                                                                                  XR16L2750

                                                          2.25V TO 5.5V DUART WITH 64-BYTE FIFO

SEPTEMBER 2002                                                                                                  REV. 1.0.0

GENERAL DESCRIPTION                                       FEATURES

The XR16L27501 (2750) is a low voltage dual                2.25 to 5.5 Volt Operation
universal asynchronous receiver and transmitter            5 Volt Tolerant Inputs
(UART) with 5 Volt tolerant inputs. The device             Pin-to-pin compatible to Exar's ST16C2550 and
operates from 2.25 to 5.5 Volt supply range and is
pin-to-pin compatible to Exar's ST16C2550 and               TI's TL16C752B on the 48-TQFP package
XR16C2850 except the 48-TQFP package. The 2750
register set is compatible to the ST16C2550 and the       Pin alike XR16C2850 48-TQFP package but
XR16C2850 enhanced features. It supports the
Exar's enhanced features of 64 bytes of TX and RX           without CLK8/16, CLKSEL and HDCNTL inputs
FIFOs, programmable FIFO trigger level and FIFO
level counters, automatic hardware (RTS/CTS) and          Two independent UART channels
software flow control, automatic RS-485 half duplex
direction control output and a complete modem                  s Reg set compatible to 16C2550 and 16C2850
interface. Onboard registers provide the user with             s Up to 6.25 Mbps at 5 Volt, 4 Mbps at 3.3 Volt,
operational status and data error flags. An internal
loopback capability allows system diagnostics.                    and 3 Mbps at 2.5 Volt with 8X sampling rate
Independent programmable baud rate generators are              s Transmit and Receive FIFOs of 64 bytes
provided in each channel to select data rates up to            s Programmable TX and RX FIFO Trigger Levels
6.25 Mbps at 5 Volt and 8X sampling clock. The 2750            s Transmit and Receive FIFO Level Counters
is available in 48-pin TQFP and 44-pin PLCC                    s Automatic Hardware (RTS/CTS) Flow Control
packages.                                                      s Selectable Auto RTS Flow Control Hysteresis
                                                               s Automatic Software (Xon/Xoff) Flow Control
NOTE: 1 Covered by U.S. Patent #5,649,122 and #5,832,205       s Automatic RS-485 Half-duplex Direction

APPLICATIONS                                                      Control Output via RTS#
                                                               s Wireless Infrared (IrDA 1.0) Encoder/Decoder
Portable Appliances                                          s Automatic sleep mode
Telecommunication Network Routers                            s Full modem interface
Ethernet Network Routers
Cellular Data Devices                                    Device Identification and Revision
Factory Automation and Process Controls                  Crystal oscillator or external clock input
                                                          Industrial and commercial temperature ranges
         FIGURE 1. XR16L2750 BLOCK DIAGRAM                48-TQFP and 44-PLCC packages

      A2:A0                                               * 5 Volt Tolerant Inputs  2.25 to 5.5 Volt VCC
      D7:D0                                                                         GND
                                                          UART Channel A
       IOR#                                                                         TXA, RXA, DTRA#,
       IOW#                                               UART  64 Byte TX FIFO     DSRA#, RTSA#,
       CSA#                                               Regs                      DTSA#, CDA#, RIA#,
       CSB#                                                     TX & RX       IR    OP2A#
        INTA                                              BRG
        INTB    8-bit Data                                               ENDEC      TXB, RXB, DTRB#,
TXRDYA#             Bus                                                             DSRB#, RTSB#,
TXRDYB#                                                                             CTSB#, CDB#, RIB#,
RXRDYA#         Interface                                                           OP2B#
RXRDYB#
                                                            UART Channel B          XTAL1
      Reset                                               (same as Channel A)       XTAL2

                                                          Crystal Osc/Buffer                           2750BLK

Exar Corporation 48720 Kato Road, Fremont CA, 94538 (510) 668-7000 FAX (510) 668-7017 www.exar.com
                                                                                      XR16L2750
                                            2.25V TO 5.5V DUART WITH 64-BYTE FIFO
FIGURE 2. PIN OUT ASSIGNMENT
                                                                                                        REV. 1.0.0

                               48 D4
                                      47 D3
                                             46 D2
                                                    45 D1
                                                           44 D0
                                                                  43 TXRDYA#
                                                                         42 VCC
                                                                                41 RIA#
                                                                                       40 CDA#
                                                                                              39 DSRA#
                                                                                                     38 CTSA#
                                                                                                            37 NC

        D5 1                   XR16L2750                                                                           36 RESET
        D6 2                   48-pin TQFP                                                                         35 DTRB#
        D7 3                                                                                                       34 DTRA#
     RXB 4                                                                                                         33 RTSA#
     RXA 5                                                                                                         32 OP2A#
TXRDYB# 6                                                                                                          31 RXRDYA#
      TXA 7                                                                                                        30 INTA
      TXB 8                                                                                                        29 INTB
    OP2B# 9                                                                                                        28 A0
      CSA# 10                                                                                                      27 A1
      CSB# 11                                                                                                      26 A2
                                                                                                                   25 NC
         NC 12

                               XTAL1 13
                                      XTAL2 14
                                             IOW# 15
                                                    CDB# 16

                                                           GND 17
                                                                  RXRDYB# 18

                                                                         IOR# 19
                                                                                DSRB# 20

                                                                                       RIB# 21
                                                                                              RTSB# 22
                                                                                                     CTSB# 23

                                                                                                            NC 24

                               6 D4
                                      5 D3
                                             4 D2
                                                    3 D1
                                                            2 D0
                                                                   1 TXRDYA#
                                                                          44 VCC
                                                                                  43 RIA#
                                                                                         42 CDA#
                                                                                                41 DSRA#
                                                                                                        40 CTSA#

          D5 7                 XR16L2750                                                                           39 RESET
          D6 8                 44-pin PLCC                                                                         38 DTRB#
          D7 9                                                                                                     37 DTRA#
        RXB 10                                                                                                     36 RTSA#
        RXA 11                                                                                                     35 OP2A#
TXRDYB# 12                                                                                                         34 RXRDYA#
        TXA 13                                                                                                     33 INTA
        TXB 14                                                                                                     32 INTB
    OP2B# 15                                                                                                       31 A0
      CSA# 16                                                                                                      30 A1
      CSB# 17                                                                                                      29 A2

                               XTAL1 18
                                      XTAL2 19

                                             IOW# 20
                                                    CDB# 21
                                                            GND 22
                                                                   RXRDYB# 23
                                                                          IOR# 24
                                                                                  DSRB# 25
                                                                                         RIB# 26
                                                                                                RTSB# 27
                                                                                                        CTSB# 28

ORDERING INFORMATION           PACKAGE                                                                             OPERATING TEMPERATURE RANGE
                               44-PLCC                                                                                          0C to +70C
                 PART NUMBER   44-PLCC                                                                                        -40C to +85C
                 XR16L2750CJ   48-TQFP                                                                                          0C to +70C
                  XR16L2750IJ  48-TQFP                                                                                        -40C to +85C
                XR16L2750CM
                 XR16L2750IM       2
XR16L2750                                                   
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

PIN DESCRIPTIONS

Pin Description

NAME     44-PLCC     48-TQFP          TYPE     DESCRIPTION
           PIN #       PIN #

DATA BUS INTERFACE                     I Address data lines [2:0]. These 3 address lines select one of the inter-
   A2:A0 29, 30, 31 26, 27, 28                 nal registers in UART channel A/B during a data bus transaction.

D7:D0    9, 8, 7, 6, 5, 3, 2, 1, 48,  I/O Data bus lines [7:0] (bidirectional).
IOR#        4, 3, 2 47, 46, 45,
                                 44    I Input/Output Read Strobe (active low). The falling edge instigates an
                                               internal read cycle and retrieves the data byte from an internal register
                 24  19                        pointed to by the address lines [A2:A0]. The data byte is placed on the
                                               data bus to allow the host processor to read it on the rising edge.
IOW#             20  15
                                       I Input/Output Write Strobe (active low). The falling edge instigates an
CSA#             16  10                        internal write cycle and the rising edge transfers the data byte on the
                                               data bus to an internal register pointed by the address lines.
CSB#             17  11
                                       I UART channel A select (active low) to enable UART channel A in the
INTA             33  30                        device for data bus operation.

INTB             32  29                I UART channel B select (active low) to enable UART channel B in the
                                               device for data bus operation.
TXRDYA#          1   43
                                      O UART channel A Interrupt output. The output state is defined by the
RXRDYA#          34  31                        user through the software setting of MCR[3]. INTA is set to the active
                                               mode and OP2A# output to a logic 0 when MCR[3] is set to a logic 1.
TXRDYB#          12  6                         INTA is set to the three state mode and OP2A# to a logic 1 when
                                               MCR[3] is set to a logic 0 (default). See MCR[3].
RXRDYB#          23  18
                                      O UART channel B Interrupt output. The output state is defined by the
                                               user through the software setting of MCR[3]. INTB is set to the active
                                               mode and OP2B# output to a logic 0 when MCR[3] is set to a logic 1.
                                               INTB is set to the three state mode and OP2B# to a logic 1 when
                                               MCR[3] is set to a logic 0 (default). See MCR[3].

                                      O UART channel A Transmitter Ready (active low). The output
                                             provides the TX FIFO/THR status for transmit channel A. See
                                             Table 2. If it is not used, leave it unconnected.

                                      O UART channel A Receiver Ready (active low). This output provides the
                                              RX FIFO/RHR status for receive channel A. See Table 2. If it is not
                                               used, leave it unconnected.

                                      O UART channel B Transmitter Ready (active low). The output provides
                                              the TX FIFO/THR status for transmit channel B. See Table 2. If it is not
                                               used, leave it unconnected.

                                      O UART channel B Receiver Ready (active low). This output provides the
                                              RX FIFO/RHR status for receive channel B. See Table 2. If it is not
                                               used, leave it unconnected.

                                            3
                                                                                  XR16L2750
                                        2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                    REV. 1.0.0

Pin Description

NAME   44-PLCC       48-TQFP   TYPE     DESCRIPTION
         PIN #         PIN #

MODEM OR SERIAL I/O INTERFACE

TXA              13  7         O UART channel A Transmit Data or infrared encoder data. Standard
                                       transmit and receive interface is enabled when MCR[6] = 0. In this
RXA              11  5                 mode, the TX signal will be a logic 1 during reset or idle (no data). Infra-
                                       red IrDA transmit and receive interface is enabled when MCR[6] = 1. In
RTSA#            36  33                the Infrared mode, the inactive state (no data) for the Infrared encoder/
                                       decoder interface is a logic 0. If it is not used, leave it unconnected.
CTSA#            40  38
                               I UART channel A Receive Data or infrared receive data. Normal receive
DTRA#            37  34                data input must idle at logic 1 condition. The infrared receiver pulses
                                       typically idles at logic 0 but can be inverted by software control prior
DSRA#            41  39                going in to the decoder, see MCR[6] and FCTR[2]. If this pin is not
                                       used, tie it to VCC or pull it high via a 100k ohm resistor.
CDA#             42  40
                               O UART channel A Request-to-Send (active low) or general purpose out-
RIA#             43  41                put. This output must be asserted prior to using auto RTS flow control,
                                       see EFR[6], MCR[1], FCTR[1:0], EMSR[5:4] and IER[6]. For auto
OP2A#            35  32                RS485 half-duplex direction control, see FCTR[3] and EMSR[3].

TXB              14  8         I UART channel A Clear-to-Send (active low) or general purpose input.
                                       It can be used for auto CTS flow control, see EFR[7], and IER[7]. This
                                       input should be connected to VCC when not used.

                               O UART channel A Data-Terminal-Ready (active low) or general purpose
                                       output. If it is not used, leave it unconnected.

                               I UART channel A Data-Set-Ready (active low) or general purpose input.
                                       This input should be connected to VCC when not used. This input has
                                       no effect on the UART.

                               I UART channel A Carrier-Detect (active low) or general purpose input.
                                       This input should be connected to VCC when not used. This input has
                                       no effect on the UART.

                               I UART channel A Ring-Indicator (active low) or general purpose input.
                                       This input should be connected to VCC when not used. This input has
                                       no effect on the UART.

                               O Output Port 2 Channel A - The output state is defined by the user and
                                       through the software setting of MCR[3]. INTA is set to the active mode
                                       and OP2A# output to a logic 0 when MCR[3] is set to a logic 1. INTA is
                                       set to the three state mode and OP2A# to a logic 1 when MCR[3] is set
                                       to a logic 0. See MCR[3]. This output should not be used as a general
                                       output else it will disturb the INTA output functionality.

                               O UART channel B Transmit Data or infrared encoder data. Standard
                                       transmit and receive interface is enabled when MCR[6] = 0. In this
                                       mode, the TX signal will be a logic 1 during reset or idle (no data). Infra-
                                       red IrDA transmit and receive interface is enabled when MCR[6] = 1. In
                                       the Infrared mode, the inactive state (no data) for the Infrared encoder/
                                       decoder interface is a logic 0. If it is not used, leave it unconnected.

                                     4
XR16L2750                                                                           
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

Pin Description

NAME  44-PLCC       48-TQFP      TYPE                                 DESCRIPTION
RXB     PIN #         PIN #
           10             4       I UART channel B Receive Data or infrared receive data. Normal receive
RTSB#                                     data input must idle at logic 1 condition. The infrared receiver pulses
           27            22               typically idles at logic 0 but can be inverted by software control prior
CTSB#                                     going in to the decoder, see MCR[6] and FCTR[2]. If this pin is not
DTRB#      28            23               used, tie it to VCC or pull it high via a 100k ohm resistor.
DSRB#      38            35
CDB#      25            20       O UART channel B Request-to-Send (active low) or general purpose out-
           21            16               put. This port must be asserted prior to using auto RTS flow control,
RIB#      26            21               see EFR[6], MCR[1], FCTR[1:0], EMSR[5:4] and IER[6]. For auto
OP2B#      15             9               RS485 half-duplex direction control, see FCTR[3] and EMSR[3].

                                  I UART channel B Clear-to-Send (active low) or general purpose input.
                                          It can be used for auto CTS flow control, see EFR[7], and IER[7]. This
                                          input should be connected to VCC when not used.

                                  O UART channel B Data-Terminal-Ready (active low) or general purpose
                                          output. If it is not used, leave it unconnected.

                                  I UART channel B Data-Set-Ready (active low) or general purpose input.
                                          This input should be connected to VCC when not used. This input has
                                          no effect on the UART.

                                  I UART channel B Carrier-Detect (active low) or general purpose input.
                                          This input should be connected to VCC when not used. This input has
                                          no effect on the UART.

                                  I UART channel B Ring-Indicator (active low) or general purpose input.
                                          This input should be connected to VCC when not used. This input has
                                          no effect on the UART.

                                  O Output Port 2 Channel B - The output state is defined by the user and
                                          through the software setting of MCR[3]. INTB is set to the active mode
                                          and OP2B# output to a logic 0 when MCR[3] is set to a logic 1. INTB is
                                          set to the three state mode and OP2B# to a logic 1 when MCR[3] is set
                                          to a logic 0. See MCR[3]. This output should not be used as a general
                                          output else it will disturb the INTB output functionality.

ANCILLARY SIGNALS

XTAL1            18       13        I Crystal or external clock input. Caution: this input is not 5V tolerant.
                          14
XTAL2            19       36       O Crystal or buffered clock output.

RESET            39       42        I Reset (active high) - A longer than 40 ns logic 1 pulse on this pin will
                                           reset the internal registers and all outputs. The UART transmitter output
VCC     44                17               will be held at logic 1, the receiver input will be ignored and outputs are
                     12, 24, 25,           reset during reset period (see External Reset Conditions).
GND     22
N.C.   none               37      Pwr 2.25V to 5.5V power supply. All input pins, except XTAL1, are 5V toler-
                                           ant.

                                  Pwr Power supply common, ground.

                                           No Connection. These pins are open, but typically, should be con-
                                           nected to GND for good design practice.

Pin type: I=Input, O=Output, I/O= Input/output, OD=Output Open Drain.

                                        5
                                                 XR16L2750
       2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                   REV. 1.0.0

1.0 PRODUCT DESCRIPTION

The XR16L2750 (2750) integrates the functions of 2 enhanced 16C550 Universal Asynchronous Receiver and
Transmitter (UART). Each UART is independently controlled having its own set of device configuration
registers. The configuration registers set is 16550 UART compatible for control, status and data transfer.
Additionally, each UART channel has 64-bytes of transmit and receive FIFOs, automatic RTS/CTS hardware
flow control with hysteresis control, automatic Xon/Xoff and special character software flow control,
programmable transmit and receive FIFO trigger levels, FIFO level counters, infrared encoder and decoder
(IrDA ver 1.0), programmable baud rate generator with a prescaler of divide by 1 or 4, and data rate up to 6.25
Mbps with 8X sampling clock rate or 3.125 Mbps in the 16X rate. The XR16L2750 is a 2.25 to 5.5V device with
5 volt tolerant inputs. The 2750 is fabricated with an advanced CMOS process.

Enhanced Features

The 2750 DUART provides a solution that supports 64 bytes of transmit and receive FIFO memory, instead of
128 bytes provided in the XR16C2850 and 16 bytes in the ST16C2550, or one byte in the ST16C2450. The
2750 is designed to work with low supply voltage and high performance data communication systems, that
require fast data processing time. Increased performance is realized in the 2750 by the larger transmit and
receive FIFOs, FIFO trigger level control, FIFO level counters and automatic flow control mechanism. This
allows the external processor to handle more networking tasks within a given time. For example, the
ST16C2550 with a 16 byte FIFO, unloads 16 bytes of receive data in 1.53 ms (This example uses a character
length of 11 bits, including start/stop bits at 115.2 Kbps). This means the external CPU will have to service the
receive FIFO at 1.53 ms intervals. However with the 64 byte FIFO in the 2750, the data buffer will not require
unloading/loading for 6.1 ms. This increases the service interval giving the external CPU additional time for
other applications and reducing the overall UART interrupt servicing time. In addition, the programmable FIFO
level trigger interrupt and automatic hardware/software flow control is uniquely provided for maximum data
throughput performance especially when operating in a multi-channel system. The combination of the above
greatly reduces the CPU's bandwidth requirement, increases performance, and reduces power consumption.

The 2750 supports a half-duplex output direction control signaling pin, RTS# A/B, to enable and disable the
external RS-485 transceiver operation. It automatically switches the logic state of the output pin to the receive
state after the last stop-bit of the last character has been shifted out of the transmitter. After receiving, the logic
state of the output pin switches back to the transmit state when a data byte is loaded in the transmitter. The
auto RS-485 direction control pin is not activated after reset. To activate the direction control function, user has
to set FCTR Bit-3 to "1". This pin is normally high for receive state, low for transmit state.

Data Rate

The 2750 is capable of operation up to 3.125 Mbps at 5V with 16X internal sampling clock rate, and 6.25 Mbps
at 5V with 8X sampling clock rate. The device can operate with an external 24 MHz crystal on pins XTAL1 and
XTAL2, or external clock source of up to 50 MHz on XTAL1 pin. With a typical crystal of 14.7456 MHz and
through a software option, the user can set the prescaler bit for data rates of up to 1.84 Mbps.

The rich feature set of the 2750 is available through the internal registers. Automatic hardware/software flow
control, selectable transmit and receive FIFO trigger levels, selectable TX and RX baud rates, infrared encoder/
decoder interface, modem interface controls, and a sleep mode are all standard features.

Following a power on reset or an external reset, the 2750 is software compatible with previous generation of
UARTs, 16C450, 16C550 and 16C650A as well as the 16C850.

    6
XR16L2750                                                                     
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

2.0 FUNCTIONAL DESCRIPTIONS

2.1 CPU Interface

The CPU interface is 8 data bits wide with 3 address lines and control signals to execute data bus read and
write transactions. The 2750 data interface supports the Intel compatible types of CPUs and it is compatible to
the industry standard 16C550 UART. No clock (oscillator nor external clock) is required to operate a data bus
transaction. Each bus cycle is asynchronous using CS#, IOR# and IOW# signals. Both UART channels share
the same data bus for host operations. The data bus interconnections are shown in Figure 3.

FIGURE 3. XR16L2750 DATA BUS INTERCONNECTIONS

                 D0                               D0          UART        VCC  VCC
                 D1                               D1       Channel A                Serial Interface of
                 D2                               D2                      TXA        RS-232, RS-485
                 D3                               D3                      RXA
                 D4                               D4                  DTRA#         Serial Interface of
                 D5                               D5                  RTSA#          RS-232, RS-485
                 D6                               D6                  CTSA#
                 D7                               D7                  DSRA#                                2750int
                                                                       CDA#
                 A0                                A0                    RIA#
                 A1                                A1                 OP2A#
                 A2
                                                   A2                     TXB
             IOR#                                                         RXB
             IOW#                                 IOR#                DTRB#
                                                                      RTSB#
UART_CSA#                                        IOW#                CTSB#
UART_CSB#                                                            DSRB#
                                                  CSA#        UART      CDB#
   UART_INTA                                      CSB#     Channel B     RIB#
   UART_INTB                                                           OP2B#
                                                  INTA
      TXRDYA#                                     INTB
      RXRDYA#
      TXRDYB#                                     TXRDYA#
      RXRDYB#                                     RXRDYA#
                                                  TXRDYB#
UART_RESET                                        RXRDYB#

                                                  RESET               GND

2.2 5-Volt Tolerant Inputs

The 2750 can accept up to 5V inputs even when operating at 3.3V or 2.5V. But note that if the 2750 is operating
at 2.5V, its VOH may not be high enough to meet the requirements of the VIH of a CPU or a serial transceiver
that is operating at 5V. Caution: XTAL1 is not 5 volt tolerant.

2.3 Device Reset

The RESET input resets the internal registers and the serial interface outputs in both channels to their default
state (see Table 16). An active high pulse of longer than 40 ns duration will be required to activate the reset
function in the device.

2.4 Device Identification and Revision

The XR16L2750 provides a Device Identification code and a Device Revision code to distinguish the part from
other devices and revisions. To read the identification code from the part, it is required to set the baud rate
generator registers DLL and DLM both to 0x00. Now reading the content of the DLM will provide 0x0A for the
XR16L2750 and reading the content of DLL will provide the revision of the part; for example, a reading of 0x01
means revision A.

2.5 Channel A and B Selection

The UART provides the user with the capability to bi-directionally transfer information between an external CPU
and an external serial communication device. A logic 0 on chip select pins, CSA# or CSB#, allows the user to
select UART channel A or B to configure, send transmit data and/or unload receive data to/from the UART.

                                               7
                                                                                                              XR16L2750
                                                                    2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                                REV. 1.0.0

Selecting both UARTs can be useful during power up initialization to write to the same internal registers, but do
not attempt to read from both uarts simultaneously. Individual channel select functions are shown in Table 1.

                                      TABLE 1: CHANNEL A AND B SELECT

                                      CSA#  CSB#                FUNCTION
                                         1     1          UART de-selected
                                         0     1         Channel A selected
                                         1     0         Channel B selected
                                         0     0     Channel A and B selected

2.6 Channel A and B Internal Registers

Each UART channel in the 2750 has a set of enhanced registers for control, monitoring and data loading and
unloading. The configuration register set is compatible to those already available in the standard single 16C550
and dual ST16C2550. These registers function as data holding registers (THR/RHR), interrupt status and
control registers (ISR/IER), a FIFO control register (FCR), receive line status and control registers (LSR/LCR),
modem status and control registers (MSR/MCR), programmable data rate (clock) divisor registers (DLL/DLM),
and a user accessible Scratchpad Register (SPR).

Beyond the general 16C2550 features and capabilities, the 2750 offers enhanced feature registers (EMSR,
FLVL, EFR, Xon/Xoff 1, Xon/Xoff 2, FCTR, TRG, FC) that provide automatic RTS and CTS hardware flow
control, Xon/Xoff software flow control, automatic RS-485 half-duplex direction output enable/disable, FIFO
trigger level control, and FIFO level counters. All the register functions are discussed in full detail later in
"Section 3.0, UART INTERNAL REGISTERS" on page 19.

2.7 DMA Mode

The device does not support direct memory access. The DMA Mode (a legacy term) in this document doesn't
mean "direct memory access" but refers to data block transfer operation. The DMA mode affects the state of
the RXRDY# A/B and TXRDY# A/B output pins. The transmit and receive FIFO trigger levels provide additional
flexibility to the user for block mode operation. The LSR bits 5-6 provide an indication when the transmitter is
empty or has an empty location(s) for more data. The user can optionally operate the transmit and receive
FIFO in the DMA mode (FCR bit-3=1). When the transmit and receive FIFO are enabled and the DMA mode is
disabled (FCR bit-3 = 0), the 2750 is placed in single-character mode for data transmit or receive operation.
When DMA mode is enabled (FCR bit-3 = 1), the user takes advantage of block mode operation by loading or
unloading the FIFO in a block sequence determined by the programmed trigger level. In this mode, the 2750
sets the TXRDY# pin when the transmit FIFO becomes full, and sets the RXRDY# pin when the receive FIFO
becomes empty. The following table shows their behavior. Also see Figures 18 through 23.

      TABLE 2: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE

PINS    FCR BIT-0=0                                  FCR BIT-0=1 (FIFO ENABLED)
      (FIFO DISABLED)

RXRDY# A/B 0 = 1 byte.                            FCR Bit-3 = 0                            FCR Bit-3 = 1
                    1 = no data.            (DMA Mode Disabled)                      (DMA Mode Enabled)
                                      0 = at least 1 byte in FIFO
TXRDY# A/B 0 = THR empty.             1 = FIFO empty.               1 to 0 transition when FIFO reaches the trigger
                    1 = byte in THR.                                level, or time-out occurs.
                                      0 = FIFO empty.               0 to 1 transition when FIFO empties.
                                      1 = at least 1 byte in FIFO.
                                                                    0 = FIFO has at least 1 empty location.
                                                                    1 = FIFO is full.

                                                  8
XR16L2750                                                                                   
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

2.8 INTA and INTB Outputs

The INTA and INTB interrupt output changes according to the operating mode and enhanced features setup.
Table 3 and 4 summarize the operating behavior for the transmitter and receiver. Also see Figures 18
through 23.

            TABLE 3: INTA AND INTB PINS OPERATION FOR TRANSMITTER

INTA/B Pin  Auto RS485           FCR BIT-0 = 0                                    FCR BIT-0 = 1
INTA/B Pin      Mode           (FIFO DISABLED)                                  (FIFO ENABLED)
                  NO
                        0 = a byte in THR            0 = FIFO above trigger level
                 YES    1 = THR empty                1 = FIFO below trigger level or FIFO empty

                        0 = a byte in THR            0 = FIFO above trigger level
                        1 = transmitter empty        1 = FIFO below trigger level or transmitter empty

            TABLE 4: INTA AND INTB PIN OPERATION FOR RECEIVER

INTA/B Pin              FCR BIT-0 = 0                                        FCR BIT-0 = 1
                       (FIFO DISABLED)                                      (FIFO ENABLED)

            0 = no data                 0 = FIFO below trigger level
            1 = 1 byte                  1 = FIFO above trigger level

2.9 Crystal Oscillator or External Clock Input

The 2750 includes an on-chip oscillator (XTAL1 and XTAL2) to produce a clock for both UART sections in the
device. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a
system clock to the Baud Rate Generators (BRG) section found in each of the UART. XTAL1 is the input to the
oscillator or external clock buffer input with XTAL2 pin being the output. Please note that the input XTAL1 is not
5V tolerant and so the maximum at the pin should be VCC. For programming details, see "Programmable Baud
Rate Generator."

                        FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS

                                        XTAL1     XTAL2

                                                        R2      R1
                                                  500  - 1   0-120
                                                             (Optional)

                                                     Y1      1.8432 MHz
                                                                  to

                                                             24 MHz

                                           C1        C2
                                        22-47 pF
                                                  22-47 pF

                                                  9
                                                                                           XR16L2750
                                                 2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                             REV. 1.0.0

The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant,
fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100 ppm frequency
tolerance) connected externally between the XTAL1 and XTAL2 pins (see Figure 4). The programmable Baud
Rate Generator is capable of operating with a crystal oscillator frequency of up to 24 MHz. However, with an
external clock input on XTAL1 pin and a 2K ohms pull-up resistor on XTAL2 pin (as shown in Figure 5) it can
extend its operation up to 50 MHz (6.25 Mbps serial data rate) at 5V with an 8X sampling rate.

           FIGURE 5. EXTERNAL CLOCK CONNECTION FOR EXTENDED DATA RATE

                               External Clock    XTAL1
                                                 XTAL2
                      vcc

                      gnd

                                            VCC

                                         R1
                                         2K

For further reading on the oscillator circuit please see the Application Note DAN108 on the EXAR web site at
http://www.exar.com.

2.10 Programmable Baud Rate Generator

Each UART has its own Baud Rate Generator (BRG) with a prescaler. The prescaler is controlled by a software
bit in the MCR register. The MCR register bit-7 sets the prescaler to divide the input crystal or external clock by
1 or 4. The clock output of the prescaler goes to the BRG. The BRG further divides this clock by a
programmable divisor between 1 and (216 -1) to obtain a 16X sampling rate clock of the serial data rate. The
sampling rate clock is used by the transmitter for data bit shifting and receiver for data sampling. The BRG
divisor defaults to the maximum baud rate (DLL = 0x01 and DLM = 0x00) upon power up.

                 FIGURE 6. BAUD RATE GENERATOR AND PRESCALER

    XTAL1  C rystal    P re s ca le r                           DLL and DLM            16X
    XTAL2   Osc/      D ivide by 1                                  R egisters     Sam pling
           B u ffe r                                                            R ate C lock to
                       P re s ca le r            M C R Bit-7=0                   Transm itter
                      D ivide by 4                  (d e fa u lt)

                                                                Baud Rate
                                                                 G enerator

                                                                    L o g ic

                                                 M C R Bit-7=1

Programming the Baud Rate Generator Registers DLM and DLL provides the capability of selecting the
operating data rate. Table 5 shows the standard data rates available with a 14.7456 MHz crystal or external
clock at 16X sampling rate clock rate. A 16X sampling clock is typically used. However, user can select the 8X

                      10
XR16L2750                                                                        
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

sampling clock rate mode (EMSR bit-7=0) to double the operating data rate. When using a non-standard data
rate crystal or external clock, the divisor value can be calculated for DLL/DLM with the following equation.

divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 16), with 16XMode [EMSR bit-7] = 1
divisor (decimal) = (XTAL1 clock frequency / prescaler) / (serial data rate x 8), with 16XMode [EMSR bit-7] = 0

        TABLE 5: TYPICAL DATA RATES WITH A 14.7456 MHZ CRYSTAL OR EXTERNAL CLOCK

OUTPUT Data Rate OUTPUT Data Rate                                    DLM           DLL    DATA RATE
             MCR Bit-7=0 DIVISOR FOR 16x DIVISOR FOR 16x          PROGRAM      PROGRAM    ERROR (%)
MCR Bit-7=1                        Clock (Decimal) Clock (HEX)  VALUE (HEX)  VALUE (HEX)

             (DEFAULT)

100          400                   2304      900                09           00           0

600          2400                  384       180                01           80           0

1200         4800                  192       C0                 00           C0           0

2400         9600                  96        60                 00           60           0

4800         19.2k                 48        30                 00           30           0

9600         38.4k                 24        18                 00           18           0

19.2k        76.8k                 12        0C                 00           0C           0

38.4k        153.6k                6         06                 00           06           0

57.6k        230.4k                4         04                 00           04           0

115.2k       460.8k                2         02                 00           02           0

230.4k       921.6k                1         01                 00           01           0

2.11 Transmitter

The transmitter section comprises of an 8-bit Transmit Shift Register (TSR) and 64 bytes of FIFO which
includes a byte-wide Transmit Holding Register (THR). TSR shifts out every data bit with the 16X/8X internal
clock. A bit time is 16 (8) clock periods (see EMSR bit-7). The transmitter sends the start-bit followed by the
number of data bits, inserts the proper parity-bit if enabled, and adds the stop-bit(s). The status of the FIFO
and TSR are reported in the Line Status Register (LSR bit-5 and bit-6).

2.11.1 Transmit Holding Register (THR) - Write Only

The transmit holding register is an 8-bit register providing a data interface to the host processor. The host
writes transmit data byte to the THR to be converted into a serial data stream including start-bit, data bits,
parity-bit and stop-bit(s). The least-significant-bit (Bit-0) becomes first data bit to go out. The THR is the input
register to the transmit FIFO of 64 bytes when FIFO operation is enabled by FCR bit-0. Every time a write
operation is made to the THR, the FIFO data pointer is automatically bumped to the next sequential data
location.

2.11.2 Transmitter Operation in non-FIFO Mode

The host loads transmit data to THR one character at a time. The THR empty flag (LSR bit-5) is set when the
data byte is transferred to TSR. THR flag can generate a transmit empty interrupt (ISR bit-1) when it is enabled
by IER bit-1. The TSR flag (LSR bit-6) is set when TSR becomes completely empty.

                                         11
                                                                                                      XR16L2750
                                                            2.25V TO 5.5V DUART WITH 64-BYTE FIFO
FIGURE 7. TRANSMITTER OPERATION IN NON-FIFO MODE
                                                                                                                        REV. 1.0.0

Data                                    Transmit

Byte                                    Holding

                                        Register

                                        (THR)               THR Interrupt (ISR bit-1)

                                                            Enabled by IER bit-1

  16X or 8X      Transmit Shift Register (TSR)                        M                L
     Clock
                                                                      S                S
(EMSR Bit-7)

                                                                      B                B

                                                                                       TXNOFIFO1

2.11.3 Transmitter Operation in FIFO Mode
The host may fill the transmit FIFO with up to 64 bytes of transmit data. The THR empty flag (LSR bit-5) is set
whenever the FIFO is empty. The THR empty flag can generate a transmit empty interrupt (ISR bit-1) when the
amount of data in the FIFO falls below its programmed trigger level. The transmit empty interrupt is enabled by
IER bit-1. The TSR flag (LSR bit-6) is set when TSR/FIFO becomes empty.

FIGURE 8. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE

                              Transmit            Transmit            THR Interrupt (ISR bit-1) falls
                             Data Byte              FIFO              below the programmed Trigger
                                                                      Level and then when becomes
Auto CTS Flow Control (CTS# pin)                                      empty. FIFO is Enabled by FCR
Flow Control Characters                                              bit-0=1
(Xoff1/2 and Xon1/2 Reg.
Auto Software Flow Control

16X or 8X Clock                         Transmit Data Shift Register
  (EMSR bit-7)                                          (TSR)

                                                                                                  TXFIFO1

2.12 Receiver

The receiver section contains an 8-bit Receive Shift Register (RSR) and 64 bytes of FIFO which includes a
byte-wide Receive Holding Register (RHR). The RSR uses the 16X/8X clock (EMSR bit-7) for timing. It verifies
and validates every bit on the incoming character in the middle of each data bit. On the falling edge of a start or
false start bit, an internal receiver counter starts counting at the 16X/8X clock rate. After 8 clocks (or 4 if 8X) the
start bit period should be at the center of the start bit. At this time the start bit is sampled and if it is still a logic
0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character.
The rest of the data bits and stop bits are sampled and validated in this same manner to prevent false framing.
If there were any error(s), they are reported in the LSR register bits 2-4. Upon unloading the receive data byte
from RHR, the receive FIFO pointer is bumped and the error tags are immediately updated to reflect the status
of the data byte in RHR register. RHR can generate a receive data ready interrupt upon receiving a character
or delay until it reaches the FIFO trigger level. Furthermore, data delivery to the host is guaranteed by a receive

                                                  12
XR16L2750                                                                                                   
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

data ready time-out interrupt when data is not received for 4 word lengths as defined by LCR[1,0] plus 12 bits
time. This is equivalent to 3.7-4.6 character times. The RHR interrupt is enabled by IER bit-0.

2.12.1 Receive Holding Register (RHR) - Read-Only

The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift Register.
It provides the receive data interface to the host processor. The RHR register is part of the receive FIFO of 64
bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When the FIFO is
enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the RHR is read,
the next character byte is loaded into the RHR and the errors associated with the current data byte are
immediately updated in the LSR bits 2-4.

FIGURE 9. RECEIVER OPERATION IN NON-FIFO MODE

16X or 8X Clock                          Receive Data Shift                Data Bit
  (EM SR bit-7)                            Register (RSR)                 Validation

                                                                                                   Receive Data Characters

R e ce ive                              Error     Receive Data                  RHR Interrupt (ISR bit-2)
Data Byte                              Tags in   Holding Register
and Errors                             LSR bits                                                                                   R X F IF O 1
                                                         (R H R )
                                           4:2

FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE

   16X or 8X Clock                     Receive Data Shift   Data Bit                  Receive Data Characters
      (EMSR bit-7)                       Register (RSR)    Validation

    64 bytes by 11-bit                           Receive   Example
               wide                            Data FIFO
               FIFO                                        -:RX FIFO trigger level selected at 16
                                                 Receive
Receive Data                                        Data                  bytes
Byte and Errors
                                                           Data falls to   (See Note Below)
                                                                   8
                                                                          RTS# re-asserts when data falls below the flow

                                                                          control trigger level to restart remote transmitter.

                        Error Tags                                        Enable by EFR bit-6=1, MCR bit-1.
                           (64-sets)
                                                               FIFO       RHR Interrupt (ISR bit-2) programmed for
                                                           Trigger=16     desired FIFO trigger level.
                                                                          FIFO is Enabled by FCR bit-0=1

                                                           Data fills to  RTS# de-asserts when data fills above the flow
                                                                  24      control trigger level to suspend remote transmitter.
                                                                          Enable by EFR bit-6=1, MCR bit-1.
                        Error Tags in
                           LSR bits 4:2

                                                                                                                    RXFIFO1

NOTE: Table-B selected as Trigger Table for Figure 10 (Table 10).

                                                           13
                                                  XR16L2750
        2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                    REV. 1.0.0

2.13 Auto RTS (Hardware) Flow Control

Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control features
is enabled to fit specific application requirement (see Figure 11):
- Enable auto RTS flow control using EFR bit-6.
- The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
- Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.

2.14 Auto RTS Hysteresis

The 2750 has a new feature that provides flow control trigger hysteresis while maintaining compatibility with the
XR16C850, ST16C650A and ST16C550 family of UARTs. With the Auto RTS function enabled, an interrupt is
generated when the receive FIFO reaches the programmed RX trigger level. The RTS# pin will not be forced to
a logic 1 (RTS off), until the receive FIFO reaches the upper limit of the hysteresis level. The RTS# pin will
return to a logic 0 after the RX FIFO is unloaded to the lower limit of the hysteresis level. Under the above
described conditions, the 2750 will continue to accept data until the receive FIFO gets full. The Auto RTS
function is initiated when the RTS# output pin is asserted to a logic 0 (RTS On). Table 13 shows the complete
details for the Auto RTS# Hysteresis levels. Please note that this table is for programmable trigger levels only
(Table D). The hysteresis values for Tables A-C are the next higher and next lower trigger levels in the
corresponding table.

2.15 Auto CTS Flow Control

Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 11):
- Enable auto CTS flow control using EFR bit-7.
- Enable CTS interrupt through IER bit-7 (after setting EFR bit-4). The UART issues an interrupt when the
CTS# pin is de-asserted (logic 1): ISR bit-5 will be set to 1, and UART will suspend transmission as soon as the
stop bit of the character in process is shifted out. Transmission is resumed after the CTS# input is re-asserted
(logic 0), indicating more data may be sent.

    14
XR16L2750                                                                                       
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

FIGURE 11. AUTO RTS AND CTS FLOW CONTROL OPERATION

   Local UART                   RXA                                             Remote UART
      UARTA                                                                         UARTB

Receiver FIFO                                                TXB
Trigger Reached                                                                    Transmitter

  Auto RTS                      RTSA#                         CTSB#             Auto CTS
Trigger Level                   TXA                            RXB                Monitor

Transmitter                                                                  Receiver FIFO
                                                                             Trigger Reached

        Auto CTS                CTSA#                         RTSB#            Auto RTS
         Monitor                                                             Trigger Level

RTSA#            Assert RTS# to Begin                   OFF         10 ON
CTSB#                  Transmission        7
                                                                         11  ON
  TXB             1                                 8 OFF
                                ON

                      2
                                   ON

                        3

            Data Starts                    6 Suspend          Restart
                             4                                9

RXA FIFO

            Receive    RX FIFO          5  RTS High           RTS Low                  RX FIFO
                     Trigger Level         Threshold          Threshold      12 Trigger Level
    INTA    Data
(RXA FIFO

Interrupt)

                                                                                                RTSCTS1

The local UART (UARTA) starts data transfer by asserting RTSA# (1). RTSA# is normally connected to CTSB# (2) of

remote UART (UARTB). CTSB# allows its transmitter to send data (3). TXB data arrives and fills UARTA receive FIFO
(4). When RXA data fills up to its receive FIFO trigger level, UARTA activates its RXA data ready interrupt (5) and con-
tinues to receive and put data into its FIFO. If interrupt service latency is long and data is not being unloaded, UARTA
monitors its receive data fill level to match the upper threshold of RTS delay and de-assert RTSA# (6). CTSB# follows
(7) and request UARTB transmitter to suspend data transfer. UARTB stops or finishes sending the data bits in its trans-
mit shift register (8). When receive FIFO data in UARTA is unloaded to match the lower threshold of RTS delay (9),
UARTA re-asserts RTSA# (10), CTSB# recognizes the change (11) and restarts its transmitter and data flow again until
next receive FIFO trigger (12). This same event applies to the reverse direction when UARTA sends data to UARTB
with RTSB# and CTSA# controlling the data flow.

                                           15
                                                                                   XR16L2750
                                         2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                     REV. 1.0.0

2.16 Auto Xon/Xoff (Software) Flow Control

When software flow control is enabled (See Table 15), the 2750 compares one or two sequential receive data
characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the
programmed values, the 2750 will halt transmission (TX) as soon as the current character has completed
transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output
pin will be activated. Following a suspension due to a match of the Xoff character, the 2750 will monitor the
receive data stream for a match to the Xon-1,2 character. If a match is found, the 2750 will resume operation
and clear the flags (ISR bit-4).

Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user
can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/
Xoff characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are
selected, the 2750 compares two consecutive receive characters with two software flow control 8-bit values
(Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control
mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO.

In the event that the receive buffer is overfilling and flow control needs to be executed, the 2750 automatically
sends an Xoff message (when enabled) via the serial TX output to the remote modem. The 2750 sends the
Xoff-1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate)
after the receive FIFO crosses the programmed trigger level (for all trigger tables A-D). To clear this condition,
the 2750 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger
level below the programmed trigger level (for Trigger Tables A, B, and C) or when receive FIFO is less than the
trigger level minus the hysteresis value (for Trigger Table D). This hysteresis value is the same as the Auto RTS
Hysteresis value in Table 14. Table 6 below explains this when Trigger Table-B (See Table 10) is selected.

    TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL

RX TRIGGER LEVEL INT PIN ACTIVATION  XOFF CHARACTER(S) SENT    XON CHARACTER(S) SENT
                                      (CHARACTERS IN RX FIFO)  (CHARACTERS IN RX FIFO)
8   8
                                                    8*                        0
16  16                                              16*                       8
                                                    24*                       16
24  24                                              28*                       24

28  28

* After the trigger level is reached, an xoff character is sent after a short span of time (= time required to send 2
characters); for example, after 2.083ms has elapsed for 9600 baud and 10-bit word length setting.

2.17 Special Character Detect

A special character detect feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced
Feature Register (EFR). When this character (Xoff2) is detected, it will be placed in the FIFO along with normal
incoming RX data.

The 2750 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will
be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Although the Internal
Register Table shows Xon, Xoff Registers with eight bits of character information, the actual number of bits is
dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of
character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also
determines the number of bits that will be used for the special character comparison. Bit-0 in the Xon, Xoff
Registers corresponds with the LSB bit for the receive character.

2.18 Auto RS485 Half-duplex Control

The auto RS485 half-duplex direction control changes the behavior of the transmitter when enabled by FCTR
bit-3. By default, it de-asserts RTS# (logic 1) output following the last stop bit of the last character that has been
transmitted. This helps in turning around the transceiver to receive the remote station's response. When the
host is ready to transmit next polling data packet again, it only has to load data bytes to the transmit FIFO. The
transmitter automatically re-asserts RTS# (logic 0) output prior to sending the data. The RS485 half-duplex
direction control output can be inverted by enabling EMSR bit-3.

                                     16
XR16L2750                                                                                                
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

2.19 Infrared Mode

The 2750 UART includes the infrared encoder and decoder compatible to the IrDA (Infrared Data Association)
version 1.0. The IrDA 1.0 standard that stipulates the infrared encoder sends out a 3/16 of a bit wide HIGH-
pulse for each "0" bit in the transmit data stream. This signal encoding reduces the on-time of the infrared LED,
hence reduces the power consumption. See Figure 12 below.

The infrared encoder and decoder are enabled by setting MCR register bit-6 to a `1'. When the infrared feature
is enabled, the transmit data output, TX, idles at logic zero level. Likewise, the RX input assumes an idle level
of logic zero from a reset and power up, see Figure 12.

Typically, the wireless infrared decoder receives the input pulse from the infrared sensing diode on the RX pin.
Each time it senses a light pulse, it returns a logic 1 to the data bit stream. However, this is not true with some
infrared modules on the market which indicate a logic 0 by a light pulse. So the 2750 has a provision to invert
the input polarity to accommodate this. In this case user can enable FCTR bit-2 to invert the input signal.

FIGURE 12. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING

                                         C h a ra cte r
                                           Data Bits
TX Data 0 1 0 1 0 0 1 1 0 1
             Start
                                                                             Stop

  Transm it  Bit Tim e                 3/16 Bit Tim e  1/2 Bit Tim e
  IR Pulse
  (TX Pin)                                                      IrEncoder-1

Receive      Bit Time
IR Pulse         1/16 Clock Delay
(RX pin)
             0 1 0 1 0 0 11 0 1
RX Data                             Data Bits
                                    Character

                                                                                             IRdecoder-1
             Start
                                                                       Stop

2.20 Sleep Mode with Auto Wake-Up

The 2750 supports low voltage system designs, hence, a sleep mode is included to reduce its power
consumption when the chip is not actively used. With EFR bit-4 and IER bit-4 of both channels enabled (set to
a logic 1), the 2750 DUART enters sleep mode when no interrupt is pending for both channels. The 2750 stops
its crystal oscillator to further conserve power in the sleep mode. User can check the XTAL2 pin for no clock
output as an indication that the device has entered the sleep mode. The 2750 resumes normal operation by
any of the following: a receive data start bit transition (logic 1 to 0), a change of logic state on any of the modem
or general purpose input pins: CTS#, DSR#, CD#, RI# or a transmit data byte is loaded to the THR/FIFO by the
user. If the 2750 is awakened by one of the above conditions, it will return to the sleep mode automatically after
all interrupting condition have been serviced and cleared. If the 2750 is awakened by the modem inputs, a read
to the MSR is required to reset the modem inputs. In any case, the sleep mode will not be entered while an

                                       17
                                                                                                                                XR16L2750
                                                                                      2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                                                  REV. 1.0.0

interrupt is pending from channel A or B. The 2750 will stay in the sleep mode of operation until it is disabled by
setting IER bit-4 to a logic 0.

A word of caution: owing to the starting up delay of the crystal oscillator after waking up from sleep mode, the
first few receive characters may be lost. Also, make sure the RX A/B inputs are idling at logic 1 or "marking"
condition during sleep mode to avoid receiving a "break" condition upon the restart. This may occur when the
external interface transceivers (RS-232, RS-485 or another type) are also put to sleep mode and cannot
maintain the "marking" condition. To avoid this, the system design engineer can use a 47k ohm pull-up resistor
on the RXA and RXB pins.

2.21 Internal Loopback

The 2750 UART provides an internal loopback capability for system diagnostic purposes. The internal
loopback mode is enabled by setting MCR register bit-4 to logic 1. All regular UART functions operate normally.
Figure 13 shows how the modem port signals are re-configured. Transmit data from the transmit shift register
output is internally routed to the receive shift register input allowing the system to receive the same data that it
was sending. The TX pin is held at logic 1 or mark condition while RTS# and DTR# are de-asserted, and
CTS#, DSR# CD# and RI# inputs are ignored. Caution: the RX input must be held to a logic 1 during loopback
test else upon exiting the loopback test the UART may detect and report a false "break" signal. Also, Auto RTS/
CTS is not supported during internal loopback.

FIGURE 13. INTERNAL LOOP BACK IN CHANNEL A AND B

                                                                               VCC

    Transmit Shift Register                                                           TXA/TXB
           (THR/FIFO)
                                                                                      RXA/RXB
                                                                     MCR bit-4=1      RTSA#/RTSB#
                                                                                      CTSA#/CTSB#
Internal Data Bus Lines and Control SignalsReceive Shift Register                     DTRA#/DTRB#
                              Modem / General Purpose Control Logic(RHR/FIFO)         DSRA#/DSRB#
                                                                                      RIA#/RIB#
                                                                               VCC    OP2A#/OP2B#
                                                                                      CDA#/CDB#
                                                                     RTS#

                                                                     CTS#
                                                                                 VCC

                                                                     DTR#

                                                                     DSR#      OP1#
                                                                     RI#       VCC

                                                                     OP2#

                                                                     CD#

                                                                           18
XR16L2750                                                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

3.0 UART INTERNAL REGISTERS

Each of the UART channel in the 2750 has its own set of configuration registers selected by address lines A0,
A1 and A2 with CSA# or CSB# selecting the channel. The complete register set is shown on Table 7 and
Table 8.

      TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS

A2,A1,A0 ADDRESSES  REGISTER                                  READ/WRITE  COMMENTS

                    16C550 COMPATIBLE REGISTERS

0 00                RHR - Receive Holding Register            Read-only   LCR[7] = 0
                    THR - Transmit Holding Register           Write-only

0 00                DLL - Div Latch Low Byte                  Read/Write  LCR[7] = 1, LCR  0xBF
0 01                DLM - Div Latch High Byte                 Read/Write  LCR[7] = 1, LCR  0xBF

0 00                DREV - Device Revision Code               Read-only       DLL, DLM = 0x00,
                                                                          LCR[7] = 1, LCR  0xBF

0 01                DVID - Device Identification Code         Read-only      DLL, DLM = 0x00,
                                                                          LCR[7] = 1, LCR  0xBF

0 01                IER - Interrupt Enable Register           Read/Write  LCR[7] = 0

0 10                ISR - Interrupt Status Register           Read-only   LCR[7] = 0
                    FCR - FIFO Control Register               Write-only

0 11                LCR - Line Control Register               Read/Write

1 00                MCR - Modem Control Register              Read/Write  LCR[7] = 0

1 01                LSR - Line Status Register                Read-only   LCR[7] = 0
                    Reserved                                  Write-only

1 10                MSR - Modem Status Register               Read-only   LCR[7] = 0
                    Reserved                                  Write-only

1 11                SPR - Scratch Pad Register                Read/Write LCR[7] = 0, FCTR[6] = 0

1 11                FLVL - RX/TX FIFO Level Counter Register  Read-only   LCR[7] = 0, FCTR[6] = 1

1 11                EMSR - Enhanced Mode Select Register      Write-only  LCR[7] = 0, FCTR[6] = 1

                                       ENHANCED REGISTERS

0 00                TRG - RX/TX FIFO Trigger Level Register   Write-only  LCR = 0xBF
                    FC - RX/TX FIFO Level Counter Register    Read-only

0 01                FCTR - Feature Control Register           Read/Write  LCR = 0xBF

0 10                EFR - Enhanced Function Register          Read/Write  LCR = 0xBF

1 00                Xon-1 - Xon Character 1                   Read/Write  LCR = 0xBF

1 01                Xon-2 - Xon Character 2                   Read/Write  LCR = 0xBF

1 10                Xoff-1 - Xoff Character 1                 Read/Write  LCR = 0xBF

1 11                Xoff-2 - Xoff Character 2                 Read/Write  LCR = 0xBF

                                                     19
                                                                                                         XR16L2750
                                                               2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                           REV. 1.0.0

.

        TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1

   ADDRESS REG READ/  BIT-7  BIT-6     BIT-5       BIT-4       BIT-3 BIT-2 BIT-1 BIT-0 COMMENT
    A2-A0 NAME WRITE

                             16C550 Compatible Registers

   0 0 0 RHR RD Bit-7 Bit-6 Bit-5 Bit-4                        Bit-3 Bit-2 Bit-1 Bit-0

   0 0 0 THR WR Bit-7 Bit-6 Bit-5 Bit-4                        Bit-3 Bit-2 Bit-1 Bit-0

   001  IER RD/WR 0/         0/        0/              0/      Modem RX Line TX              RX

                      CTS Int. RTS Int. Xoff Int.  Sleep       Stat. Int.  Stat. Empty Data
                      Enable Enable Enable         Mode        Enable
                                                   Enable                  Int.       Int    Int.

                                                                           Enable Enable Enable

   010  ISR  RD FIFOs FIFOs            0/              0/      INT         INT        INT    INT LCR[7] = 0
   010  FCR
                      Enabled Enabled  INT             INT     Source Source Source Source
                                                                Bit-3 Bit-2 Bit-1 Bit-0
                                       Source Source

                                       Bit-5 Bit-4

             WR RXFIFO RXFIFO 0/                       0/       DMA        TX         RX FIFOs
                                                               Mode
                      Trigger Trigger                          Enable      FIFO FIFO Enable
                                                TXFIFO TXFIFO
                                                                           Reset Reset
                                       Trigger Trigger

   011  LCR RD/WR Divisor Set TX Set Par- Even                 Parity      Stop        Word Word
   100                                                         Enable      Bits       Length Length
                      Enable Break     ity         Parity
                                                                                       Bit-1 Bit-0

        MCR RD/WR       0/       0/        0/      Internal OP2#/INT Rsrvd RTS# DTR#
                                       XonAny
                      BRG    IR Mode               Lopback Output (OP1#) Output Output
                      Pres-  ENable
                      caler                        Enable Enable                      Control Control

   101  LSR RD RX FIFO THR & THR                    RX RX Fram- RX                     RX      RX      LCR[7] = 0
                               Global TSR Empty    Break ing Error Parity             Over-   Data
   110                          Error Empty                                            run   Ready
   111                                                                         Error  Error
   111
        MSR RD        CD#     RI#      DSR#        CTS#        Delta       Delta Delta Delta
                      Input  Input     Input       Input       CD#          RI# DSR# CTS#

        SPR RD/WR Bit-7      Bit-6     Bit-5           Bit-4   Bit-3       Bit-2      Bit-1  Bit-0 LCR[7] = 0
                                                                                                       FCTR[6]=0

        EMSR WR        16X      LSR    Auto        Auto          Auto      Rsrvd      Rx/Tx  Rx/Tx
                               Error   RTS         RTS          RS485                 FIFO   FIFO
                      Sam-     Inter-  Hyst.       Hyst.        Output                Count  Count
                      pling    rupt.   bit-3       bit-2       Inversion
                      Rate   Imd/Dly#                                                                  LCR[7] = 0
                      Mode                                                                             FCTR[6]=1

   1 1 1 FLVL RD Bit-7 Bit-6 Bit-5 Bit-4                       Bit-3 Bit-2 Bit-1 Bit-0

                                                   20
XR16L2750                                                                              
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

     TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1

ADDRESS REG READ/  BIT-7       BIT-6     BIT-5    BIT-4       BIT-3 BIT-2 BIT-1 BIT-0 COMMENT
A2-A0 NAME WRITE

                               Baud Rate Generator Divisor

000  DLL RD/WR Bit-7           Bit-6 Bit-5 Bit-4              Bit-3      Bit-2  Bit-1  Bit-0 LCR[7] = 1
001  DLM RD/WR Bit-7                                                     Bit-2  Bit-1            LCR  0xBF
                               Bit-6 Bit-5 Bit-4              Bit-3
                                                                                       Bit-0

0 0 0 DREV RD      Bit-7       Bit-6     Bit-5        Bit-4   Bit-3      Bit-2  Bit-1  Bit-0  LCR[7] = 1
0 0 1 DVID RD        0           0         0            0       1          0      1      0    LCR  0xBF
                                                                                               DLL=0x00
                                                                                              DLM=0x00

                                         Enhanced Registers

0 0 0 TRG WR Bit-7 Bit-6 Bit-5 Bit-4                          Bit-3 Bit-2 Bit-1 Bit-0

000  FC   RD       Bit-7       Bit-6     Bit-5    Bit-4       Bit-3 Bit-2       Bit-1  Bit-0
001
     FCTR RD/WR RX/TX SCPAD               Trig     Trig         Auto     RX IR  Auto   Auto
                              Mode Swap  Table    Table        RS485     Input  RTS    RTS
                                         Bit-1    Bit-0       Direction   Inv.  Hyst   Hyst
                                                               Control          Bit-1  Bit-0

010  EFR  RD/WR Auto            Auto     Special   Enable     Soft-      Soft-  Soft-  Soft-
                        CTS     RTS       Char                ware       ware   ware   ware
                               Enable    Select   IER [7:4],  Flow       Flow   Flow   Flow   LCR=0XBF
                       Enable                     ISR [5:4],  Cntl       Cntl   Cntl   Cntl
                                                  FCR[5:4],   Bit-3
                                                                         Bit-2  Bit-1  Bit-0
                                                  MCR[7:5]

1 0 0 XON1 RD/WR Bit-7 Bit-6 Bit-5 Bit-4                      Bit-3 Bit-2 Bit-1 Bit-0

1 0 1 XON2 RD/WR Bit-7 Bit-6 Bit-5 Bit-4                      Bit-3 Bit-2 Bit-1 Bit-0

110  XOFF1 RD/WR   Bit-7       Bit-6     Bit-5        Bit-4   Bit-3      Bit-2  Bit-1  Bit-0
111  XOFF2 RD/WR   Bit-7       Bit-6     Bit-5        Bit-4   Bit-3      Bit-2  Bit-1  Bit-0

4.0 INTERNAL REGISTER DESCRIPTIONS
4.1 Receive Holding Register (RHR) - Read- Only
See "Receiver" on page 12.
4.2 Transmit Holding Register (THR) - Write-Only
See "Transmitter" on page 11.
4.3 Interrupt Enable Register (IER) - Read/Write
The Interrupt Enable Register (IER) masks the interrupts from receive data ready, transmit empty, line status
and modem status registers. These interrupts are reported in the Interrupt Status Register (ISR).

                                                  21
                                                  XR16L2750
        2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                    REV. 1.0.0

4.3.1 IER versus Receive FIFO Interrupt Mode Operation

When the receive FIFO (FCR BIT-0 = 1) and receive interrupts (IER BIT-0 = 1) are enabled, the RHR interrupts
(see ISR bits 2 and 3) status will reflect the following:
A. The receive data available interrupts are issued to the host when the FIFO has reached the programmed

     trigger level. It will be cleared when the FIFO drops below the programmed trigger level.

B. FIFO level will be reflected in the ISR register when the FIFO trigger level is reached. Both the ISR register
     status bit and the interrupt will be cleared when the FIFO drops below the trigger level.

C. The receive data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to
     the receive FIFO. It is reset when the FIFO is empty.

4.3.2 IER versus Receive/Transmit FIFO Polled Mode Operation

When FCR BIT-0 equals a logic 1 for FIFO enable; resetting IER bits 0-3 enables the XR16L2750 in the FIFO
polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can
be used in the polled mode by selecting respective transmit or receive control bit(s).
A. LSR BIT-0 indicates there is data in RHR or RX FIFO.

B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid.

C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any.

D. LSR BIT-5 indicates THR is empty.

E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty.

F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO.

IER[0]: RHR Interrupt Enable

The receive data ready interrupt will be issued when RHR has a data character in the non-FIFO mode or when
the receive FIFO has reached the programmed trigger level in the FIFO mode.
Logic 0 = Disable the receive data ready interrupt (default).
Logic 1 = Enable the receiver data ready interrupt.

IER[1]: THR Interrupt Enable

This bit enables the Transmit Ready interrupt which is issued whenever the THR becomes empty in the non-
FIFO mode or when data in the FIFO falls below the programmed trigger level in the FIFO mode. If the THR is
empty when this bit is enabled, an interrupt will be generated.
Logic 0 = Disable Transmit Ready interrupt (default).
Logic 1 = Enable Transmit Ready interrupt.

IER[2]: Receive Line Status Interrupt Enable

If any of the LSR register bits 1, 2, 3 or 4 is a logic 1, it will generate an interrupt to inform the host controller
about the error status of the current data byte in FIFO. LSR bit-1 generates an interrupt immediately when the
character has been received. LSR bits 2-4 generate an interrupt when the character with errors is read out of
the FIFO (default). Instead, LSR bits 2-4 can be programmed to generate an interrupt immediately, by setting
EMSR bit-6 to a logic 1.

Logic 0 = Disable the receiver line status interrupt (default).
Logic 1 = Enable the receiver line status interrupt.

IER[3]: Modem Status Interrupt Enable

Logic 0 = Disable the modem status register interrupt (default).
Logic 1 = Enable the modem status register interrupt.

IER[4]: Sleep Mode Enable (requires EFR bit-4 = 1)

Logic 0 = Disable Sleep Mode (default).
Logic 1 = Enable Sleep Mode. See Sleep Mode section for further details.

    22
XR16L2750                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

IER[5]: Xoff Interrupt Enable (requires EFR bit-4=1)

Logic 0 = Disable the software flow control, receive Xoff interrupt. (default)
Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for

  details.

IER[6]: RTS# Output Interrupt Enable (requires EFR bit-4=1)

Logic 0 = Disable the RTS# interrupt (default).
Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when the RTS# pin makes a transition

  from low to high.

IER[7]: CTS# Input Interrupt Enable (requires EFR bit-4=1)

Logic 0 = Disable the CTS# interrupt (default).
Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from

  low to high.

4.4 Interrupt Status Register (ISR) - Read-Only

The UART provides multiple levels of prioritized interrupts to minimize external software interaction. The
Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the
ISR will give the user the current highest pending interrupt level to be serviced, others are queued up to be
serviced next. No other interrupts are acknowledged until the pending interrupt is serviced. The Interrupt
Source Table, Table 9, shows the data values (bit 0-5) for the interrupt priority levels and the interrupt sources
associated with each of these interrupt levels.

4.4.1 Interrupt Generation:

LSR is by any of the LSR bits 1, 2, 3 and 4.
RXRDY is by RX trigger level.
RXRDY Time-out is by a 4-char plus 12 bits delay timer.
TXRDY is by TX trigger level or TX FIFO empty (or transmitter empty in auto RS-485 control).
MSR is by any of the MSR bits 0, 1, 2 and 3.
Receive Xoff/Special character is by detection of a Xoff or Special character.
CTS# is when its transmitter toggles the input pin (from low to high) during auto CTS flow control enabled by

  EFR bit-7.

RTS# is when its receiver toggles the output pin (from low to high) during auto RTS flow control enabled by

  EFR bit-6.

4.4.2 Interrupt Clearing:

LSR interrupt is cleared by a read to the LSR register (but flags and tags not cleared until character(s) that

  generated the interrupt(s) has been emptied or cleared from FIFO).

RXRDY interrupt is cleared by reading data until FIFO falls below the trigger level.
RXRDY Time-out interrupt is cleared by reading RHR.
TXRDY interrupt is cleared by a read to the ISR register or writing to THR.
MSR interrupt is cleared by a read to the MSR register.
Xoff or Special character interrupt is cleared by a read to ISR.
RTS# and CTS# flow control interrupts are cleared by a read to the MSR register.

                                       23
                                                                                              XR16L2750
                                                    2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                REV. 1.0.0

]

                   TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL

   PRIORITY        ISR REGISTER STATUS BITS                        SOURCE OF INTERRUPT

   LEVEL BIT-5  BIT-4 BIT-3 BIT-2 BIT-1      BIT-0

   1         0  0  0  1  1                       0 LSR (Receiver Line Status Register)

   2         0  0  1  1  0                       0 RXRDY (Receive Data Time-out)

   3         0  0  0  1  0                       0 RXRDY (Received Data Ready)

   4         0  0  0  0  1                       0 TXRDY (Transmit Ready)

   5         0  0  0  0  0                       0 MSR (Modem Status Register)

   6         0  1  0  0  0                       0 RXRDY (Received Xoff or Special character)

   7         1  0  0  0  0                       0 CTS#, RTS# change of state

   -         0  0  0  0  0                       1 None (default)

ISR[0]: Interrupt Status

Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt

  service routine.

Logic 1 = No interrupt pending (default condition).

ISR[3:1]: Interrupt Status

These bits indicate the source for a pending interrupt at interrupt priority levels (See Interrupt Source Table 9).

ISR[5:4]: Interrupt Status

These bits are enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that the receiver detected a data
match of the Xoff character(s). Note that once set to a logic 1, the ISR bit-4 will stay a logic 1 until a Xon
character is received. ISR bit-5 indicates that CTS# or RTS# has changed state.

ISR[7:6]: FIFO Enable Status

These bits are set to a logic 0 when the FIFOs are disabled. They are set to a logic 1 when the FIFOs are
enabled.

4.5 FIFO Control Register (FCR) - Write-Only

This register is used to enable the FIFOs, clear the FIFOs, set the transmit/receive FIFO trigger levels, and
select the DMA mode. The DMA, and FIFO modes are defined as follows:

FCR[0]: TX and RX FIFO Enable

Logic 0 = Disable the transmit and receive FIFO (default).
Logic 1 = Enable the transmit and receive FIFOs. This bit must be set to logic 1 when other FCR bits are

  written or they will not be programmed.

FCR[1]: RX FIFO Reset

This bit is only active when FCR bit-0 is a `1'.

Logic 0 = No receive FIFO reset (default)
Logic 1 = Reset the receive FIFO pointers and FIFO level counter logic (the receive shift register is not

  cleared or altered). This bit will return to a logic 0 after resetting the FIFO.

                                             24
XR16L2750                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

FCR[2]: TX FIFO Reset

This bit is only active when FCR bit-0 is a `1'.

Logic 0 = No transmit FIFO reset (default).
Logic 1 = Reset the transmit FIFO pointers and FIFO level counter logic (the transmit shift register is not

  cleared or altered). This bit will return to a logic 0 after resetting the FIFO.

FCR[3]: DMA Mode Select

Controls the behavior of the TXRDY# and RXRDY# pins. See DMA operation section for details.

Logic 0 = Normal Operation (default).
Logic 1 = DMA Mode.

FCR[5:4]: Transmit FIFO Trigger Select

(logic 0 = default, TX trigger level = one)
These 2 bits set the trigger level for the transmit FIFO. The UART will issue a transmit interrupt when the
number of characters in the FIFO falls below the selected trigger level, or when it gets empty in case that the
FIFO did not get filled over the trigger level on last re-load. Table 10 below shows the selections. EFR bit-4
must be set to `1' before these bits can be accessed. Note that the receiver and the transmitter cannot use
different trigger tables. Whichever selection is made last applies to both the RX and TX side.

                                       25
                                                                                                XR16L2750
                                                      2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                  REV. 1.0.0

FCR[7:6]: Receive FIFO Trigger Select

(logic 0 = default, RX trigger level =1)
The FCTR Bits 5-4 are associated with these 2 bits. These 2 bits are used to set the trigger level for the receive
FIFO. The UART will issue a receive interrupt when the number of the characters in the FIFO crosses the
trigger level. Table 10 shows the complete selections. Note that the receiver and the transmitter cannot use
different trigger tables. Whichever selection is made last applies to both the RX and TX side.

              TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER LEVEL SELECTION

FCTR   FCTR   FCR    FCR    FCR    FCR  RECEIVE       TRANSMIT        COMPATIBILITY
BIT-5  BIT-4  BIT-7  BIT-6  BIT-5
                                   BIT-4 TRIGGER LEVEL TRIGGER LEVEL
   0      0     0      0      0
                0      1           0                  1 (default) Table-A. 16C550, 16C2550,
   0      1     1      0      0
                1      1      0         1 (default)                   16C2552, 16C554, 16C580
                              1
                       0      1             4                         compatible.
                       1
                       0      0             8
                       1      0
                              1         14
                       0      1
                       1           0                  16              Table-B. 16C650A compatible.
                       0      X    1
                       1           0                  8
                       X           1
                                                      24
                                                   8
                                                  16  30
                                                  24
              0                                   28
              0
              1
              1

1      0                           0                  8               Table-C. 16C654 compatible.
                                   1
                                   0                  16
                                   1
                                                      32
                                                   8
                                                  16  56
                                                  56
              0                                   60
              0
              1
              1

1      1      X                    X Programmable Programmable Table-D. 16C850, 16L2752,

                                        via TRG       via TRG 16C2850, 16C2852, 16C854,

                                        register.     register. 16C864, 16C872 compatible.

                                        FCTR[7] = 0. FCTR[7] = 1.

                                        26
XR16L2750                                                                                       
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

4.6 Line Control Register (LCR) - Read/Write

The Line Control Register is used to specify the asynchronous data communication format. The word or
character length, the number of stop bits, and the parity are selected by writing the appropriate bits in this
register.

LCR[1:0]: TX and RX Word Length Select

These two bits specify the word length to be transmitted or received.

BIT-1                                  BIT-0        WORD LENGTH

0                                      0            5 (default)

0                                      1            6

1                                      0            7

1                                      1            8

LCR[2]: TX and RX Stop-bit Length Select
The length of stop bit is specified by this bit in conjunction with the programmed word length.

BIT-2   WORD                                        STOP BIT LENGTH
                                                      (BIT TIME(S))
       LENGTH

0                                      5,6,7,8      1 (default)

1                                      5            1-1/2

1                                      6,7,8        2

LCR[3]: TX and RX Parity Select

Parity or no parity can be selected via this bit. The parity bit is a simple way used in communications for data
integrity check. See Table 11 for parity selection summary below.

Logic 0 = No parity.
Logic 1 = A parity bit is generated during the transmission while the receiver checks for parity error of the

  data character received.

LCR[4]: TX and RX Parity Select

If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR BIT-4 selects the even or odd parity format.

Logic 0 = ODD Parity is generated by forcing an odd number of logic 1's in the transmitted character. The

  receiver must be programmed to check the same format (default).

Logic 1 = EVEN Parity is generated by forcing an even number of logic 1's in the transmitted character. The

  receiver must be programmed to check the same format.

LCR[5]: TX and RX Parity Select

If the parity bit is enabled, LCR BIT-5 selects the forced parity format.

LCR BIT-5 = logic 0, parity is not forced (default).
LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive

  data.

LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive

  data.

                                                27
                                                        XR16L2750
              2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                          REV. 1.0.0

       TABLE 11: PARITY SELECTION

    LCR BIT-5 LCR BIT-4 LCR BIT-3 PARITY SELECTION

    X  X  0   No parity

    0  0  1   Odd parity

    0  1  1   Even parity

    1  0  1   Force parity to mark,

                                   "1"

    1  1  1   Forced parity to

              space, "0"

LCR[6]: Transmit Break Enable

When enabled, the Break control bit causes a break condition to be transmitted (the TX output is forced to a
"space', logic 0, state). This condition remains, until disabled by setting LCR bit-6 to a logic 0.

Logic 0 = No TX break condition. (default)
Logic 1 = Forces the transmitter output (TX) to a "space", logic 0, for alerting the remote receiver of a line

  break condition.

LCR[7]: Baud Rate Divisors Enable

Baud rate generator divisor (DLL/DLM) enable.

Logic 0 = Data registers are selected. (default)
Logic 1 = Divisor latch registers are selected.

4.7 Modem Control Register (MCR) or General Purpose Outputs Control - Read/Write

The MCR register is used for controlling the serial/modem interface signals or general purpose inputs/outputs.

MCR[0]: DTR# Output

The DTR# pin is a modem control output. If the modem interface is not used, this output may be used as a
general purpose output.

Logic 0 = Force DTR# output to a logic 1 (default).
Logic 1 = Force DTR# output to a logic 0.

MCR[1]: RTS# Output

The RTS# pin is a modem control output and may be used for automatic hardware flow control by enabled by
EFR bit-6. If the modem interface is not used, this output may be used as a general purpose output.

Logic 0 = Force RTS# output to a logic 1 (default).
Logic 1 = Force RTS# output to a logic 0.

MCR[2]: Reserved

OP1# is not available as an output pin on the 2750. But it is available for use during Internal Loopback Mode. In
the Loopback Mode, this bit is used to write the state of the modem RI# interface signal.

MCR[3]: OP2# Output / INT Output Enable

This bit enables or disables the operation of INT, interrupt output. If INT output is not used, OP2# can be used
as a general purpose output.

Logic 0 = INT (A-B) outputs disabled (three state mode) and OP2# output set to a logic 1 (default).
Logic 1 = INT (A-B) outputs enabled (active mode) and OP2# output set to a logic 0.

          28
XR16L2750                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

MCR[4]: Internal Loopback Enable

Logic 0 = Disable loopback mode (default).
Logic 1 = Enable local loopback mode, see loopback section and Figure 13.

MCR[5]: Xon-Any Enable

Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default).
Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation.

  The RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and
  the 2750 is programmed to use the Xon/Xoff flow control.

MCR[6]: Infrared Encoder/Decoder Enable

Logic 0 = Enable the standard modem receive and transmit input/output interface. (Default)
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the

  infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
  requirement. While in this mode, the infrared TX output will be a logic 0 during idle data conditions.

MCR[7]: Clock Prescaler Select

Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable

  Baud Rate Generator without further modification, i.e., divide by one (default).

Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and

  feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.

4.8 Line Status Register (LSR) - Read Only

This register provides the status of data transfers between the UART and the host.

LSR[0]: Receive Data Ready Indicator

Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.

LSR[1]: Receiver Overrun Error Flag

Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens

  when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register is
  overwritten. Note that under this condition the data byte in the receive shift register is not transferred into the
  FIFO, therefore the data in the FIFO is not corrupted by the error.

LSR[2]: Receive Data Parity Error Tag

Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.

  This error is associated with the character available for reading in RHR.

LSR[3]: Receive Data Framing Error Tag

Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with

  the character available for reading in RHR.

LSR[4]: Receive Break Error Tag

Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was a logic 0 for at least one character frame time). In the

  FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX input
  returns to the idle condition, "mark" or logic 1.

                                       29
                                                  XR16L2750
        2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                    REV. 1.0.0

LSR[5]: Transmit Holding Register Empty Flag

This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.

LSR[6]: THR and TSR Empty Flag

This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or TSR
contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and transmit
shift register are both empty.

LSR[7]: Receive FIFO Data Error Flag

Logic 0 = No FIFO error (default).
Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error

  or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the
  RX FIFO.

4.9 Modem Status Register (MSR) - Read Only

This register provides the current state of the modem interface input signals. Lower four bits of this register are
used to indicate the changed information. These bits are set to a logic 1 whenever a signal from the modem
changes state. These bits may be used for general purpose inputs when they are not used with modem
signals.

MSR[0]: Delta CTS# Input Flag

Logic 0 = No change on CTS# input (default).
Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt

  will be generated if MSR interrupt is enabled (IER bit-3).

MSR[1]: Delta DSR# Input Flag

Logic 0 = No change on DSR# input (default).
Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt

  will be generated if MSR interrupt is enabled (IER bit-3).

MSR[2]: Delta RI# Input Flag

Logic 0 = No change on RI# input (default).
Logic 1 = The RI# input has changed from a logic 0 to a logic 1, ending of the ringing signal. A modem status

  interrupt will be generated if MSR interrupt is enabled (IER bit-3).

MSR[3]: Delta CD# Input Flag

Logic 0 = No change on CD# input (default).
Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem

  status interrupt will be generated if MSR interrupt is enabled (IER bit-3).

MSR[4]: CTS Input Status

CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto
CTS (EFR bit-7). Auto CTS flow control allows starting and stopping of local data transmissions based on the
modem CTS# signal. A logic 1 on the CTS# pin will stop UART transmitter as soon as the current character
has finished transmission, and a logic 0 will resume data transmission. Normally MSR bit-4 bit is the
compliment of the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR
register. The CTS# input may be used as a general purpose input when the modem interface is not used.

MSR[5]: DSR Input Status

DSR# (active high, logical 1). Normally this bit is the compliment of the DSR# input. In the loopback mode, this
bit is equivalent to the DTR# bit in the MCR register. The DSR# input may be used as a general purpose input
when the modem interface is not used.

    30
XR16L2750                                                            
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

MSR[6]: RI Input Status

RI# (active high, logical 1). Normally this bit is the compliment of the RI# input. In the loopback mode this bit is
equivalent to bit-2 in the MCR register. The RI# input may be used as a general purpose input when the
modem interface is not used.

MSR[7]: CD Input Status

CD# (active high, logical 1). Normally this bit is the compliment of the CD# input. In the loopback mode this bit
is equivalent to bit-3 in the MCR register. The CD# input may be used as a general purpose input when the
modem interface is not used.

4.10 Scratch Pad Register (SPR) - Read/Write

This is a 8-bit general purpose register for the user to store temporary data. The content of this register is
preserved during sleep mode but becomes 0xFF (default) after a reset or a power off-on cycle.

4.11 Enhanced Mode Select Register (EMSR)

This register replaces SPR (during a Write) and is accessible only when FCTR[6] = 1.

EMSR[1:0]: Receive/Transmit FIFO Level Count (Write-Only)

When Scratchpad Swap (FCTR[6]) is asserted, EMSR bits 1-0 controls what mode the FIFO Level Counter is
operating in.

   TABLE 12: SCRATCHPAD SWAP SELECTION

FCTR[6] EMSR[1] EMSR[0] Scratchpad is

0  X                                   X      Scratchpad

1  X                                   0      RX FIFO Level Counter

                                              Mode

1  0                                   1      TX FIFO Level Counter

                                              Mode

1  1                                   1      Alternate RX/TX FIFO

                                              Counter Mode

During Alternate RX/TX FIFO Level Counter Mode, the first value read after EMSR bits 1-0 have been asserted
will always be the RX FIFO Level Counter. The second value read will correspond with the TX FIFO Level
Counter. The next value will be the RX FIFO Level Counter again, then the TX FIFO Level Counter and so on
and so forth.

EMSR[2]: Reserved

EMSR[3]: Automatic RS485 Half-Duplex Control Output Inversion

Logic 0 = RTS# output is a logic 0 during TX and a logic 1 during RX (default, compatible with 16C2850).
Logic 1 = RTS# output is a logic 1 during TX and a logic 0 during RX.

                                          31
                                                                                               XR16L2750
                                                     2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                 REV. 1.0.0

EMSR[5:4]: Extended RTS Hysteresis

           TABLE 13: AUTO RTS HYSTERESIS

    EMSR                            EMSR   FCTR   FCTR        RTS#
    BIT-5                           BIT-4  BIT-1  BIT-0   HYSTERESIS
                                                         (CHARACTERS)

    0                               0      0      0      0

    0                               0      0      1      4

    0                               0      1      0      6

    0                               0      1      1      8

    0                               1      0      0      8

    0                               1      0      1      16

    0                               1      1      0      24

    0                               1      1      1      32

    1                               0      0      0      40

    1                               0      0      1      44

    1                               0      1      0      48

    1                               0      1      1      52

    1                               1      0      0      12

    1                               1      0      1      20

    1                               1      1      0      28

    1                               1      1      1      36

EMSR[6]: LSR Interrupt Mode

Logic 0 = LSR Interrupt Delayed (for 16C2550 compatibility, default). LSR bits 2, 3, and 4 will generate an

  interrupt when the character with the error is in the RHR.

Logic 1 = LSR Interrupt Immediate. LSR bits 2, 3, and 4 will generate an interrupt as soon as the character is

  received into the FIFO.

EMSR[7]: 16X Sampling Rate Mode

Logic 0 = 8X Sampling Rate.
Logic 1 = 16X Sampling Rate (for 16C550 compatibility, default).

4.12 FIFO Level Register (FLVL) - Read-Only

The FIFO Level Register replaces the Scratchpad Register (during a Read) when FCTR[6] = 1. Note that this is
not identical to the FIFO Data Count Register which can be accessed when LCR = 0xBF.

FLVL[7:0]: FIFO Level Register

This register provides the FIFO counter level for the RX FIFO or the TX FIFO or both depending on EMSR[1:0].
See Table 12 for details.

4.13 Baud Rate Generator Registers (DLL and DLM) - Read/Write

The concatenation of the contents of DLM and DLL gives the 16-bit divisor value which is used to calculate the
baud rate:

Baud Rate = (Clock Frequency / 16) / Divisor

See MCR bit-7 and the baud rate table also.

4.14 Device Identification Register (DVID) - Read Only

This register contains the device ID (0x0A for XR16L2750). Prior to reading this register, DLL and DLM should
be set to 0x00.

                                              32
XR16L2750                                         
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

4.15 Device Revision Register (DREV) - Read Only

This register contains the device revision information. For example, 0x01 means revision A. Prior to reading
this register, DLL and DLM should be set to 0x00.

4.16 Trigger Level Register (TRG) - Write-Only

User Programmable Transmit/Receive Trigger Level Register.

TRG[7:0]: Trigger Level Register

These bits are used to program desired trigger levels when trigger Table-D is selected. FCTR bit-7 selects
between programming the RX Trigger Level (a logic 0) and the TX Trigger Level (a logic 1).

4.17 RX/TX FIFO Level Count Register (FC) - Read-Only

This register is accessible when LCR = 0xBF. Note that this register is not identical to the FIFO Level Count
Register which is located in the general register set when FCTR bit-6 = 1 (Scratchpad Register Swap). It is
suggested to read the FIFO Level Count Register at the Scratchpad Register location when FCTR bit-6 = 1.
See Table 12.

FC[7:0]: RX/TX FIFO Level Count

Receive/Transmit FIFO Level Count. Number of characters in Receiver FIFO (FCTR[7] = 0) or Transmitter FIFO
(FCTR[7] = 1) can be read via this register.

4.18 Feature Control Register (FCTR) - Read/Write

This register controls the XR16L2750 new functions that are not available in ST16C2450 or ST16C2550.

FCTR[1:0]: RTS Hysteresis

User selectable RTS# hysteresis levels for hardware flow control application. After reset, these bits are set to
"0" to select the next trigger level for hardware flow control. See Table 13 for more details.

FCTR[2]: IrDa RX Inversion

Logic 0 = Select RX input as encoded IrDa data (Idle state will be logic 0).
Logic 1 = Select RX input as inverted encoded IrDa data (Idle state will be logic 1).

FCTR[3]: Auto RS-485 Direction Control

Logic 0 = Standard ST16C550 mode. Transmitter generates an interrupt when transmit holding register

  becomes empty and transmit shift register is shifting data out.

Logic 1 = Enable Auto RS485 Direction Control function. The direction control signal, RTS# pin, changes its

  output logic state from low to high one bit time after the last stop bit of the last character is shifted out. Also,
  the Transmit interrupt generation is delayed until the transmitter shift register becomes empty. The RTS#
  output pin will automatically return to a logic low when a data byte is loaded into the TX FIFO. However,
  RTS# behavior can be inverted by setting EMSR[3] = 1.

FCTR[5:4]: Transmit/Receive Trigger Table Select

See Table 10 for more details.

       TABLE 14: TRIGGER TABLE SELECT

FCTR   FCTR                                TABLE
BIT-5  BIT-4

0      0 Table-A (TX/RX)

0      1 Table-B (TX/RX)

1      0 Table-C (TX/RX)

1      1 Table-D (TX/RX)

                                       33
                                                                                      XR16L2750
                                            2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                        REV. 1.0.0

FCTR[6]: Scratchpad Swap

Logic 0 = Scratch Pad register is selected as general read and write register. ST16C550 compatible mode.
Logic 1 = FIFO Count register (Read-Only), Enhanced Mode Select Register (Write-Only). Number of

  characters in transmit or receive FIFO can be read via scratch pad register when this bit is set. Enhanced
  Mode Select Register is selected when it is written into.

FCTR[7]: Programmable Trigger Register Select

Logic 0 = Registers TRG and FC selected for RX.
Logic 1 = Registers TRG and FC selected for TX.

4.19 Enhanced Feature Register (EFR)

Enhanced features are enabled or disabled using this register. Bit 0-3 provide single or dual consecutive
character software flow control selection (see Table 15). When the Xon1 and Xon2 and Xoff1 and Xoff2 modes
are selected, the double 8-bit words are concatenated into two sequential characters. Caution: note that
whenever changing the TX or RX flow control bits, always reset all bits back to logic 0 (disable) before
programming a new setting.

EFR[3:0]: Software Flow Control Select

Single character and dual sequential characters software flow control is supported. Combinations of software
flow control can be selected by programming these bits.

                      TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS

EFR BIT-3  EFR BIT-2  EFR BIT-1  EFR BIT-0  TRANSMIT AND RECEIVE SOFTWARE FLOW CONTROL
CONT-3     CONT-2     CONT-1     CONT-0
     0
     0     0          0          0          No TX and RX flow control (default and reset)
     1
     0     0          X          X          No transmit flow control
     1
     X     0          X          X          Transmit Xon1, Xoff1
     X
     X     1          X          X          Transmit Xon2, Xoff2
     1
           1          X          X          Transmit Xon1 and Xon2, Xoff1 and Xoff2
     0
           X          0          0          No receive flow control
     1
           X          1          0          Receiver compares Xon1, Xoff1
     0
           X          0          1          Receiver compares Xon2, Xoff2

           0          1          1          Transmit Xon1, Xoff1

                                            Receiver compares Xon1 or Xon2, Xoff1 or Xoff2

           1          1          1          Transmit Xon2, Xoff2

                                            Receiver compares Xon1 or Xon2, Xoff1 or Xoff2

           1          1          1          Transmit Xon1 and Xon2, Xoff1 and Xoff2,

                                            Receiver compares Xon1 and Xon2, Xoff1 and Xoff2

           0          1          1          No transmit flow control,

                                            Receiver compares Xon1 and Xon2, Xoff1 and Xoff2

                                    34
XR16L2750                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

EFR[4]: Enhanced Function Bits Enable

Enhanced function control bit. This bit enables IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 to be
modified. After modifying any enhanced bits, EFR bit-4 can be set to a logic 0 to latch the new values. This
feature prevents legacy software from altering or overwriting the enhanced functions once set. Normally, it is
recommended to leave it enabled, logic 1.

Logic 0 = modification disable/latch enhanced features. IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR

  bits 5-7 are saved to retain the user settings. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and
  MCR bits 5-7are set to a logic 0 to be compatible with ST16C550 mode (default).

Logic 1 = Enables the above-mentioned register bits to be modified by the user.

EFR[5]: Special Character Detect Enable

Logic 0 = Special Character Detect Disabled (default).
Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with

  data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
  to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
  flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= `10') then flow control and special character work
  normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= `01') then flow control works
  normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
  interrupt, if enabled via IER bit-5.

EFR[6]: Auto RTS Flow Control Enable

RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is selected,
an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and RTS de-
asserts to a logic 1 at the next upper trigger level or hysteresis level. RTS# will return to a logic 0 when FIFO
data falls below the next lower trigger level. The RTS# output must be asserted (logic 0) before the auto RTS
can take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled.

Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.

EFR[7]: Auto CTS Flow Control Enable

Automatic CTS Flow Control.

Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic

  1. Data transmission resumes when CTS# returns to a logic 0.

4.19.1 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write

These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see Table 6.

                                       35
                                                                                  XR16L2750
                                        2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                    REV. 1.0.0

         TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B

REGISTERS                                             RESET STATE

DLM and DLL  DLM = 0x00 and DLL = 0x01. Only resets to these values during a
             power up. They do not reset when the Reset Pin is asserted.
      RHR
             Bits 7-0 = 0xXX

    THR      Bits 7-0 = 0xXX

    IER      Bits 7-0 = 0x00

    FCR      Bits 7-0 = 0x00

    ISR      Bits 7-0 = 0x01

    LCR      Bits 7-0 = 0x00

    MCR      Bits 7-0 = 0x00

    LSR      Bits 7-0 = 0x60

    MSR      Bits 3-0 = Logic 0

             Bits 7-4 = Logic levels of the inputs inverted

    SPR      Bits 7-0 = 0xFF

    EMSR     Bits 7-0 = 0x80

    FLVL     Bits 7-0 = 0x00

    EFR      Bits 7-0 = 0x00

    XON1     Bits 7-0 = 0x00

    XON2     Bits 7-0 = 0x00

    XOFF1    Bits 7-0 = 0x00

    XOFF2    Bits 7-0 = 0x00

    FC       Bits 7-0 = 0x00

I/O SIGNALS                             RESET STATE

    TX       Logic 1

    OP2#     Logic 1

    RTS#     Logic 1

    DTR#     Logic 1

RXRDY#       Logic 1

TXRDY#       Logic 0

    INT      Three-State Condition

                                    36
XR16L2750                                                                                    
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

ABSOLUTE MAXIMUM RATINGS                                                       7 Volts
                                                                         GND-0.3V to 7V
Power Supply Range
Voltage at Any Pin                                                        -40o to +85oC
Operating Temperature                                                    -65o to +150oC
Storage Temperature
Package Dissipation                                                           500 mW

TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%)

Thermal Resistance (48-TQFP)                                          theta-ja =59oC/W, theta-jc = 16oC/W

Thermal Resistance (44-PLCC)                                          theta-ja = 50oC/W, theta-jc = 21oC/W

ELECTRICAL CHARACTERISTICS

DC ELECTRICAL CHARACTERISTICS

TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 2.25V TO 5.5V

                                         LIMITS               LIMITS          LIMITS

SYMBOL  PARAMETER                        2.5V                 3.3V            5.0V        UNITS  CONDITIONS
                                                                                            V
                                    MIN        MAX       MIN        MAX  MIN        MAX

VILCK   Clock Input Low Level       -0.3 0.2             -0.3 0.6        -0.5 0.6
VIHCK   Clock Input High Level
        Input Low Voltage           2.0 VCC              2.4 VCC         3.0 VCC          V
VIL    Input High Voltage
VIH    Output Low Voltage          -0.3 0.6             -0.3 0.8        -0.5 0.8         V
VOL
                                    2.0        5.5       2.0        5.5  2.2        5.5   V

                                                                                    0.4   V IOL = 6 mA

                                                                    0.4                   V IOL = 4 mA

                                               0.4                                        V IOL = 2 mA

VOH Output High Voltage                                                  2.4              V IOH = -6 mA

                                    1.8                  2.0                              V IOH = -1 mA
                                               10                                        V IOH = -400 uA
                                               10                  10
  IIL   Input Low Leakage Current                5                  10             10 uA
  IIH   Input High Leakage Current              1.2
  CIN   Input Pin Capacitance                    6                    5             10 uA
  ICC   Power Supply Current                                          2
ISLEEP  Sleep Current                                                15               5   pF

                                                                                      5   mA

                                                                                      30  uA See Test 1

Test 1: The following inputs must remain steady at VCC or GND state to minimize Sleep current: A0-A2, D0-
D7, IOR#, IOW#, CSA# and CSB#. Also, RXA and RXB inputs must idle at logic 1 state while asleep. Floating
inputs will result in sleep currents in the mA range.

                                                     37
                                                                                                        XR16L2750
                                                              2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                          REV. 1.0.0

AC ELECTRICAL CHARACTERISTICS

TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 2.25 TO 5.5V

                                         LIMITS               LIMITS           LIMITS

SYMBOL             PARAMETER             2.5                  3.3              5.0          UNIT  CONDITIONS

                                    MIN       MAX        MIN       MAX    MIN          MAX

CLK Clock Pulse Duration            50                   50               17                ns

OSC Oscillator Frequency                         16                   20               24 MHz

OSC External Clock Frequency                     24                   33               50 MHz

TAS Address Setup Time              15                   10               5                 ns

TAH Address Hold Time               15                   10               5                 ns

TCS Chip Select Width               66                   66               50                ns

TRD IOR# Strobe Width               50                   35               25                ns

TDY Read Cycle Delay                50                   40               30                ns

TRDV Data Access Time                            50                   50               35   ns

TDD Data Disable Time               0            35      0            35  0            35   ns

TWR IOW# Strobe Width               40                   40               25                ns

TDY Write Cycle Delay               50                   40               30                ns

TDS Data Setup Time                 15                   10               5                 ns

TDH Data Hold Time                  15                   10               5                 ns

TWDO Delay From IOW# To Output                   50                   50               40   ns 100 pF load

TMOD Delay To Set Interrupt From                 50                   40               35   ns 100 pF load

        MODEM Input

TRSI Delay To Reset Interrupt                    50                   40               35   ns 100 pF load
           From IOR#

TSSI Delay From Stop To Set Inter-               1                    1                1    Bclk

        rupt

TRRI    Delay From IOR# To Reset                 50                   45               40   ns 100 pF load
        Interrupt

TSI Delay From Stop To Interrupt                 50                   45               40   ns

TINT Delay From Initial INT Reset   8            24      8            24  8            24 Bclk

        To Transmit Start

TWRI Delay From IOW# To Reset                    50                   45               40   ns

        Interrupt

TSSR Delay From Stop To Set                      1                    1                1    Bclk
            RXRDY#

                                                     38
XR16L2750                                                                                       
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

AC ELECTRICAL CHARACTERISTICS

TA=0O TO 70OC (-40O TO +85OC FOR INDUSTRIAL GRADE PACKAGE), VCC IS 2.25 TO 5.5V

                                         LIMITS               LIMITS             LIMITS

SYMBOL  PARAMETER                        2.5                  3.3                5.0          UNIT  CONDITIONS

                                    MIN       MAX        MIN       MAX    MIN            MAX

TRR Delay From IOR# To Reset                     50                   45                 40   ns
           RXRDY#

TWT Delay From IOW# To Set                       50                   45                 40   ns
           TXRDY#

TSRT Delay From Center of Start To               8                    8                  8    Bclk

        Reset TXRDY#

TRST    Reset Pulse Width           40                   40                  40               ns
  N     Baud Rate Divisor
                                    1         216-1      1         216-1     1        216-1   -

Bclk Baud Clock                                      16X or 8X of data rate                   Hz

FIGURE 14. CLOCK TIMING     CLK                  CLK

        EXTERNAL
           CLOCK

                                    OSC

                                                     39
                                                                                                            XR16L2750
                                                                  2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                              REV. 1.0.0

FIGURE 15. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B

IOW #                         Active        TWDO
                       Change of state          Change of state
RTS#
DTR#

CD#                                               Change of state        Change of state
CTS#
DSR#                                        TMOD                         TMOD

INT                                                   Active             Active              Active
                                                      Active                                   Active
IOR#                                                               TRSI

RI#                                                                      Active

                                                                                                   TMOD
                                                                                             Change of state

FIGURE 16. DATA BUS READ TIMING

A0-A2                        Valid Address                               Valid Address
                  TAS                  TCS
                                                  TAH              TAS                       TAH
CSA#/                                TRD                     TDY                        TCS
CSB#
                                                  TDD                          TRD
IOR#

                       TRDV                                        TRDV                                             TDD
                                                                                             Valid Data
D0-D7                            Valid Data

                                                                                                                         RDTm

                                                  40
XR16L2750                                                                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

FIGURE 17. DATA BUS WRITE TIMING

A0-A2                       Valid Address                                   Valid Address
               TAS
CSA#/                                               TAH         TAS                        TAH
CSB#                                   TCS
                                                                            TCS
IOW#                                TWR
                                                           TDY
D0-D7
                                                                            TWR

                             TDS                    TDH                     TDS            TDH

                             Valid Data                                     Valid Data

                                                                                           16Write

FIGURE 18. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B

RX             Start  D0:D7  Stop                   D0:D7                        D0:D7
INT             Bit           Bit
RXRDY#
                                    TSSR                            TSSR                        TSSR

                                            1 Byte                 1 Byte                     1 Byte
                                            in RHR                in RHR                      in RHR

                                            TSSR                    TSSR                     TSSR

                                 Active                             Active                     Active
                                 Data                               Data                        Data
                                Ready                              Ready                       Ready
                                                                TRR                        TRR
                             TRR

IOR#
(Reading data
out of RHR)

                                                                                                RXNFM

                                                    41
                                                                                                               XR16L2750
                                                                     2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                                 REV. 1.0.0

FIGURE 19. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B

TX                    Start                Stop
                       Bit                  Bit
                              D0:D7                     D0:D7                     D0:D7
                                                      ISR is read                ISR is read
      IER[1]                  ISR is read
      enabled                                                                      TSRT

INT*

        TWRI                             TWRI                              TWRI
                              TSRT
                                                      TSRT

TXRDY#

                      TWT                        TWT                             TWT

IOW#                                                                                                            TXNonFIFO
(Loading data
into THR)

*INT is cleared when the ISR is read or when data is loaded into the THR.

FIGURE 20. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B

               Start
                Bit

RX                 S D0:D7 S D0:D7 T           D0:D7 S D0:D7 T S D0:D7 T S D0:D7 T S D0:D7 T

                      Stop                           TSSI                        RX FIFO drops
                       Bit                                                          below RX
                                            RX FIFO fills up to RX
INT                                        Trigger Level or RX Data               Trigger Level

                              TSSR                    Timeout                                       FIFO
                                                                                                 Empties

RXRDY#                                                                     TRRI  TRR

               First Byte is
               Received in

                 RX FIFO

IOR#
(Reading data out
of RX FIFO)

                                                                                              RXINTDMA#

                                                      42
XR16L2750                                                                                                      
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B

        Start               Stop
         Bit                 Bit

RX                 S D0:D7 S D0:D7 T             D0:D7 S D0:D7 T S D0:D7 T S D0:D7 T S D0:D7 T
INT
RXRDY#                                            TSSI                                          RX FIFO drops
                                                                                                   below RX

                                                                                                Trigger Level

                         RX FIFO fills up to RX             TSSR                                                 FIFO
                        Trigger Level or RX Data                                                               Empties

                                  Timeout

                                                                                          TRRI                 TRR

IOR#
(Reading data out
of RX FIFO)

                                                                                                                    RXFIFODMA

FIGURE 22. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B

               TX FIFO            Start    Stop                                                                 Last Data Byte
                 Empty             Bit      Bit                                                                   Transmitted

  TX                              S D0:D7 T       S D0:D7 T S D0:D7 T T S D0:D7 T S D0:D7 T                    S D0:D7 T
(Unloading)
                                                                                                                           TSRT
         IER[1]                   ISR is read                                        TSI        ISR is read
        enabled                                                                                                        TX FIFO
                                                                                                                         Empty
INT*

                                         TX FIFO fills up         TWRI                      TX FIFO drops
                                          to trigger level                                below trigger level

TXRDY#             Data in
                   TX FIFO

                                  TWT

  IOW#                                                                                                              TXDMA#
(Loading data

  into FIFO)

*INT is cleared when the ISR is read or when TX FIFO fills up to the trigger level.

                                                                  43
                                                                                                             XR16L2750
                                                                   2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                               REV. 1.0.0

FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B

             Start    Stop                                                                                                                         Last Data Byte
              Bit      Bit                                                                                                                           Transmitted

  TX                  S D0:D7 T S D0:D7 T         D0:D7 S D0:D7 T        S D0:D7 T S D0:D7 T                                                      S D0:D7 T
(Unloading)
                                                                                                                                              ISR Read
              IER[1]  ISR Read                                                                                                           TSI
             enabled                                               TSRT

INT*                            TX FIFO fills up      TWRI                                                                                 TX FIFO drops
TXRDY#                          to trigger level                                                                                         below trigger level
                                                  TX FIFO
                                                     Full                                                                                          At least 1
                                                                                                                                                empty location

                                                                                                                                                    in FIFO

                                                                                                                                    TWT                         TXDMA

  IOW#
(Loading data

  into FIFO)

*INT cleared when the ISR is read or when TX FIFO fills up to trigger level.

                                                  44
XR16L2750                                                                              
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 mm)

                                                      D

                                                      D1

                                           36                   25

             37                                                             24

                                                                                D1 D

             48                                                             13

                                           1                    1
                                                                2
                                                      B
                                                                                C
                                       A2      e
                                                                                    
Seating      A
Plane             A1                                                       L

Note: The control dimension is the millimeter column

                          INCHES                          MILLIMETERS

SYMBOL MIN                                     MAX        MIN       MAX

         A            0.039                    0.047      1.00      1.20

         A1           0.002                    0.006      0.05      0.15

         A2           0.037                    0.041      0.95      1.05

         B            0.007                    0.011      0.17      0.27

         C            0.004                    0.008      0.09      0.20

         D            0.346                    0.362      8.80      9.20

         D1           0.272                    0.280      6.90      7.10

         e                0.020 BSC                           0.50 BSC

         L            0.018                    0.030      0.45      0.75

                      0                       7         0            7

                                               45
                                                                                                                 XR16L2750
                                                                       2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                                   REV. 1.0.0

PACKAGE DIMENSIONS (44 PIN PLCC)

              44 LEAD PLASTIC LEADED CHIP CARRIER
                                         (P L C C )

                                                  Rev. 1.00

              D                                                                   C

                                                                                                S eating P lane

              D1                                            4 5 x H2  4 5 x H1                A2

              2 1 44

                                                                                                    B1

    D D1                                                D3                                          B D2
              D3
                                                                                                       e
                                                                                                R

                                                                                       A1
                                                                                  A

          Note: The control dimension is the millimeter column

                      INCHES                                           MILLIMETERS

          SYMBOL MIN              MAX                                  MIN           MAX

          A   0.165               0.180                                4.19          4.57

          A1  0.090               0.120                                2.29          3.05

          A2  0.020               ---                                  0.51                ---

          B   0.013               0.021                                0.33          0.53

          B1  0.026               0.032                                0.66          0.81

          C   0.008               0.013                                0.19          0.32

          D   0.685               0.695                                17.40         17.65

          D1  0.650               0.656                                16.51         16.66

          D2  0.590               0.630                                14.99         16.00

          D3      0.500 typ.                                           12.70 typ.
                                                                       1.27 BSC
          e       0.050 BSC

          H1  0.042               0.056                                1.07          1.42

          H2  0.042               0.048                                1.07          1.22

          R   0.025               0.045                                0.64          1.14

                                  46
XR16L2750                  

                                               2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                                   REV. 1.0.0

REVISION HISTORY

         DATE     REVISION                                               DESCRIPTION
November 2001  Rev P1.0.0
March 2002     Rev P1.1.0   Preliminary data sheet.

September 2002 Rev 1.0.0    Corrected INTA/B pin descriptions and reset state. Clarified MCR bit-3 pin
                            description. Renamed Sclk to Bclk.

                            Release into production. Clarified RTS# pin descriptions, XTAL1 pin description,
                            external clock description, auto RS485 half-duplex control description, EMSR
                            bit-3 description and updated 2.5 V, ICC and ISLEEP DC Electrical Characteristics.

                                                                NOTICE

EXAR Corporation reserves the right to make changes to the products contained in this publication in order
to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of
any circuits described herein, conveys no license under any patent or other right, and makes no
representation that the circuits are free of patent infringement. Charts and schedules contained here in are
only for illustration purposes and may vary depending upon a user's specific application. While the
information in this publication has been carefully checked; no responsibility, however, is assumed for
inaccuracies.
EXAR Corporation does not recommend the use of any of its products in life support applications where
the failure or malfunction of the product can reasonably be expected to cause failure of the life support
system or to significantly affect its safety or effectiveness. Products are not authorized for use in such
applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of
injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR
Corporation is adequately protected under the circumstances.
Copyright 2002 EXAR Corporation
Datasheet September 2002.
Send your UART technical inquiry with technical details to hotline: uarttechsupport@exar.com.
Reproduction, in part or whole, without the prior written consent of EXAR Corporation is prohibited.

                                                                        47
                                                                 XR16L2750

                                      2.25V TO 5.5V DUART WITH 64-BYTE FIFO

                                                                                                            REV. 1.0.0

    TABLE OF CONTENTS

GENERAL DESCRIPTION................................................................................................. 1

     APPLICATIONS............................................................................................................................................. 1
     FEATURES .................................................................................................................................................. 1

    FIGURE 1. XR16L2750 BLOCK DIAGRAM................................................................................................................................................. 1
    FIGURE 2. PIN OUT ASSIGNMENT............................................................................................................................................................. 2

     ORDERING INFORMATION ............................................................................................................................. 2

PIN DESCRIPTIONS ......................................................................................................... 3

1.0 Product DESCRIPTION ........................................................................................................... 6
2.0 FUNCTIONAL DESCRIPTIONS ............................................................................................... 7

     2.1 CPU INTERFACE ................................................................................................................................. 7
     2.2 5-VOLT TOLERANT INPUTS .................................................................................................................. 7
     2.3 DEVICE RESET .................................................................................................................................... 7
     2.4 DEVICE IDENTIFICATION AND REVISION ................................................................................................ 7
     2.5 CHANNEL A AND B SELECTION ............................................................................................................ 7

    FIGURE 3. XR16L2750 DATA BUS INTERCONNECTIONS ........................................................................................................................... 7

     2.6 CHANNEL A AND B INTERNAL REGISTERS ............................................................................................ 8
     2.7 DMA MODE ........................................................................................................................................ 8

    TABLE 1: CHANNEL A AND B SELECT ....................................................................................................................................................... 8
    TABLE 2: TXRDY# AND RXRDY# OUTPUTS IN FIFO AND DMA MODE .................................................................................................... 8

     2.8 INTA AND INTB OUTPUTS .................................................................................................................. 9
     2.9 CRYSTAL OSCILLATOR OR EXTERNAL CLOCK INPUT ............................................................................. 9

    TABLE 3: INTA AND INTB PINS OPERATION FOR TRANSMITTER................................................................................................................ 9
    TABLE 4: INTA AND INTB PIN OPERATION FOR RECEIVER....................................................................................................................... 9
    FIGURE 4. TYPICAL OSCILLATOR CONNECTIONS ........................................................................................................................................ 9

     2.10 PROGRAMMABLE BAUD RATE GENERATOR ....................................................................................... 10

    FIGURE 5. EXTERNAL CLOCK CONNECTION FOR EXTENDED DATA RATE ................................................................................................. 10
    FIGURE 6. BAUD RATE GENERATOR AND PRESCALER ............................................................................................................................ 10

     2.11 TRANSMITTER ................................................................................................................................. 11
            2.11.1 Transmit Holding Register (THR) - Write Only ....................................................................................... 11
            2.11.2 Transmitter Operation in non-FIFO Mode .............................................................................................. 11

    TABLE 5: TYPICAL DATA RATES WITH A 14.7456 MHZ CRYSTAL OR EXTERNAL CLOCK.............................................................................. 11
            2.11.3 Transmitter Operation in FIFO Mode ..................................................................................................... 12

     2.12 RECEIVER ....................................................................................................................................... 12

    FIGURE 7. TRANSMITTER OPERATION IN NON-FIFO MODE...................................................................................................................... 12
    FIGURE 8. TRANSMITTER OPERATION IN FIFO AND FLOW CONTROL MODE............................................................................................. 12

            2.12.1 Receive Holding Register (RHR) - Read-Only ....................................................................................... 13
    FIGURE 9. RECEIVER OPERATION IN NON-FIFO MODE ........................................................................................................................... 13
    FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE............................................................................... 13

     2.13 AUTO RTS (HARDWARE) FLOW CONTROL ....................................................................................... 14
     2.14 AUTO RTS HYSTERESIS ................................................................................................................. 14
     2.15 AUTO CTS FLOW CONTROL ........................................................................................................... 14

    FIGURE 11. AUTO RTS AND CTS FLOW CONTROL OPERATION .............................................................................................................. 15

     2.16 AUTO XON/XOFF (SOFTWARE) FLOW CONTROL ............................................................................... 16
     2.17 SPECIAL CHARACTER DETECT ........................................................................................................ 16
     2.18 AUTO RS485 HALF-DUPLEX CONTROL ........................................................................................... 16

    TABLE 6: AUTO XON/XOFF (SOFTWARE) FLOW CONTROL....................................................................................................................... 16

     2.19 INFRARED MODE ............................................................................................................................. 17
     2.20 SLEEP MODE WITH AUTO WAKE-UP ............................................................................................... 17

    FIGURE 12. INFRARED TRANSMIT DATA ENCODING AND RECEIVE DATA DECODING ................................................................................. 17

     2.21 INTERNAL LOOPBACK ..................................................................................................................... 18

    FIGURE 13. INTERNAL LOOP BACK IN CHANNEL A AND B........................................................................................................................ 18

3.0 UART INTERNAL REGISTERS ............................................................................................. 19

    TABLE 7: UART CHANNEL A AND B UART INTERNAL REGISTERS .............................................................................................. 19
    TABLE 8: INTERNAL REGISTERS DESCRIPTION. SHADED BITS ARE ENABLED WHEN EFR BIT-4=1 ................................................ 20

4.0 INTERNAL Register descriptions ........................................................................................ 21

    I
XR16L2750                                 
2.25V TO 5.5V DUART WITH 64-BYTE FIFO

REV. 1.0.0

     4.1 RECEIVE HOLDING REGISTER (RHR) - READ- ONLY ........................................................................... 21
     4.2 TRANSMIT HOLDING REGISTER (THR) - WRITE-ONLY ......................................................................... 21
     4.3 INTERRUPT ENABLE REGISTER (IER) - READ/WRITE ........................................................................... 21

            4.3.1 IER versus Receive FIFO Interrupt Mode Operation................................................................................ 22
            4.3.2 IER versus Receive/Transmit FIFO Polled Mode Operation .................................................................... 22
     4.4 INTERRUPT STATUS REGISTER (ISR) - READ-ONLY ............................................................................ 23
            4.4.1 Interrupt Generation: ................................................................................................................................ 23
            4.4.2 Interrupt Clearing:..................................................................................................................................... 23
     4.5 FIFO CONTROL REGISTER (FCR) - WRITE-ONLY ............................................................................... 24
    TABLE 9: INTERRUPT SOURCE AND PRIORITY LEVEL ............................................................................................................................... 24
    TABLE 10: TRANSMIT AND RECEIVE FIFO TRIGGER LEVEL SELECTION.................................................................................................... 26
     4.6 LINE CONTROL REGISTER (LCR) - READ/WRITE ................................................................................. 27
     4.7 MODEM CONTROL REGISTER (MCR) OR GENERAL PURPOSE OUTPUTS CONTROL - READ/WRITE ........ 28
    TABLE 11: PARITY SELECTION................................................................................................................................................................ 28
     4.8 LINE STATUS REGISTER (LSR) - READ ONLY ..................................................................................... 29
     4.9 MODEM STATUS REGISTER (MSR) - READ ONLY ............................................................................... 30
     4.10 SCRATCH PAD REGISTER (SPR) - READ/WRITE ............................................................................... 31
     4.11 ENHANCED MODE SELECT REGISTER (EMSR) ................................................................................. 31
    TABLE 12: SCRATCHPAD SWAP SELECTION............................................................................................................................................ 31
     4.12 FIFO LEVEL REGISTER (FLVL) - READ-ONLY ................................................................................... 32
     4.13 BAUD RATE GENERATOR REGISTERS (DLL AND DLM) - READ/WRITE ............................................... 32
     4.14 DEVICE IDENTIFICATION REGISTER (DVID) - READ ONLY .................................................................. 32
    TABLE 13: AUTO RTS HYSTERESIS ....................................................................................................................................................... 32
     4.15 DEVICE REVISION REGISTER (DREV) - READ ONLY ......................................................................... 33
     4.16 TRIGGER LEVEL REGISTER (TRG) - WRITE-ONLY ............................................................................. 33
     4.17 RX/TX FIFO LEVEL COUNT REGISTER (FC) - READ-ONLY ............................................................... 33
     4.18 FEATURE CONTROL REGISTER (FCTR) - READ/WRITE .................................................................... 33
    TABLE 14: TRIGGER TABLE SELECT ....................................................................................................................................................... 33
     4.19 ENHANCED FEATURE REGISTER (EFR) ............................................................................................ 34
    TABLE 15: SOFTWARE FLOW CONTROL FUNCTIONS ............................................................................................................................... 34
            4.19.1 Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write................................... 35
    TABLE 16: UART RESET CONDITIONS FOR CHANNEL A AND B ................................................................................................... 36

ABSOLUTE MAXIMUM RATINGS...................................................................................37
TYPICAL PACKAGE THERMAL RESISTANCE DATA (MARGIN OF ERROR: 15%) 37
ELECTRICAL CHARACTERISTICS ................................................................................37

     DC ELECTRICAL CHARACTERISTICS ...........................................................................................................37

            TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc is 2.25V to 5.5V ....................................... 37

     AC ELECTRICAL CHARACTERISTICS............................................................................................................38

            TA=0o to 70oC (-40o to +85oC for industrial grade package), Vcc is 2.25 to 5.5V............................................ 38
    FIGURE 14. CLOCK TIMING .................................................................................................................................................................... 39
    FIGURE 15. MODEM INPUT/OUTPUT TIMING FOR CHANNELS A & B......................................................................................................... 40
    FIGURE 16. DATA BUS READ TIMING ..................................................................................................................................................... 40
    FIGURE 17. DATA BUS WRITE TIMING .................................................................................................................................................... 41
    FIGURE 18. RECEIVE READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B................................................................. 41
    FIGURE 19. TRANSMIT READY & INTERRUPT TIMING [NON-FIFO MODE] FOR CHANNELS A & B............................................................... 42
    FIGURE 20. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA DISABLED] FOR CHANNELS A & B ............................................... 42
    FIGURE 21. RECEIVE READY & INTERRUPT TIMING [FIFO MODE, DMA ENABLED] FOR CHANNELS A & B ................................................ 43
    FIGURE 22. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE DISABLED] FOR CHANNELS A & B ................................... 43
    FIGURE 23. TRANSMIT READY & INTERRUPT TIMING [FIFO MODE, DMA MODE ENABLED] FOR CHANNELS A & B .................................... 44

     PACKAGE DIMENSIONS (48 PIN TQFP - 7 X 7 X 1 MM)..................................................................................45
     PACKAGE DIMENSIONS (44 PIN PLCC).......................................................................................................46
     REVISION HISTORY ....................................................................................................................................47
TABLE OF CONTENTS ................................................................................................................................. I

                                       II
This datasheet has been downloaded from:
             www.EEworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

XR16L2750CM器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved