器件描述

RF modules WL I/O slave St ation 16dc in

参数

Manufacturer: Omron
Product Category: RF Modules
RoHS: Yes
Brand: Omron Automation and Safety

WT30-SID16器件文档内容

FA Wireless SS Terminals

WT30

Construct a Wireless System for ON/OFF
Data Collection That Is Ideal for Monitoring
Production Site Equipment

Wireless Slave Station equipped with I/O.
Height of 90 mm and DIN Rail mounting enables installation in

control panels.
Easily check wireless communications status from indicator

display.
I/O Slave Stations can also be used as Slave Stations in WD30

systems.
Conforms to radio wave standards for Japan, China (pending),

USA, and Europe.

Ordering Information

List of Models

      Wireless Unit model                         Type                               Specifications/No. of I/O points
WT30-M01-FLK                  Serial master               RS-232C
WT30-SID16                    I/O slaves                  16 DC inputs (NPN/PNP)
WT30-SMD16                                                8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN)
WT30-SMD16-1                                              8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP)

Note: An Antenna and Mounting Brackets are not included with the Wireless SS Terminal.

Accessories

Antennas                                                         Applicable Standards

        Model                              Type                   FCC part 15.247 (USA)
WT30-AT001     Magnet-base Antenna (2 antennas per set)
WT30-AT002     Flat Diversity Antenna (1 antenna)                EN 300 440-2 (Europe)
WT30-AT003     Pencil Antenna (2 antennas per set)
                                                                  ARIB STD-T66 (Japan)

                                                                                       (China) (approval pending)

Communications Cables                                                     Conformity to Safety Standards

        Model         Length            Application              Always use a Class 2 power supply to conform to UL standards.
XW2Z-0100U-3   1m             For personal computer
XW2Z-0200U-3   2m                                                Main Class 2 Power Supplies
XW2Z-0500U-3   5m             Cross cable for PLC
XW2Z-0200U-5   2m                                                OMRON Switching Power Supplies
XW2Z-0500U-5   5m
                                                                  S8VS (15 W, 30 W, 60 W type)
                                                                  S82K (15 W, 30 W, 50 W, 90 W type)

Other                                                                       Conformity to EN Standards

        Model                              Type                  Use a DC power line less than 3 m to conform to EN standards. If a
WT30-FT001     DIN Rail Mounting Bracket (for TH35-7.5)          power line of 3 m or longer is required, extend the length at the
WT30-FT002     DIN Rail Mounting Bracket (for TH35-15)           Switching Power Supply's primary side (i.e., the AC power line).
WT30-FT003     Surface Mounting Bracket (screw-mounting)
               (2 brackets per set)                              Applicable Countries
WT30-FT011     Flat Diversity Antenna Mounting Brackets
               (with magnets)                                    Wireless standards have been met for the following countries. The
WT30-CA2M      Antenna Extension Cable (1 cable, 2 m)            product cannot be used in any other countries.

                                                                 Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia,
                                                                 Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy,
                                                                 Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
                                                                 Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland,
                                                                 UK, USA

                                                                    FA Wireless SS Terminals WT30                               1
Specifications

Ratings

                       Item                              WT30-M01-FLK Serial Master    WT30-SID16/SMD16/SMD16-1 I/O Slaves

Power supply           Rated voltage      24 V DC
(wireless                                 20.4 to 26.4 V DC
communications         Allowable voltage
power supply)          range              3 W max. (See note 1.)

                       Power consumption

Error output/output Rated voltage         ---                                          24 V DC
                                                                                       20.4 to 26.4 V DC
power supply           Allowable voltage  ---
(for output circuits)  range

Insulation resistance                     20 M min. (at 100 V DC) between the power 20 M min. (at 100 V DC) between the power

                                          supply and chassis                           supply and all I/O and I/O power supply and

                                                                                       between the power supply and chassis

Dielectric strength                       1,500 V AC for 1 min between power supply    1,500 V AC for 1 min between the power supply
                                          and chassis                                  and all I/O and I/O power supply and between
                                                                                       the power supply and chassis

Noise immunity                            IEC61000-4-4. 1 kV (power supply line)

Vibration resistance (See note 2.)        JIS C0040
                                          Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of 50 m/s2, whichever is smaller
                                          (DIN Rail mounting: single amplitude of 0.1 mm or acceleration of 15 m/s2)
                                          10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions

Shock resistance                          Conforms to JIS C0041: 300 m/s2 3 times each in X, Y, and Z directions

Ambient operating temperature             -10 to 55C (with no condensation or icing) Number of simultaneously ON I/O points

                                          (with the Terminal mounted with the dust-proof 10 max.: -10 to 55C (with no condensation or

                                          label facing up)                             icing)

                                                                                       16 max.: -10 to 50C (with no condensation or

                                                                                       icing)

                                                                                       (with the Terminal mounted with the dust-proof

                                                                                       label facing up)

Ambient operating humidity                25% to 85% (with no condensation or icing)

Ambient environment                       No corrosive gases

Storage temperature                       -25 to 65C (with no condensation or icing)

Protective structure                      IP20

Terminal construction Power supply and I/O Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent)

                       Serial             D-sub, 9-pin (female) Inch screws (OMRON ---
                                          XM2F-0910-132 or equivalent), Master station
                                          only

Safety standards                          UL: UL508 (Listing)

Weight                                    330 g max.

Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup.
        2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration.

Wireless Interface Specifications

                              Item                                                             Specifications
Wave type                                 Spread Spectrum (direct sequence; DS-SS)
Communication method                      Simplex
Frequency band                            2,401 to 2,480.2 MHz
Number of channels                        67 channels (based on switching)
Transmitter output power                  10 mW/MHz
Baud rate between wireless stations       100 kbps
Communications distance (See note.)       Indoors: 60 m min. (approx. 50 m min. with Magnet-base Antennas and Flat Diversity Antennas)
                                          Outdoors: Approx. 300 m min. (anticipated distances)
Error detection method                    (without using relay stations)
Relay functions                           CRC-CCITT (16 bits)
Number of stations per area (See note.)   One stage using I/O slave for the serial master configuration.
Number of I/O Slaves connected            10 sets max. (recommended)
                                          64 max.

Note: Varies according to the installation environment.

Package Contents

WT30 FA Wireless SS Terminal Terminal labels (I/O Slaves only)

Instruction Sheet                  Adhesive non-slip feet (Serial Master only)

2       FA Wireless SS Terminals WT30
Nomenclature

Serial Master Station                                                                                 Unit No. Switch

Antenna terminal (ANT1)        Unit No. switch                                                        Set the unit number of the Serial Master Station
                               Set the unit number of the Serial Master Station.                      Default: 00

                                              Node setting switch (WNODE)                              Node Setting Switch (WNODE)
                                              Set the number of connected I/O Slave Stations.
                                                                                                      Set the number of connected I/O Slave Stations.
                                                             Channel setting switch (WCH)             Set the node number of the Slave Stations being used as I/O Slave
                                                             Set the communications frequency         Stations. The Slave Station functions as a relay station when the
                                                             channel.                                 node number is set to 99.
                                                                                                      Default: 01
                                                                             Antenna terminal (ANT2)
                                                                                                       Channel Setting Switch (WCH)
Status                                                                         Received
indicators                                                                     signal                 Set the communications frequency.
                                                                               strength               Default: 02
                                                                               indicator
                                                                                                       Function Setting Switch
                                                                               Special
                                                                               function
                                                                               switch

                                                                                                      Serial Master Station

                                                                                                       No.  Applicable       ON functions            OFF functions
                                                                                                      1        mode

Mode selection switch                              Function setting switch                            2     RUN mode    Holds I/O status data   Clears I/O status data
Switch between RUN,                                Make the detailed settings                         3                 when a                  when a
TEST, and SET mode.                                for RUN/TEST/SET mode.                             4                 communications error    communications error
                                                                                                      5                 occurs.                 occurs.
    Power supply terminal      RS-232C Terminal                                                       6
    Supply power to the WT30.  Connect the PLC, personal computer, etc.                               7
                                                                                                      8
                                                                                                      9                 Enable scan list        Disable scan list
                                                                                                      10
                         Serial communications                                                                          Relays used             Relays not used
                         setting switch
                         Set the baud rate.                                                                 TEST mode Signal strength monitor Signal strength monitor

I/O Slave Station                                                                                                      disabled                enabled

                                                                                                                        All channels            Specified channels

                                                                                                                        automatically switched

                                   Node setting switch (WNODE)                                                          ---                     ---
                                   Set the unit number of the I/O Slave Station.
                                                                                                            SET mode Scan list recognition Nothing done
                                      I/O terminal status indicators (0 to 7 or 8 to 15)
                                      The contact status is displayed.                                                  Registers specified I/O Registers all I/O slaves

Antenna terminal (ANT1)                           Channel setting switch (WCH)                                          slave                   automatically
                                                  Set the communications frequency.
                                                                                                                        Recognizes serial       Ignores serial numbers
                                                                  Antenna terminal (ANT2)                               numbers

                                                                                                            Not used ---                        ---

Status                                                                                                I/O Slave Station
indicators
                                                                               Received                No.  Applicable       ON functions            OFF functions
                                                                               signal                 1        mode
                                                                               strength
                                                                               indicator              2
                                                                                                      3
                                                                                                      4     RUN mode    Holds I/O status data   Clears I/O status data
                                                                                                      5                 when a                  when a
                                                                                                      6                 communications error    communications error
                                                                                                      7 to              occurs.                 occurs.
                                                                                                      10
                                                                                                                        Input hold              Normal mode

                                                                                                                        Input filter: 100 ms Input filter: 10 ms

                                                                                                            TEST mode Signal strength monitor Signal strength monitor

                                                                                                                        disabled                enabled

                                                                                                                        All channels            Specified channels

Mode selection switch                                                                                                   automatically switched

Switch between RUN,                                                                                                     Installation test       Nothing done
                                                                                                                        function
TEST, and SET mode.      I/O terminals
                         Connect the contact
                                                Special function switch

                         signals.                                                                           Not used ---                        ---

                                              Function setting switch

Power supply terminal                         Make the detailed settings

Supply power to the WT30                      for RUN/TEST mode.

and output circuits.

                                                                                                            FA Wireless SS Terminals WT30                           3
Serial Communications Setting                                           Display
  Switch
                                                                            Indicator     Color Status Meaning (primary error)

No.          Function                  ON          OFF                 PWR               Green Lit       Power is being supplied.
1
      Communications setting Detailed Default settings                                           Not lit Power is not being supplied.
2
3     selection                  settings (baud rate: 9,600 bps;        ERR               Red Lit         Error output is ON:
4                                                                                                         Wireless device error or
                                 (settings for data length: 7 bits;     (Slave Station)                   wireless communications
5                                                                                                         error. (See note)
6                                No. 2 to 8 parity: even; stop bits:
7
8                                used)      2)

                                            Settings for No. 2 to 8                              Not lit  No wireless device error or
                                                                                                          wireless communications
                                            are ignored.                                                  error.

      Baud rate (bps)            1          0

      (See note.)                2          0                           COMM              Yellow Lit      Serial communications in
                                                                                                          progress.
      Total value = 0: 1,200 4              0                           (Master Station)

                   = 1: 2,400                                                                    Not lit No serial communications.

                   = 2: 4,800                                           0 to 15           Yellow Lit/Not lit ON/OFF status for input or
                   = 3: 9,600
                                                                        (Slave Station)                   output signals

                   = 4: 19,200                                          RSSI              Red/ Lit/       Receiving Signal Strength

                   = 5: 38,400                                                            Yellow/ All not lit Indicator monitor: Number of

                   = 6: 57,600                                                            Green           indicators lit (receiving signal

                   = 7: 115,200                                                                           strength 1 to 9)

                                                                                                          Receiving signal strength less

      Data length                8 bits     7 bits                                                        than 0 to 1.

      Parity                     None       Yes                         MS                Green Lit       Communications are normal.

                                 Odd        Even                        (Module Status)          Flashing TEST mode or SET mode has

      Stop bits                  1 bit      2 bits                                                        been activated.

                                                                                          Red Lit         A fatal error has occurred that
                                                                                                          cannot be recovered from.
Note: For example, if pins number 2, 3, and 4 are all ON, the total is                                    Replace the Unit
        7, which corresponds to a baud rate of 115,200 bps.

                                                                                                 Flashing A non-fatal error has occurred
                                                                                                              that can be recovered from by
                                                                                                              resetting the system.

                                                                                          ---    Not lit Power is not being supplied or

                                                                                                          the system is resetting.

                                                                        WS                Green  Lit      The station has joined the
                                                                        (Wireless
                                                                        Status)                           wireless network.

                                                                                                 Flashing Permission to join wireless
                                                                                                              network received from Serial
                                                                                                              Master Station (Slave Station)

                                                                                          Red Lit         A fatal error has occurred that
                                                                                                          cannot be recovered from.

                                                                                                 Flashing Error from which recovery is
                                                                                                              possible

                                                                                          ---    Not lit Wireless communications are

                                                                                                          not in progress.

                                                                        Note: When using the WD30 as the Serial Master Station, the ERR
                                                                                indicator will light if normal I/O communications are not
                                                                                possible due to an error in the host network.

4             FA Wireless SS Terminals WT30
Wiring

Serial Master Station (WT30-M01-FLK)

                                                                                                                      D-sub, 9-pin, Female End at WT30

                                                                                                   RS-232C Connector     Pin No. Signal I/O direction

                                                                                                        54321         1                ---  ---

                                                                                                                      2                RD   Output

                                                                                                                      3                SD   Input

WT30                                                     Power supply terminal                     9876               4                ---  ---
                                                         Supply power to the Unit
                                                                                                                      5                SG   ---

                                                                                                                      6                ---  ---

                                                                                                                      7                ---  ---

                                                                                                                      8                ---  ---

                                                                                                                      9                ---  ---

I/O Characteristics

I/O Slave Station                                                                                 Item                            Specifications

WT30-SID16

                                                                                                   Input voltage 24 V DC

      Error output                              Inputs       Error output                          Allowable          20.4 to 26.4 V DC
      power supply Inputs                                        (PNP)
                                           IN   56                          Input Characteristics  voltage range
            VG 01 2            3 COM 4                   7 COM ERRP
                                                                                                   Input              4.7 k (typical)
                                                                                                   impedance

                                                                                                   Input current 5 mA (typical)

                                                                                                   ON voltage/ 17.4 V DC, 3.0 mA min.
                                                                                                   current
                                                                                                   characteristics

        24 V DC 0 V 8  9 10    11 COM 12        13 14    15 COM ERRN                               OFF voltage/ 5.0 V DC, 1.0 mA max.
                                            IN                                                     current
      Power supply     Inputs                   Inputs        Error output                         characteristics
                                                                 (NPN)
                                                                                                   Input filter       10 ms/100 ms (Selected using switch.)

                                                                                                   Input voltage 24 V DC

WT30-SMD16                                                                                         Allowable          20.4 to 26.4 V DC
WT30-SMD-16-1                                                                                      voltage
                                                                            Output/Error Output
                                                                               Characteristics     Max.               100 mA max. per output (at 20.4 to 26.4 V DC)
                                                                                                   switching          Simultaneous usage of error output NPN/PNP
                                                                                                   current            is not possible.

Error output/output                                      Error output                              Leakage            0.1 mA max.
   power supply Inputs                                      (PNP)                                  current
                                                Inputs
            VG0 1 2                        IN            COM ERRP                                  Residual           1.0 V max.
                               3 COM 4          567                                                voltage

                                                                                                   Fuse               One for every two outputs except for error
                                                                                                                      output circuits, which have one for every NPN/
                                                                                                                      PNP output. (No fuses can be replaced by the
                                                                                                                      user.)

      24 V DC 0 V 0 1 2 3 COM 4 5 6 7 COM ERRN
                                                           OUT

      Power supply Outputs                      Outputs  Error output
                                                            (NPN)

                                                                                                   FA Wireless SS Terminals WT30                             5
Input Circuit Diagram                                                                                                         Output Circuit Diagram (NPN)

                                                                               IN 0                                                                               V
                                                                               IN 1                                                                               OUT 0
                                                                               IN 2
                Secondary internal circuit                                                                                    Secondary internal circuit          OUT 1
                                                                               IN 15
                                                                               COM (IN)                                                                   Fuse

Error Output Circuit Diagram                                                                                                                                      OUT 2

                                                                             V                                                                            Fuse    OUT 7
                                                                   Fuse ERRP                                                                                Fuse  G

                                                                   Fuse                                                       Output Circuit Diagram (PNP)
                                                                             ERRN
                                                                             G                                                                                                               Fuse V

                                                                                                                                                                  OUT 0

                                            Secondary internal circuit                                                        Secondary internal circuit          OUT 1

                                                                                                                                                          Fuse

                                                                                                                                                                  OUT 2

                                                                                                                                                                  OUT 3

                                                                                                                                                                  OUT 7
                                                                                                                                                                  G

Dimensions                                                                                                                    I/O Slave Station

Note: All units are in millimeters unless otherwise indicated.                                                                WT30-SID16
                                                                                                                              WT30-SMD16
Serial Master Station                                                                                                         WT30-SMD16-1

WT30-M01-FLK                                                                                                                                                                            105

          13.3                                                          105                       13.3                                               90
   (15)
    60 40                                                               120                                                                                                                            DIN rail mounting bracket
   (15)                                                                                                         Four, 5 dia.                                                                           WT30-FT001 or WT30-FT002
                                                                                                                                                    7.3
                                                                        Surface mounting bracket
                                                                        WT30-FT003

6  FA Wireless SS Terminals WT30
With Magnet-base                                                         With Flat Diversity                                           With Pencil Antenna
Antenna                                                                  Antenna
                                                                                                                                       WT30-AT003
WT30-AT001                                                               WT30-AT002
                                                                                                                                                   150                             40
             (34)                                                                   (23)
                                                                                                                                                              (46)
                                                                                               R50
                                                                                                                 20                                     (46)

     R38
                         R40

                (32)          4.6

(38)

                                                                                                                                                                                                                                                     Serial Master Station
                                                                                                                                                                                                                    Surface Mounting Bracket
                                                                                                                                                                                                                    WT30-FT003

                      I/O Slave Station                                  I/O Slave Station                  DIN Rail mounting bracket
                                              DIN Rail mounting bracket                                     WT30-FT001 or
                                              WT30-FT001 or                                                 WT30-FT002
                                              WT30-FT002
                                                                         Flat Diversity Antenna                                                    Pencil Antenna
Magnet-base Antenna
                                                                         WT30-AT002                                                                WT30-AT003
WT30-AT001

                                                                                                               57.5  Three, 3 dia.
                                                                                                            26

115                                                                                                57.5 52                                                                     75
                                                                         10.5 dia.                                                     10.5 dia.

                                                                                                                     2010

                              2010

     35.8 dia.
        39

DIN Rail Mounting                                                        Surface Mounting                                              Flat Diversity Antenna Mounting
Bracket                                                                  Bracket                                                       Brackets (with magnets)

WT30-FT001                                                               WT30-FT003                                                    WT30-FT011
WT30-FT002

                                                                                                                                       FA Wireless SS Terminals WT30                   7
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. N139-E1-01 In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

Industrial Devices and Components Division H.Q.  Printed in Japan
Wireless Components Department                   0105
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7116/Fax: (81)75-344-7189
This datasheet has been downloaded from:
            datasheet.eeworld.com.cn

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.EEworld.com.cn

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright Each Manufacturing Company

小广播

WT30-SID16器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved