 100 to 240 VAC                    H03: Heater burnout/SSR failure/Heater overcurrent detection
                            D: 24 VAC/VDC                                   (CT1) + RS-485 communications
                                                                     HB: Heater burnout/SSR failure/Heater overcurrent detection
                        6. Case Color                                      (CT1) + Two event inputs
                            Blank: Black                             HH03: Heater burnout/SSR failure/Heater overcurrent detection
                            W: Silver                                         (CT2) + RS-485 communications
                                                                     H01: Heater burnout/SSR failure/Heater overcurrent detection
                        7. Terminal Cover                                   (CT1)/RS-232C communications
                            -500: With terminal cover                F: Transfer output
                                                                     BF: Two event inputs/Transfer output

                                                                 4. Version
                                                                     N2: Available only to models released after January 2008

                        Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@).

Operation

Safety Precautions

32
                                                                                                                                         E5CN-H

Ordering Information

Controllers                                                                                                                                                      E5CN
                                                                                                                                                                    E5CN-U (48 x 48 mm)
          Size       Case Color      Power supply voltage                Auxiliary output                 Control output 1                            Model
                Black            100 to 240 VAC                       2                       Relay output                               E5CN-HR2M-500
1/16 DIN        Silver                                                                        Voltage output (for driving SSR)           E5CN-HQ2M-500
48 48 78                     24 VAC/VDC                           2                       Current output                             E5CN-HC2M-500
(W H D)                      100 to 240 VAC                       2                       Linear voltage output                      E5CN-HV2M-500
                                 24 VAC/VDC                           2                       Relay output                               E5CN-HR2MD-500
                                                                                              Voltage output (for driving SSR)           E5CN-HQ2MD-500          E5AN (96 x 96 mm)
                                                                                              Current output                             E5CN-HC2MD-500             E5EN (48 x 96 mm)
                                                                                              Linear voltage output                      E5CN-HV2MD-500
                                                                                              Relay output                               E5CN-HR2M-W-500
                                                                                              Voltage output (for driving SSR)           E5CN-HQ2M-W-500
                                                                                              Current output                             E5CN-HC2M-W-500
                                                                                              Relay output                               E5CN-HR2MD-W-500
                                                                                              Voltage output (for driving SSR)           E5CN-HQ2MD-W-500
                                                                                              Current output                             E5CN-HC2MD-W-500

Option Units

One of the following Option Units can be mounted to provide the E5CN with additional functions.

                                                               Functions                                                                              Model
                                                                                                                                                E53-CNHH03N2
Communications                   3-phase heater burnout/SSR failure/                                                                            E53-CNHBN2       E5CN-H (48 x 48 mm)
RS-485                           Heater overcurrent detection                                                                                   E53-CNQ03N2
                                                                                                                                                E53-CNH03N2
                                 Heater burnout/SSR failure/                   Event inputs                                                     E53-CN03N2
                                 Heater overcurrent detection                                                                                   E53-CNBN2
                                                                                                                                                E53-CNQHN2
Communications                                                                               Control output 2                                   E53-CNQHHN2
RS-485                                                                                       (Voltage for driving SSR)                          E53-CNQBN2
                                                                                                                                                E53-CNQFN2
Communications                   Heater burnout/SSR failure/                                                                                    E53-CNBFN2
RS-485                           Heater overcurrent detection                                                                                   E53-CNQ01N2
                                                                                                                                                E53-CN01N2
Communications                                                                                                                                  E53-CNH01N2
RS-485

                                                                               Event inputs

                                 Heater burnout/SSR failure/                                 Control output 2
                                 Heater overcurrent detection                                (Voltage for driving SSR)

                                 3-phase heater burnout/SSR failure/                         Control output 2                                                    E5AN-H (96 x 96 mm)
                                 Heater overcurrent detection                                (Voltage for driving SSR)                                              E5EN-H (48 x 96 mm)

                                                                               Event inputs  Control output 2
                                                                                             (Voltage for driving SSR)

                                                                                             Control output 2           Transfer Output
                                                                                             (Voltage for driving SSR)

                                                                               Event inputs                             Transfer Output

                Communications                                                               Control output 2
                RS-232C                                                                      (Voltage for driving SSR)

                Communications
                RS-232C

                Communications Heater burnout/SSR failure/

                RS-232C          Heater overcurrent detection

Note: These Option Units are applicable only to models released after January 2008.

Accessories (Order Separately)                                                       Adapter                                                                     Operation

USB-Serial Conversion Cable

                                                Model                                        Connectable models                          Model
                                             E58-CIFQ1
                                                                                     Terminal type                                       Y92F-45
Terminal Cover
                                                                                     Note: Use this Adapter when the panel has been previously prepared for the
                                                Model                                        E5B@.
                                            E53-COV17
Note: 1. The Terminal Cover comes with the E5CN-@@@-500 models.                      CX-Thermo Support Software
        2. The E53-COV10 cannot be used.
                                                                                                                             Model                               Safety Precautions
Waterproof Packing                                                                                                      EST2-2C-MV4

                                                Model

                                              Y92S-29

Note: Waterproof Packing is included with the controller only for models with
        terminal blocks.

Current Transformers (CTs)

Hole diameter                     Model
     5.8 dia.                    E54-CT1
    12.0 dia.                    E54-CT3

                                                                                                                                                                 33
                        E5CN-H

                        Specifications

E5CN                    Ratings
   E5CN-U (48 x 48 mm)
                        Power supply voltage           No D in model number: 100 to 240 VAC, 50/60 Hz
                                                       D in model number: 24 VAC, 50/60 Hz; 24 VDC

                        Operating voltage range        85% to 110% of rated supply voltage

                        Power consumption              100 to 240 VAC: 8.5 VA (max.) (E5CN-HR2 at 100 VAC: 3.0 VA)
                                                       24 VAC/VDC: 5.5 VA (24 VAC)/3.5 W (24 VDC) (max.) (E5CN-HR2D at 24 VAC: 2.7 VA)

                        Sensor input                   Any of the following can be selected (i.e., fully universal input).
                                                       Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
E5AN (96 x 96 mm)                                      Platinum resistance thermometer: Pt100 or JPt100
   E5EN (48 x 96 mm)                                   Current input: 4 to 20 mA or 0 to 20 mA
                                                       Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

                        Input impedance                Current input: 150  max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB.)

                        Control method                 ON/OFF control or 2-PID control (with auto-tuning)

                                  Relay output         SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA

                                      Voltage output   Output voltage: 12 VDC 15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
                        Control (for driving SSR)      4 to 20 mA DC/0 to 20 mA DC, load: 600  max., resolution: approx. 10,000
                        output Current output

                                  Linear voltage out-  0 to 10 VDC (load: 1 k min.), Resolution: Approx. 10,000
                                  put

                        Auxilia- Number of outputs 2 max.

E5CN-H (48 x 48 mm)     ry        Output specifica- Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable

                        output tions                   load: 5 V, 10 mA

                                  Number of outputs 2

                        Event     External contact     Contact input: ON: 1 k max., OFF: 100 k min.
                        input     input specifica-     Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
                                  tions                Current flow: Approx. 7 mA per contact

                                  Number of opera-     8 max. (Combinations can be made using work bits.)
                                  tions

                                                       Logic operation: Any of the following four patterns can be selected. The input status may be inverted.

                                                                         (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B,

                        Logic     Operations                             C, and D are four inputs.)
                        opera-
E5AN-H (96 x 96 mm)     tions                           Delay:          ON delay or OFF delay for the results of the logic operation given above.
   E5EN-H (48 x 96 mm)
                                                                         Setting time: 0 to 9999 s or 0 to 9999 min

                                                       Output inversion: Possible

                                  Outputs              One work bit per operation

                                  Work bit assign- Any of the following can be assigned to up to eight work bits (logic operation results): Event input operations,

                                  ments                auxiliary outputs, or control outputs.

                        Transfer  Number of outputs 1 max.

                        outputs Output                 Current output: 4 to 20 mA DC, Load: 600  max., Resolution at 4 to 20 mA: Approx. 10,000
                                      specifications

                        RSP input                      Not supported

                        Setting method                 Digital setting using front panel keys

                        Indication method              11-segment digital display and individual indicators (7-segments displays also possible)
                                                       Character height: PV: 11 mm, SV: 6.5 mm
Operation
                        Bank switching                 Supported (number of banks: 8)
                                                       Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.)

                        Other functions                Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout
                                                       detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop,
                                                       protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, PV/SV
                                                       status display, logic operations, automatic cooling coefficient adjustment

                        Ambient operating tempera-     -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C
                        ture

Safety Precautions      Ambient operating humidity 25% to 85%

                        Storage temperature            -25 to 65C (with no condensation or icing)

                         For models with current outputs, control output 1 can be used as a transfer output.

34
                                                                                                                                                                                                                                           E5CN-H

Input Ranges                                                                                                                                                                                                                                                        E5CN
                                                                                                                                                                                                                                                                       E5CN-U (48 x 48 mm)
Thermocouple/Platinum Resistance Thermometer/Analog Input (Fully Universal Inputs)

Input type                       Platinum resistance                                                                                    Thermocouple                                                                                       Analog
                                      thermometer                                                                                                                                                                                           input

                        Name     Pt100                         JPt100                 K                     J              T                      EL              U            N        R  S     B      W                   PL  II   4 to   0 to  1 to  0 to  0 to
                                                                                                                                                                                                                                    20 mA  20 mA  5V    5V    10 V

                        2300                                                                                                                                                                                        2300.0
                        1800                                                                                                                                                                              1800.0
                        1700                                                                                                                                                            1700.01700.0

                        1600

                        1500

                        1400                                                  1300.0                                                                                           1300.0                                       1300.0
                        1300
Temperature range (C)                                                                                                                                                                                                                                              E5AN (96 x 96 mm)
                        1200                                                                                                                                                                                                                                           E5EN (48 x 96 mm)

                        1100                                                                         850.0                                                850.0                                                                     Usable in the following
                        1000
                                                                                                                                                  600.0                                                                             ranges by scaling:
                                850.0
                         900                                                                                                                                                                                                        -19999 to 32400,
                         800                                                                                                                                                                                                        -1999.9 to 3240.0,
                         700                                                                                                                                                                                                        -199.99 to 324.00, or
                         600                                                                                                                                                                                                        -19.999 to 32.400

                                         500.0                 500.0                  500.0
                         500
                         400                                                                                400.0          400.0 400.0                            400.0 400.0

                        300                            200.00                                200.00                200.00                 200.00

                        200                     100.0                  100.0

                        100                                                                                                                                                                      100.0

                              0                 0.0                    0.0                                                                                                              0.0 0.0         0.0 0.0                                                     E5CN-H (48 x 48 mm)

                        -100                           -50.00                         -20.0 -50.00-100.0 -20.0 -50.00                     -50.00          -100.0

                        -200     -200.0 -199.9                 -199.9         -200.0                                       -200.0 -199.9          -200.0          -200.0 -199.9 -200.0

Setting                          0 1 2 24 3 4 5 6 21 7 8 22 9 10 23 11 12 13 14 15 16 17 18 19 20 25 26 27 28 29
number

Shaded settings are the default settings.                                                                                                 JPt100: JIS C 1604-1989, JIS C 1606-1989
The applicable standards for the input types are as follows:                                                                              Pt100: JIS C 1604-1997, IEC 751
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1                                                                                        PL II: According to Platinel II electromotive force charts from BASF (previously
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985                                                                                                                       Engelhard)
W: W5Re/W26Re, ASTM E988-1990

                                                                                                                                                                                                                                                                    E5AN-H (96 x 96 mm)
                                                                                                                                                                                                                                                                       E5EN-H (48 x 96 mm)

                                                                                                                                                                                                                                                                    Operation

                                                                                                                                                                                                                                                                    Safety Precautions

                                                                                                                                                                                                                                                              35
                        E5CN-H

E5CN                    Alarm Outputs
   E5CN-U (48 x 48 mm)
                        Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit.
                        Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.

                        Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the
                                following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR
                                failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function).

                         Set                           Alarm output operation                    1. With set values 1, 4 and 5, the upper and lower limit values can
                        value                                                                         be set independently for each alarm type, and are expressed as
                               Alarm type              When X is              When X is               "L" and "H."
                                                        positive               negative
                                                                                                 2. Set value: 1, Upper- and lower-limit alarm

E5AN (96 x 96 mm)       0      Alarm function    Output OFF                                      Case 1          Case 2             Case 3 (Always ON)
   E5EN (48 x 96 mm)           OFF
                                                                                                                                                                                             H < 0, L < 0
                        1 Upper- and lower- ON            LH                                         L H SP      SP L H               H SP L
                                                                                                                                    H L SP                                                   H < 0, L > 0
                        1 limit                  OFF                     2                       H < 0, L > 0    H > 0, L < 0                                                                H  L
                                                                     SP                          H < L           H > L                                                                       H > 0, L < 0
                                                                                                                                                                                             H  L
                                                 ON           X          ON   X
                                                 OFF      SP
                        2 Upper limit                                    OFF                                                                                                         SP H L
                                                                                             SP
                                                                                                 3. Set value: 4, Upper- and lower-limit range
                                                 ON       X              ON       X
                                                                         OFF  SP
                        3 Lower limit            OFF
                                                                     SP
                                                                                                 Case 1                             Case 3 (Always OFF)
                        4 Upper- and lower- ON            LH                                                     Case 2                    H SP L                                            H < 0, L < 0
                                                                                                        L H SP
                        1 limit range            OFF                     3                         H < 0, L > 0    SP L H               H L SP                                               H < 0, L > 0
                                                                     SP                             H < L           H > 0, L < 0                                                             H  L
                                                                                                                    H > L
E5CN-H (48 x 48 mm)     5      Upper- and lower- ON       LH
                                                           SP
                        1      limit with standby OFF                    4

                               sequence          5                                                                                  SP H L                                                   H > 0, L < 0
                                                                                                                                                                                             H  L

                               Upper-limit with  ON           X          ON   X
                                                          SP
                        6      standby sequence OFF                      OFF                     4. Set value: 5, Upper- and lower-limit with standby sequence
                                                                                             SP       For Upper- and Lower-Limit Alarm Described Above

                        7      Lower-limit with  ON       X              ON          X            Case 1 and 2
                                                           SP            OFF     SP               Always OFF when the upper-limit and lower-limit hysteresis
                               standby sequence OFF                                               overlaps.

                        8      Absolute-value    ON         X            ON      X                Case 3: Always OFF
                               upper-limit       OFF   0                 OFF          0

                        9      Absolute-value    ON         X            ON      X               5. Set value: 5, Upper- and lower-limit with standby sequence
                               lower-limit       OFF   0                 OFF          0               Always OFF when the upper-limit and lower-limit hysteresis
                                                                                                      overlaps.
                               Absolute-value                            ON      X
                                                 ON          X           OFF          0
E5AN-H (96 x 96 mm)                              OFF
   E5EN-H (48 x 96 mm)  10 upper-limit with

                               standby sequence        0

                               Absolute-value    ON          X           ON      X
                                                 OFF                     OFF          0
                        11 lower-limit with

                               standby sequence        0

                        12     LBA (for alarm 1  ---
                               only)

                        13     PV change rate    ---
                               alarm

Operation

Safety Precautions

36
                                                                                                                           E5CN-H

Characteristics                                                                                                                                     E5CN
                                                                                                                                                       E5CN-U (48 x 48 mm)
Indication accuracy       Thermocouple: (0.1% of indicated value or 1C, whichever is greater) 1 digit max. 1
                          Platinum resistance thermometer: (0.1% of indicated value or 0.5C, whichever is greater) 1 digit max.
                          Analog input: 0.1% FS 1 digit max.
                          CT input: 5% FS 1 digit max.

Transfer output accuracy 0.3% FS max.

Influence of temperature  Thermocouple input (R, S, B, W, PLII): (1% of PV or 10C, whichever is greater) 1 digit max.
2                         Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. 3
                          Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max.
Influence of voltage 2    Analog input: (1%FS) 1 digit max.

Input sampling period 60 ms                                                                                                                         E5AN (96 x 96 mm)
                                                                                                                                                       E5EN (48 x 96 mm)
Hysteresis                Temperature input: 0.1 to 3240.0C or F (in units of 0.1C or F)
                          Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)

Proportional band (P)     Temperature input: 0.1 to 3240.0C or F (in units of 0.1 C or F)
                          Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)

Integral time (I)         0.0 to 3240.0 s (in units of 0.1 s)

Derivative time (D)       0.0 to 3240.0 s (in units of 0.1 s)

Control period            0.5, 1 to 99 s (in units of 1 s)

Manual reset value        0.0 to 100.0% (in units of 0.1%)

Alarm setting range       -19999 to 32400 (decimal point position depends on input type)

Affect of signal source   Thermocouple: 0.1C/ max. (100  max.)                                                                                     E5CN-H (48 x 48 mm)
resistance                Platinum resistance thermometer: 0.1C/ max. (10  max.)

Insulation resistance     20 M min. (at 500 VDC)

Dielectric strength       2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)

Vibration Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions

Shock       Malfunction 100 m/s2, 3 times each in X, Y, and Z directions

resistance Destruction 300 m/s2, 3 times each in X, Y, and Z directions

Weight                    Controller: Approx. 150 g, Mounting Bracket: Approx. 10 g

Degree of protection      Front panel: IP66, Rear case: IP20, Terminals: IP00

Memory protection         Non-volatile memory (number of writes: 1,000,000 times)                                                                   E5AN-H (96 x 96 mm)
                                                                                                                                                       E5EN-H (48 x 96 mm)
Setup Tool                CX-Thermo version 4.0 or higher

Setup Tool port           Provided on the bottom of the E5CN-H. Use this port to connect a computer to the E5CN-H.
                          An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5CN-H. 4

Standards   Approved      UL 61010-1, CSA C22.2 No. 1010-1
            standards     EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II

            Conformed
            standards

                          EMI:                                                 EN 61326

                          Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A

                          Noise Terminal Voltage:                              EN 55011 Group 1, class A

                          EMS:                                                 EN 61326

                          ESD Immunity:                                        EN 61000-4-2                                                         Operation

EMC                       Electromagnetic Field Immunity:                      EN 61000-4-3

                          Burst Noise Immunity:                                EN 61000-4-4

                          Conducted Disturbance Immunity:                      EN 61000-4-6

                          Surge Immunity:                                      EN 61000-4-5

                          Power Frequency Magnetic Field Immunity:             EN 61000-4-8

                          Voltage Dip/Interrupting Immunity:                   EN 61000-4-11

1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U             Safety Precautions
     and L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max.
     is not specified. The indication accuracy of B thermocouples in the 400 to 800C range is 3C max. The indication accuracy of the R and S
     thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is 0.3 of PV or 3C,
     whichever is greater, 1 digit max. The indication accuracy of PL II thermocouples is 0.3 of PV or 2C, whichever is greater, 1 digit max.

2. Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage
3. K thermocouple at -100C max.: 10C max.
4. External communications (RS-232C or RS-485) and cable communications for the Setup Tool can be used at the same time.

                                                                                                                                     37
                        E5CN-H

E5CN                    USB-Serial Conversion Cable                                                Current Transformer (Order Separately)
   E5CN-U (48 x 48 mm)                                                                             Ratings
                        Applicable OS              Windows 2000, XP, or Vista

                        Applicable software        Thermo Mini, CX-Thermo version                  Dielectric strength                                      1,000 VAC for 1 min
                                                   4.0 or higher
                                                                                                   Vibration resistance                                     50 Hz, 98 m/s2

                        Applicable models          E5AN/E5EN/E5CN/E5CN-U/                          Weight                                                   E54-CT1: Approx. 11.5 g,
                                                   E5AN-H/E5EN-H/E5CN-H                                                                                     E54-CT3: Approx. 50 g

                        USB interface standard     Conforms to USB Specification 1.1.              Accessories (E54-CT3 only)                               Armatures (2)
                                                                                                                                                            Plugs (2)
                        DTE speed                  38400 bps

E5AN (96 x 96 mm)       Connector specifications   Computer: USB (type A plug)                     Heater Burnout Alarms, SSR Failure
   E5EN (48 x 96 mm)                               Temperature Controller: Setup Tool              Alarms, and Heater Overcurrent Alarms
                                                   port (on bottom of Controller)

                        Power supply               Bus power (Supplied from USB                                                                          Models with detection for single-
                                                   host controller.)                                                                                     phase heaters: One input
                                                                                                                                                         Models with detection for single-
                        Power supply voltage       5 VDC                                           CT input (for heater cur-                             phase or three-phase heaters: Two
                                                                                                   rent detection)                                       inputs
                        Current consumption        70 mA
                                                                                                   Maximum heater current                                50 A AC
                        Ambient operating tempera- 0 to 55C (with no condensation or              Input current indication
                                                                                                   accuracy                                              5% FS 1 digit max.
                        ture                       icing)                                          Heater burnout alarm set-
                                                                                                   ting range 1                                          0.1 to 49.9 A (in units of 0.1 A)
                        Ambient operating humidity 10% to 80%                                      SSR failure alarm setting                             Minimum detection ON time: 100 ms
                                                                                                   range 2
                        Storage temperature        -20 to 60C (with no condensation               Heater overcurrent alarm                              0.1 to 49.9 A (in units of 0.1 A)
                                                   or icing)                                       setting range 3                                       Minimum detection OFF time: 100 ms
E5CN-H (48 x 48 mm)
                        Storage humidity           10% to 80%                                                                                            0.1 to 49.9 A (in units of 0.1 A)
                                                                                                                                                         Minimum detection ON time: 100 ms
                        Altitude                   2,000 m max.

                        Weight                     Approx. 100 g

                        Note: A driver must be installed in the personal computer. Refer to        1. For heater burnout alarms, the heater current will be measured
                                installation information in the operation manual for the                when the control output is ON, and the output assigned to the
                                Conversion Cable.                                                       alarm 1 function will turn ON if the heater current is lower than the
                                                                                                        set value (i.e., heater burnout detection current value).
                        Communications Specifications
                                                                                                   2. For SSR failure alarms, the heater current will be measured when
E5AN-H (96 x 96 mm)     Transmission line RS-485: Multipoint                                            the control output is OFF, and the output assigned to the alarm 1
   E5EN-H (48 x 96 mm)  connection method RS-232C: Point-to-point                                       function will turn ON if the heater current is higher than the set
                                                                                                        value (i.e., SSR failure detection current value).
                        Communications RS-485 (two-wire, half duplex)/RS-232C
                                                                                                   3. For heater overcurrent alarms, the heater current will be
                        Synchronization      Start-stop synchronization                                 measured when the control output is ON, and the output assigned
                        method                                                                          to the alarm 1 function will turn ON if the heater current is higher
                                                                                                        than the set value (i.e., heater overcurrent detection current
                        Protocol             CompoWay/F, SYSWAY, or Modbus                              value).

                        Baud rate            1200, 2400, 4800, 9600, 19200, 38400, or
                                             57600 bps

                        Transmission code    ASCII (CompoWay/F, SYSWAY)                            Electrical Life Expectancy Curve for
                                             RTU (Modbus)                                          Relays (Reference Values)

                        Data bit length  7 or 8 bits

                        Stop bit length  1 or 2 bits                                               Life ( 104 operations)  500
                                                                                                                            300
                                             Vertical parity (none, even, odd)
Operation               Error detection      Frame check sequence (FCS) with SYSWAY                                         100
                                             Block check character (BCC) with
                                             CompoWay/F or CRC-16 Modbus                                                     50
                                                                                                                             30
                        Flow control         None

                        Interface            RS-485, RS-232C

                        Retry function       None                                                                           10

                        Communications       217 bytes                                                                      5       E5CN-H
                        buffer
                                                                                                                                    250 VAC, 30 VDC
                                                                                                                            3
                        Communications 0 to 99 ms                                                                                   (resistive load)
                        response wait time Default: 20 ms
Safety Precautions                                                                                                                  cos = 1

                                                                                                                            1

                         The baud rate, data bit length, stop bit length, and vertical parity can                                0  1        2        3  4  5  6
                          be individually set using the Communications Setting Level.
                                                                                                                                                         Switching current (A)

38
                                                                                                                                                E5CN-H

External Connections

A voltage output (control output, for driving SSR) is not electrically insulated from the internal circuits. When using a grounding thermocouple,              E5CN
   do not connect any of the control output terminals to ground. If the control output terminals are connected to ground, errors will occur in the                   E5CN-U (48 x 48 mm)
   measured temperature values as a result of leakage current.

Controllers

Control output 1

Relay output

250 VAC, 3 A                                                                                         Auxiliary outputs Auxiliary outputs (relay outputs)

(resistive load)                                                                                     (relay outputs) 250 VAC, 3 A

Voltage output                                                        1         11               6                            (resistive load)

(for driving SSR)                                Control output 1                                         Auxiliary output 2                                      E5AN (96 x 96 mm)
12 VDC, 21 mA                                                                2                                                                                       E5EN (48 x 96 mm)
                                                                                12               7                            A heater burnout alarm, SSR

Linear voltage output                 DO NOT DO NOT A                                                Auxiliary output 1       failure, heater overcurrent alarm,

0 to 10 VAC                           USE              USE            3         13               8        ?                   or input alarm is sent to the

Load 1 k max.                mA                             B4                                                                output to which the alarm 1

Current output                                                                  14               9                            function is assigned.

0 to 20 mA DC                                 V             B5                                       Input power supply       100 to 240 VAC
4 to 20 mA DC                    DO NOT                                                                                        24 VAC/VDC (no polarity)
Load 600  max.                   USE                                            15               10

Option Units                     E53-CNQBN2                                     E53-CNHBN2                E53-CNBFN2                                              E5CN-H (48 x 48 mm)

               E53-CNBN2         Event Inputs and                               Event Inputs              Event Inputs and
               Event Inputs      Control Output 2                               and CT                    Transfer Output

              11                                 11                             11                             11

     EV1 12                           EV1 12                                    EV1 12                    EV1 12

EV2           13                 EV2             13                   EV2       13                   EV2       13

DO NOT 14                    Control output 2 14                                     14                        14        4 to 20 mA DC
USE                          12 VDC 21 mA 15                                                                             (Load 600  max.)
                                                                      CT1                        Transfer output
DO NOT 15                                                                            15                              15                                           E5AN-H (96 x 96 mm)
USE                                                                                                                                                                  E5EN-H (48 x 96 mm)

E53-CNQHHN2                      E53-CNQFN2                                     E53-CN01N2               E53-CNH01N2               E53-CNQ01N2
Control Output 2                 Control Output 2 and                                                    Communications            Communications (RS-232)
and CT2                          Transfer Output                       Communications                    (RS-232) and CT           and Control Output 2
                                                                       (RS-232)                         RS-232C
Control output 2 11          Control output 2 11                      RS-232C                                                           RS-232C
12 VDC 21 mA                 12 VDC 21 mA                                                                    SD 11                           SD 11
                                                                           SD 11
                     12                            12                                                        RD 12                           RD 12
                                                                                RD 12
                                                                                                             SG 13                           SG 13
              13                 DO NOT          13                             SG 13
                                 USE                                                                                14        Control output 2 14
                                                                                                     CT1                      12 VDC 21 mA
CT2           14                                 14                   DO NOT    14
                                                                      USE                                           15                             15
     CT1                     Transfer output           4 to 20 mA DC
                                                15     (Load 600      DO NOT                                                                                      Operation
              15                                       max.)          USE       15

     E53-CN03N2                  E53-CNQ03N2                                    E53-CNH03N2          E53-CNHH03N2                          E53-CNQHN2

     Communications              Communications (RS-485)                        Communications       Communications                        Control Output 2
     (RS-485)                    and Control Output 2                           (RS-485) and CT      (RS-485) and CT2                      and CT

   B (+) 11                           B (+) 11                                  B (+) 11                 B (+) 11             Control output 2 11
RS-485                                                                                               RS-485                   12 VDC 21 mA
                                 RS-485                               RS-485                                                                                      Safety Precautions
                                                                                                         A (-) 12                                  12
     A (-) 12                         A (-) 12                                  A (-) 12
                                                                                                                 13
DO NOT        13                 DO NOT          13                   DO NOT    13                                            DO NOT            13
USE                              USE                                  USE                                                     USE

DO NOT        14             Control output 2 14                                    14               CT2       14                                  14
USE                          12 VDC 21 mA                                                                                                  CT1
                                                                      CT1                                 CT1
DO NOT                                            15                                15                                                             15
USE           15                                                                                               15

Note: Wire all voltage input terminals correctly. The Controller may fail if voltage input terminals are wired incorrectly.

                                                                                                                                                                  39
E5CN                    E5CN-H                                              Temperature unit
   E5CN-U (48 x 48 mm)
                        Nomenclature

                        E5CN-H

                                               Operation indicators    SUB1                                     No. 1 display
                                                            Level Key  SUB2                                     No. 2 display
                                                                       SUB3
                                                                       HA

                                                                       OUT1 STOP
                                                                       OUT2 CWM MANU

                                                                                                                Up Key

E5AN (96 x 96 mm)                                                                                   E5CN-H
   E5EN (48 x 96 mm)                                                          Mode Key Down Key

                        Dimensions                                                                                                                                   (Unit: mm)

                        E5CN-H                                                                                                 Panel Cutout

                                                                          91                                 Mounted Separately                         Group Mounted
                                                                       78
E5CN-H (48 x 48 mm)                                6                                                                                              (48 number of units - 2.5)+10.0
                                                         1.5
                                      48 48

                                                                                                                                                                                   45+00.6

                                               58                                     44.8 44.8 48.8 60 min.                                    Group mounting does not
                                                                                                                                                  allow waterproofing.

                                                                                                                                        Recommended panel thickness is 1 to

                                                                                                                               45+00.6    5 mm.  mounting  is  not  possible  in  the
                                                                                                                                           Group

                                               Waterproof   Mounting Adapter          Terminal Cover                                       vertical direction. (Maintain the specified
                                               Packing      (Accessory)               (E53-COV17)
                                               (Accessory)                            (Accessory)                                          mounting space between Controllers.)

                                                                                                                      45+00.6            To mount the Controller so that it is

                                                                                                                                           waterproof, insert the waterproof packing

                                                                                                                                           onto the Controller.

                                                                                                                                        When two or more Controllers are mounted,

                                                                       Note: The terminal block cannot be removed.                         make sure that the surrounding

E5AN-H (96 x 96 mm)                                                                                                                        temperature does not exceed the allowable
   E5EN-H (48 x 96 mm)
                                                                                                                                           operating temperature specified in the

                                                                                                                                           specifications.

                        Accessories (Order Separately)

                        USB-Serial Conversion Cable

                        E58-CIFQ1

                                                                                                             (2,100)

                                                                       250                    LED indicator                                       1,765
                                                                                              (SD)

Operation                                      USB connector (type A plug)                                      LED indicator (RD)                                   Serial connector

Safety Precautions

40
                                                                                                                                                                                               E5CN-H

Terminal Cover                                                                  Waterproof Packing                                                                                                                           E5CN
                                                                                                                                                                                                                                E5CN-U (48 x 48 mm)
E53-COV17                                                                       Y92S-29 (for DIN 48 48)

                         Note: The E53-COV10                                                                                        Order the Waterproof Packing separately if it becomes lost or                            E5AN (96 x 96 mm)
                                 can not be used.                                                                                   damaged.                                                                                    E5EN (48 x 96 mm)
                                                                                                                                    The Waterproof Packing can be used to achieve an IP66 degree of
                       48                                                                                                           protection.
48.8                                                                                                                                (Deterioration, shrinking, or hardening of the waterproof packing may
                                                                                                                                    occur depending on the operating environment. Therefore, periodic
22                                                                                                                                 replacement is recommended to ensure the level of waterproofing
                                                                                                                                    specified in IP66. The time for periodic replacement depends on the
                                                                                                                                    operating environment. Be sure to confirm this point at your site.
                                                                                                                                    Consider one year a rough standard. OMRON shall not be liable for
                                                                                                                                    the level of water resistance if the customer does not perform periodic
                                                                                                                                    replacement.)
                                                                                                                                    The Waterproof Packing does not need to be attached if a waterproof
                                                                                                                                    structure is not required.

     9.1                                                                  21                               2.8                      E54-CT1                                                                                  E5CN-H (48 x 48 mm)
                                                                          15                                          7.5           Thru-current (Io) vs. Output Voltage
Current Transformers                                                                                                                (Eo) (Reference Values)
                                                                                         5.8 dia.
E54-CT1                                                                                                                             Maximum continuous heater current: 50 A (50/60 Hz)
                                                                                                                                    Number of windings: 4002
                                                               25 3                                                                 Winding resistance: 182

                                                                      10                           10.5                             Output voltage (Eo) V (r.m.s.)  100 V 50 Hz

E54-CT3                                                                   40                                                                                              10                                 Distortion
                                                                                            Two, 3.5 dia.                                                                  1                                 factor 10%
                                                               40 40                                                                                                           1 k
                                                                                                                                                                    100 mV                                   3%
                                                                                                                                                                                                         1%                  E5AN-H (96 x 96 mm)
                                                                                                                                                                                                                                E5EN-H (48 x 96 mm)
                                                                           30                                                                                       10                         100

                                                                                                             2.36 dia.                                              1                       RL = 10
                                                                          30
                                                                                                                                                                    100 V
                                                                                           12 dia.
                                                                                                                                 9

                                                                                                                                                                    10

                                                                                                                                                                    1            10 100 mA 1         10  100 1,000 A

                                                                                                                                                                                               Thru-current (Io) A (r.m.s.)

                                                                   Two, M3 (depth: 4)                                               E54-CT3                                                                                  Operation
                           15                                                                                                       Thru-current (Io) vs. Output Voltage
                                                                                                                                    (Eo) (Reference Values)
                                                   30
                                                                                                                                    Maximum continuous heater current: 120 A (50/60 Hz)
                                                                                                                                    (Maximum continuous heater current for an OMRON
                                                                                                                                    Temperature Controller is 50 A.)
                                                                                                                                    Number of windings: 4002
                                                                                                                                    Winding resistance: 80.8

E54-CT3 Accessory                                                         Connection Example                                        Output voltage (Eo) V (r.m.s.)  100 V 50 Hz                             Distor-
                                                                                                                                                                       10                                   tion
Armature                                                                     Armature                                                                                 1        1 k                       factor
                                                                                                                                                                                                            10%
  Approx. 3 dia.                                                          Plug                                                                                                   500                                         Safety Precautions
                                                                                                                                                                                                           3%
                                                                                                                                                                                                         1%

                                                                                                           Lead

Plug                 18                                                                                                                                           100 mV                      100
                (22)                                                                                                                                                      10                   50
Approx. 6 dia.                                                                                                                                                             1
                                                                                                                                                                                               RL = 10

                                                                                                                                                                    100 V       10 100 mA  1        10  100 1,000 A

                                                                                                                                                                         10
                                                                                                                                                                            1

                                                                                                                                                                                               Thru-current (Io) A (r.m.s.)

                                                                                                                                                                                                                         41
                        E5CN-H

E5CN                    Adapter
   E5CN-U (48 x 48 mm)
                        Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@.

                                                                                                                   Fixture (Accessory)

                                                    4.7                                                        76

                                                              69.6 to 77.6

                                           72 72

                                                                                                                   67 67 87

E5AN (96 x 96 mm)       Mounted to E5CN-H                        Panel (1 to 8 mm)
   E5EN (48 x 96 mm)                                48 48
                                           72 72

E5CN-H (48 x 48 mm)                                 2.2  4.7

                                                         77.3 (to back of E5CN-H)

E5AN-H (96 x 96 mm)
   E5EN-H (48 x 96 mm)

Operation

Safety Precautions

42
Advanced Digital Temperature Controller                                                                                                          E5CN
                                                                                                                                                    E5CN-U (48 x 48 mm)
E5AN-H/E5EN-H(96 x 96 mm and 48 x 96 mm)

A New High-performance Controller: High Resolution, High Speed, and
High Input Accuracy.

Logic Operations and Preventive Maintenance Function. Plus Infrared

Port on Front Panel.                                                                                                                             E5AN (96 x 96 mm)
                                                                                                                                                    E5EN (48 x 96 mm)
High-resolution display with 5 digits/0.01C display.
High-speed sampling cycle of 60 ms.                                                 96 96 mm                       48 96 mm                E5CN-H (48 x 48 mm)
High Accuracy                                                                         E5AN-H                           E5EN-H

  Thermocouple/Pt input: 0.1% of PV                                                             Refer to Safety Precautions on page 66.
  Analog input: 0.1% FS
Universal inputs on all models (thermocouple, PT, or analog input)                                                                             E5AN-H (96 x 96 mm)
  to handle various sensors with one Controller. Models also                                                                                        E5EN-H (48 x 96 mm)
  available with Remote SP.
A PV/SV-status display function can be set to automatically
  alternate between displaying the status of the Temperature
  Controller (auto/manual, RUN/STOP, and alarms) and the PV or
  SV.
Flexible contact outputs with logic operations (AND, OR, and
  delays) set from the Support Software (CX-Thermo Ver. 4.0)
Preventive maintenance for relays in the Temperature Controller
  using a Control Output ON/OFF Counter.
Model available with position-proportional control

Main I/O Functions

                   Remote SP Input         E5AN-H            E5EN-H
                   One
                                                                                      3-level Display
                       Event Inputs                                                   Simultaneously displays set items, such as the
                        None                                                         PV, SV, and MV.
                        Two
                        Four                                                         5-digit Display with high resolution of 0.01C

Universal Sensor Inputs                                      Infrared port                          Auxiliary Outputs   Auto/manual switching   Operation
Universal thermocouple/                                    USB                                     Two               Temperature Controller
                                                                                                    Three
Pt/analog                                                                                                               status display
(current/voltage) inputs.                                                            Computer Support Software         Simple program
                                                                                      CX-Thermo
Indication Accuracy                                                                                                      function
Thermocouple/Pt input:                   Control Output 2                                                             Logic operations        Safety Precautions
                                                                                                                        Control output ON/OFF
   0.1% of PV                             (built-in)        Output Unit
Analog input:                                                                                                          count alarm
                                           SSR outputs Relay output                                                 PV change rate alarm
   0.1% FS                                                                                                             Models available with
                                                             Voltage output (for driving SSR)
Sampling Period                                                                                                          RS-485, RS-422, or
60 ms                                                                                                                  RS-232C
                                                                                                                         communications
                            PF Key
                            (Programmable                     Current output
                            key function)
                                                             Linear voltage output

                                           Control Output 1

                                           (built-in)        Output Unit

                                           SSR outputs Relay output

                                                             Voltage output (for driving SSR)

                                                             Current output

                                                             Linear voltage output

                                                                                                                                                 43
                        E5AN-H/E5EN-H

                        Lineup

E5CN                                                                                                                         1 control output   2 auxiliary outputs
   E5CN-U (48 x 48 mm)
                        E5AN-H/E5EN-H  Terminal block  Fully universal input

                        Advanced Type                                                                                        2 control outputs

                                                                                                                                                2 auxiliary outputs

                        Note: The Controller can be used for heating/cooling control even if only 1 control output is used.

                        Model Number Structure

E5AN (96 x 96 mm)       Model Number Legend                                                   Option Units
   E5EN (48 x 96 mm)
                        Controllers                                                           E53-@
E5CN-H (48 x 48 mm)
                        E5AN/E5EN-@@@@@@@M@-@-500                                                        1
E5AN-H (96 x 96 mm)
   E5EN-H (48 x 96 mm)                              1 2 3 4 5 6 7 8 9 10 11                   1. Function
                                                                                                  EN01: RS-232C communications
                        1. Type                                                                   EN02: RS-422 communications
                            H: Advanced                                                           EN03: RS-485 communications
                                                                                                  AKB: Event input
                        2. Control Mode
                            Blank: Standard or heating/cooling control                        Output Units
                            P: Position-proportional control
                                                                                              E53-@@
                        3. Control Output 1
                            A: Control Output Unit                                                       12
                            R: Relay output
                            S: SSR output                                                     1. Control Output
                                                                                                  R: Relay output
                        4. Control Output 2                                                       Q: Voltage output (for driving SSR)
                            A: Control Output Unit                                                Q3: Voltage output (for driving SSR) + 24 VDC (NPN)
                            R: Relay output                                                       Q4: Voltage output (for driving SSR) + 24 VDC (PNP)
                            S: SSR output                                                         C3: Current output + 4 to 20 mA DC
                                                                                                  C3D: Current output + 0 to 20 mA DC
                        5. Auxiliary Outputs                                                      V34: Linear voltage output + 0 to 10 VDC
                            2: Two outputs                                                        V35: Linear voltage output + 0 to 5 VDC
                            3: Three outputs
                                                                                              2. Version
                        6. Option 1                                                               Blank: Available for E5AN-H/E5EN-H and E5AK/E5EK.
                            Blank: None                                                           N: Available only for E5AN-H/E5EN-H.
                            H: Heater burnout/SSR failure/Heater overcurrent detection (CT1)
Operation                   HH: Heater burnout/SSR failure/Heater overcurrent detection
                                  (CT2)
Safety Precautions
                        7. Option 2
                            B: Two event inputs
                            BF: Event input + Transfer output

                        8. Option 3
                            M: Option Unit can be mounted.

                        9. Power Supply Voltage
                            Blank: 100 to 240 VAC
                            D: 24 VAC/VDC

                        10.Case Color
                            Blank: Black
                            W: Silver

                        11.Terminal Cover
                            -500: With Terminal Cover

                            This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
                            and other information required for operation before attempting to use the product.
                            E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157)
                            E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159)

                  44
                                                                                                             E5AN-H/E5EN-H

Ordering Information

E5AN-H                                                                                                                                       E5CN
                                                                                                                                                E5CN-U (48 x 48 mm)
              Case    Power    Control Auxiliary                              Heater     Optional functions
              color   supply   method output
Size                  voltage                        Control output 1/2       burnout Event Transfer       RSP         Model
                                                                                            inputs output

                                                     Control Output Unit 2  1       2                    4 to 20-mA  E5AN-HAA2HBM-500
                                                                                                           input

                                                     SSR outputs 2          1       2                    4 to 20-mA  E5AN-HSS2HBM-500
                                                     Control Output Unit 2                               input
                                                  2  SSR outputs 2
                                                     Control Output Unit 2  2       2  4 to 20-mA        4 to 20-mA  E5AN-HAA2HHBFM-500
                                    Basic            SSR outputs 2                     output            input
                      100 to
                      240 VAC                                                 2       2  4 to 20-mA        4 to 20-mA  E5AN-HSS2HHBFM-500
                                                                                         output            input
                                                  3
                                                                                      2  4 to 20-mA        4 to 20-mA  E5AN-HAA3BFM-500      E5AN (96 x 96 mm)
                                                                                         output            input                                E5EN (48 x 96 mm)

                                                                                      2  4 to 20-mA        4 to 20-mA  E5AN-HSS3BFM-500
                                                                                         output            input

                                                     Relay outputs 2                2                    4 to 20-mA  E5AN-HPRR2BM-500
                                                     Relay outputs 2                                     input
                               Valve 2               Control Output Unit 2
                                                     SSR outputs 2                     4 to 20-mA        4 to 20-mA
                                                     Control Output Unit 2          2  output            input       E5AN-HPRR2BFM-500
                                                     SSR outputs 2
              Black                                  Control Output Unit 2                               4 to 20-mA
                                                     SSR outputs 2                                       input
                                                                              1       2                                E5AN-HAA2HBMD-500

1/4 DIN                                                                       1       2                    4 to 20-mA  E5AN-HSS2HBMD-500
96 96 78                                                                                               input
(W H D)                                       2

                                    Basic                                     2       2  4 to 20-mA        4 to 20-mA  E5AN-HAA2HHBFMD-500   E5CN-H (48 x 48 mm)
                      24 VAC/                                                            output            input
                      VDC
                                                                              2       2  4 to 20-mA        4 to 20-mA  E5AN-HSS2HHBFMD-500
                                                  3                                      output            input

                                                                                      2  4 to 20-mA        4 to 20-mA  E5AN-HAA3BFMD-500
                                                                                         output            input

                                                                                      2  4 to 20-mA        4 to 20-mA  E5AN-HSS3BFMD-500
                                                                                         output            input

                                                     Relay outputs 2                2                    4 to 20-mA  E5AN-HPRR2BMD-500
                                                     Relay outputs 2                                     input
                               Valve 2
                                                                                         4 to 20-mA        4 to 20-mA
                                                                                      2  output            input       E5AN-HPRR2BFMD-500

                      100 to                         Control Output Unit 2  1       2                    4 to 20-mA  E5AN-HAA2HBM-W-500
                                                     Control Output Unit 2                               input
                                                     Control Output Unit 2                                                                 E5AN-H (96 x 96 mm)
              Silver  240 VAC  Basic 2                                        2       2  4 to 20-mA        4 to 20-mA  E5AN-HAA2HHBFM-W-500     E5EN-H (48 x 96 mm)
                                                                                         output            input

                      24 VAC/                                                 1       2                    4 to 20-mA  E5AN-HAA2HBMD-W-500
                      VDC                                                                                  input

                                                                                                                                             Operation

                                                                                                                                             Safety Precautions

                                                                                                                                             45
                        E5AN-H/E5EN-H

E5CN                    E5EN-H
   E5CN-U (48 x 48 mm)
                                      Case    Power    Control   Auxil-                                 Heater          Optional Functions
                                      color   supply   method      iary
                        Size                  voltage            output        Control output 1/2       burn-   Event   Transfer  RSP                         Model
                                                                                                         out    inputs   output
                                                                                                                                               E5EN-HAA2HBM-500
                                                                               Control Output Unit 2  1       2                 4 to 20-mA   E5EN-HSS2HBM-500
                                                                                                                                  input        E5EN-HAA2HHBFM-500
                                                                                                                                               E5EN-HSS2HHBFM-500
                                                                               SSR outputs 2          1       2                 4 to 20-mA   E5EN-HAA3BFM-500
                                                                               Control Output Unit 2                            input        E5EN-HSS3BFM-500
                                                                            2  SSR outputs 2                                                 E5EN-HPRR2BM-500
                                                                               Control Output Unit 2  2       2       4 to 20-mA 4 to 20-mA  E5EN-HPRR2BFM-500
                                                             Basic             SSR outputs 2                                                 E5EN-HAA2HBMD-500
                                              100 to                                                                    output    input        E5EN-HSS2HBMD-500
                                              240 VAC                                                                                          E5EN-HAA2HHBFMD-500
                                                                                                        2       2       4 to 20-mA 4 to 20-mA  E5EN-HSS2HHBFMD-500
                                                                            3                                                                  E5EN-HAA3BFMD-500
E5AN (96 x 96 mm)                                                                                                       output    input        E5EN-HSS3BFMD-500
   E5EN (48 x 96 mm)                                                                                                                           E5EN-HPRR2BMD-500
                                                                                                                2       4 to 20-mA 4 to 20-mA  E5EN-HPRR2BFMD-500
                                                                                                                                               E5EN-HAA2HBM-W-500
                                                                                                                        output    input        E5EN-HAA2HHBFM-W-500
                                                                                                                                               E5EN-HAA2HBMD-W-500
                                                                                                                2       4 to 20-mA 4 to 20-mA

                                                                                                                        output