XM-C91-2P-UA器件文档内容

XBee-PRO®              XSC       RS-232/RS-485/USB             RF  Modem

Overview

Interfacing            Protocol

Product Manual

For XBee-PRO XSC RF Modem Part Numbers:

XM-C91-2P...   XM-C92-2P...

XM-C91-4P...   XM-C92-4P...

XM-C91-UP...   XM-C92-UP...

900 MHz Stand-alone RF Modems by Digi    International,  Inc.

Digi International

World Headquarters

11001 Bren Road East

Minnetonka, MN 55343

Phone: 952-912-3444 or                                                   90001355_C

877-912-3444                                                             2014.6.3

Fax: 952-912-4952
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

© 2014 Digi International Inc. All rights reserved

No part of the contents of this manual may be transmitted or reproduced in any

form or by any means without the written permission of Digi International Inc.

XBee‐PRO® XSC RF Modem is a trademark of Digi International Inc.

Technical Support:

Phone:                          (866) 765‐9885 toll‐free U.S.A. & Canada

                                (801) 765‐9885 Worldwide

                                8:00 am ‐ 5:00 pm [U.S. Mountain Time]

Online Support:                 http://www.digi.com/support/eservice/login.jsp

Email:                          tech.support@digi.com

© 2014 Digi International Inc.                                                  ii
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

Contents

1. Overview 4

Features Overview                   4

Worldwide Acceptance                   5

Specifications  5

External Interface              6

RF Modem Symbols                    9

2. Interfacing Protocol 10

RS-232 Operation                10

Pin Signals     10

Wiring Diagrams                 11

RS-485 (2-wire) Operation                     12

Pin Signals     13

Wiring Diagram                  13

RS-485 (4-wire) Operation & RS-422 Operation

14

Pin Signals     15

Wiring Diagrams                 15

RS-485/422 Connection Guidelines                  16

USB Operation       17

Pin Signals     17

Appendix A: Agency Certifications 18

FCC (United States) Certification                 18

Labeling Requirements                  18

FCC Notices     18

Limited Modular Approval                   18

FCC-approved Antennas                     19

IC (Industry Canada) Certification                19

Appendix B: Additional Information 23

© 2014 Digi International Inc.                            iii
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

1. Overview

      The XBee-PRO XSC RF Modem is a small, low-power solution that uses the XBee-PRO

      XSC (S3B) 900 MHz RF Module in an enclosure to communicate with systems using

      RS-232, RS-485, and USB interfaces. It allows the user to easily make their existing

      wired systems wireless simply by connecting to this product. The XBee-PRO XSC RF

      Modem is a market replacement of Digi’s 9XStream PKG and is able to fully communi-

      cate with existing 9XStream RF Modems.

      When a system is connected to the XBee-PRO XSC RF Modem, it can transmit and

      receive data from multiple radios on the same wireless network. This is achieved by

      using Digi’s XBee-Pro XSC (S3B) RF Module.

      This manual is not a comprehensive manual where a full description of the XSC RF

      Modem is given. This manual only covers the interfaces needed to communicate with

      the XSC (S3B) 900 MHz RF Module. For an extensive guide on use of the XSC (S3B)

      900 MHz RF Module, see Appendix A of the XBee-PRO 900 HP/XBee-PRO XSC RF

      Modules Product Manual.

1.1.  Features Overview

Long Range Data Integrity                                 Low Power

Range                                                     Receive Current: 60 mA (@9V)

• Indoor/Urban: Up to 2000' (610 m)                       Transmit Current: 140 mA (@9V)

• Outdoor line-of-sight: Up to 9 miles (14                Easy-to-Use

      km)                                                 No configuration required for out-of-the-box RF

Transmit Power: Up to 24 dBm (250 mW)                     data communications.

(software selectable)                                     Free X-CTU Software (Testing and configuration

Receiver Sensitivity: -109 dBm (@10kbps)                  software)

RF Data Rate: Up to 20kbps                                RS-232 and RS-485 variants configurable via the

Advanced Networking & Security                            mini USB port.

True peer-to-peer (no “master” required) com-             Advanced configurations available through stan-

munications                                               dard AT & binary commands.

Point-to-point & point-to-multipoint topologies           Built in RS-232/RS-485/USB interfacing

supported                                                 Small form factor

Retries and Acknowledgements                              Software-selectable serial interface baud rates

7 hopping channels, each with over 65,000 avail-          Support for multiple data formats (parity, start

able network addresses                                    and stop bits, etc.)

FHSS (Frequency Hopping Spread Spectrum)                  Free & Unlimited Technical Support

© 2014 Digi International Inc.                                                                              4
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

1.1.1. Worldwide Acceptance

                                FCC Approved (USA) Refer to Appendix A for FCC Requirements.

                                Systems that include XBee®/XBee-PRO® XSC RF modems inherit Digi Certifications.

                                ISM (Industrial, Scientific & Medical) 900 GHz frequency band

                                Manufactured under ISO 9001:2000 registered standards

                                XBee®/XBee-PRO® XSC (900 MHz) RF Modems are approved for use in US, Canada,

                                and Australia.

1.2. Specifications

                                Table 1‐01.   Specifications     of  the  XBee‐PRO XSC RS‐232/RS‐485/USB RF Modem

                                Specification                             XBee-PRO

                                Performance

                                Indoor/Urban Range                        Up to 2000 ft (610 m)

                                Outdoor line-of-sight Range               Up to 9 miles (14 km) w/ dipole antenna

                                                                          Up to 28 miles (45 km) w/ high-gain antenna

                                Transmit Power Output                     Up to 24 dBm (250 mW) software selectable

                                Throughput Data Rate                      9.6kbps or 19.2kbps

                                RF Data Rate                              10kbps or 20kbps

                                Interface Data Rate                       125 - 65,000 bps (Software selectable, includes non-standard  baud
                                                                          rates)

                                Receiver Sensitivity                      -109dBm at 10kbps; -107dBm at 20kbps

                                Networking & Security

                                Frequency                                 902-928MHz (located in the 900MHz ISM Band)

                                Spread Spectrum                           Frequency Hopping

                                Supported Network Topologies              Point-to-point, Point-to-Multipoint, Peer-to-Peer

                                Channel Capacity                          7 hop sequences share 25 frequencies

                                Antenna

                                Connector                                 RPSMA (reverse polarity SMA)

                                Impedance                                 50 ohms unbalanced

                                Power Requirements

                                Power Supply                              7-30 VDC

                                Receive Current                           60 mA (@9V)

                                Transmit Current                          140 mA (@9V)

                                Physical Properties

                                Size                                      4.500” x 2.750” x 1.125” (11.4cm x 7.0cm x 2.9cm)

                                Weight                                    5.25 oz. (150 g)

                                Data Connection                           Female DB-9, RS-485/422 screw terminal, USB Type B, USB       Mini-B

                                Operating Temperature                     -40 - 85º C (Industrial)

                                Certifications (partial list)

                                United States (FCC Part 15.247)           MCQ-XB900HP

                                Industry Canada (IC)                      1846A-XB900HP

                                Australia                                 C-Tick

                                RoHS                                      Compliant

                                * See Appendix A for region‐specific certification requirements.

© 2014 Digi International Inc.                                                                                                                  5
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

1.3. External Interface

Figure 1‐01.  Front View (RS232)  1-01a. Serial Port

                                  Standard female DB-9

                                  1-01b. Power Connector

                                  7-30 VDC power connector, barrel type 2.1/5mm, center positive.

                                  1-01c. Reset Button

                                  The Reset Switch is used to reset (re-boot) the XBee-PRO XSC RF

                                  Modem. This switch only applies when using the configuration tabs    of

                                  Digi's X-CTU Software.

Figure 1‐02.  Back View (RS232)   1-02a. RSSI LEDs

                                  Not applicable to XBee-PRO XSC RF Modem.

                                  1-02b. I/O & Power LEDs

                                  LEDs indicate RF modem activity as follows:

                                  Yellow (top LED) = Serial Data Out (to host)

                                  Green (middle) = Serial Data In (from host)

                                  Red (bottom) = Power/TX Indicator (Red light is on when powered,

                                  off briefly during RF transmission)

                                  1-02c. Commissioning Push Button

                                  Not applicable to XBee-PRO XSC RF Modem.

                                  1-02d. USB Mini-B Port

                                  When USB mini is plugged in, all RS232 communications to and from

                                  the XBee are disabled. The USB is to serve as a configuration port.

                                  The XBee should not transmit when USB is plugged in.

                                  1-02e. Antenna Port

                                  Port is a 50Ω RF signal connector for connecting to an external

                                  antenna. The connector type is RPSMA (Reverse Polarity SMA)

                                  female. The connector has threads on the outside of a barrel and a

                                  male center conductor.

© 2014 Digi International Inc.                                                                     6
XBee‐PRO®     XSC RS‐232/RS‐485/USB  RF  Modem‐  Product Manual

Figure 1‐03.  Front View (RS485)                 1-03a. Serial Port

                                                 Phoenix 6- pin connector

                                                 1-03b. Power Connector

                                                 7-30 VDC power connector, barrel type 2.1/5mm, center positive.

                                                 1-03c. DIP Switch

                                                 120 ohms termination for the receiving differential pairs if switch is in

                                                 the up Position. Switch 1 is for half duplex (2 wire) termination.

                                                 Switch 2 is for full duplex (4 wire) termination.

                                                 1-03d. Reset Button

                                                 The Reset Switch is used to reset (re-boot) the XBee-PRO XSC RF

                                                 Modem. This switch only applies when using the configuration tabs of

                                                 Digi’s X-CTU Software.

Figure 1‐04.  Back View (RS485)                  1-04a. RSSI LEDs

                                                 Not applicable to XBee-PRO XSC RF Modem.

                                                 1-04b. I/O & Power LEDs

                                                 LEDs indicate RF modem activity as follows:

                                                 Yellow (top LED) = Serial Data Out (to host)

                                                 Green (middle) = Serial Data In (from host)

                                                 Red (bottom) = Power/TX Indicator (Red light is on when powered,

                                                 off briefly during RF transmission)

                                                 1-04c. Commissioning Push Button

                                                 Not applicable to XBee-PRO XSC RF Modem.

                                                 1-04d. USB Mini-B Port

                                                 When USB mini is plugged in, all RS485 communications to and from

                                                 the XBee are disabled. The USB is to serve as a configuration port.

                                                 The XBee should not transmit if USB is plugged in.

                                                 1-04e. Antenna Port

                                                 Port is a 50Ω RF signal connector for connecting to an external

                                                 antenna. The connector type is RPSMA (Reverse Polarity SMA)

                                                 female. The connector has threads on the outside of a barrel and a

                                                 male center conductor.

© 2014 Digi International Inc.                                                                                       7
XBee‐PRO®     XSC RS‐232/RS‐485/USB  RF  Modem‐  Product Manual

Figure 1‐05.  Front View (USB)                   1-05a. USB Port

                                                 Type B USB port

                                                 1-05b. Power Connector

                                                 7-30 VDC power connector, barrel type 2.1/5mm, center positive.

                                                 1-05c. Reset Button

                                                 The Reset Switch is used to reset (re-boot) the XBee-PRO XSC RF

                                                 Modem. This switch only applies when using the configuration tabs   of

                                                 Digi's X-CTU Software.

Figure 1‐06.  Back View (USB)                    1-06a. RSSI LEDs

                                                 Not applicable to XBee-PRO XSC RF Modem.

                                                 1-06b. I/O & Power LEDs

                                                 LEDs indicate RF modem activity as follows:

                                                 Yellow (top LED) = Serial Data Out (to host)

                                                 Green (middle) = Serial Data In (from host)

                                                 Red (bottom) = Power/TX Indicator (Red light is on when powered,

                                                 off briefly during RF transmission)

                                                 1-06c. Commissioning Push Button

                                                 Not applicable to XBee-PRO XSC RF Modem.

                                                 1-06d. Antenna Port

                                                 Port is a 50Ω RF signal connector for connecting to an external

                                                 antenna. The connector type is RPSMA (Reverse Polarity SMA)

                                                 female. The connector has threads on the outside of a barrel and a

                                                 male center conductor

© 2014 Digi International Inc.                                                                                    8
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

1.4. RF Modem Symbols

                                The following symbols are found on top  of  the  RF  Modem.  The  description  of  the  symbol  is  next to

                                the symbol.

© 2014 Digi International Inc.                                                                                                      9
   XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

   2. Interfacing Protocol

                     The XBee-PRO XSC RS-232/485/USB RF Modem      supports  the             following    interfacing  protocols:

                                    • RS-232

                                    • RS-485 (2-wire) Half-duplex

                                    • RS-485 (4-wire) and RS-422

                                    • USB

               2.1.  RS-232 Operation

                     2.1.1. Pin Signals

                                    Figure 2‐01.  Pins used on the female RS‐232 (DB‐9) Serial Connector

                                    Table 2‐01.   RS‐232 Pin Assignments and Implementation

                                    DB-9 Pin      RS-232 Name      Description                            Implementation*

                                    1             DCD              Data-Carrier-Detect                    Connected to DSR (pin6)

                                    2             RXD              Received Data                          Serial data exiting the RF modem
                                                                                                                       (to host)

                                    3             TXD              Transmitted Data                       Serial data entering into the RF modem
                                                                                                                       (from host)

                                    4             DTR              Data-Terminal-Ready                    By default, this pin is not used. To configure this pin
                                                                                                          to support Sleep Mode, refer to the Sleep Mode, SM
                                                                                                          Command and PW Command Sections.

                                    5             GND              Ground Signal                                       Ground

                                    6             DSR              Data-Set-Ready                         Connected to DCD (pin1)

                                                                                                          RTS(request-to-send) flow control – By default, this
                                                                                                          pin is not used. To configure this pin to regulate the
                                                                                                          flow of serial data exiting the modem, refer to the
                                                                                                          Serial Communications and
                                    7             RTS / CMD        Request-to-Send /

                                                                   Command Mode                           RT Command section

                                                                                                          CMD – Refer to Binary Commands and RT
                                                                                                          Command Sections to enable binary command
                                                                                                                       programming

                                                                                                          CTS (clear-to-send) flow control –When pin is driven
                                                                                                          low, UART host is permitted to send serial data to
                                    8             CTS              Clear-to-Send                          the modem. Refer to the Serial communications and

                                                                                                          CS Command sections for more information

                                    9             RI               Ring Indicator                         Optional power input (protection circuitry to prevent
                                                                                                          back flow from other power sources internal to the
                                                                                                                       board)

©  2014  Digi  International  Inc.                                                                                                                                 10
XBee‐PRO®  XSC  RS‐232/RS‐485/USB RF Modem‐ Product Manual

                2.1.2. Wiring Diagrams

                                Figure 2‐02.  RS‐232 Device DTE Device (male DB‐9 connector)  wired to a  DCE  RF modem (female DB‐9)

                                              XBee‐PRORF Modem

                DCE RF Modem to an DCE RS-232 Device

                                Figure 2‐03.  DCE RF Modem (female DB‐9 connector) wired to   an RS‐232   DCE  Device (male DB‐9)XBee‐

                                              PRORF Modem

© 2014 Digi International Inc.                                                                                                          11
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

      Sample Wireless Connection: DTE <--> DCE                                      DCE <--> DCE

                                Figure 2‐04.  Typical wireless link between DTE and DCE devices

2.2.  RS-485 (2-wire) Operation

                                Note that with the RS-485 variant of the XSC RF Modem, the RF Modem is defaulted with the CS

                                command (AT parameter) to 3. This parameter controls the TX enable signal and allows the

                                modem to output any data in the DO buffer to the host device for the RS-485 interface. In the

                                event that the parameter is accidentally changed, which would result in RS-485 communication

                                being halted, a USB mini cable should be plugged into the modem to reconfigure it. The

                                reconfiguration can be done by using Digi’s X-CTU.

                                With the USB plugged in, open X-CTU and select the Com port of the USB.  Select the Terminal tab

                                and type '+++'. The system will respond with 'OK'.  Type 'ATCS3' then , and the system

                                will respond with 'OK'.  Type 'ATWR' then , and the system will respond with 'OK'.             Type

                                'ATCN' then to exit command mode, and the system will respond with 'OK'.        Unplug the

                                USB and return to the existing RS-485 interface.    The XSC RF Modem is now ready to

                                communicate in RS-485 mode.

                                NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the ‘Baud’

                                setting on the “PC Settings” tab matches the BD (Interface Data Rate) setting of the RF modem (by default, BD

                                parameter = 3, which is associated to 9600 baud).

© 2014 Digi International Inc.                                                                                                                 12
XBee‐PRO®  XSC  RS‐232/RS‐485/USB RF Modem‐ Product Manual

                2.2.1. Pin Signals

                                Figure 2‐05.  Pins used on the RS‐485 (2 wire) Phoenix 6 Pin Connector

                                Table 2‐02.   Pins used on the RS‐485 (2 wire) Phoenix 6 Pin Connector

                                Phoenix 6     RS-485 Name   Description                                 Implementation*

                                Pin

                                1             TX/ RX+       Negative Data Line                          Transmit serial data to and from the RF modem

                                2             TX/ RX-       Positive Data Line                          Transmit serial to and from the RF modem

                                5             GND           Ground Signal                               Ground

                                6             PWR           Power Signal                             Optional power input (protection circuitry to prevent
                                                                                                     back flow from other power sources internal to the
                                                                                                        board)

                                3, 4                                                       Not Used

                2.2.2. Wiring                 Diagram

                                Figure 2‐06.  RF Modem in an RS‐ 485 (2‐wire) half duplex

© 2014 Digi International Inc.                                                                                                                              13
   XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

               2.3. RS-485 (4-wire) Operation & RS-422 Operation

                                    Note that with the RS-485 variant of the XSC RF Modem, the RF Modem is defaulted with the CS

                                    command (AT parameter) to 3.  This parameter controls the TX enable signal and allows the

                                    modem to output any data in the DO buffer to the host device for the RS-485/422 interface. In the

                                    event that the parameter is accidentally changed, which would result in RS-485 communication

                                    being halted,  a USB mini cable should be plugged into the modem to reconfigure it. The

                                    reconfiguration can be done by using Digi's X-CTU.

                                    With the USB plugged in, open X-CTU and select the Com port of the USB.            Select the Terminal tab

                                    and type '+++'. The system will respond with 'OK'.    Type 'ATCS3' then , and the system

                                    will respond with 'OK'.  Type 'ATWR' then , and the system will respond with 'OK'.     Type

                                    'ATCN' then to exit command mode, and the system will respond with 'OK'.         Unplug the

                                    USB and return to the existing RS-485/422 interface.  The XSC RF Modem is now ready to

                                    communicate in RS-485 mode.

                                    NOTE: Failure to enter AT Command Mode is most commonly due to baud rate           mismatch. Ensure the ʹBaudʹ  set‐

                                    ting on the ʺPC Settingsʺ tab matches the BD (Interface Data Rate) setting of the  RF modem (by default, BD

                                    parameter = 3, which is associated to 9600 baud).

©  2014  Digi  International  Inc.                                                                                                                  14
XBee‐PRO®  XSC  RS‐232/RS‐485/USB RF Modem‐ Product Manual

                2.3.1. Pin Signals

                                Figure 2‐07.  Pins used on the RS‐485 (4‐wire) Phoenix 6 Pin Connector

                                Table 2‐03.   RS‐485 (4‐wire) 6‐pin Connector Pin Assignments and Implementation

                                Phoenix 6     RS-485 Name   Description                                 Implementation*

                                Pin

                                1             TX+           Transmit Positive                           Serial data sent from RF modem

                                2             TX-           Transmit Negative Data Line                 Serial data received by the RF modem

                                3             RX+           Receive Positive Data Line                  Serial data received the RF modem

                                4             RX-           Receive Negative Data Line                  Serial data received by the RF modem

                                5             GND           Ground Signal                                         Ground

                                6             PWR           Power Signal                      Optional power input (protection circuitry to prevent
                                                                                              back flow from other power sources internal to the
                                                                                                                  board)

                2.3.2. Wiring                 Diagrams

                                Figure 2‐08.  XSC RF Modem in an RS‐485 (4‐wire) environment

© 2014 Digi International Inc.                                                                                                                       15
XBee‐PRO®  XSC  RS‐232/RS‐485/USB RF Modem‐ Product Manual

                                Figure 2‐09.  XSC RF Modem in an RS‐422 environment

                2.3.3. RS-485/422 Connection Guidelines

                                The RS-485/422 protocol provides a solution for wired communications that can tolerate high

                                noise and push signals over long cable lengths. RS-485/422 signals can communicate as far as

                                4000 feet (1200 m). RS-232 signals are suitable for cable distances up to 100 feet (30.5 m).

                                RS-485 offers multi-drop capability in which up to 32 nodes can be connected. The RS-422

                                protocol is used for point-to-point communications.

                                Suggestions for integrating the XSC RF Modem with the RS-485/422 protocol:

                                Twisted pair cabling should be used for the positive and negative data lines. An Ethernet cable is

                                good for twisted pairs. When using Ethernet twisted pair cabling: Select wires so that TX+ and TX-

                                are connected to a twisted pair. Likewise, select wires so that RX+ and RX- are connected to a

                                twisted pair. (For example, tie the green and white/green wires to TX+ and TX-). This reduces the

                                amount of noise on the data line.

© 2014 Digi International Inc.                                                                                                      16
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

2.4. USB Operation

                                Note that when a Mini-USB cable is plugged into the XSC RF Modem, communication to and from

                                the RS-232 interface and the RS-485/422 is halted. USB communications take precedence over all

                                other interfaces when plugged in. To restore communication with other interfaces, the USB cable

                                should be unplugged.

                                **The Mini-B USB Connector is intended as a configuration port. The RF Modem should not

                                transmit data when the Mini USB cable is connected.

2.4.1. Pin Signals

                                Figure 2‐010.Pins used on the Type B USB Connector

                                Table 2‐04.    Type B USB Connector Pin Assignments and Implementation

                                Pin            Name         Description                                 Implementation*

                                1                     VBUS  Power                                       Power the RF modem

                                2                     D-    Negative Data Line           Transmit       data to and from the RF  modem

                                3                     D+    Positive Data Line           Transmit       data to and from the RF  modem

                                4                     GND   Ground Signal                               Ground

                                Figure 2‐011.  Pins used on the Mini‐B USB Connector

                                Table 2‐05.    Mini‐B USB Connector Pin Assignments and Implementation

                                Pin            Name         Description                                 Implementation*

                                1                     VBUS  Power                                       Power the RF modem

                                2                     D-    Negative Data Line           Transmit       data to and from the RF  modem

                                3                     D+    Positive Data Line           Transmit       data to and from the RF  modem

                                4                     ID    Permits distinction of host
                                                            connection from slave                       Not connected
                                                            connection

                                5                     GND   Ground Signal                               Ground

© 2014 Digi International Inc.                                                                                                          17
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

Appendix A: Agency Certifications

FCC  (United States) Certification

                                The XBee-PRO® XSC RF Modem complies with Part 15 of the FCC rules and regulations.

                                Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required.

                                RF Modems/integrators must comply with the following regulations:

                                1.  The system integrator must ensure that the text provided with this device [Figure A-01] is

                                    placed on the outside of the final product and within the final product operation manual.

                                2.  The XBee-PRO® XSC RF Modem may only be used with antennas that have been tested

                                    and approved for use with this modem (refer to Table A-01).

     Labeling Requirements

                                           WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling

                                           requirements are met. This includes a clearly visible label on the outside of the final

                                           product enclosure that displays the text shown in the figure below.

                                Figure A‐01. Required FCC Label for OEM products containing the XBee‐PRO® XSC RF Modem.

                                Contains FCC ID: MCQ-XB900HP

                                The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two

                                conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any inter-

                                ference received, including interference that may cause undesired operation.

     FCC Notices

                                IMPORTANT: The XBee-PRO® XSC RS-232/RS-485/USB RF Module has been certified by the FCC

                                for use with other products without any further certification (as per FCC section 2.1091).

                                Modifications not expressly approved by Digi could void the user's authority to operate the

                                equipment.

                                IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section

                                15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.

                                IMPORTANT: The RF Module has been certified for remote and base radio applications. If the

                                module will be used for portable applications, the device must undergo SAR testing.

                                This equipment has been tested and found to comply with the limits for a Class B digital device,

                                pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

                                against harmful interference in a residential installation. This equipment generates, uses and can

                                radiate radio frequency energy and, if not installed and used in accordance with the instructions,

                                may cause harmful interference to radio communications. However, there is no guarantee that

                                interference will not occur in a particular installation.

                                If this equipment does cause harmful interference to radio or television reception, which can be

                                determined by turning the equipment off and on, the user is encouraged to try to correct the

                                interference by one or more of the following measures: Re-orient or relocate the receiving

                                antenna, Increase the separation between the equipment and receiver, Connect equipment and

                                receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician

                                for help.

     Limited Modular Approval

                                This modem contains an RF module approved for Limited Modular use operating as a mobile

                                transmitting device with respect to section 2.1091 and is limited to OEM installation for Mobile and

                                Fixed applications only. During final installation, end-users are prohibited from access to any

© 2014 Digi International Inc.                                                                                                                18
XBee‐PRO®  XSC  RS‐232/RS‐485/USB RF Modem‐ Product Manual

                                programming parameters. Professional installation adjustment is required for setting module

                                power and antenna gain to meet EIRP compliance for high gain antenna(s).

                                Final antenna installation and operating configurations of this transmitter including antenna gain

                                and cable loss must not exceed the EIRP of the configuration used for calculating MPE. Grantee

                                (Digi) must coordinate with OEM integrators to ensure the end-users and installers of products

                                operating with the modem are provided with operating instructions to satisfy RF exposure

                                requirements.

                                The FCC grant is valid only when the device is sold to OEM integrators. Integrators are instructed

                                to ensure the end-user has no manual instructions to remove, adjust or install the device.

                FCC-approved Antennas

                                         WARNING: This device has been tested with Reverse Polarity SMA connectors with the

                                         antennas listed in the tables of this section. When integrated into OEM products, fixed

                                         antennas require installation preventing end-users from replacing them with non-

                                         approved antennas. Antennas not listed in the tables must be tested to comply with FCC

                                         Section 15.203 (unique antenna connectors) and Section 15.247 (emissions).

                Fixed Base Station and Mobile Applications

                                Digi RF modules are pre-FCC approved for use in fixed base station and mobile applications. When

                                the antenna is mounted at least 20cm (8") from nearby persons, the application is considered a

                                mobile application.

                Portable Applications and SAR Testing

                                If the module will be used at distances closer than 20cm to all persons, the device may be

                                required to undergo SAR testing. Co-location with other transmitting antennas closer than 20cm

                                should be avoided.

                RF Exposure

                                This statement must be included as a CAUTION statement in OEM product manuals.

                                         WARNING: This equipment is approved only for mobile and base station transmitting

                                         devices. Antenna(s) used for this transmitter must be installed to provide a separation

                                         distance of at least 20 cm from all persons and must not be co-located or operating in

                                         conjunction with any other antenna or transmitter.

IC (Industry Canada) Certification

                                This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject

                                to the following two conditions: (1) this device may not cause interference, and (2) this device

                                must accept any interference, including interference that may cause undesired operation of the

                                device.

                                Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio

                                exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne

                                doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage

                                radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement

                                Labeling Requirements

                                Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label

                                on the outside of the final product enclosure must display one of the following text:

                                Contains IC: 1846A-XB900HP

                                The integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B-

                                Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts

                                FCC test report or CISPR 22 test report for compliance with ICES-003.

© 2014 Digi International Inc.                                                                                                      19
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

                           Antenna Options: 900 MHz Antenna Listings

                                The antennas in the tables below have been approved for use with this product. Digi does not

                                carry all of these antenna variants. Contact Digi Sales for available antennas.

                                              Table A-01. Antennas approved for use with the XBee-PRO XSC RF Modem

                                                                                                                 Cable Loss or

Part Number                     Type                Connector         Gain     Application                       Power Reduction

                                                                                                                 for S3B Radio

Omni-directional antennas

A09-F0                          Fiberglass Base     RPN               0 dBi    Fixed                             0dB

A09-F1                          Fiberglass Base     RPN               1.0 dBi  Fixed                             0dB

A09-F2                          Fiberglass Base     RPN               2.1 dBi  Fixed                             0dB

A09-F3                          Fiberglass Base     RPN               3.1 dBi  Fixed                             0dB

A09-F4                          Fiberglass Base     RPN               4.1 dBi  Fixed                             0dB

A09-F5                          Fiberglass Base     RPN               5.1 dBi  Fixed                             0dB

A09-F6                          Fiberglass Base     RPN               6.1 dBi  Fixed                             0dB

A09-F7                          Fiberglass Base     RPN               7.1 dBi  Fixed                             0dB

A09-F8                          Fiberglass Base     RPN               8.1 dBi  Fixed                             0dB

A09-F9                          Base Station        RPSMAF            9.2dBi   Fixed                             0dB

A09-W7                          Wire Base Station   RPN               7.1 dBi  Fixed                             0dB

A09-F0                          Fiberglass Base     RPSMA             0 dBi    Fixed                             0dB

A09-F1                          Fiberglass Base     RPSMA             1.0 dBi  Fixed                             0dB

A09-F2                          Fiberglass Base     RPSMA             2.1 dBi  Fixed                             0dB

A09-F3                          Fiberglass Base     RPSMA             3.1 dBi  Fixed                             0dB

A09-F4                          Fiberglass Base     RPSMA             4.1 dBi  Fixed                             0dB

A09-F5                          Fiberglass Base     RPSMA             5.1 dBi  Fixed                             0dB

A09-F6                          Fiberglass Base     RPSMA             6.1 dBi  Fixed                             0dB

A09-F7                          Fiberglass Base     RPSMA             7.1 dBi  Fixed                             0dB

A09-F8                          Fiberglass Base     RPSMA             8.1 dBi  Fixed                             0dB

A09-M7                          Base Station        RPSMAF            7.2dBi   Fixed                             0dB

A09-W7SM                        Wire Base Station   RPSMA             7.1 dBi  Fixed                             0dB

A09-F0TM                        Fiberglass Base     RPTNC             0 dBi    Fixed                             0dB

A09-F1TM                        Fiberglass Base     RPTNC             1.0 dBi  Fixed                             0dB

A09-F2TM                        Fiberglass Base     RPTNC             2.1 dBi  Fixed                             0dB

A09-F3TM                        Fiberglass Base     RPTNC             3.1 dBi  Fixed                             0dB

A09-F4TM                        Fiberglass Base     RPTNC             4.1 dBi  Fixed                             0dB

A09-F5TM                        Fiberglass Base     RPTNC             5.1 dBi  Fixed                             0dB

A09-F6TM                        Fiberglass Base     RPTNC             6.1 dBi  Fixed                             0dB

A09-F7TM                        Fiberglass Base     RPTNC             7.1 dBi  Fixed                             0dB

A09-F8TM                        Fiberglass Base     RPTNC             8.1 dBi  Fixed                             0dB

A09-W7TM                        Wire Base Station   RPTNC             7.1 dBi  Fixed                             0dB

A09-HSM-7                       Straight half-wave  RPSMA             3.0 dBi  Fixed / Mobile                    0dB

A09-HASM-675                    Articulated half-   RPSMA             2.1 dBi  Fixed / Mobile                    0dB

A09-HABMM-P6I                   Articulated half-   MMCX              2.1 dBi  Fixed / Mobile                    0dB

A09-HABMM-6-P6I                 Articulated half-   MMCX              2.1 dBi  Fixed / Mobile                    0dB

A09-HBMM-P6I                    Straight half-wave  MMCX              2.1 dBi  Fixed / Mobile                    0dB

A09-HRSM                        Right angle half-   RPSMA             2.1 dBi  Fixed                             0dB

A09-HASM-7                      Articulated half-   RPSMA             2.1 dBi  Fixed                             0dB

© 2014 Digi International Inc.                                                                                                    20
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

A09-HG                          Glass mounted         RPSMA       2.1 dBi   Fixed           0dB

A09-HATM                        Articulated half-     RPTNC       2.1 dBi   Fixed           0dB

A09-H                           Half-wave dipole      RPSMA       2.1 dBi   Fixed           0dB

A09-HBMMP6I                     1/2 wave antenna      MMCX        2.1dBi    Mobile          0dB

A09-QBMMP6I                     1/4 wave antenna      MMCX        1.9 dBi   Mobile          0dB

A09-QI                          1/4 wave integrated   Integrated  1.9 dBi   Mobile          0dB
                                wire antenna

29000187                        Helical               Integrated  -2.0 dBi  Fixed/Mobile    0dB

A09-QW                          Quarter-wave wire     Permanent   1.9 dBi   Fixed / Mobile  0dB

A09-QRAMM                       3 “Quarter-wave       MMCX        2.1 dBi   Fixed / Mobile  0dB

A09-QSM-3                       Quarter-wave          RPSMA       1.9 dBi   Fixed / Mobile  0dB

A09-QSM-3H                      Heavy duty quarter-   RPSMA       1.9 dBi   Fixed / Mobile  0dB

A09-QBMM-P6I                    Quarter-wave w/ 6”    MMCX        1.9 dBi   Fixed / Mobile  0dB

A09-QHRN                        Miniature Helical     Permanent   -1 dBi    Fixed / Mobile  0dB

A09-QHSN                        Miniature Helical     Permanent   -1 dBi    Fixed / Mobile  0dB

A09-QHSM-2                      2” Straight           RPSMA       1.9 dBi   Fixed / Mobile  0dB

A09-QHRSM-2                     2" Right angle        RPSMA       1.9 dBi   Fixed / Mobile  0dB

A09-QHRSM-170                   1.7" Right angle      RPSMA       1.9 dBi   Fixed / Mobile  0dB

A09-QRSM-380                    3.8" Right angle      RPSMA       1.9 dBi   Fixed / Mobile  0dB

A09-QAPM-520                    5.2” Articulated      Permanent   1.9 dBi   Fixed / Mobile  0dB

A09-QSPM-3                      3” Straight screw     Permanent   1.9 dBi   Fixed / Mobile  0dB

A09-QAPM-3                      3” Articulated screw  Permanent   1.9 dBi   Fixed / Mobile  0dB

A09-QAPM-3H                     3” Articulated screw  Permanent   1.9 dBi   Fixed / Mobile  0dB

A09-DPSM-P12F                   omni directional      RPSMA       3.0 dBi   Fixed           0dB

A09-D3NF-P12F                   omni directional      RPN         3.0 dBi   Fixed           0dB

A09-D3SM-P12F                   omni directional w/   RPSMA       3.0 dBi   Fixed           0dB

A09-D3PNF                       omni directional      RPN         3.0 dBi   Fixed           0dB

A09-D3TM-P12F                   omni directional w/   RPTNC       3.0 dBi   Fixed           0dB

A09-D3PTM                       omni directional      RPTNC       3.0 dBi   Fixed           0dB

A09-M0SM                        Mag Mount             RPSMA       0 dBi     Fixed           0dB

A09-M2SM                        Mag Mount             RPSMA       2.1 dBi   Fixed           0dB

A09-M3SM                        Mag Mount             RPSMA       3.1 dBi   Fixed           0dB

A09-M5SM                        Mag Mount             RPSMA       5.1 dBi   Fixed           0dB

A09-M7SM                        Mag Mount             RPSMA       7.1 dBi   Fixed           0dB

A09-M8SM                        Mag Mount             RPSMA       8.1 dBi   Fixed           0dB

A09-M0TM                        Mag Mount             RPTNC       0 dBi     Fixed           0dB

A09-M2TM                        Mag Mount             RPTNC       2.1 dBi   Fixed           0dB

A09-M3TM                        Mag Mount             RPTNC       3.1 dBi   Fixed           0dB

A09-M5TM                        Mag Mount             RPTNC       5.1 dBi   Fixed           0dB

A09-M7TM                        Mag Mount             RPTNC       7.1 dBi   Fixed           0dB

A09-M8TM                        Mag Mount             RPTNC       8.1 dBi   Fixed           0dB

Yagi antennas

A09-Y6                          2 Element Yagi        RPN         6.1 dBi   Fixed / Mobile  0dB

A09-Y7                          3 Element Yagi        RPN         7.1 dBi   Fixed / Mobile  0dB

A09-Y8                          4 Element Yagi        RPN         8.1 dBi   Fixed / Mobile  0dB

A09-Y9                          4 Element Yagi        RPN         9.1 dBi   Fixed / Mobile  0dB

A09-Y10                         5 Element Yagi        RPN         10.1 dBi  Fixed / Mobile  0dB

A09-Y11                         6 Element Yagi        RPN         11.1 dBi  Fixed / Mobile  0dB

© 2014 Digi International Inc.                                                                   21
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

A09-Y12                         7 Element Yagi                 RPN     12.1 dBi  Fixed / Mobile                         0dB

A09-Y13                         9 Element Yagi                 RPN     13.1 dBi  Fixed / Mobile                         0.8dB

A09-Y14                         10 Element Yagi                RPN     14.1 dBi  Fixed / Mobile                         1.8dB

A09-Y14                         12 Element Yagi                RPN     14.1 dBi  Fixed / Mobile                         1.8dB

A09-Y15                         13 Element Yagi                RPN     15.1 dBi  Fixed / Mobile                         2.8dB

A09-Y15                         15 Element Yagi                RPN     15.1 dBi  Fixed / Mobile                         2.8dB

A09-Y6TM                        2 Element Yagi                 RPTNC   6.1 dBi   Fixed / Mobile                         0dB

A09-Y7TM                        3 Element Yagi                 RPTNC   7.1 dBi   Fixed / Mobile                         0dB

A09-Y8TM                        4 Element Yagi                 RPTNC   8.1 dBi   Fixed / Mobile                         0dB

A09-Y9TM                        4 Element Yagi                 RPTNC   9.1 dBi   Fixed / Mobile                         0dB

A09-Y10TM                       5 Element Yagi                 RPTNC   10.1 dBi  Fixed / Mobile                         0dB

A09-Y11TM                       6 Element Yagi                 RPTNC   11.1 dBi  Fixed / Mobile                         0dB

A09-Y12TM                       7 Element Yagi                 RPTNC   12.1 dBi  Fixed / Mobile                         0dB

A09-Y13TM                       9 Element Yagi                 RPTNC   13.1 dBi  Fixed / Mobile                         0.8dB

A09-Y14TM                       10 Element Yagi                RPTNC   14.1 dBi  Fixed / Mobile                         1.8dB

A09-Y14TM                       12 Element Yagi                RPTNC   14.1 dBi  Fixed / Mobile                         1.8dB

A09-Y15TM                       13 Element Yagi                RPTNC   15.1 dBi  Fixed / Mobile                         2.8dB

A09-Y15TM                       15 Element Yagi                RPTNC   15.1 dBi  Fixed / Mobile                         2.8dB

                                Transmitters with Detachable Antennas

                                This radio transmitter (IC: 1846A-XB900HP) has been approved by Industry Canada to operate

                                with the antenna types listed in the table above with the maximum permissible gain and required

                                antenna impedance for each antenna type indicated. Antenna types not included in this list, having

                                a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with

                                this device.

                                Le présent émetteur radio (IC: 1846A-XB900HP) a été approuvé par Industrie Canada pour

                                fonctionner avec les types d'antenne énumérés ci?dessous et ayant un gain admissible maximal et

                                l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste,

                                ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour

                                l'exploitation de l'émetteur.

                                Detachable Antenna

                                Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a

                                type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce

                                potential radio interference to other users, the antenna type and its gain should be so chosen that

                                the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful

                                communication.

                                Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner

                                avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par

                                Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des

                                autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope

                                rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire àl'établissement d'une

                                communication satisfaisante.

© 2014 Digi International Inc.                                                                                                         22
XBee‐PRO® XSC RS‐232/RS‐485/USB RF Modem‐ Product Manual

Appendix B: Additional Information

5-Year Warranty

                                XBee RF Modems from Digi International, Inc. (the “Product”) are warranted against defects in

                                materials and workmanship under normal use, for a period of 5 years from the date of pur-

                                chase. In the event of a product failure due to materials or workmanship, Digi will repair or

                                replace the defective product. For warranty service, return the defective product to Digi Inter-

                                national, shipping prepaid, for prompt repair or replacement.

                                The foregoing sets forth the full extent of Digi International's warranties regarding the Product.

                                Repair or replacement at Digi International's option is the exclusive remedy. THIS WARRANTY

                                IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DIGI SPECIFICALLY

                                DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR-

                                POSE. IN NO EVENT SHALL DIGI, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN

                                EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME,

                                INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL,

                                SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE

                                PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT

                                ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES.

                                THEREFORE, THE FOREGOING EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty pro-

                                vides specific legal rights. Other rights which vary from state to state may also apply.

Contact Digi International

                                Free and unlimited technical support is included with every Digi Radio Modem sold.  For   the  best  in

                                wireless data solutions and support, please use the following resources:

                                Documentation:      http://www.digi.com/support/

                                Technical Support:  Phone. 952-912-3444 U.S.A. & Canada

                                                    877-912-3444 Worldwide

                                Live Chat.          http://www.digi.com/contactus/

                                E-Mail.             http://www.digi.com/support/eservice/eservicelogin.jsp

© 2014 Digi International Inc.                                                                                                      23
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Digi International:

XM-C91-UP-UA  XM-C91-2P-UA

小广播

XM-C91-2P-UA器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved