datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索
 

VE-JTN-MX-F2

器件型号:VE-JTN-MX-F2
器件类别:电源    DC_DC转换器   
厂商名称:VICOR
厂商官网:http://www.vicorpower.com/
下载文档

器件描述

Isolated DC/DC Converters VI J00/200 - 110 Vin, 18.5 Vout, 75 W, M Product Grade

参数

产品属性属性值
产品种类:
Product Category:
Isolated DC/DC Converters
制造商:
Manufacturer:
Vicor
商标:
Brand:
Vicor

VE-JTN-MX-F2器件文档内容

                                                                              Half       Brick,          DC-DC Converters

                                                                                                                                             VI-J00

                                                                                                                                             VE-J00

                                                                                                                              ®        S

                                                                                                                   C             US C  NRTL  US

                                                                                                                      25 to 100 Watts

Features & Benefits                                      Product Highlights

•  Isolated output                                       The VI-J00 MiniMod family established a new standard in component-level DC-DC

•  Up to 50W/in3                                         converters. This “junior” size complement to the higher power VI-200 family offers up

                                                         to 100W of isolated and regulated power in a board mounted package. With thousands

•  cURus, cTÜVus                                         of input/output/power combinations, and with a maximum operating temperature

•  CE Marked                                             rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system

•  Up to 90% efficiency                                  designers to meet demanding time to market requirements.

•  Size: 2.28” x 2.4” x 0.5”                             Utilizing Vicor’s “zero-current-switching” forward converter technology, proven

   (57,9 x 61,0 x 12,7mm)                                by an installed base of over 8 million units, the MiniMod family combines state of

                                                         the art power density with the efficiency, low noise and reliability required by next

•  Remote sense and current limit                        generation power systems.

•  Logic disable

•  Wide range output adjust

•  ZCS power architecture

•  Low noise FM control

•  RoHS compliant (VE verisons)

Part Numbering

                                                     VI  —  J        6        1     —    C        W

   Family                   Series            Input                           Output                           Grade                   Power

VI =Non-RoHS                J = J00  0 = 12V  N = 48V          Z  =  2V       M = 10V       K  =  40V    E  =  –10 to 100°C      ≥ 5V            < 5V

VE = RoHS                            V = 24V  4 = 72V          Y  =  3.3V     1 = 12V       4  =  48V    C  =  –25 to 100°C   W  = 100W          W = 20A

                                     1 = 24V  T = 110V         0  =  5V       P = 13.8V     H  =  52V    I  =  – 40 to 100°C  X  = 75W           X = 15A

Note: For additional                 W = 24V  5 = 150V         X  =  5.2V     2 = 15V       F  =  72V    M  =  –55 to 100°C   Y  = 50W           Y = 10A

pa                c                k                a         ging options,           2 = 36V  6 = 300V         W  =  5.5V     N = 18.5V     D  =  85V                                       Z  = 25W           Z = 5A

pl        e                a                s                e see page 5.            3 = 48V  7 = 150/300V     V  =  5.8V     3 = 24V       B  =  95V               

                                                               T  =  6.5V     L = 28V

                                                               R  =  7.5V     J = 36V

VI-J00 DC-DC Converters                                              Rev 3.0

Page 1 of 7                                                       06/2017
                                                                                                                                                 VI-J00,            VE-J00

Maximum Power Available for VI-Jxx-xx

                       Input                                                                                          Output

                       Low                           Designators                                                VOUT Designators

Voltage                Line                     VIN                                                                    13.8      18.5

Nom. (Range)           75%        Transient[a]                    2     3.3  5     5.2  5.5  5.8  6.5  7.5  10  12           15        24    28  36  40     48  52  72  85        95

                       Max

                       Power                                      Z     Y    0     X    W    V    T    R    M   1      P     2   N     3     L   J   K      4   H   F   D         B

12 (10 – 20)           n/a            22        0                 X     X    Y     Y    Y    Y    Y    Y    X   X      X     X   X     X     X   X   X      X   X   X   X         X

24 (10 – 36)           n/a            n/a       V                 --    Y    Y     Y    Y    Y    Y    Y    Y   Y      Y     Y   Y     Y     Y   Y   Y      Y   --  --  --      --

24 (21 – 32)           18             36        1                 W     W    W     W    W    W    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

24 (18 – 36)           n/a            n/a       W                 W     W    W     W    W    W    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

36 (21 – 56)           18             60        2                 Y     Y    Y     Y    Y    Y    Y    Y    X   X      X     X   X     X     X   X   X      X   X   --  --      --

48 (42 – 60)           36             72        3                 W     W    W     W    W    W    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

48 (36 – 76)           n/a            n/a       N                 W     W    X     X    X    X    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

72 (55 – 100)          45             110       4                 W     W    W     W    W    W    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

110 (66 – 160)         n/a            n/a       T                 W     W    X     X    X    X    X    X    W   W     W      W   W     W    W    W   W    W     W   W   --      --

150 (100 – 200)        85             215       5                 W     W    W     W    W    W    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

150 (100 – 375)        n/a            n/a       7                 Y     Y    Y     Y    Y    Y    Y    Y    X   X      X     X   X     X     X   X   X      X   X   --  --      --

300 (200 – 400)        170            425       6                 W     W    W     W    W    W    X    X    W   W     W      W   W     W    W    W   W    W     W   W   W      W

[a] Transient voltage  for 1 second.

Converter Specifications

(Typical at TBP = 25°C, nominal line and 75% load, unless               otherwise  specified.)

Input Specifications

                                           VI-J00 E-Grade                                              VI-J00 C-, I-, M-Grade

Parameter                    Min                Typ                          Max             Min                Typ                    Max           Units              Test

                                                                                                                                                                    Conditions

Inrush charge                                   60 x 10-6                                                   60 x 10-6            100 x 10-6         Coulombs        Nominal line

Input reflected                                 10%                                                             10%                                  IIN            Nominal line,

ripple current – pp                                                                                                                                                 full load

                                                                  VIN                                                 VIN                                           120Hz,
                                      ( ) 25+20 Log                                                    ( ) 30+20 Log                                 dB
                                                                  VOUT                                                VOUT                                          nominal line
Input ripple

rejection                                                                                                             VIN                                           2400Hz,
                                                                                                       ( ) 20+20 Log
                                                                                                                      VOUT                           dB             nominal line

No load power                                   1.35                         2                                  1.35                   2             Watts

dissipation

VI-J00 DC-DC Converters                                                                    Rev 3.0

Page 2 of 7                                                                                06/2017
                                                                                                                                   VI-J00, VE-J00

Converter Specifications (Cont.)

(Typical at TBP = 25°C, nominal line and 75% load, unless          otherwise  specified.)

Output Characteristics

                                      VI-J00 E-Grade                                             VI-J00     C-, I-, M-Grade

Parameter               Min                        Typ             Max          Min                         Typ              Max   Units       Test

                                                                                                                                               Conditions

Setpoint accuracy                                  1%              2%                                       0.5%             1%    VNOM

Load/line                                                          0.5%                                     0.05%            0.2%  VNOM        LL to HL, 10%

regulation                                                                                                                                     to Full Load

Load/line                                                          1%                                       0.2%             0.5%  VNOM        LL to HL, No

regulation                                                                                                                                     Load to 10%

Output                                             0.02                                                     0.01             0.02  % / °C      Over rated

temperature drift                                                                                                                              temp.

Long term drift                                    0.02                                                     0.02                   %/1K hours

Output ripple – pp:                                                                                                                            20MHz

            2V, 3.3V                                               200                                      100              150   mV          bandwidth

                   5V                                              5%                                       2%               3%    VNOM        20MHz

                                                                                                                                               bandwidth

            10 – 95V                                               3%                                       0.75%            1.5%  VNOM        20MHz

                                                                                                                                               bandwidth

Trim range[a]          50%                                         110%         50%                                          110%  VNOM

Total                                                                                                                                          0.25V max.

remote sense            0.5                                                     0.5                                                Volts       neg. leg

compensation

Current limit          105%                                        135%         105%                                         125%  IFULL LOAD  Automatic

                                                                                                                                               restart

Short circuit          105%                                        140%         105%                                         130%  IFULL LOAD  Automatic

current                                                                                                                                        restart

[a] 10V to 15V outputs, or “V” input  range  have  standard  trim  range ±10%.  Consult factory  for wider  trim range.

95V output –50 + 0% trim range.

Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output        related application information,

please refer to output connections on page 5.

Control Pin Specifications

                                      VI-J00 E-Grade                                             VI-J00 C-, I-, M-Grade

Parameter               Min                        Typ             Max          Min                         Typ              Max   Units       Test

                                                                                                                                               Conditions

Gate out                                           50                                                       50                     Ohms

impedance

Gate in impedance                                  1000                                                     1000                   Ohms

Gate in high                                       6                                                                         6     Volts       Use open

threshold                                                                                                                                      collector

Gate in low             0.65                                                    0.65                                               Volts

threshold

Gate in low                                                        6                                                         6     mA

current

VI-J00 DC-DC Converters                                                         Rev 3.0

Page 3 of 7                                                                     06/2017
                                                                                                                                VI-J00,  VE-J00

Converter Specifications (Cont.)

(Typical at TBP = 25°C, nominal line and 75% load, unless        otherwise  specified.)

Dielectric Withstand Characteristics

                            VI-J00 E-Grade                                                VI-J00 C-, I-, M-Grade

Parameter           Min                         Typ              Max        Min                   Typ                  Max      Units          Test

                                                                                                                                         Conditions

Input to output     3,000                                                   3,000                                               VRMS          Baseplate

                                                                                                                                               earthed

Output to           500                                                     500                                                 VRMS

baseplate

Input to baseplate  1,500                                                   1,500                                               VRMS

Thermal Characteristics

                            VI-J00 E-Grade                                                VI-J00 C-, I-, M-Grade

Parameter           Min                         Typ              Max        Min                   Typ                  Max      Units          Test

                                                                                                                                         Conditions

Efficiency                                      78 – 88%                                  80 – 90%

Baseplate to sink                               0.14                                              0.14                          °C/Watt  With Vicor

                                                                                                                                         P/N 20267

[d] No overtemp protection in booster modules.

Mechanical Specifications

                            VI-J00 E-Grade                                                VI-J00  C-, I-, M-Grade

Parameter           Min                         Typ              Max        Min                   Typ                  Max      Units          Test

                                                                                                                                         Conditions

Weight              2.9                         3.2              3.6        3.4                   3.8                  4.1      Ounces

                    (82.8)                      (92)             (101.2)    (96.3)                (107)                (117.7)  (Grams)

Product Grade Temperatures

Parameter                                       Storage                     Operating                    Units                  Notes

E                                               -20 to +105                 -10 to + 100                           °C

C                                               -40 to +105                 -25 to + 100                           °C

I                                               -55 to +105                 -40 to + 100                           °C

M                                               -65 to +105                 -55 to + 100                           °C

Maximum Capacitance, Rated  Output Voltage                       <5V

Rated VOUT (V)                                  IOUT Rating (A)             CMAX (µF)                    IOUT Rating (A)                 CMAX (µF)

2 to <3                                         ≤10                         1500                         >10 to 20                       5000

3 to <5                                         ≤10                         1000                         >10 to 20                       5000

Maximum Capacitance, Rated  Output Voltage                       ≥5V

Rated VOUT (V)              POUT Rating (W)                                 CMAX (µF)                    POUT Rating (W)                 CMAX (µF)

5 to <7.5                                       ≤50                         1000                         >50 to 100                      1500

7.5 to <10                                      ≤50                         400                          >50 to 100                      700

10 to <28                                       ≤50                         400                          >50 to 100                      500

>28                                             ≤50                         150                          >50 to 100                      250

VI-J00 DC-DC Converters                                                     Rev 3.0

Page 4 of 7                                                                 06/2017
                                                                                                                   VI-J00, VE-J00

Basic Module Operation

                                                     C1a                                          C2a

                                     F1                       +IN    Zero Current +OUT

                                       C3                            Switching
                                                                     Converter
                                                              –IN               –OUT

                                                     C1b                                          C2b

C3 (µF)      =  400

                VIN Minimum

Figure 1 —   Basic module operation  requires fusing, grounding,     bypassing capacitors.*  See  Design Guide  &  Applications  Manual.

Output Connections and Considerations                                         Storage

The permissible load current [e] must never be exceeded during                Vicor products, when not installed in customer units, should

normal, abnormal or test conditions. Converters subject to                    be stored in ESD safe packaging in accordance with

dynamic loading exceeding 25% of rated current must be                        ANSI/ESD S20.20, “Protection of Electrical and Electronic

reviewed by Vicor Applications Engineering to ensure that the                 Parts, Assemblies and Equipment” and should be maintained

converter will operate properly.                                              in a temperature controlled factory/warehouse environment

Under dynamic load, light load, or no load conditions, the                    not exposed to outside elements controlled between the

converter may emit audible noise. Converters that utilize remote              temperature ranges of 15ºC and 38ºC. Humidity shall not be

sense may require compensation circuitry to offset the phase                  condensing, no minimum humidity when stored in an ESD

lag caused by the external output leads and load impedance.                   compliant package.

Remote Sense leads must be protected for conditions such as

lead reversal, noise pickup, open circuit, or excessive output lead

resistance between the sense point and the converters output

terminals. For applications that may draw more than the rated

current, a fast acting electronic circuit breaker must be utilized

to protect the converter. Under no circumstance should the

rated current be exceeded. Utilizing or testing of current limit or

short circuit current will damage the converter. Ensure that the

total output capacitance connected to the converter does not

exceed the limits on Page 4.

[e] Permissible load current:  Nominal Power Rating

                                  Nominal VOUT

VI-J00 DC-DC Converters                                              Rev 3.0

Page 5 of 7                                                          06/2017
                                                                   VI-J00 Mechanical                                       Diagram                                       VI-J00,     VE-J00

Mechanical   Drawing

                                                           2.28
                                                           (57,9)                         Standard                             RoHS

                                  .49                        1.30                         0.080 Dia (2) places                 0.080 Dia (2) places
                                                             (33,0)
                                  (12,4)  .65                                             Solder plate                         Matte tin over copper

             .30±.015                     (16,5)                                          over copper alloy                    alloy

             (7,6)±(0,38)

                                                                                                                                           Pin #      Function

                                     4                                  9                                                                  1          +In

                                                                                                                                           2          Gate In

                                     3                                  8                                                                  3          Gate Out

             2.10                         VI-J00                        7                                 1.40                             4          -In
             (53,4)                                                                                       (35,6)
                                                                                                  1.00                                     5          +Out
                                     2                                  6                 .70     (25,4)
                                                                                          (17,8)
                                                                                  .40                                                      6          +Sense
                                                                                (10,2)
                                     1                                  5                                                                  7          Trim
                                                                                                        .35± .015
                                                                                                      (8,9)±(0,38)                         8          –Sense

                                                                                                                                           9          –Out

             .15                                               FULL  R                    Standard                             RoHS

             (3,8)                                                                        0.040 (1,0) Dia (7)      places      0.040 Dia (7) places

                                                        .15                               Solder plate                         Matte tin over copper
                                                        (3,8)
                                                                                          over copper alloy                    alloy

                                                                                          Product ID                                                             2.40
                                                                                                                                                                 (61,0)
                                                           1.90                           this surface

                                                           (48,3)                                                                     .30                       1.75
                                                                                                                                      (7,6) Min.                (44,4) Max.
                                                                           .22
                                                                           (5,6)  Min.

                                                                                          .50     +.030 (0,76)
                                                                                                  -.000 (0)
                                                                                          (12,7)

                                                                                                             .01

             .12
             (3,0)
                                                                                                                                                  Aluminum Base

PACKAGING OPTIONS

Flangeless package                                                              Flangeless package                                                              MegaMod Jr.

                                                                           with integral heat sink                                                Chassis mount alternatives, one, two

                                                                                                                                                      or three outputs: up to 300W

           2.28”L x 1.80”W x 0.50”H                                  Longitudinal, 0.25”(6.35mm) fins — add suffix “–F1”

                                                                     Longitudinal, 0.50”(12.7mm) fins — add suffix “–F2”                   1 up – 2.58¨ x 2.5¨ x 0.62¨ (65,5 x 63,5 x 15,7mm)

           (57,9 x 45,7 x 12,7mm)                                                                                                          2 up – 2.58¨ x 4.9¨ x 0.62¨ (65,5 x 124,5 x 15,7mm)

                                                                                                                                           3 up – 2.58¨ x 7.3¨ x 0.62¨ (65,5 x 185,4 x 15,7mm)

To order the SlimMod configuration add the suffix “–S” to                                                                                                        BusMod

the standard module part number.

Qty (2) grounding clips are included with each SlimMod

P/N 32187

                                                                     Transverse, 0.25”(6.35mm) fins — add suffix “–F3”

                                                                     Transverse, 0.50”(12.7mm) fins — add suffix “–F4”                                     2.28”L x 2.40”W x 1.08”H

                                                                                                                                                            (57,9 x 61,0 x 27,4mm)

                                                                        Available with longitudinal or transverse fins of                         To order the BusMod fully assembled, add suffix “–B1” to

                                                                        0.25”(6.35mm) or 0.50”(12.7mm) height. Add the                            the standard module part number.

                                                                        appropriate suffix to the module part number.

                                                                                                                                                  To order the BusMod separately:

                                                                        Qty (4) grounding clips are included with each FinMod                     Half-sized BusMod — P/N 18952

                                                                        F1, F2 P/N 32185                                                          See BusMod Mechanical Drawings for more details.

                                                                        F3, F4 P/N 32186

VI-J00 DC-DC Converters                                                                           Rev 3.0

Page 6 of 7                                                                                       06/2017
                                                                                                                                       VI-J00, VE-J00

Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and

accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom

power systems.

Information furnished by Vicor is believed to be accurate and reliable.  However, no responsibility is assumed by Vicor for its use.   Vicor

makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication.               Vicor reserves

the right to make changes to any products, specifications, and product descriptions at any time without notice.                        Information published by

Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.

Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty.                   Except where

mandated by government requirements, testing of all parameters of each product is not necessarily performed.

Specifications are subject to change without notice.

Visit http://www.vicorpower.com/vi-200_vi-j00 for the latest product information.

Vicor’s Standard Terms and Conditions and Product Warranty

All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage

(http://www.vicorpower.com/termsconditionswarranty) or upon request.

Life Support Policy

VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE

EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION.                                As used

herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and

whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to

result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform

can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.         Per Vicor Terms

and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies

Vicor against all liability and damages.

Intellectual Property Notice

Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the

products described in this data sheet.    No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property

rights is granted by this document.     Interested parties should contact Vicor’s Intellectual Property Department.

                                          Contact Us: http://www.vicorpower.com/contact-us

                                                      Vicor Corporation

                                                      25 Frontage Road

                                                      Andover, MA, USA 01810

                                                      Tel: 800-735-6200

                                                      Fax: 978-475-6715

                                                      www.vicorpower.com

                                                                         email

                                          Customer Service: custserv@vicorpower.com

                                          Technical Support: apps@vicorpower.com

                         ©2017 Vicor Corporation. All rights reserved. The Vicor name is a registered trademark of Vicor Corporation.

                                     All other trademarks, product names, logos and brands are property of their respective owners.

VI-J00 DC-DC Converters                                                  Rev 3.0

Page 7 of 7                                                              06/2017
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Vicor:

VI-J41-IX  VI-JT3-EW     VI-JT3-CX  VI-J63-IW  VI-JWH-CX  VI-JW1-EY-B1          VI-JWL-EW  VI-JW1-CY     VE-J02-EY-F1

VI-JW2-CW  VI-J60-IW     VI-JT0-CY  VI-J70-CZ  VI-J60-CX  VI-J20-IZ  VI-J53-IW  VI-JW3-IY  VI-J11-IW     VI-J3F-EW     VI-

JN0-EX  VI-J60-CW  VI-J20-MY  VI-JWL-CW        VI-J40-EY  VI-J61-IZ  VI-JW2-IY  VE-J04-EZ  VI-JW0-IZ     VI-J0B-CZ     VI-

J4J-IX  VE-J31-CY  VI-JW1-IW  VE-JV0-CZ     VI-J61-CY     VI-J22-IZ  VI-J60-CY  VE-J72-CY  VI-J3B-CZ     VE-J0Y-IX  VI-

J54-CW-F3  VI-J23-MY     VI-JT3-CY  VE-JW1-CY  VI-J51-CY  VI-J6L-IW  VE-JW0-CY             VI-J53-CY  VI-J22-MZ  VI-J61-

CX  VI-J22-MY  VI-JW2-IZ-F2   VI-J71-CZ  VI-JWL-IW     VI-J61-CZ     VI-JW3-IW  VE-J71-CY  VI-J01-CX     VI-JWL-IZ  VI-

JW1-EW  VI-JWJ-EY     VE-JW3-CY     VI-JW3-CX  VE-JN3-CW  VI-J6L-CZ  VI-J73-EX-B1          VI-J61-CW  VI-J01-EZ-F2     VI-

JWN-CW-F1     VI-J63-EX  VI-JWL-IW-B1    VI-JW1-EZ  VI-J6Y-CW        VI-JT0-IY  VI-JT2-IY  VI-JT3-CW-B1  VE-JWH-CX

VE-JN0-EZ-F1   VI-J6W-EX-F1   VE-J33-EW-B1     VI-J23-CX  VI-J1M-EZ  VI-JW1-EW-B1          VE-JT3-CY-B1  VI-J42-CZ     VI-

J40-CZ  VI-J41-CZ  VI-JW0-CX  VE-J42-CW        VE-J43-CW  VE-J74-EZ  VI-J63-EW  VI-J22-IY  VI-JW1-IY     VE-JWM-EW

VI-J4P-EY-F1   VI-J40-CY-F2   VI-J43-CY-F2     VI-J40-EZ  VI-J70-CY  VI-JTY-CX

小广播

VE-JTN-MX-F2器件购买:

该厂商的其它器件

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved