电子工程世界电子工程世界电子工程世界

产品描述

搜索
 

XCDN0000

器件型号:XCDN0000
器件类别:热门应用    测试测量   
厂商名称:Red Lion Controls, Inc.
厂商官网:http://www.redlion.net/
标准:  
下载文档

器件描述

dsp/MC devicenet option card

参数
Datasheets:
XCDN Model:
Standard Package : 1
Category: Industrial Controls, Meters
Family: Accessories
Series: *

XCDN0000器件文档内容

                                                                                                                     Bulletin No. XCDN-A
                                                                                                                     Drawing No. LP0668
                                                                                                                     Released 01/10

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

MODEL XCDN - DeviceNet OPTION CARD FOR DATA STATION PLUS AND
                                                              MODULAR CONTROLLER

                                                                                        CONFIGURED USING CRIMSON SOFTWARE (VERSION 2.0 OR
                                                                                          LATER)

                                                                                        DIGITALLY ISOLATED DeviceNet PORT CAPABLE OF
                                                                                          COMMUNICATING WITH ANY DeviceNet MASTER

                                                                                        EASY INSTALLATION

GENERAL DESCRIPTION                                                                    CONTENTS OF PACKAGE

   Both the Modular Controller Master (enhanced models) and Data Station                  - XCDN option card
Plus contain a proprietary expansion port which provides a high speed, parallel           - This hardware bulletin
architecture that extends the functionality and flexibility of the platform. This
approach allows these products to evolve concurrently with the latest advances         SPECIFICATIONS
in communications and standards, without sacrificing performance. This high
bandwidth channel has significantly greater throughput when compared to the            1. POWER REQUIREMENTS: 24 V @ 50 mA max. Power is supplied to the
traditional (external) serial gateway approach.                                           option card from the main board of the Modular Controller Master or Data
                                                                                          Station Plus.
   The XCDN option card adds a DeviceNet slave communication port to the
series. This isolated card protects user equipment from potentially harmful            2. COMMUNICATIONS:
ground loops while providing the ability to communicate to any high speed                 DeviceNet Port: The DeviceNet port has format and baud rates that are
DeviceNet master. Additionally, the XCDN connector is pluggable for easy                  software programmable up to 500K baud and are digitally isolated. This port
removal of the Modular Controller Master or Data Station Plus from the                    may be configured for various DeviceNet protocols. Check www.redlion.net
DeviceNet bus without disturbing communications with other devices on the                 for currently supported protocols.
bus.                                                                                      Isolation from XCDN Communication ports Modular Controller Master
                                                                                          or Data Station Plus: 1000 VDC for 1 minute.
   The XCDN communication card is easily installed by removing the blank
expansion port cover of your Modular Controller or Data Station Plus, and              3. CERTIFICATIONS AND COMPLIANCES:
plugging the XCDN card into the expansion port. Configuration is simple using             Refer to main unit manual or "Agency Approvals" section of Red Lion's
Red Lion's free Crimson 2.0 software.                                                        website for agency certifications.
                                                                                          ELECTROMAGNETIC COMPATIBILITY
SAFETY SUMMARY                                                                            Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
                                                                                             Control and Laboratory use.
   All safety related regulations, local codes and instructions that appear in the        Reference Modular Controller Master or Data Station Plus unit for EMC
literature or on equipment must be observed to ensure personal safety and to                 specifications
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection        4. ENVIRONMENTAL CONDITIONS:
provided by the equipment may be impaired.                                                Refer to the specifications of the Modular Controller Master or Data Station
                                                                                             Plus you are installing this card in.
   Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to         5. CONSTRUCTION: For indoor use only. Installation Category II, Pollution
persons or equipment in the event of a fault to the controller.                           Degree 2.

                                                                                       6. INSTALLATION REQUIREMENTS: See "Installing the XCDN Option
                                                                                          card" for more details.

                                                                                       7. WEIGHT: 2.3 oz (65.2 g)

                            CAUTION: Risk of Danger.
                       Read complete instructions prior to
                       installation and operation of the unit.

ORDERING INFORMATION                                                                         BLOCK DIAGRAM

MODEL NO.  DESCRIPTION                                          PART NUMBER                             TX/RX        4 CAN_H
                                                                                                                  B  2 CAN_L
   XCDN    DeviceNet option card for Modular Controller          XCDN0000                                            1 V-
SFCRM2    or Data Station Plus                                  SFCRM200
SFCRM2    Crimson 2.0 with G3/Data Station Manual 1            SFCRM2MC
           Crimson 2.0 with Modular Controller Manual 1

1 Use these part numbers to purchase Crimson 2.0 on CD with a printed                  +     ISOLATING
   manual, USB cable and RS-232 cable. Otherwise, download free of charge
   from www.redlion.net.                                                               -     DC : DC

                                                                                          A

                                                                                    1
INSTALLING THE XCDN OPTION CARD                                                            Caution: The expansion and main circuit boards contain static
                                                                                       sensitive components. Before handling the cards, discharge static
1. Remove power from the unit                                                          charges from your body by touching a grounded bare metal object.
2. Insert a flat-bladed screwdriver into the slot at the top of the expansion port     Ideally, handle the cards at a static controlled clean workstation.
                                                                                       Also, handle the cards by the edges only. Dirt, oil, or other
   cover. Gently apply pressure on the screwdriver in an upward direction until        contaminants that may contact the cards can adversely affect circuit
   the expansion port cover disengages from the unit as shown in Figure 1.             operation.
3. Verify that the option card knobs are in the "unlocked" position as shown in
   Figure 2.                                                                              Warning: Risk of Danger: Be sure to remove all power before
4. Carefully insert the option card into the expansion port opening while              removing the expansion port cover
   aligning the card-edge connector on the option card with the main board's
   header, as shown in Figure 3. Once aligned, gently press on the front of the
   card until it is flush with the front of the case.
5. Turn the option card knobs to the locked position as shown in Figure 4.

                                                                                         XCDN
                                                                                       NET STS

                   Figure 1                                                                                   Figure 2

                                                                                                V-
                                                                                                CAN_L
                                                                                                DRAIN
                                                                                                CAN_H
                                                                                                V+

                                                                                         XCDN
                                                                                       NET STS

                                                                                                       V-
                                                                                                       CAN_L
                                                                                                       DRAIN
                                                                                                       CAN_H
                                                                                                       V+

Figure 3    XCDN                                                                                              Figure 4
          NET STS

                                                                                    2
POWER SUPPLY REQUIREMENTS                                                                              SOFTWARE/UNIT OPERATIONS

NEW AND EXISTING INSTALLATIONS                                                                         LED
   The XCDN option card draws all of its power from the main board of the
                                                                                                       LED STATE                     XCDN CARD INDICATION
Modular Controller Master or Data Station Plus. The specifications of the
Modular Controller Master or Data Station Plus account for the power needs of                          OFF             Initializing
an option card.
                                                                                                       FLASHING GREEN  The device is online and is waiting on communications
COMMUNICATING WITH THE XCDN OPTION CARD                                                                                from other devices

CONFIGURING A XCDN OPTION CARD                                                                         GREEN           The device is online and has established
   The XCDN is configured using Crimson software. Crimson is available as a                                            communications with another device

free download from www.redlion.net, or it can be ordered on CD. Updates to                             FLASHING RED One or more established communications have timed out
Crimson for new features and drivers are posted on the website as they become
available. By configuring the XCDN using the latest version of Crimson, you                            RED             The device has detected an error that has rendered it
are assured that your unit has the most up-to-date feature set. Crimson software                                       incapable of communicating on the network (duplicate
can configure the XCDN through the RS232 PGM port, USB port, Ethernet                                                  MAC ID or bus activity).
port, or CompactFlash socket on your Modular Controller Master or Data
Station Plus. Additional information can be found in your Modular Controller                           CRIMSON SOFTWARE
Master or Data Station Plus hardware bulletin and the Crimson user manual.
                                                                                                          Crimson 2.0 software is available as a free download from www.redlion.net
DeviceNet PORT PROTOCOLS                                                                               or it can be purchased on a CD, see "Ordering Information" for part number. The
                                                                                                       latest version of the software is always available from the web site, and updating
   The XCDN option card has one DeviceNet port. This port may be configured                            your copy is free.
for various DeviceNet protocols. Check www.redlion.net for currently supported
protocols.                                                                                             TROUBLESHOOTING YOUR XCDN OPTION CARD

XCDN PORT PIN OUTS                                                                                        If for any reason you have trouble operating, connecting, or simply have
                                                                                                       questions concerning your new XCDN option card, contact Red Lion's technical
   Must use only NEC Class 2 or Limited Power Source (LPS) rated power                                 support. For contact information, refer to the back page of this bulletin for phone
supply.                                                                                                and fax numbers.

                                                                                                          EMAIL: techsupport@redlion.net
                                                                                                          Web Site: http://www.redlion.net

LED
                 V-
                        CAN_L
                              DRAIN
                                     CAN_H
                                            V+

V-
   Position 1 of the pluggable connector provides a CAN ground connection.

This terminal is isolated from the Modular Controller Master and Data Station
Plus.

CAN_L
   Position 2 of the pluggable connector provides the CAN_L bus line (active

low). This terminal is isolated from the Modular Controller Master and Data
Station Plus.

DRAIN (OPTIONAL)
   Position 3 of the pluggable connector is provided for optional drain

connections. This position is available only to tie drain wires together or to earth
ground. There is no internal connection to earth ground. The DRAIN position is
not connected to any circuitry internal to the XCDN option card or Modular
Controller Master and Data Station Plus.

CAN_H
   Position 4 of the pluggable connector provides the CAN_H bus line (active

high). This terminal is isolated from the Modular Controller Master and Data
Station Plus.

V+ (OPTIONAL 24 VDC)
   Position 5 of the pluggable connector is provided for optional 24 VDC

connections. This position is available only to tie 24 VDC wires together. The
XCDN card neither provides 24 VDC power nor uses 24 VDC power through
this connection. The V+ position is not connected to any circuitry internal to the
XCDN option card or Modular Controller Master and Data Station Plus.

                                                                                                    3
                                                        LIMITED WARRANTY

                          The Company warrants the products it manufactures against defects in materials and workmanship
                          for a period limited to two years from the date of shipment, provided the products have been stored,
                          handled, installed, and used under proper conditions. The Company's liability under this limited
                          warranty shall extend only to the repair or replacement of a defective product, at The Company's
                          option. The Company disclaims all liability for any affirmation, promise or representation with
                          respect to the products.

                          The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against
                          damages, claims, and expenses arising out of subsequent sales of RLC products or products
                          containing components manufactured by RLC and based upon personal injuries, deaths, property
                          damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be
                          to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
                          Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
                          Act (P.L. 93-637), as now in effect or as amended hereafter.

                          No warranties expressed or implied are created with respect to The Company's products except those
                          expressly contained herein. The Customer acknowledges the disclaimers and limitations contained
                          herein and relies on no other warranties or affirmations.

Red Lion Controls              Red Lion Controls              Red Lion Controls                                                                      Red Lion Controls
Headquarters                          Europe                          India                                                                                          China
20 Willow Springs Circle
York PA 17406                    Printerweg 10             54, Vishvas Tenement                                                                 Unit 101, XinAn Plaza
Tel +1 (717) 767-6511     NL - 3821 AD Amersfoort          GST Road, New Ranip,                                                 Building 13, No.99 Tianzhou Road
Fax +1 (717) 764-0839     Tel +31 (0) 334 723 225  Ahmedabad-382480 Gujarat, India
                          Fax +31 (0) 334 893 793          Tel +91 987 954 0503                                                       ShangHai, P.R. China 200223
                                                          Fax +91 79 275 31 350                                                                Tel +86 21 6113-3688
                                                                                                                                              Fax +86 21 6113-3683
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved