V600-H12 5M器件文档内容

Cat.No. Z127–E1–1

                   V600 RFID System

                   R/W Heads and

                   SRAM Data Carriers

                   OPERATION MANUAL
V600 RFID System

R/W Heads and SRAM Data Carriers

Operation Manual

Produced August 1998
Notice:

   OMRON products are manufactured for use according to proper procedures by a qualified operator

   and only for the purposes described in this manual.

   The following conventions are used to indicate and classify precautions in this manual. Always heed

   the information provided with them. Failure to heed precautions can result in injury to people or dam-

   age to property.

!  DANGER        Indicates an imminently hazardous situation which, if not avoided, will result in death or

                 serious injury.

!  WARNING       Indicates a potentially hazardous situation which, if not avoided, could result in death or

                 serious injury.

!  Caution       Indicates a potentially hazardous situation which, if not avoided, may result in minor or

                 moderate injury, or property damage.

Product Application

   You must allow sufficient leeway against product ratings and functionality, and provide safety mea-

   sures, such as fail-safe measures, whenever applying the products described in this manual in any of

   the following situations. Always consult with your OMRON representative whenever applying the

   products in any of these situations.

                               • Applications under any conditions or any environments not described in this

                                  manual.

                               • Applications for nuclear power control, railways, aviation, automobiles, fur-

                                  naces, medical equipment, amusement equipment, safety equipment, etc.

                               • Applications that can affect human life or property or that particularly require

                                  safety.

Visual Aids

   The following headings appear in the left column of the manual to help you locate different types of

   information.

                     Note      Indicates information of particular interest for efficient and convenient operation

                               of the product.

                   1, 2, 3...  1.       Indicates lists of one sort or another, such as procedures, checklists, etc.

  OMRON, 1998

   All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any

   form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permis-

   sion of OMRON.

   No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is

   constantly striving to improve its high-quality products, the information contained in this manual is subject to change

   without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no

   responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the informa-

   tion contained in this publication.

                                                                                                                                v
                            TABLE OF CONTENTS

SECTION 1

Features and System Configuration . . . . . . . . . . . . . . . . .                                                                       1

1-1  Features    ...............................................................                                                          2

1-2  System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       3

SECTION 2

Specifications      ...................................                                                                                   5

2-1  R/W Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6

2-2  Data Carriers  ...........................................................                                                           8

2-3  Data Carrier Battery Service Life  ...........................................                                                       12

SECTION 3

Communications Specifications           ....................                                                                              15

3-1  Transmission Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       16

3-2  Transmission Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      17

3-3  Data Carrier Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .     19

SECTION 4

Installation        .....................................                                                                                 21

4-1  R/W Head Installation  ....................................................                                                          22

4-2  Data Carrier Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .      26

SECTION 5

Chemical Resistance         .............................                                                                                 31

Appendices

A Accessories (Sold Separately) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .         33

B Discontinued Models and Replacements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  35

C  Other Series  ...............................................................                                                          49

Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                                        51

                                                                                                                                              vii
About this Manual:

This manual describes the installation and operation of the V600-series Read/Write Heads and battery-

powered SRAM Data Carriers, and includes the sections described below.

Please read this manual carefully and be sure you understand the information provided before attempting

to install and operate the Read/Write Heads and Data Carriers. Keep this manual in a convenient location

where it can continue to be used for reference and guidance.

Section 1 provides general information on features and system configuration.

Section 2 provides specifications for the Read/Write Heads and Data Carriers.

Section 3 provides communications specifications.

Section 4 explains how to install the Read/Write Heads and Data Carriers.

Section 5 provides information on specific chemicals that affect the Read/Write Heads and Data Carriers.

Appendix A provides information on accessories that can be purchased separately.

Appendix B provides information on discontinued models and their replacements.

Appendix C provides information on particular models to be used in England.

! WARNING  Failure to read and understand the information provided in this manual may result in

           personal injury or death, damage to the product, or product failure. Please read each

           section in its entirety and be sure you understand the information provided in the section

           and related sections before attempting any of the procedures or operations given.

                                                                                                          ix
                                               SECTION 1

                                               Features and System Configuration

This section provides a general introduction to the V600 RFID System, including the V600-series Read/Write (R/W) Heads

and Data Carriers. The V600 RFID System utilizes non-contact data transfer in which data is transmitted electromagnetically

without physical contact between the devices.

1-1  Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

1-2  System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .            3

                                                                                                                                                  1
Features                                                                                  Section  1-1

1-1       Features

                         The V600 RFID System offers powerful support to the automation of large-scale

                         distributed control systems and multi-model small-scale production systems by

                         means of contactless data communication.

Contactless Data         Data is transmitted between the Data Carrier (DC) and Read/Write (R/W) Head

Transfer                 electromagnetically in both directions, without physical contact between the two

                         devices.

SRAM Memory              SRAM (static random access memory) is used for the DC’s memory. There is no

                         limit to the number of times that the memory can be accessed for reading or writ-

                         ing data. The memory is powered by a long-life lithium battery.

CRC Error Detection      A 16-bit CRC (Cyclic Redundancy Check) has been added to detect data trans-

                         mission errors in both directions between the ID Controller and R/W Head, and

                         the R/W Head and DC. This feature also helps to ensure superior transmission

                         reliability even in environments where noise tends to occur.

8K-byte Memory           The DCs have an 8K-byte memory. In addition to essential identification data,

                         information on models and test results can be entered on-site.

Long Battery Life        The battery will last eight years in temperatures ranging from –25°C to 70°C

                         (–18°F to 158°F).

Battery Status Checking  The projected battery service life can be easily checked by means of a command

                         from the ID Controller, which simplifies battery maintenance.

Superior Durability and  The R/W Head and DC offer superior resistance to environmental factors such

High Reliability         as vibration, oil, water, and so on.

2
System Configuration                                                                                  Section   1-2

1-2  System Configuration

                                 A V600 RFID System is made up of ID Controllers, R/W Heads, and DCs. A sys-

                                 tem can be assembled to suit almost any situation with different arrangements of

                                 these components.

ID Controllers and ID Sensor Units

V600-CA1A/CA2A                   V600-CA8A/CA9A                   V600-CF1A              V600-CB-S

     100 to 240 VAC              100 to 240 VAC              100 to 240 VAC              Hand-held Model

     Host: RS-232C/RS-422        Host: Parallel PNP/NPN      Host: RS-232C

V600-CD1D-V2                     C500-IDS01-V2                    IDSC-C1DR-A

                                 C200H-IDS01-V1                   IDSC-C1DT-A

     24 VDC                      PLC,  ID Sensor  Units      ID Controllers

     Host: RS-232C

R/W Heads and Data Carriers

                                       V600-H07                                V600-H11

             V600-D8KR12            V600-D8KR13              V600-D8KR04                          V600-D2KR16

                           Note  Refer  to      Appendix  B  for  details  on  the  availability  of  V600-H12     and

                                 V600-D8KR11.

                                                                                                                   3
                                                                                   SECTION 2

                                                                                   Specifications

This section provides Read/Write (R/W) Head and Data Carrier (DC) specifications.

2-1  R/W Heads  .............................................................                                                               6

     2-1-1  Specifications and Outer Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                         6

2-2  Data Carriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8

     2-2-1  Specifications and Outer Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                         8

     2-2-2  Memory Map  ....................................................                                                                10

     2-2-3  Write Protect Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                10

2-3  Data Carrier Battery Service Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .              12

     2-3-1  Battery Service Life Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  12

     2-3-2  Battery Service Life Expectancy Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                           14

                                                                                                                                                5
R/W Heads                                                                                                 Section              2-1

2-1       R/W Heads

2-1-1     Specifications              and Outer Dimensions

V600-H07/V600-H11

              Item                                                              Model

                                                     V600-H07                                   V600-H11

Operating frequency                   530 kHz

Operating temperature                 –25°C to 70°C                             –10°C to 60°C

Storage temperature                   –40°C to 85°C                             –25°C to 75°C

Operating humidity                    35% to 95% RH

Insulation resistance                 50 MΩ min. between cable terminals and case (at 500 VDC)

Dielectric strength                   1,000 VAC 50/60 Hz for 1 minute between cable terminals and case.

Degree of protection (See     note.)  Meets or exceeds IEC60529 IP67 and JEM IP67G standards.

Vibration resistance                  10 to 500 Hz, 1.0 mm in each direction; acceleration: 150 m/s2 (about 15 G); one

                                      sweep in each of three axis directions, three sweeps in 11 minutes

Shock resistance                      500 m/s2 (about 50 G) three times each in X, Y, Z directions, total 18 times

Error detection                       16-bit CRC (Cyclic Redundancy Check) is used in both directions of transmission.

LED indicators                        Power supply: green; communications: orange

Cable length                          Standard lengths of 0.5, 2, 5, and 10 m.

Max. cable length                     30.5 m                                    50.5 m

Weight (approximate)                  1 kg (with 10 m cable)                    650 g (with 10 m cable)

                              Note    The connectors are not waterproof.

V600-H07

                                                                                   Mounting holes (four, 4.5 dia.)

       Power indicator (LED)

   Operation indicator (LED)                                                           Bushing  Vinyl-insulated     Connector

                                                                                                round cord (6 dia)

                                      Case material                                ABS resin

                                      Fill resin                                   Epoxy resin

                                      Cable                                        PVC (oil-resistant)

6
R/W Heads                                                                            Section   2-1

V600-H11

                                              Mounting holes   Vinyl-insulated

                         Four, R1    Two, R5  (Two, 4.5 dia.)  round cord (6 dia)

                                              Bushing                     Connector

                                                                                    14.7 dia.

LED indicators

Power supply (green)

Communications (orange)

                         Case material                         ABS resin

                         Fill resin                            Epoxy resin

                         Cable                                 PVC (oil-resistant)

                                                                                               7
Data Carriers                                                                                           Section      2-2

2-2    Data Carriers

2-2-1  Specifications and Outer Dimensions

V600-D8KR12/13/04

             Item                                                   Model

                                 V600-D8KR12                        V600-D8KR13                         V600-D8KR04

Memory capacity            8K bytes

Memory type                SRAM (static random access memory)

Battery service life       Refer to the graphs in 2-3 Data Carrier Battery Service Life.

Number of data read/write  No limit (up to the extent of the battery service life)

conversions

Error detection            16-bit CRC error detection is used in both directions of transmission.

Operating temperature      Data retention: –40°C to 70°C; read/write: –25°C to 70°C

Storage temperature        –40°C to 70°C

Operating humidity         35% to 95% RH

Degree of protection       Meets or exceeds IEC60529 IP67 standards and JEM IP67G standards.

Vibration resistance       10 to 500 Hz, 1.0 mm in each direction; acceleration: 150 m/s2 (about 15 G); one sweep

                           in each of three axis directions, three sweeps in 11 minutes

Shock resistance           1,000 m/s2 (about 100 G) three times each in X, Y, Z directions, total 18 times

Weight (approximate)       70 g                   70 g                                           160 g

   V600-D8KR12                                    V600-D8KR13

                                 Mounting holes                                                         Mounting holes

                                 (Two, 4.5 dia.)                                                        (Two, 4.5 dia.)

   V600-D8KR04

                                                  Mounting holes

                                                  (Four, 4.5 dia.)

                                 Case material                                      ABS resin

                                 Fill resin                                         Epoxy resin

8
Data Carriers                                                                                       Section        2-2

               !  WARNING  The SRAM-type Data Carrier has a built-in lithium battery which can combust or

                           explode if mishandled. Do not disassemble the Data Carrier, or subject it to high

                           pressure  or   high    temperatures   (of   100°C     or     more),  or  dispose    of  it  by

                           incineration.

V600-D2KR16

                                            Item                                        V600-D2KR16

                           Memory capacity                       2K bytes

                           Memory type                           SRAM (static random access memory)

                           Battery service life (See note 1.)    2 years (replaceable battery)

                           Number of data read/write             No limit (unrelated to battery service life)

                           conversions

                           Error detection                       16-bit CRC error detection is used in both

                                                                 directions of transmission.

                           Operating temperature                 Data retention: –15°C to 70°C; read/write: 0°C

                                                                 to 50°C

                           Storage temperature                   –15°C to 70°C

                           Operating humidity                    35% to 85% RH

                           Degree of protection (See note 2.)    IEC60529 IP50 standards

                           Vibration resistance                  10 to 150 Hz, 1.5 mm in each direction;

                                                                 acceleration: 100 m/s2 (about 10 G); for 30 min.

                                                                 each in X, Y, Z directions.

                           Shock resistance                      300 m/s2 (about 30 G) three times each in X, Y,

                                                                 Z directions, total 18 times

                           Weight (approximate)                  15 g

                  Note     1. This is the battery service life when the battery is used in an environment

                           with an ambient temperature below 25°C. For the relationship between tem-

                           perature and battery service life, refer to 2-3 Data Carrier Battery Service

                           Life.

                           2. When the accessory battery replacement cover seal is in place.

V600-D2KR16                                           Special-purpose Holder (V600-A81)

Four, R1.5

                                                                                        Eight, R0.5

                                                                      (Four, 3.5 dia.)

                                                               (Four, 5.5 dia.)

                                                      Two, R2.5

                           Case material: ABS resin

               !  WARNING  The SRAM-type Data Carrier has a built-in lithium battery which can combust or

                           explode if mishandled. Do not disassemble the Data Carrier, or subject it to high

                           pressure  or   high    temperatures   (of   100°C     or     more),  or  dispose    of  it  by

                           incineration.

                                                                                                                       9
Data Carriers                                                                                                     Section  2-2

2-2-2  Memory Map

                                  The Data Carrier (DC) has a memory area of up to 8K bytes. Each address of the

                                  memory area specifies one byte. A single byte of data can be written to one

                                  address.

                                                           Address                       Data

                                                           0000H                     Production date area

                                                           0001H

                                                           0002H

                                                              to                  Write protect setting area

                                                           0005H

                                                           0006H

                                                              to                                   to

                                                           00FFH

                                                           0100H

                                              8K              to                                   to

                                                           01FFH

                                                              to                                   to

                                                           0700H

                                                              to                                   to

                                                           1FFFH

                                                                             Leftmost    digit         Rightmost  digit

                                                                                                1  byte

Production  Date  Area  (Written  by Maker)

                                  Address                                    Bit

                                                  7        6      5       4       3  2          1      0

                                  0000H           Month (10s digit)          Month (1s digit)

                                  0001H           Year (10s digit)           Year (1s digit)

                        Note      1. Address  0000   contains        the     month   of  production       (March→“03,”     Octo-

                                  ber→“10”).

                                  2. Address 0001 contains the lower two digits of the year (1997→“97”).

                                  3. This area is read only.

                                  The memory is SRAM, so there is no limit on the number of times that data can

                                  be read or overwritten.

                                  The memory capacity is 8 KB, and the available addresses are 0000H to 1FFFH.

                                  The memory contents are preserved by a long-life lithium battery.

2-2-3  Write      Protect  Function

                                  The write protect function protects important data stored in the memory of the

                                  Data Carrier, such as product number and model, from being overwritten inad-

                                  vertently. With this function, the data in a specified memory area can be pro-

                                  tected. It is recommended that important data be write-protected as follows:

Setting the Write Protect Function

                                  The write protect function is set in the four bytes of addresses 0002H through

                                  0005H of the Data Carrier’s memory. The status of the leftmost bit of address

                                  0002H determines whether or not the write protect function is in effect.

10
Data Carriers                                                                                        Section          2-2

When Executing the               Address                                           Bit

Write Protect Function                           7           6        5         4       3         2  1                0

                                 0002H         YES/     Leftmost two digits of beginning address

                                               NO

                                 0003H         Rightmost two digits of beginning address

                                 0004H         Leftmost two digits of ending address

                                 0005H         Rightmost two digits of ending address

                                 The region specified by the beginning and ending addresses will be protected

                                 when the write protect control bit (leftmost bit of address 0002H) is ON, as shown

                                 in the following table.

                                 Leftmost bit of             Write Protect Function

                                      0002H

                                 ON                  Data is write-protected.

                                 OFF                 Data is not write-protected.

                                 Area that can be set:

                                 Beginning address:             0006H to 1FFFH

                                 Ending address:                0006H to 1FFFH

Examples

                    1,  2, 3...  1.  The following settings would write-protect addresses 0015H through 0120H

                                     (i.e., the beginning address to the ending addresses):

                        Address                    Bit                   Address
                                                                         ÉÉÉÉÉÉ 0015H
                                     7  6     5  4   3    2     1  0     0000H

                        0002H        1  0     0  0   0    0     0  0     ÉÉÉÉÉÉ to

                                           8                 0           ÉÉÉÉÉÉÉÉÉÉÉÉ 0120H          Write-protected

                        0003H        0  0     0  1   0    1     0  1                                 addresses

                                           1                 5

                        0004H        0  0     0  0   0    0     0  1

                                           0                 1           1FFFH

                        0005H        0  0     1  0   0    0     0  0

                                           2                 0

                                 2.  To write-protect only 1 byte, set the same address as the start and ending

                                     addresses (beginning address = ending address).

                                      Address

                                     ÉÉÉÉÉ 1 byte                     Write-protected address

                                 3.  If the ending address exceeds the last address of the Data Carrier memory

                                     (ending address > 1FFFH), the addresses up to 1FFFH will be write-pro-

                                     tected:.

                                      Address

                                      0000H

                                      1FFFHÉÉÉÉÉÉÉÉÉÉ                 Write-protected addresses

                                 4.  If the beginning address is greater than the ending address (beginning

                                     address > ending address), the write-protected area will wrap through

                                     0006H, so that addresses from 0006H through the ending address,and from

                                     the beginning address through 1FFFH will be write-protected.

                                                                                                                         11
Data Carrier Battery Service Life                                                                                                 Section  2-3

                                                             ÉÉÉÉÉ 0006HAddress

                                                             0000H
                                                             ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ 1FFFH
                                                                                                    Ending address

                                                                                                    Beginning address

Canceling Write Protection

                                                        To cancel write protection, turn OFF the leftmost bit of address 0002H. The write

                                                        protection will be cancelled, and the beginning and ending addresses that are

                                                        set for 0002H to 0005H will be ignored.

2-3    Data Carrier Battery Service Life

2-3-1  Battery                              Service Life Factors

                                                        The Data Carrier has a built-in lithium battery that provides power. The service

                                                        life of the battery depends on the number and size of data transmissions. The

                                                        graphs below show the relationship between daily number and size of transmis-

                                                        sions and battery service life. (The illustrations shown here are representative

                                                        examples.)

       V600-D8KR12                                                                   V600-D8KR13

       100                                                                           100

       x                                                     5 years                 x

       transmissions                                                                 transmissions           5 years

                                                    8 years

       of                                                                            of             8 years

       number                                                                        number

       Daily                                                                         Daily

                                            Number  of  bytes/transmission                          Number of bytes/transmission

       V600-D8KR04

       Daily number of transmissions x 100                          5  years

                                                        8    years

                                            Number of bytes/transmission

                                                        The preceding graphs show the lowest possible lifetimes for DCs in the tempera-

                                                        ture range –10°C to 55°C (14°F to 131°F). Normally, batteries will last longer at

                                                        lower ambient temperatures.

12
Data Carrier  Battery  Service  Life                                                             Section  2-3

                                With a V600-D8KR04 DC at 55°C (131°F), for example, 200 bytes of data can be

                                accessed 3,000 times a day for 8 years or 6,500 times a day for 5 years.

                                With a V600-D8KR12 DC at 55°C (131°F), 40 bytes of data can be accessed

                                2,000 times a day for 8 years or 4,500 times a day for 5 years.

V600-D2KR16                     The battery used for the V600-D2KR16 has a service life of 2 years at an ambi-

                                ent temperature of 25°C, regardless of the number of access times or R/W

                                bytes.

                                                 Battery Service Life vs. Temperature

                                                 Battery life (years)

                                                                       Ambient temperature (°C)

                                The above graph shows the relationship between the service life of a built-in bat-

                                tery and ambient temperature (after the insulation sheet is removed). The table

                                below shows the life expectancy of a battery that is stored separately (without

                                being installed in the DC).

                                Temperature     Battery consumption rate (%) per year

                                20           1

                                30           2

                                40           4

                                50           8

                                60           16

                                70           32

                                If the DC is kept at a temperature of 70°C without removing the insulation sheet,

                                the battery will last for 1.36 years (2 years x (1 – 0.32)). Furthermore, if the DC is

                                kept for one year at a temperature of 70°C without removing the insulation sheet,

                                the battery will last for an additional period of approximately 1.4 years if used at

                                an ambient temperature of 25°C. The life of the battery will be shorter if used at

                                an ambient temperature of 0° or 50°C.

                       Note     1. The data in the V600-D2KR16 will be lost at the time of battery replacement.

                                    Be sure to make a backup of the data before replacing the battery.

                                2. After replacing the battery, be sure to affix the battery cover seal. IP50 is not

                                    guaranteed if the battery cover seal is not affixed.

                                                                                                                        13
Data Carrier Battery Service Life                                                          Section  2-3

2-3-2    Battery Service Life Expectancy Check

Checking Whether the Battery is Low

Models With Built-in Battery (Except V600-D2KR16)

                   1, 2, 3...  1. Data Carrier battery checks are not performed automatically, only during

                                   times of special access.

                                   When a battery check is performed, a small current is passed through the

                                   DC’s internal circuitry. Too much power would be consumed if a battery

                                   check was performed automatically every time DC memory was accessed.

                                   Incorporate a routine once-a-day check when creating the system program.

                               2. Access for checking whether the battery is low is only enabled when the two

                                   bytes of data from address 0000H to 0001H are read.

                                   Use one of the following commands to check the battery status. (The CR at

                                   the end of each command means carriage return.)

                                   a)  Read command: RD H/A 1 0000 02*CR

                                   b)  Auto Read command: AR H/A 1 0000 02*CR

                                   c)  Polling Auto Read command: PR H/A 1 0000 02*CR

                               3. If the end code of the response is 00, the battery is operating normally. If the

                                   end code is 7B, the battery is low. The following are responses to Read and

                                   Auto Read commands sent to a DC with a good battery:

                                       RD 0 0        0997*

                                       AR 0 0        0997*

                               Normal end code               Read data

                                                             Production date: Sept., 1997

                                   The following are responses to Read and Auto Read commands sent to a

                                   DC with a low battery:

                                             RD 7 B  0997*

                                             AR 7 B  0997*

                               Low battery end code          Read data

                                                             Production date: Sept., 1997

                         Note  With the V600-D2KR16 (replaceable-battery model), read/write commands are

                               executed without regard to addresses.

Service  Life  of  Data  Carriers After the Battery-low Code is Generated

                               Under ordinary operating conditions the DC can be used for about one month

                               after a low battery end code is received. However, it is recommended that the DC

                               be replaced with a new one as soon as possible.

                               The V600-D2KR16 (replaceable-battery model) can be used for approximately

                               two weeks under normal operating conditions, but it is recommended that the

                               battery be replaced with a new one as soon as possible.

                         Note  The DC (except for the V600-D2KR16, SRAM memory model) contains a thionyl

                               chloride-type lithium battery. One characteristic of this type of battery is its ten-

                               dency to develop a higher internal resistance when it is not used. If the battery

                               isn’t used for several months, the internal resistance can increase enough to

                               cause a low battery response, even if the battery is good.

                               Consequently, after several months of disuse it is recommended to transmit data

                               to/from the DC for about 10 minutes to “warm up” the battery and decrease its

                               internal resistance. This operation will have almost no effect on the useful life of

                               the battery.

14
                                                          SECTION 3

                                                          Communications Specifications

This section provides specifications for communications.

3-1  Transmission Range  ......................................................                        16

     3-1-1  Transmission Range Specifications (Certified Performance) . . . . . . . . . . . . . . . .  16

     3-1-2  Transmission Areas  ...............................................                        17

3-2  Transmission Time   .......................................................                       17

3-3  Data Carrier Speed  .......................................................                       19

                                                                                                           15
Transmission Range                                                                                              Section    3-1

3-1       Transmission Range

3-1-1     Transmission Range Specifications (Certified Performance)

R/W Head              Setting conditions                     Transmission range (unit: mm, axis slip:           ±10 mm)

                                                      V600-D8KR12          V600-D8KR13         V600-D8KR04      V600-D2KR16

V600-H07  Stationary  Flush-mounted within metal      10 to 50             10 to 30            See page 28.     ---

                      Surface-mounted on metal        10 to 60             10 to 35            10 to 100        ---

          Moving      Flush-mounted within metal      25 to 50             20 to 30            See page 28.     ---

                      Surface-mounted on metal        25 to 60             20 to 35            50 to 100        ---

V600-H11  Stationary  Flush-mounted within metal      5 to 40              10 to 30            See page 28.     2 to 15

                      Surface-mounted on metal        5 to 45              10 to 30            10 to 65         2 to 15

          Moving      Flush-mounted within metal      25 to 40             15 to 30            See page 28.     6 to 15

                      Surface-mounted on metal        25 to 45             15 to 30            30 to 65         10 to 15

                      Note      1. These specifications are the certified performance when taking into consid-

                                       eration variations in ambient temperatures and products.

                                2. The read range and the write range are the same.

                                3. The Data Carrier and Read/Write Head installation conditions are as fol-

                                       lows:

1) V600-D8KR12, V600-D8KR13 Data Carriers

                                                    Read/Write Head        Data carrier

                                          Steel                                    Metal                  Metal

                                                             Surface-mounted on metal          Flush-mounted within metal

2) V600-D8KR04 Data             For flush-mounting within metal, the read/write distance changes depending                 on

Carriers                        distance x from the metal.

                                              x mm                   x mm

                                                    Flush-mounted                              Surface-mounted

                                                                               20  mm    max.

                                                      Metal                                    Metal

                                              Flush-mounted within metal                       Surface-mounted on metal

3) V600-D2KR16 Data   Carriers

                                          10 mm min.               10 mm min.

                                                    Data carrier                               Data carrier

                                                      Metal                5 mm max.                     Metal

                                                                           (see note)

                                              Flush-mounted within metal                       Surface-mounted on metal

                                For details regarding R/W Head and DC installation, refer to Section 4 Installa-

                                tion.

16
Transmission Time                                                          Section          3-2

3-1-2  Transmission Areas

                   The following diagrams show representative examples of the communications

                   areas. All measurement units are shown in mm.

     V600-D8KR12 and V600-H07          V600-D8KR12 and V600-H11

     V600-D8KR13 and V600-H07          V600-D8KR13 and V600-H11

     V600-D8KR04 and V600-H07                    V600-D8KR04 and V600-H11

     V600-D2KR16 and V600-H11

                                 Note            The mounting method is surface-mounted on

                                                 metal in all cases.

3-2    Transmission Time

Transmission Time  Transmission times are the same for all models of R/W Heads and DCs covered

                   in this manual, although transmission times are different for DCs that contain

                   batteries. The term “transmission time” is used to indicate both the turn-around

                   time (TAT) and the lower level transmission time between the R/W Head and DC.

                   The TAT is the total time required from the transmission of a command from a

                   host device (such as a host computer) until the reception of a response at the

                   host device.

                   The lower-level transmission time is the time required for transmission of data

                   between the R/W Head and DC.

                                                                                                     17
Transmission Time                                                                                                 Section  3-2

                          The following diagram shows the TAT and lower-level transmission time for the

                          READ command.

                                 RDH1.   ...... *↵

                                                                                                     RD001122 . . . * ↵

                                                                             Lower-level

                                                                             transmission time

                                                                             Turn-around time (TAT)

TAT (Reference)           The following diagrams show the TAT and lower-level transmission time for

                          V600-CA1A, V600-CA2A, V600-CD1D-V2, and V600-CF1A Serial Interface ID

                          Controllers. (The TAT for Parallel Interface ID Controllers and ID Sensor Units

                          varies with the host’s software.)

                                         Turn-around time (ms)               (Auto) write

                                                                                           (Auto) read

                                                                             Number of bytes processed

                          Calculation Method (Reference)                                                     (Unit: ms)

                                 Read/Write                                                                  TAT

                          Read                                                             T = 2.9N + 69.8

                          Write                                                            T = 5.3N + 105.6

                          N: Number of bytes processed

                    Note  1. The value given for the TAT data assumes that the communications settings

                          for the V600-CA1A ID Controller are as follows:

                          Baud rate: 9600 bps; data length: 8 bits; stop bits: 1; parity: odd.

                          2. The number of bytes is the number for ASCII code. (For details, refer to the

                          RFID System Operation Manual (Z83).

Transmission  Time  With the Data Carrier (Reference)

                                         Lower-level transmission time (ms)  (Auto) write

                                                                                           (Auto) read

                                                                             Number of bytes processed

18
Data Carrier Speed                                                                       Section         3-3

                           Calculation Method (Reference)                                (Unit: ms)

                                      Read/Write                      Lower-level transmission time

                           Read                                     T = 1.8N + 48.4

                           Write                                    T = 4.2N + 86.5

                           N: Number of bytes processed

3-3  Data Carrier          Speed

                           The number of bytes that can be processed using the Auto Read and Auto Write

                           commands depends on the speed of the DC. The relationship between the num-

                           ber of bytes and DC speed in m/minute can be determined from the following

                           equation.

                           Max. DC Speed =       Distance travelled in the transmission range (m)

                                                    Lower-level transmission time (min)

                           • The “distance travelled in the transmission range (m)” is the maximum width of

                           the transmission range (in the X direction). Refer to the diagrams in 3-1 Trans-

                           mission Range.

                           • The “lower-level transmission time (min)” is the time required for transmission

                           between the DC and the R/W Head. For details regarding this calculation, refer

                           to 3-2 Transmission Time.

Calculation Example        In this example diagram, the V600-D8KR04 and V600-H07 are combined and

                           four bytes are read.

                                                              110 mm

                           This diagram shows the following:

                           Distance travelled in transmission range, Y (transmission distance) = 110 mm

                           Lower-level transmission time, T = 1.8 x 4 + 48.4 = 55.6 ms.

                           Accordingly, the DC speed in this case will be as follows:

     Max. DC Speed =       Distance travelled in the transmission range (m)   =  110 (mm)

                               Lower-level transmission time (min)                   55.6 (ms)

                                                                              = 118.7 m/min

                     Note  1.  The distance travelled in the transmission time will vary depending on the

                               read/write distance and the shaft slippage. Refer to the diagrams in 3-1

                               Transmission Range.

                           2.  The DC speed is the standard value. Before using the equipment, run a test

                               to determine the speed under the actual operating conditions.

                           3.  The DC speed data above do not take into account possible transmission

                               errors in host or lower-level communications.

                           4.  When the V600-CA8A/CA9A is used, the speed will vary depending on the

                               software at the host device.

                                                                                                              19
                                                                                                SECTION 4

                                                                                                                                      Installation

This section describes the recommended installation methods for the R/W Heads and Data Carriers (DCs), and provides

details on the battery’s service life expectancy and methods to check the battery’s condition.

4-1  R/W Head Installation  ....................................................                                                      22

     4-1-1  Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       22

     4-1-2  Effect of Surrounding Metals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .              23

     4-1-3  Interference between R/W Heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  24

     4-1-4  Interference with Proximity Sensors  ..................................                                                   25

4-2  Data Carrier Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26

                                                                                                                                          21
R/W Head Installation                                                             Section           4-1

4-1       R/W Head      Installation

4-1-1     Installation  Method

V600-H07 R/W Head

                               Use M4 screws and spring washers (in four places) for R/W Head installation.

                               Tighten the screws to a torque of 0.7 to 1.2 NSm (approximately 7 to 12 kgfScm).

                               There are no restrictions on the mounting direction or the direction of access to

                               the DC, but if the R/W Head is to be installed near a device such as a conveyance

                               belt, make sure there is no danger of the R/W Head being accidentally struck.

                                                          100            Four, M4

                                                         90±0.2          mounting holes

                                                                                  100

                                                                         90±0.2

Mounting  Bracket  Dimensions  (V600-H07  Only)

                                                 100±0.2         Four, C1 corners

                                                 90±0.1

                                                                         100±0.2

                                                                 90±0.1

                                                                 Four,   4.5  +0.5  mm-dia.  holes

                                                                              –0

22
R/W Head Installation                                                                               Section        4-1

                          Note  A mounting bracket is provided with the V600-H07. It is not necessary to use this

                                bracket if a metal mounting plate larger than the 100×100 mm “footprint” of the

                                R/W Head is used for installation.

                                                                                  Mounting plate

                                               V600-H07

                                                                                  Mounting bracket

                                                                                  (included with V600-H07)

       !           Caution      Be   sure  to  ground the  mounting  surface  of  the R/W Head if it is metal.

V600-H11 R/W Head

(1) Front Panel Mounting

                                                                                  Two, M4

                                                                     Coil center  mounting holes

2) Rear Panel Mounting          Insert the nuts that are included with the R/W Head into the locations marked “A.”

                                                                                  Coil center       Two, 4.5 dia.

                                Nut

4-1-2  Effect of        Surrounding Metals

V600-H07 R/W Head               In addition to surface mounting, it is also possible to flush-mount the V600-H07

                                within a metal casing to protect it from being struck by other objects. To prevent

                                malfunctioning, allow at least 50 mm between the sides of the R/W Head and the

                                metal casing, and do not mount the R/W Head below the metal surface. If the

                                                                                                                    23
R/W  Head  Installation                                                                                              Section  4-1

                                 gap between sides of the R/W Head and the metal casing is less than 50 mm, the

                                 read/write transmission range will be greatly diminished.

                                                                                                 (Unit: mm)

           30 mm max.                                                                50 mm min.

                                              11 mm        Metal casing

                                              radius min.

                   Metal casing                                          50 mm min.                           50 mm

                                                                                                                     min.

                                  50 mm min.                                         50 mm min.

                         Note     1. Do not bend the R/W Head’s cable into a curve tighter than 11 mm in radius.

                                  2. The read/write transmission range will be reduced significantly if the R/W

                                  Head is installed closer than 50 mm to metal surfaces.

V600-H11  R/W Head               In addition to surface mounting, it is also possible to flush-mount the V600-H11

                                 within a metal casing to protect it from being struck by other objects. To prevent

                                 malfunctioning, allow at least 30 mm between the sides of the R/W Head and the

                                 metal casing, and do not mount the R/W Head below the metal surface. If the

                                 gap between sides of the R/W Head and the metal casing is less than 30 mm, the

                                 read/write transmission range will be greatly diminished.

                                                                                                 (Unit: mm)

           23 mm max.                                                                30 mm min.

                                              11 mm        Metal casing

                                              radius min.

                    Metal casing                                         30 mm min.

                                  50 mm min.                                         30 mm min.  30 mm  min.

                         Note     1. Do not bend the R/W Head’s cable in a curve tighter than 11 mm in radius.

                                  2. The read/write transmission range will be reduced significantly if the R/W

                                  Head is installed closer than 30 mm to metal surfaces.

4-1-3     Interference   between R/W Heads

                                 When using two or more R/W Heads, be sure to allow enough space between

                                 the R/W Heads to avoid errors caused by mutual interference. The diagrams

                                 below show the minimum spacing required.

V600-H07 R/W Head                When facing each other, V600-H07 R/W Heads should be installed at least 650

                                 mm apart if RD/WT commands are used, and 900 mm apart if auto commands

                                 are used.

24
R/W Head Installation                                                                Section  4-1

                             When facing the same direction, V600-H07 R/W Heads should be installed at

                             least 550 mm apart (center to center) if RD/WT commands are used, and1,200

                             mm apart (center to center) if auto commands are used.

                                               550 mm min.

                                               (1,200 mm min.)

       650 mm min.

       (900 mm min.)

V600-H11 R/W Head            When facing each other, V600-H07 R/W Heads should be installed at least 200

                             mm apart regardless of whether RD/WT commands or auto commands are

                             used.

                             When facing the same direction, V600-H07 R/W Heads should be installed at

                             least 200 mm apart regardless of whether RD/WT commands or auto com-

                             mands are used.

                                               200 mm min.

       200 mm min.

                       Note  For applications in which no two R/W Heads transmit or receive data at the same

                             time (i.e., in which the R/W Heads read and write independently), there is no risk

                             of mutual interference and the R/W Heads can be installed in proximity. Trans-

                             mission and reception in this case refer to the R/W Heads oscillating after receiv-

                             ing commands.

4-1-4  Interference    with Proximity Sensors

                             V600-series R/W Heads use electromagnetic linking (frequency: 530 kHz), so, if

                             they are installed near sensors (such as proximity sensors) with an oscillation

                             frequency of 400 to 600 kHz, it may cause the sensors to malfunction. Before

                             installing R/W Heads, and when selecting sensors, be sure to conduct tests to

                             make sure that there will be no interference.

V600-H07 R/W Head            As shown in the following diagrams, a V600-H07 R/W Head should be at least

                             400 mm from a proximity sensor when the two are facing the same direction or

                                                                                                                  25
Data  Carrier Installation                                                                           Section   4-2

                                     perpendicular.  When  the  two  are facing    each other, they  should be at least 300

                                     mm apart.

                             Proximity

                             sensor

                                                                                   300 mm min.

                                                                        Proximity

                                                                        sensor

                             400 mm min.

                                                                                                     V600-H07

          400 mm min.

          Proximity

          sensor

V600-H11  R/W  Head                  As shown in the following diagrams, a V600-H11 R/W         Head should be at least

                                     100 mm from a proximity sensor regardless of whether       the two are parallel, per-

                                     pendicular, or facing each other.

                             Proximity

                             sensor

                             100 mm min.                             Proximity     100 mm min.

                                                                     sensor

               100 mm  min.

                                                                                                     V600-H11

               Proximity

               sensor

4-2       Data Carrier Installation

V600-D8KR12/KR13/KR04 Data Carriers

Installation Method                  Use M4 screws and spring washers for DC installation. Tighten the screws to a

                                     torque of 0.7 to 1.2 NSm (approximately 7 to 12 kgfScm).

26
Data  Carrier Installation                                                                            Section          4-2

                            There are no restrictions  on  the           mounting direction  or  the  direction with respect

                            to the R/W Heads.

      V600-D8KR12                                                        V600-D8KR13

                            Two, M4                                                                   Two, M4

      V600-D8KR04

                            Four, M4

Mounting in Metal Casing

                            V600-D8KR12

                            ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ Flush-mounted               ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ 15 mm max.
                                                                                                 Surface-mounted

                                         Metal                                                        Metal

                            V600-D8KR13

                            ÉÉÉÉÉÉÉÉÉFÉÉÉlushMÉÉÉ-emtaoÉÉÉlunteÉÉÉd ÉÉÉ                          Surface-mounted

                                                                         10 mm max. ÉÉÉÉÉÉÉÉÉÉMetaÉÉl ÉÉÉÉ

                            The V600-D8KR12 and V600-D8KR13 DCs can be either surface-mounted or

                            flush-mounted. When flush-mounted in metal, the top of the DC must not be

                            lower than the surface of the metal casing.

                            V600-D8KR04

                            x (mm)                         x (mm)

                                     Flush-mounted                                               Surface-mounted

                                                                         20 mm max.

                                         Metal                                                        Metal

                            Flush-mounted in metal casing                                    Surface-mounted on metal

                                                                                                                       27
Data    Carrier Installation                                                                                  Section            4-2

                                              When the V600-D8KR04             is flush-mounted in a metal casing, the transmission

                                              range varies according to        the width of the gap (x) between the metal and the DC,

                                              as shown in the following        graphs.

        When Combined With V600-H07                                            When Combined With V600-H11

                                       (Shaft slip: ±0 mm)                                       (Shaft slip: ±0 mm)

        (mm)                                                                   (mm)

        range                                                                  range

        Transmission                R/W Head  DC                               Transmission

                                                                                             R/W Head         DC

                                              (over 100 mm)                                                   (over 100 mm)

                      Gap between R/W  Head   and metal (x)                                  Gap between R/W Head and metal (x)

Effect  of            Misalignment            The transmission range will be reduced if the R/W Head does not face the DC

                                              directly when data is transmitted. Try to keep any misalignment below 10°, as

                                              shown in the following diagram.

                                                             Correct                         Incorrect

                                                                                                              This angle should

                                                                                             DC  θ            not exceed 10°.

                                                                DC

                                                             Read/Write Head                 Read/Write Head

V600-D2KR16 Data Carriers

Installation Method                           Use a special-purpose holder (purchased separately) for installation. First

                                              secure the holder with flat countersunk-head screws in at least two places, and

                                              tighten the screws to a torque of 0.3 to 0.5 NSm (approximately 3 to 5 kgfScm).

                                              Then insert the DC into this holder by hand.

                                              Be sure to attach the battery cover seal to the back of the DC. If this seal is not

                                              affixed, the IP protective structure standards will not be satisfied.

                                                             (Four, 3.5 dia.)

                                              (Four, 5.5 dia.)

28
Data Carrier Installation                                                            Section               4-2

Mounting in a Metal           The V600-D2KR16 can be either surface-mounted or flush-mounted in a metal

Casing                        casing. If mounted as shown in the following diagrams, there will be no effect on

                              the transmission range.

                              Flush-mounted                                      Surface-mounted

                              10 mm min.                10 mm min.

                                                                    5 mm max.

                                          Data carrier              (See note.)     Data carrier

                                          Metal casing                              Metal casing

                              Flush-mounted in metal casing                      Surface-mounted on metal

                        Note  When the special-purpose holder is used, this becomes 9 mm max.

Effect of Misalignment        The transmission range will be reduced if the R/W Head does not face the DC

                              directly when data is transmitted. Try to keep any misalignment below 10°, as

                              shown in the following diagram.

                              Correct                               Incorrect

                                                                    DC               This angle should

                                                                                 θ   not exceed 10°.

                              DC

                              Read/Write Head                       Read/Write Head

                                                                                                                 29
                                                                           SECTION 5

                                                                           Chemical Resistance

This section shows the chemicals that affect R/W Heads and Data Carriers.

                                                                           31
Chemical Resistance                                                                                 Section 5

                               R/W Heads and Data Carriers are constructed using both ABS resin and epoxy

                               resin. Referring to the following charts, be sure to use only those chemicals that

                               have no effect on the ABS or epoxy resins and avoid using those chemicals that

                               do have an effect.

                               Applications requiring explosion-proof capability are not possible.

Chemicals that Cause Warping, Cracking, Etc.

              Affecting ABS                                                  Affecting Epoxy

Trichlene, acetone, xylene, toluene, gasoline, creosol,     Aqua regia, chromic acid, sulfuric acid (90% RT), nitric

methylene chloride, phenol, cyclohexane, aqua, regia,       acid (60% RT), ammonia solution, acetone, methylene

chromic acid, sulfuric acid (90% RT), methyl ethyl ketone,  chloride, phenol, trichlene

aniline, nitrobenzene, monochlorobenzene, pyridine, nitric

acid (60% RT), formic acid (80% RT)

Chemicals that May Cause Discoloring, Swelling, Etc.

              Affecting ABS                                                  Affecting Epoxy

Hydrochloric acid, alcohol, Freon, sodium hydroxide,        Sulfuric acid (10% RT), nitric acid (10% RT), hydrochloric

hydrogen peroxide, benzine, sulfuric acid (10% RT), nitric  acid (30% RT), acetic acid (50% RT), calcium hydroxide,

acid (10% RT), phosphoric acid (85% RT), ammonia            benzine, creosol, alcohol, cyclohexane, toluene, xylene,

solution                                                    benzine, grease

Chemicals that Have No Effect

                     ABS                                                                 Epoxy

Ammonia, kerosine, mineral oil, developer, Yushiroken       Ammonia, hydrochloric acid (10% RT), potassium

S50, Chemi-Cool Z, Velocity No. 3, Yushiroken EEE-30Y,      hydroxide, petroleum, gasoline, Yushiroken S50,

petroleum, grease acetate, calcium hydroxide, phosphoric    Chemi-Cool Z, Velocity No. 3, Yushiroken EEE-30Y

acid (30% RT), hydrochloric acid (10% RT), potassium

hydroxide

           !  Caution          The test results listed were obtained at room temperature (approximately 23°C).

                               Some of the chemicals listed as having no effect may cause problems at higher

                               or lower temperatures.

32
                                       Appendix A

                                 Accessories (Sold Separately)

Item                                   Specification   Model     Remarks

Extension cable for R/W   Heads  3m                    V600-A45  The connectors are not

                                 5m                    V600-A44  waterproof.

                                 10 m                  V600-A40

                                 20 m                  V600-A41

                                 30 m                  V600-A42

Extension cable for R/W   Heads  3m                    V600-A56  The connectors are not

                                 5m                    V600-A55  waterproof.

                                 10 m                  V600-A50

                                 20 m                  V600-A51

                                 30 m                  V600-A52

Special-purpose holder           For V600-D2KR16 only  V600-A81  Secured with M3 flat

                                                                 countersunk-head screws

                                                                 (in at least two places).

Lithium battery (CR2016)         For V600-D2KR16 only  V600-A82  CR2016 commercially

                                                                 available, with battery

                                                                 cover tool.

                                                                                            33
                          Appendix B

                    Discontinued Models and Replacements

Discontinued Models

V600-H6

V600-D2KR01, V600-D8KR01

V600-D2KR02. V600-D8KR02

V600-D2KR03, V600-D8KR03

Replacement Models

V600-H12, V600-H11

V600-D8KR11

V600-D8KR12

V600-D8KR13

OMRON appreciates your continued patronage. In October, 1994, it was announced that production of the

500-kHz-frequency wireless transmission models in the V600-series RFID System would be discontinued in

March of 1996. The following information is an update on the models that will be discontinued and the models that

will replace them.

Background

• In 1988, OMRON began development and production of the V600-series RFID System in response to customer

requests, and provided a line of products in this series.

• Systems such as the V600-series RFID System which use electromagnetic linking are required to be in com-

pliance with laws regulating radio wave transmissions. Within Japan there is no particular problem for ID makers

as long as they can demonstrate that they satisfy the prescribed values in the radio wave regulations. And prod-

ucts used in the United States, for example, must receive certification from the Federal Communications Com-

mission (FCC). Accordingly, OMRON received FCC certification for the V600 Series in 1989.

• Subsequently, however, the FCC rules were revised, and models using a frequency of 500 kHz for wireless

transmission between read/write heads and data carriers could not be newly sold or delivered (including installa-

tion) in the United States as of June 23, 1994.

OMRON’s Response

• In response to the above problem, OMRON changed the frequency for all new wireless-transmission products in

the V600 Series from 500 kHz to 530 kHz, and in 1991 received formal certification from the FCC. Since then, all

subsequent models in this series have also been developed for 530-kHz specifications.

• Taking into consideration the maintenance and support of existing 500-kHz models from June 23, 1994,

onwards, the models that OMRON introduced in April, 1994, are completely interchangeable with the earlier

models in all respects (such as shape, installation, etc.) except for transmission frequency.

Advantages for Customers

Standardizing all of the V600-series models to 530 kHz offers the following advantages to customers.

• There is no longer any need to distinguish between models exported to the United States, and other countries,

and models marketed in Japan. This simplifies the processes of model selection and system design, and

reduces the chances of accidentally ordering the wrong models.

• This change makes it easier to combine various read/write heads and data carriers, thereby expanding the

options available when selecting models for system design. For example, it is now possible to use a single data

carrier in combination with the optimum read/write head for each process in an assembly line.

• For OMRON as well, this change makes it easier to improve production schedules and quality control by integrat-

ing product lines.

                                                                                                                   35
Discontinued Models and Replacements                                             Appendix B

Materials Provided Here

The following materials are provided in this appendix:

• Information regarding model changes

• Differences in specifications/performance between 500-kHz and 530-kHz models:

    • 530-kHz model specifications/performance

    • 500-kHz model specifications/performance

• Combining 500-kHz and 530-kHz models:

To some extent there are disadvantages such as a reduction in transmission range from combining 500-kHz and

530-kHz models. Considering the circumstances described above, please upgrade to the replacement models

whenever convenient.

36
Discontinued Models and Replacements                                                                               Appendix B

Model Changes

Discontinued Models

All 500-kHz models have been discontinued.

R/W head:          V600-H06

Data carriers:     V600-D2KR01, V600-D8KR01, V600-D2KR02, V600-D8KR02, V600-D2KR03, V600-D8KR03

From now on, please use 530-kHz models.

Replacement Models

The following table shows the models that are replacing each of the discontinued models.

                                            Discontinued model (500 kHz)                  Replacement model (530 kHz)

                                            V600-H06                             V600-H11 or V600-H12 (See note 1.)

                                            V600-DjKR01                          V600-D8KR11 or V600-D8KR04 (See note 2.)

                                            V600-D8KR02                          V600-D8KR12

                                            V600-D8KR03                          V600-D8KR13

Note          1.  The V600-H12 has the same specifications as thee V600-H06 except for the transmission range. The

                  V600-H11 is a compact, low-cost model.

              2.  The V600-D8KR11 can be flush-mounted in a metal casing. If the V600-DKR04 flush-mounted, the

                  restriction illustrated below applies. (In the V600-DKR04 diagram, the transmission range changes

                  according to distance x.

                  V600-D8KR11                                 V600-DKR04

                  ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ MetalFlush-mounted                    Flush-mounted

                                                  20 mm max.  x (mm)                            x (mm)

                                                                                                            20 mm max.

                                                                                 Metal

The following diagrams show the effect of the surrounding metal on the transmission range.

V600-H11/V600-D8KR04                                                        V600-H12/V600-D8KR04

                            (Shaft slip: ±0 mm)                                           (Shaft slip: ±0 mm)

(mm)                                                          (mm)

range                                                         range

Transmission                R/W  Head  DC                     Transmission                R/W Head      DC

                                 (over 100 mm)                                                  (over   100 mm)

              Gap  between  R/W  Head and metal (x)                         Gap  between  R/W Head and  metal (x)

                                                                                                                           37
Discontinued Models and Replacements                                                             Appendix               B

Specifications and Performance of                                    530-kHz Models

Data Carriers

V600-D8KR11

V600-D8KR12

V600-D8KR13

V600-D8KR04

       Item                                                          Model

                  (Standard type)     (Compact type)                        (Thin type)          (Mid-range type)

                  V600-D8KR11         V600-D8KR12                           V600-D8KR13          V600-D8K04

Memory capacity   8K bytes

Memory type       SRAM (static random access memory)

Transmission      (Refer to transmission range specifications on following page.)

range

Battery service   8 years            5 years                                8 years

life (See note.)

Number of data    No limit (up to the extent of the battery service life).

read/write

conversions

Error detection   16-bit CRC error detection is used in both directions of transmission.

Operating         –25°C to 70°C

temperature

Storage           –40°C to 70°C

temperature

Operating         35% to 95% RH

humidity

Storage humidity  35% to 95% RH

Degree of         Meets or exceeds IEC60529 IP67 and JEM IP67G standards for submersion and oil-resistance.

protection

Vibration         10 to 500 Hz, 1.0 mm in each direction; acceleration: 150 m/s2 (about 15 G); one sweep in each    of

resistance        three axis directions, three sweeps in 11 minutes

Shock             1,000 m/s2 (about 100 G) three times each in X, Y, Z directions

Dimensions        86 x 54 x 20 (mm)  65 x 40 x 15 (mm)                      86 x 54 x 10.3 (mm)  86 x 54 x 20 (mm)

Weight            Approx. 170 g      Approx. 70 g                                                Approx. 160 g

38
Discontinued Models  and  Replacements                                             Appendix B

R/W Heads

V600-H11                          Item                                     Model

V600-H12                                                  V600-H11                 V600-H12

                          Operating frequency    530 kHz

                          Operating temperature  –10°C to 60°C             –25°C to 70°C

                          Storage temperature    –25°C to 70°C             –40°C to 85°C

                          Operating humidity     35% to 95% RH

                          Storage humidity       35% to 95% RH

                          Degree of protection   Meets or exceeds IEC60529 IP67 and JEM IP67G

                                                 standards for submersion and oil-resistance.

                          Vibration resistance   10 to 500 Hz, 1.0 mm in each direction; acceleration: 150

                                                 m/s2 (about 15 G); X, Y, Z directions, 30 minutes

                          Shock resistance       500 m/s2 (about 50 G) three times in each direction

                          Dimensions             53 x 40 x 23 (mm)         100 x 70 x 30 (mm)

                          Weight                 Approx. 650 g (with 10-m  Approx. 1 kg (with 10-m

                                                 cable)                    cable)

                                                                                                            39
Discontinued Models and Replacements                                                            Appendix B

Transmission Range Specifications (Recommended Operating

Area)

When Combined With V600-H11

               Item                                                     Model

                                          V600-D8KR11    V600-D8KR12            V600-D8KR13     V600-D8KR04

Range  Stationary    Flush-mounted        10 to 50 mm    5 to 40 mm     10 to 30 mm             Refer to Graph

                     within metal                                                               A and the

       Moving        Surface-mounted  on  10 to 55 mm    5 to 45 mm     10 to 30 mm             transmission

                     metal                                                                      area diagrams.

       Stationary    Flush-mounted        30 to 50 mm    25 to 40 mm    15 to 30 mm

                     within metal

       Moving        Surface-mounted  on  30 to 55 mm    25 to 45 mm    15 to 30 mm

                     metal

                                                                                                (Shaft slip: ±10 mm)

                                      ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ MetalFlush-mounted  Surface-mounted

                                                                        ÉÉÉÉÉÉÉÉMeÉÉtal ÉÉÉÉÉÉ
The transmission range in the specifications is satisfied even if the back panel is not metal.

When Combined With V600-H12

               Item                                                     Model

                                          V600-D8KR11    V600-D8KR12            V600-D8KR13     V600-D8KR04

Range  Stationary    Flush-mounted        10 to 40 mm    5 to 25 mm     10 to 35 mm             Refer to Graph

                     within metal                                                               B and the

       Moving        Surface-mounted  on  15 to 45 mm    10 to 30 mm    15 to 40 mm             transmission

                     metal                                                                      area diagrams.

       Stationary    Flush-mounted        20 to 40 mm    15 to 25 mm    20 to 35 mm

                     within metal

       Moving        Surface-mounted  on  25 to 45 mm    20 to 30 mm    25 to 40 mm

                     metal

                                                                                                (Shaft slip: ±10 mm)

                                                         Flush-mounted

                                          x (mm)                        x (mm)

                                                                                20 mm max.

                                                         Metal

The restrictions illustrated in the above diagram apply when the V600-D8KR04 is flush-mounted in a metal casing.

40
Discontinued Models and Replacements                                                                     Appendix              B

Transmission Area Diagrams

The following diagrams are representative examples.          The  unit  of  measurement used is mm.

          V600-D8KR11 and V600-H11                                          V600-D8KR12 and V600-H11

          V600-D8KR13 and V600-H11                                          V600-D8KR04 and V600-H11

          V600-D8KR11 and V600-H12                                          V600-D8KR12 and V600-H12

          V600-D8KR13 and V600-H12                                          V600-D8KR04 and V600-H12

Graph  A

       V600-H06/V600-D8KR04                                                 V600-H12/V600-D8KR04

          (mm)          Shaft slip: ±0 mm)                                  (mm)          Shaft slip: ±0 mm)

          range                                                             range

          Transmission  R/W Head  DC                                        Transmission  R/W Head   DC

                        (over 100 mm)                                                     (over 100 mm)

                        Gap between R/W Head and metal  (x)                               Gap between R/W Head and metal  (x)

                                                                                                                               41
Discontinued Models and Replacements                                                                 Appendix           B

Note  All mounting conditions shown here are for metal back panel mounting.

Specifications and Performance of 500-kHz Models

Data Carrier

V600-D2KR01, V600-D8KR01

V600-D2KR02, V600-D8KR02

V600-D2KR03, V600-D8KR03

        Item                                                      Model

                                   V600-D2KR01                    V600-D2KR02                        V600-D2KR03

                                   V600-D8KR01                    V600-D8KR02                        V600-D8KR03

Memory capacity           2K bytes/8K bytes

Memory type               SRAM (static random access memory)

Battery service life      (Refer to transmission range specifications on following page.)

Battery life (See note.)  8 years                        5 years                           8 years

Number of data            No limit (up to the extent of the battery service life)

read/write conversions

Error detection           16-bit CRC error detection is used in both directions of transmission.

Operating temperature     –25°C to 70°C

Storage temperature       –40°C to 70°C

Operating humidity        35% to 95% RH

Storage humidity          35% to 95% RH

Degree of protection      Meets or exceeds IEC60529 IP67 and JEM IP67G standards for submersion and

                          oil-resistance.

Vibration resistance      10 to 500 Hz, 1.0 mm in each direction; acceleration: 150 m/s2 (about 15 G); one sweep in

                          each of three axis directions, three sweeps in 11 minutes

Shock resistance          1,000 m/s2 (about 100 G) three times each in X, Y, Z directions

Dimensions                86 x 54 x 20 (mm)              65 x 40 x 15 (mm)                 86 x 54 x 10.3 (mm)

Weight                    Approx. 170 g                  Approx. 70 g

Note  The battery service life shown here is the value that can be expected at 55°C, 100 bytes/access, and 1,000

      accesses/day.

R/W Head

V600-H06                                        Item                                       Model

                                                                                           V600-H06

                                   Operating frequency            500 kHz

                                   Operating temperature          –25°C to 70°C

                                   Storage temperature            –40°C to 85°C

                                   Operating humidity             35% to 95% RH

                                   Storage humidity               35% to 95% RH

                                   Degree of protection           Meets or exceeds IEC60529 IP67 and JEM IP67G

                                                                  standards for submersion and oil-resistance.

                                   Vibration resistance           0 to 500 Hz, 1.0 mm in each direction; acceleration:

                                                                  150 m/s2 (about 15 G); one sweep in each of three

                                                                  axis directions, three sweeps in 11 minutes

                                   Shock resistance               500 m/s2 (about 50 G) three times in each direction

                                   Dimensions                     100 x 70 x 30 (mm)

                                   Weight                         Approx. 1 kg (with 10 m cable)

42
Discontinued Models and Replacements                                                              Appendix B

Transmission Range Specifications (Recommended Operating

Area)

When Combined With V600-H06

                        Item                                                 Model

                                                    V600-D2KR01              V600-D2KR02          V600-D2KR03

                                                    V600-D8KR01              V600-D8KR02          V600-D8KR03

Range  Stationary       Flush-mounted within metal  10 to 35 mm              5 to 25 mm           10 to 35 mm

       Moving           Surface-mounted on metal    15 to 45 mm              10 to 30 mm          15 to 40 mm

       Stationary       Flush-mounted within metal  20 to 35 mm              15 to 25 mm          20 to 35 mm

       Moving           Surface-mounted on metal    25 to 40 mm              20 to 30 mm          25 to 40 mm

                                                                                                  (Shaft slip: ±10 mm)

                                 ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ MetalFlush-mounted                 Surface-mounted

                                                                             ÉÉÉÉÉÉÉÉMeÉÉtal ÉÉÉÉÉÉ

The transmission range  in the specifications is satisfied even if the back  panel is not metal.

Transmission Area Diagrams

The following diagrams are representative examples. The unit of measurement used is mm.

       V600-DjKR01 and V600-H06                                  V600-DjKR02 and V600-H06

       V600-DjKR03 and V600-H06

Note  All mounting conditions shown here are for metal back panel mounting.

Combining 500-kHz and 530-kHz Models

Transmission Range Specifications (Recommended Operating Area)

It is possible to use 500-kHz models and 530-kHz models in combination, but the transmission ranges are differ-

ent.

                                                                                                                 43
Discontinued Models and Replacements                                                                                          Appendix B

1) 500-KhZ R/W Head Combined With 530-kHz DC

• Combined With V600-H06

                                     Item                                                              Model

                                                                     V600-D8KR11          V600-D8KR12        V600-D8KR13      V600-D8KR04

Range                        Stationary    Flush-mounted             10 to 35 mm          5 to 25 mm         10 to 30 mm      Refer to Graph

                                           within metal                                                                       A and the

                             Moving        Surface-mounted       on  15 to 40 mm          10 to 30 mm        15 to 35 mm      transmission

                                           metal                                                                              area diagrams.

                             Stationary    Flush-mounted             20 to 35 mm          15 to 25 mm        20 to 30 mm

                                           within metal

                             Moving        Surface-mounted       on  25 to 40 mm          20 to 30 mm        25 to 35 mm

                                           metal

                                                                                                                          (Shaft slip: ±10 mm)

                                                                                                       Flush-mounted

                                                                                              x (mm)                  x (mm)

ÉÉÉÉÉÉÉÉÉFlusÉÉÉhM-emtÉÉÉaoluntÉÉÉed ÉÉÉÉÉÉ       ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ Surface-mounted                                                  20  mm  max.

                                                                     Metal                             Metal

                                                        Note     The transmission range       Note     The   restrictions   illus-

                                                                 in  the  specifications  is           trated in the above dia-

                                                                 satisfied even if the back            gram   apply   when    the

                                                                 panel is not metal.                   V600-D8KR04 is flush-

    Transmission range (mm)  (Shaft slip: ±0 mm)                                                       mounted in a metal cas-

                                                                                                       ing.  (The   data   varies

                                                                                                       depending on range x.)

                             R/W Head      DC

                                         (over 100 mm)

                             Gap between R/W Head and metal (x)

1) 530-KhZ R/W Head Combined With 500-kHz DC

• Combined With V600-H12

                                           Item                                                              Model

                                                                                  V600-D2KR01          V600-D2KR02            V600-D2KR03

                                                                                  V600-D8KR01          V600-D8KR02            V600-D8KR03

Range                        Stationary      Flush-mounted within metal     10 to 30 mm                5 to 20 mm          10 to 30 mm

                             Moving          Surface-mounted on metal       15 to 35 mm                10 to 25 mm         15 to 35 mm

                             Stationary      Flush-mounted within metal     20 to 30 mm                15 to 20 mm         20 to 30 mm

                             Moving          Surface-mounted on metal       25 to 35 mm                20 to 25 mm         25 to 35 mm

                                                                                                                          (Shaft slip: ±10 mm)

44
Discontinued Models and Replacements                                                     Appendix B

• Combined With V600-H11

                   Item                                            Model

                                                      V600-D2KR01  V600-D2KR02           V600-D2KR03

                                                      V600-D8KR01  V600-D8KR02           V600-D8KR03

Range  Stationary         Flush-mounted within metal  5 to 25 mm   5 to 20 mm            5 to 20 mm

       Moving             Surface-mounted on metal    5 to 30 mm   5 to 25 mm            5 to 25 mm

       Stationary         Flush-mounted within metal  15 to 25 mm  15 to 20 mm           15 to 20 mm

       Moving             Surface-mounted on metal    15 to 30 mm  15 to 25 mm           15 to 25 mm

                                                                                         (Shaft slip: ±10 mm)

Transmission Area Diagrams

The following diagrams are representative examples. The unit of measurement used is mm.

       V600-D8KR11 and V600-H06                                    V600-D8KR12 and V600-H06

       V600-D8KR13 and V600-H06                                    V600-D8KR04 and V600-H06

       V600-DjKR01 and V600-H12                                    V600-DjKR02 and V600-H12

       V600-DjKR03 and V600-H12

                                                                                                      45
Discontinued Models and Replacements                                                               Appendix   B

      V600-DjKR01 and V600-H11                                    V600-DjKR02 and V600-H11

      V600-DjKR03 and V600-H11

Note  All mounting conditions shown here are for metal back panel mounting.

Dimensions

V600-H06/12

                                                                  Power indicator (LED)

                                                                  Mounting holes (four, 4.5 dia.)

                                                                  Bushing    Cable (6 dia.;     Connector

                                                                             8 conductors, 7/0.12 dia.;    )

V600-H11

                                                 Mounting holes   PVC-clad cable (6 dia.;

                              Four, R1  Two, R5  (two, 4.5 dia.)  8 conductors, 7/0.12 dia.; )

                                                 Bushing                     Connector

                                                                             14.7 dia.

             Power/transmission

             indicator (LED)

46
Discontinued Models  and  Replacements                                 Appendix          B

                          Case material           ABS resin

                          Fill resin              Epoxy resin

                          Cable                   PVC (oil-resistant)

V600-DjKR01                                       V600-DjKR02

V600-D8KR11                                       V600-D8KR12

                          Mounting holes                       Mounting holes

                          (four, 4.5 dia.)                     (two, 4.5 dia.)

V600-DjKR03                                       V600-DjKR04

V600-D8KR13

                                 Mounting holes                        Mounting holes

                                 (two, 4.5 dia.)                       (four, 4.5 dia.)

                          Case material           ABS resin

                          Fill resin              Epoxy resin

                                                                                         47
                                      Appendix C

                                      Other Series

In England, R/W Heads and Data Carriers with a transmission frequency of 470 kHz must be used.

Model:  V600-H06-T (R/W Head)

        V600-D2KR01-T (Data Carrier)

Except for the transmission frequency, the specifications of the above 470-kHz models are exactly the same as

those of the V600-H06 and V600-D2KR01. For details, refer to Appendix B Discontinued Models and Replace-

ments.

                                                                                                               49
                                Revision History

A manual revision code appears as a suffix to the catalog number on the front cover of the manual.

                         Cat. No. Z127-E1-1

                                                     Revision code

The following table outlines the changes made to the manual during each revision. Page numbers refer  to  the

previous version.

Revision code      Date                              Revised content

1                  August 1998  Original production

                                                                                                          51
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Omron:

V600-H12 5M  V600-HA51 5M  V600-HA51 10M  V600-H12 2M  V600-HA51 2M  V600-HA51  0.5M  V600-CH1D-PSI

V600-CHUD 0.8M  V600-CHUD 1.9M  V600-CH1D-V2  V600-IDSC02
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 EEWORLD.com.cn, Inc. All rights reserved