datasheet

电子工程世界电子工程世界电子工程世界

型号

产品描述

搜索

UEI25-120-D48PM-C

器件型号:UEI25-120-D48PM-C
器件类别:半导体    电源管理   
厂商名称:Murata
厂商官网:https://www.murata.com
下载文档

器件描述

Isolated DC/DC Converters 48V 12Vout 2.1A SMT 25.2W Pos. Polarity

参数

产品属性属性值
Product AttributeAttribute Value
制造商:
Manufacturer:
Murata
产品种类:
Product Category:
Isolated DC/DC Converters
RoHS:YES
Number of Outputs:1 Output
Output Power:25.2 W
Input Voltage:36 V to 75 V
Output Voltage-Channel 1:12 V
Output Current-Channel 1:12 A
长度:
Length:
24.4 mm
宽度:
Width:
27.9 mm
高度:
Height:
8.1 mm
封装:
Packaging:
Tray
产品:
Product:
Isolated
商标:
Brand:
Murata Power Solutions
Moisture Sensitive:Yes
工厂包装数量:
Factory Pack Quantity:
100
单位重量:
Unit Weight:
0.320000 oz

UEI25-120-D48PM-C器件文档内容

www.murata-ps.com                                                                                                          UEI25 Series

                                                                                                        Single Output Isolated 25-Watt DC/DC Converters

                                                                      Output (V)                              Current (A)                   Nominal Input (V)

Typical unit                                                          3.3                                     7.5                           48

                                                                      5                                       5                             48

                                                                      12                                      2.1                           48

FEATURES                                                PRODUCT OVERVIEW

Cost effective small footprint DC/DC converter,       Featuring a full 25 Watt output in one square inch         offer fast settling to step transients and will accept

ideal for high current applications                     of board area, the UEI25 series isolated DC/DC             higher capacitive loads. Excellent ripple and noise

Industry standard 0.96" x 1.1" x 0.32" open           converter family offers efficient regulated DC power        specifications assure compatibility to noise-sus-

frame package and pinout                                for printed circuit board mounting. The 0.96" x 1.1"       ceptible circuits. For systems requiring controlled

Input voltage range of 36-75 Vdc                      x 0.32" (24.4 x 27.9 x 8.1 mm) converter accepts a         startup/shutdown, an external remote On/Off control

                                                        2:1 input voltage range of 36 to 75 Volts DC, ideal        may use a switch, transistor or digital logic.

3.3V, 5V, or 12Vdc fixed output voltages               for telecom equipment. The industry-standard pin-          A wealth of self-protection features avoid both

Isolation up to 2250 VDC (basic)                      out fits larger 1" x 2" converters. The fixed output         converter and external circuit faults. These include

                                                        voltage is tightly regulated. Applications include         input undervoltage lockout and overtemperature

Up to 25 Watts total output power with exten-         small instruments, area-limited microcontrollers,          shutdown. The outputs current limit using the

sive self-protection shutdown features                  data communications equipment, remote sensor               “hiccup” autorestart technique and the outputs are

High efficiency synchronous rectifier forward           systems, telephone equipment, vehicle and portable         short-circuit protected. Additional features include

topology up to 91%                                      electronics.                                               output overvoltage and reverse conduction elimina-

Stable operation with no required external            The UEI25 series includes full magnetic and                tion. The high efficiency offers minimal heat buildup

                                                        optical isolation with Basic protection up to 2250         and “no fan” operation.

components                                              Volts DC. For powering digital systems, the outputs

Usable -40 to 85°C temperature range (with

derating)

Certified to UL 60950-1, CAN/CSA-C22.2 No.

60950-1, IEC60950-1, EN60950-1 safety

approvals, 2nd edition

F1            +Vin (1)                                  *TPMBUJPO                                                                           +Vout (3)

                                                        Barrier

                                                                                     t4XJUDIJOH

External      On/Off                                                                 t'JMUFST

DC            Control                      Controller

Power               (6)                    and Power                                 t$VSSFOU4FOTF

Source                                        5SBOTGFS

              Open = On                                                              Reference and

              $MPTFE0GG                                                           Error Amplifier

              1PTJUJWF                                                                                                                     Trim (4)

              MPHJD


              -Vin (2)                                                                                                                      -Vout (5)

                                                                      Figure 1. Connection Diagram

                                                        Typical topology is shown. Murata Power Solutions

                                                                      recommends an external fuse.

                     

              For full details go to

              www.murata-ps.com/rohs                                  REG.-Nr. D806

www.murata-ps.com/support

                                                                                                                           MDC_UEI25W.B09              Page 1 of 24
                                                                                                                                                 UEI25 Series

                                                                                                                     Single Output Isolated 25-Watt DC/DC Converters

   PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ ➂

                                                   Output                                           Input

                                                R/N (mVp-p)        Regulation (Max.)                       IIN,      IIN,   Efficiency                         Package, C75

                            IOUT      Total                                               VIN           min.         full

                      VOUT  (A,       Power                                               Nom.  Range   load     load

   Root Models ➀      (V)   max)      (W)       Typ. ➁     Max.       Line  Load          (V)      (V)  (mA)         (A)   Min.     Typ.       Case (inches)  Case (mm)         Pinout

UEI25-033-D48 ➃       3.3   7.5       25        50            80   ±0.1%    ±0.2%         48    36-75      75    0.58      87.0%  89.5%        0.96x1.1x0.32  24.4x27.9x8.1     P85

UEI25-050-D48         5     5         25        50            80   ±0.1%    ±0.2%         48    36-75      30    0.57      89.0%    91%        0.96x1.1x0.32  24.4x27.9x8.1     P85

UEI25-120-D48         12    2.1       25.2      95            120  ±0.1%    ±0.1%         48    36-75      20        0.6   86.0%  87.5%        0.96x1.1x0.32  24.4x27.9x8.1     P85

Notes:

➀  Please refer to the part number structure for additional options and complete order-            Output capacitors are 1 μF ceramic in parallel with 10 μF electrolytic. The  input cap

   ing part numbers.                                                                               is 4.7 μF ceramic, low ESR.

➁  Ripple and Noise is shown at 20 MHz bandwidth.                                                  I/O caps are necessary for our test equipment and may not be needed for      your ap-

➂  All specifications are at nominal line voltage and full load, +25 °C. unless otherwise           plication.

   noted. See detailed specifications for full conditions.                                       ➃  Minimum load is 10% for rated specifications.

   PART  NUMBER  STRUCTURE

                                             UEI25         -  033  -  D48   P     M       Lx    -C

                      Unipolar Output Isolated                                                                   RoHS-6 Hazardous Substance Compliance

                      25-Watt Series                                                                             (Does not claim EU RoHS exemption 7b, lead in solder)

                            Nominal Output Voltage                                                 Pin Length Option (through-hole only)

                            in Tenths of a Volt                                                         Blank = Std. pin length 0.25˝ (6.3mm)

                                                                                                        L1 = 0.110˝ (2.79mm) ➀

                                                                                                        L2 = 0.145˝ (3.68mm) ➀

                                          Input Voltage Range                                  Surface Mount Option

                                                D48 = 36-75 Vdc                                 Blank = Through-hole mount

                                                                                                M = Surface mount (MSL rating 2) ➁

                                                                                          On/Off Control Logic:

                                                                                          P = Positive

                                                                                          N = Negative

   ➀     Special quantity order is required; samples available with standard pin length only.

   ➁     SMT (M) versions not available in sample quantities.

   ➂     Some model number combinations may not be available. See website or contact your local Murata sales representative.

   www.murata-ps.com/support

                                                                                                                                                        MDC_UEI25W.B09          Page 2 of 24
                                                                                                                                          UEI25 Series

                                                                                                                Single Output Isolated 25-Watt DC/DC Converters

FUNCTIONAL SPECIFICATIONS – MODEL UEI25-033-D48

ABSOLUTE MAXIMUM RATINGS          Conditions ➀                                                         Minimum           Typical/Nominal                          Maximum           Units

Input Voltage, Continuous         Full power operation                                                 0                                                          80                Vdc

Input Voltage, Transient          Operating or non-operating, 100 mS max.                              0                                                          100               Vdc

                                  duration

Isolation Voltage                 Input to output                                                                                                                 2250              Vdc

Input Reverse Polarity            None, install external fuse                                                            None                                                       Vdc

On/Off Remote Control             Power on or off, referred to -Vin                                    0                                                          15                Vdc

Output Power                                                                                           0                                                          25.25             W

Output Current                    Current-limited, no damage, short-circuit protected                  0                                                          7.5               A

Storage Temperature Range         Vin = Zero (no power)                                                -55                                                        125               ˚C

Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may  adversely affect  long-term reliability. Proper operation  under conditions  other than those

listed in the Performance/Functional Specifications Table is not implied or recommended.

INPUT

Operating voltage range                                                                                36                48                                       75                Vdc

Recommended External Fuse         Fast blow                                                                                                                       1.5               A

Start-up threshold                Rising input voltage                                                 34                35.2                                     36                Vdc

Undervoltage shutdown             Falling input voltage                                                32                34.0                                     35.2              Vdc

Overvoltage shutdown                                                                                                     None                                                       Vdc

Reverse Polarity Protection       None, install external fuse                                                            None                                                       Vdc

Internal Filter Type                                                                                                     LC

Input current

Full Load Conditions              Vin = nominal                                                                          0.58                                     0.60              A

Low Line                          Vin = minimum                                                                          0.79                                     0.81              A

Inrush Transient                                                                                                         0.05                                                       A2-Sec.

Output in Short Circuit                                                                                                  50                                       100               mA

No Load                           Iout = minimum, unit=ON                                                                75                                       100               mA

Standby Mode (Off, UV, OT)                                                                                               1                                        2                 mA

Reflected (back) ripple current ➁  Measured at input with specified filter                                                  30                                                         mA, RMS

Pre-biased startup                External output voltage < Vset                                                         Monotonic

GENERAL and SAFETY

Efficiency                         Vin=48V, full load                                                   87                89.5                                                       %

                                  Vin=36V, full load                                                   86.5              87.5                                                       %

Isolation

Isolation Voltage                 Input to output, continuous                                          2250                                                                         Vdc

Insulation Safety Rating                                                                                                 basic

Isolation Resistance                                                                                   10                                                                           Mohm

Isolation Capacitance                                                                                                    1000                                                       pF

Safety                            Certified to UL-60950-1, CSA-C22.2 No.60950-1,                                          Yes

                                  IEC/EN60950-1, 2nd edition

Calculated MTBF                   Per MIL-HDBK-217F, ground benign,                                                      TBD                                                        Hours x 106

                                  Tambient=+30˚C

Calculated MTBF                   Per Telcordia SR332, issue 1, class 3, ground                                          2                                                          Hours x 106

                                  fixed, Tambient=+40°C

DYNAMIC CHARACTERISTICS

Fixed Switching Frequency                                                                              300               330                                      360               KHz

Startup Time                      Power On to Vout regulated                                                                                                      50                mS

Startup Time                      Remote ON to Vout regulated                                                                                                     50                mS

Dynamic Load Response             50-75-50% load step, settling time to within                                           180                                      250               μSec

                                  ±2% of Vout

Dynamic load di/dt                                                                                                                                                2                 A/μSec

Dynamic Load Peak Deviation       same as above                                                                          ±30                                      ±100              mV

FEATURES and OPTIONS

Remote On/Off Control ➃

"N" suffix

Negative Logic, ON state          ON = Ground pin or external voltage                                  -0.7                                                       1.2               V

Negative Logic, OFF state         OFF = Pin open or external voltage                                   10                                                         15                V

Control Current                                                                                                          1                                                          mA

"P" suffix

Positive Logic, ON state          ON = Pin open or external voltage                                    10                                                         15                V

Positive Logic, OFF state         OFF = Ground pin or external voltage                                 -0.7                                                       1.2               V

Control Current                                                                                                          1                                                          mA

www.murata-ps.com/support

                                                                                                                                                                  MDC_UEI25W.B09    Page 3 of 24
                                                                                                                                              UEI25 Series

                                                                                                       Single Output Isolated 25-Watt DC/DC Converters

FUNCTIONAL SPECIFICATIONS (CONT.)            – MODEL UEI25-033-D48

   OUTPUT                                                    Conditions ➀ ➂                   Minimum                    Typical/Nominal      Maximum                       Units

Total Output Power                                           See Derating                     0.0                        25.0                 25.25                         W

Voltage

   Nominal Output Voltage                                    No trim                          3.267                      3.30                 3.333                         Vdc

   Setting Accuracy                                          At 50% load                      -1                                              +1                            % of Vset.

   Output Voltage Range                                      User-adjustable                  -10                                             +10                           % of Vnom.

   Overvoltage Protection                                    Via magnetic feedback            4.2                        5                    5.7                           Vdc

Current

   Output Current Range                                                                       0.7575                     7.575                7.575                         A

   Minimum Load ➂                                                                                                        10% minimum load                                   % of Iout

   Current Limit Inception                   98% of Vnom., after warmup                       8.5                        10                   11                            A

Short Circuit

   Short Circuit Current                     Hiccup technique, autorecovery                                                                   0.3                           A

   Short Circuit Duration (remove short for  Output shorted to ground, no damage                                         Continuous

   recovery)

   Short circuit protection method                           Current limiting

Regulation ➄

   Line Regulation                           Vin=min. to max., Vout=nom., 50% load                                                            ±0.1                          % of Vout

   Load Regulation                           Iout=min. to max., Vin=48V                                                                       ±0.2                          % of Vout

Ripple and Noise                                             5 Hz- 20 MHz BW                                             50                   80                            mV pk-pk

Temperature Coefficient                                       At all outputs                                              0.02                          % of Vnom./°C

Maximum Capacitive Loading (10% ceramic,     Cap. ESR=<0.02Ω, full resistive load             0                                               2000                          μF

   90% Oscon)

   MECHANICAL (Through Hole Models)                          Conditions ➀                     Minimum                    Typical/Nominal      Maximum                       Units

Outline Dimensions (no baseplate)                            C75 case                                                    0.9x1.1x0.32                                       Inches

   (Please refer to outline drawing)                         WxLxH                                                       22.86x27.9x8.1                                     mm

Weight                                                                                                                   0.32                                               Ounces

                                                                                                                         9.07                                               Grams

Through Hole Pin Diameter                                                                                                0.04                                               Inches

                                                                                                                         1.016                                              mm

Through Hole Pin Material                                                                                                Copper alloy

TH Pin Plating Metal and Thickness                           Nickel subplate                                             50                                                 μ-inches

                                                             Gold overplate                                              5                                                  μ-inches

   ENVIRONMENTAL

Operating Ambient Temperature Range          With derating, 200 LFM                           -40                                             85                            °C

                                                             No derating, 200 LFM             -40                                             70                            °C

Storage Temperature                                          Vin = Zero (no power)            -55                                             125                           °C

Thermal Protection/Shutdown                                  Measured in center               110                        115                  120                           °C

Electromagnetic Interference                 External filter is required

   Conducted, EN55022/CISPR22                                                                                            B                                                  Class

   Radiated, EN55022/CISPR22                                                                                             B                                                  Class

Relative humidity, non-condensing                            To +85°C                         10                                              90                            %RH

Altitude                                     must derate -1%/1000 feet                        -500                                            10,000                        feet

                                                                                              -152                                            3048                          meters

RoHS rating                                                                                                              RoHS-6

Notes

➀  Unless otherwise noted, all specifications are at nominal input voltage, nominal out-    ➂  All models are stable and regulate to specification under minimum (10%) load.

   put voltage and full load. General conditions are +25˚ Celsius ambient temperature,        Operation under no load will not damage the converter but may increase regulation,

   near sea level altitude, natural convection airflow. All models are tested and specified     output ripple, and noise.

   with external parallel 1 μF and 10 μF multi-layer ceramic output capacitors. The ex-    ➃  The Remote On/Off Control is referred to -Vin.

   ternal input capacitor is 4.7 μF ceramic. All capacitors are low-ESR types wired close  ➄  Regulation specifications describe the output voltage changes as the line voltage or

   to the converter. These capacitors are necessary for our test equipment and may not        load current is varied from its nominal or midpoint value to either extreme.

   be needed in the user's application.

➁  Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth.

   Input filtering is Cbus=220 μF, Cin=33 μF and Lbus=12 μH.

   www.murata-ps.com/support

                                                                                                                                              MDC_UEI25W.B09                Page 4 of 24
                                                                                                                                          UEI25 Series

                                                                                                                Single Output Isolated 25-Watt DC/DC Converters

FUNCTIONAL SPECIFICATIONS – MODEL UEI25-050-D48

ABSOLUTE MAXIMUM RATINGS          Conditions ➀                                                         Minimum           Typical/Nominal                          Maximum           Units

Input Voltage, Continuous         Full power operation                                                 0                                                          80                Vdc

Input Voltage, Transient          Operating or non-operating, 100 mS max.                              0                                                          100               Vdc

                                  duration

Isolation Voltage                 Input to output                                                                                                                 2250              Vdc

Input Reverse Polarity            None, install external fuse                                                            None                                                       Vdc

On/Off Remote Control             Power on or off, referred to -Vin                                    0                                                          15                Vdc

Output Power                                                                                           0                                                          25.25             W

Output Current                    Current-limited, no damage, short-circuit protected                  0                                                          5                 A

Storage Temperature Range         Vin = Zero (no power)                                                -55                                                        125               ˚C

Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may  adversely affect  long-term reliability. Proper operation  under conditions  other than those

listed in the Performance/Functional Specifications Table is not implied or recommended.

INPUT

Operating voltage range                                                                                36                48                                       75                Vdc

Recommended External Fuse         Fast blow                                                                                                                       1.5               A

Start-up threshold                Rising input voltage                                                 34                35                                       36                Vdc

Undervoltage shutdown             Falling input voltage                                                32                33.5                                     34.5              Vdc

Overvoltage shutdown                                                                                                     None                                                       Vdc

Reverse Polarity Protection       None, install external fuse                                                            None                                                       Vdc

Internal Filter Type                                                                                                     LC

Input current

Full Load Conditions              Vin = nominal                                                                          0.57                                     0.59              A

Low Line                          Vin = minimum                                                                          0.76                                     0.79              A

Inrush Transient                                                                                                         0.05                                                       A2-Sec.

Output in Short Circuit                                                                                                  50                                       100               mA

No Load                           Iout = minimum, unit=ON                                                                30                                       50                mA

Standby Mode (Off, UV, OT)                                                                                               1                                        3                 mA

Reflected (back) ripple current ➁  Measured at input with specified filter                                                  30                                                         mA, RMS

Pre-biased startup                External output voltage < Vset                                                         Monotonic

GENERAL and SAFETY

Efficiency                         Vin=48V, full load                                                   89                91                                                         %

                                  Vin=36V, full load                                                   89                91                                                         %

Isolation

Isolation Voltage                 Input to output, continuous                                          2250                                                                         Vdc

Insulation Safety Rating                                                                                                 basic

Isolation Resistance                                                                                   10                                                                           Mohm

Isolation Capacitance                                                                                                    2000                                                       pF

Safety                            Certified to UL-60950-1, CSA-C22.2 No.60950-1,                                          Yes

                                  IEC/EN60950-1, 2nd edition

Calculated MTBF                   Per MIL-HDBK-217F, ground benign,                                                      TBD                                                        Hours x 106

                                  Tambient=+30˚C

Calculated MTBF                   Per Telcordia SR332, issue 1, class 3, ground                                          2                                                          Hours x 106

                                  fixed, Tambient=+40°C

DYNAMIC CHARACTERISTICS

Fixed Switching Frequency                                                                              300               330                                      360               KHz

Startup Time                      Power On to Vout regulated                                                                                                      50                mS

Startup Time                      Remote ON to Vout regulated                                                                                                     50                mS

Dynamic Load Response             50-75-50% load step, settling time to within                                           200                                                        μSec

                                  ±2% of Vout

Dynamic load di/dt                                                                                                                                                2                 A/μSec

Dynamic Load Peak Deviation       same as above                                                                          ±150                                                       mV

FEATURES and OPTIONS

Remote On/Off Control ➃

"N" suffix

Negative Logic, ON state          ON = Ground pin or external voltage                                  -0.7                                                       0.7               V

Negative Logic, OFF state         OFF = Pin open or external voltage                                   10                                                         15                V

Control Current                                                                                                          1                                                          mA

"P" suffix

Positive Logic, ON state          ON = Pin open or external voltage                                    10                                                         15                V

Positive Logic, OFF state         OFF = Ground pin or external voltage                                 -0.7                                                       0.8               V

Control Current                                                                                                          1                                                          mA

www.murata-ps.com/support

                                                                                                                                                                  MDC_UEI25W.B09    Page 5 of 24
                                                                                                                                              UEI25 Series

                                                                                                       Single  Output Isolated                25-Watt DC/DC Converters

FUNCTIONAL SPECIFICATIONS (CONT.)            – MODEL UEI25-050-D48

   OUTPUT                                    Conditions ➀ ➂                                   Minimum          Typical/Nominal                Maximum                       Units

Total Output Power                           See Derating                                     0.0              25.0                           25.25                         W

Voltage

   Nominal Output Voltage                    No trim                                          4.95             5.00                           5.05                          Vdc

   Setting Accuracy                          At 50% load                                      -1                                              +1                            % of Vset.

   Output Voltage Range                      User-adjustable                                  -10                                             +10                           % of Vnom.

   Overvoltage Protection                    Via magnetic feedback                            6                6.5                            7.5                           Vdc

Current

   Output Current Range                                                                       0                5.0                            5.0                           A

   Minimum Load ➂                                                                                              No minimum load                                              % of Iout

   Current Limit Inception                   98% of Vnom., after warmup                       5.3              6.8                            7.3                           A

Short Circuit

   Short Circuit Current                     Hiccup technique, autorecovery                                                                   0.3                           A

   Short Circuit Duration (remove short for  Output shorted to ground, no damage                               Continuous

   recovery)

   Short circuit protection method           Current limiting

Regulation ➄

   Line Regulation                           Vin=min. to max., Vout=nom., 50% load                                                            ±0.1                          % of Vout

   Load Regulation                           Iout=min. to max., Vin=48V                                                                       ±0.2                          % of Vout

Ripple and Noise                             5 Hz- 20 MHz BW                                                   50                             80                            mV pk-pk

Temperature Coefficient                       At all outputs                                                    0.02                                              % of Vnom./°C

Maximum Capacitive Loading (10% ceramic,     Cap. ESR=<0.02Ω, full resistive load             0                                               2000                          μF

   90% Oscon)

   MECHANICAL (Through Hole Models)          Conditions ➀                                     Minimum          Typical/Nominal                Maximum                       Units

Outline Dimensions (no baseplate)            C75 case                                                          0.96x1.1x0.32                                                Inches

   (Please refer to outline drawing)         WxLxH                                                             24.4x27.9x8.1                                                mm

Weight                                                                                                         0.32                                                         Ounces

                                                                                                               9.07                                                         Grams

Through Hole Pin Diameter                                                                                      0.04                                                         Inches

                                                                                                               1.016                                                        mm

Through Hole Pin Material                                                                                      Copper alloy

TH Pin Plating Metal and Thickness           Nickel subplate                                                   50                                                           μ-inches

                                             Gold overplate                                                    5                                                            μ-inches

   ENVIRONMENTAL

Operating Ambient Temperature Range          With derating, 200 LFM                           -40                                             85                            °C

                                             No derating, 200 LFM, full power                 -40                                             82                            °C

Operating Case Temperature Range             No derating                                      -40                                             105                           °C

Storage Temperature                          Vin = Zero (no power)                            -55                                             125                           °C

Thermal Protection/Shutdown                  Measured in center                               110              115                            120                           °C

Electromagnetic Interference                 External filter is required

   Conducted, EN55022/CISPR22                                                                                  B                                                            Class

   Radiated, EN55022/CISPR22                                                                                   B                                                            Class

Relative humidity, non-condensing            To +85°C                                         10                                              90                            %RH

Altitude                                     must derate -1%/1000 feet                        -500                                            10,000                        feet

                                                                                              -152                                            3048                          meters

RoHS rating                                                                                                    RoHS-6

Notes

➀  Unless otherwise noted, all specifications are at nominal input voltage, nominal out-    ➁  Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth.

   put voltage and full load. General conditions are +25˚ Celsius ambient temperature,        Input filtering is Cbus=220 μF, Cin=33 μF and Lbus=12 μH.

   near sea level altitude, natural convection airflow. All models are tested and specified

   with external parallel 1 μF and 10 μF multi-layer ceramic output capacitors. The ex-    ➂  All models are stable and regulate to specification under no load.

   ternal input capacitor is 4.7 μF ceramic. All capacitors are low-ESR types wired close  ➃  The Remote On/Off Control is referred to -Vin.

   to the converter. These capacitors are necessary for our test equipment and may not     ➄  Regulation specifications describe the output voltage changes as the line voltage or

   be needed in the user's application.                                                       load current is varied from its nominal or midpoint value to either extreme.

   www.murata-ps.com/support

                                                                                                                                              MDC_UEI25W.B09                Page 6 of 24
                                                                                                                                          UEI25 Series

                                                                                                                Single Output Isolated 25-Watt DC/DC Converters

FUNCTIONAL SPECIFICATIONS – MODEL UEI25-120-D48

ABSOLUTE MAXIMUM RATINGS          Conditions ➀                                                         Minimum           Typical/Nominal                          Maximum           Units

Input Voltage, Continuous         Full power operation                                                 0                                                          80                Vdc

Input Voltage, Transient          Operating or non-operating, 100 mS max.                              0                                                          100               Vdc

                                  duration

Isolation Voltage                 Input to output                                                                                                                 2250              Vdc

Input Reverse Polarity            None, install external fuse                                                            None                                                       Vdc

On/Off Remote Control             Power on or off, referred to -Vin                                    0                                                          15                Vdc

Output Power                                                                                           0                                                          25                W

Output Current                    Current-limited, no damage, short-circuit protected                  0                                                          2.1               A

Storage Temperature Range         Vin = Zero (no power)                                                -55                                                        125               ˚C

Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may  adversely affect  long-term reliability. Proper operation  under conditions  other than those

listed in the Performance/Functional Specifications Table is not implied or recommended.

INPUT

Operating voltage range                                                                                36                48                                       75                Vdc

Recommended External Fuse         Fast blow                                                                                                                       1.5               A

Start-up threshold                Rising input voltage                                                 34                35.2                                     36                Vdc

Undervoltage shutdown             Falling input voltage                                                32                34.0                                     35.2              Vdc

Overvoltage shutdown                                                                                                     None                                                       Vdc

Reverse Polarity Protection       None, install external fuse                                                            None                                                       Vdc

Internal Filter Type                                                                                                     capacitive

Input current

Full Load Conditions              Vin = nominal                                                                          0.600                                    0.617             A

Low Line                          Vin = minimum                                                                          0.809                                    0.842             A

Inrush Transient                                                                                                         0.05                                                       A2-Sec.

Output in Short Circuit                                                                                                  50                                       100               mA

No Load                           Iout = minimum, unit=ON                                                                20                                       35                mA

Standby Mode (Off, UV, OT)                                                                                               1                                        2                 mA

Reflected (back) ripple current ➁  Measured at input with specified filter                                                  30                                                         mA, RMS

Pre-biased startup                External output voltage < Vset                                                         Monotonic

GENERAL and SAFETY

Efficiency                         Vin=48V, full load                                                   86.0              87.5                                                       %

Isolation

Isolation Voltage                 Input to output, continuous                                          2250                                                                         Vdc

Insulation Safety Rating                                                                                                 basic

Isolation Resistance                                                                                   10                                                                           Mohm

Isolation Capacitance                                                                                                    1700                                                       pF

Safety                            Certified to UL-60950-1, CSA-C22.2 No.60950-                                            Yes

                                  1, IEC/EN60950-1

Calculated MTBF                   Per MIL-HDBK-217F, ground benign,                                                      TBD                                                        Hours x 106

                                  Tambient=+30˚C

Calculated MTBF                   Per Telcordia SR332, issue 1, class 3, ground                                          2                                                          Hours x 106

                                  fixed, Tambient=+40°C

DYNAMIC CHARACTERISTICS

Fixed Switching Frequency                                                                              295               325                                      355               KHz

Startup Time                      Power On to Vout regulated                                                             10                                       50                mS

Startup Time                      Remote ON to Vout regulated                                                            10                                       50                mS

Dynamic Load Response             50-75-50% load step, settling time to within                                           100                                      200               μSec

                                  ±1% of Vout

Dynamic load di/dt                                                                                                                                                1                 A/μSec

Dynamic Load Peak Deviation       same as above                                                                          ±250                                     ±350              mV

FEATURES and OPTIONS

Remote On/Off Control ➃

"N" suffix

Negative Logic, ON state          ON = Ground pin or external voltage                                  -0.7                                                       0.7               V

Negative Logic, OFF state         OFF = Pin open or external voltage                                   10                                                         15                V

Control Current                                                                                                          1                                                          mA

"P" suffix

Positive Logic, ON state          ON = Pin open or external voltage                                    10                                                         15                V

Positive Logic, OFF state         OFF = Ground pin or external voltage                                 -0.7                                                       0.8               V

Control Current                                                                                                          1                                                          mA

www.murata-ps.com/support

                                                                                                                                                                  MDC_UEI25W.B09    Page 7 of 24
                                                                                                                                              UEI25 Series

                                                                                                       Single Output Isolated 25-Watt DC/DC Converters

FUNCTIONAL SPECIFICATIONS (CONT.) – MODEL UEI25-120-D48

   OUTPUT                                    Conditions ➀ ➂                                   Minimum  Typical/Nominal                        Maximum                       Units

Total Output Power                           See Derating                                     0.0      25.2                                   25.45                         W

Voltage

   Nominal Output Voltage                    No trim                                          11.88    12.00                                  12.12                         Vdc

   Setting Accuracy                          At 50% load                                      -1                                              +1                            % of Vset.

   Output Voltage Range                      User-adjustable                                  -10                                             +10                           % of Vnom.

   Overvoltage Protection                    Via magnetic feedback                            14       19                                     22                            Vdc

Current

   Output Current Range                                                                       0.0      2.1                                    2.1                           A

   Minimum Load ➂                                                                                      No minimum load

   Current Limit Inception                   97% of Vnom., after warmup                       2.3      3                                      3.4                           A

Short Circuit

   Short Circuit Current                     Hiccup technique, autorecovery within ±1.25%                                                     0.1                           A

                                             of Vout

   Short Circuit Duration (remove short for  Output shorted to ground, no damage                       Continuous

   recovery)

   Short circuit protection method           Current limiting

Regulation ➄

   Line Regulation                           Vin=min. to max., Vout=nom., 50% load                                                            ±0.075                        % of Vout

   Load Regulation                           Iout=min. to max., Vin=48V                                                                       ±0.05                         % of Vout

Ripple and Noise                             5 Hz- 20 MHz BW                                           95                                     120                           mV pk-pk

Temperature Coefficient                       At all outputs                                            0.02                                                      % of Vnom./°C

Maximum Capacitive Loading (10% ceramic,     Cap. ESR=<0.02Ω, full resistive load             0                                               470                           μF

   90% Oscon)

   MECHANICAL (Through Hole Models)          Conditions ➀                                     Minimum  Typical/Nominal                        Maximum                       Units

Outline Dimensions (no baseplate)            C75 case                                                  0.96x1.1x0.32                                                        Inches

   (Please refer to outline drawing)         WxLxH                                                     24.38x27.94x8.13                                                     mm

Weight                                                                                                 0.32                                                                 Ounces

                                                                                                       9.07                                                                 Grams

Through Hole Pin Diameter                                                                              0.04                                                                 Inches

                                                                                                       1.016                                                                mm

Through Hole Pin Material                                                                              Copper alloy

TH Pin Plating Metal and Thickness           Nickel subplate                                           50                                                                   μ-inches

                                             Gold overplate                                            5                                                                    μ-inches

   ENVIRONMENTAL

Operating Ambient Temperature Range          With derating, 200 LFM                           -40                                             85                            °C

Storage Temperature                          Vin = Zero (no power)                            -55                                             125                           °C

Thermal Protection/Shutdown                  Measured at hotspot                              130      135                                    150                           °C

Electromagnetic Interference                 External filter is required

   Conducted, EN55022/CISPR22                                                                          B                                                                    Class

   Radiated, EN55022/CISPR22                                                                           B                                                                    Class

Relative humidity, non-condensing            To +85°C                                         10                                              90                            %RH

Altitude                                     must derate -1%/1000 feet                        -500                                            10,000                        feet

                                                                                              -152                                            3048                          meters

RoHS rating                                                                                            RoHS-6

Notes

➀  Unless otherwise noted, all specifications are at nominal input voltage, nominal out-    ➁  Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth.

   put voltage and full load. General conditions are +25˚ Celsius ambient temperature,        Input filtering is Cbus=220 μF, Cin=33 μF and Lbus=12 μH.

   near sea level altitude, natural convection airflow. All models are tested and specified  ➂  All models are stable and regulate to specification under no load.

   with external parallel 1 μF and 10 μF multi-layer ceramic output capacitors. The ex-    ➃  The Remote On/Off Control is referred to -Vin.

   ternal input capacitor is 4.7 μF ceramic. All capacitors are low-ESR types wired close  ➄  Regulation specifications describe the output voltage changes as the line voltage or

   to the converter. These capacitors are necessary for our test equipment and may not        load current is varied from its nominal or midpoint value to either extreme.

   be needed in the user's application.

   www.murata-ps.com/support

                                                                                                                                              MDC_UEI25W.B09                Page 8 of 24
                                                                                                                                                                              UEI25 Series

                                                                                                                                         Single Output Isolated 25-Watt DC/DC Converters

               UEI25-033-D48 PERFORMANCE DATA

                             Efficiency vs. Line Voltage and Load Current @ 25°C                                                          Maximum Current Temperature Derating @sea level

               92                                                                                                                            (airflow is from input to output)

               87

               82                                                                                                             8

               77

               72

               67                                                                                                                            0.33 to 2.0 m/s (65 to 400 LFM)      0.33 m/s (65 LFM)

               62                           Vin =  36V                                                 Output Current (Amps)  7                  Vin = 36V, 48V, and 60V          0.5 m/s (100 LFM)

Efficiency (%)  57                           Vin =  48V                                                                                                                        1.0 to 2.0 m/s (200 to 400 LFM)

               52                                                                                                                                                                         Vin = 75V

               47                           Vin =  60V

               42                           Vin =  75V

               37                                                                                                             6

               32

               27

               22

               17                                                                                                             5

               12                                                                                                                30  35  40  45  50  55  60                   65  70      75                   80  85

               7                                                                                                                                 Ambient Temperature (°C)

                   0.2  0.7  1.2  1.7  2.2  2.7    3.2   3.7  4.2  4.7   5.2  5.7  6.2  6.7  7.2  7.7

                                                   Load  Current (Amps)

                                                              Thermal image with "hot spot" at full load current with 63°C ambient, air flowing at

                                                         minimal rate of 65 LFM. Air is flowing across the converter from +Vo to -Vo at 48V input.

                                                                   Identifiable and recommended maximum value to be verified in application.

               On/Off ENABLE DELAY (Vin=48, Vout=nom, Iout=7.5A, Cload=0uF, Ta=+25°C.,                 On/Off ENABLE DELAY (Vin=48, Vout=nom, Iout=.7575mA, Cload=0uF, Ta=+25°C.,

                             ScopeBW=20Mhz) Trace 1= Enable. Trace 4=Vout                                                                ScopeBW=20Mhz) Trace 1= Enable. Trace 4=Vout

www.murata-ps.com/support

                                                                                                                                                                              MDC_UEI25W.B09                   Page 9 of 24
                                                                                      UEI25 Series

                                                                                      Single Output Isolated 25-Watt DC/DC Converters

UEI25-033-D48 PERFORMANCE DATA, CONTINUED

On/Off ENABLE DELAY (Vin=48, Vout=nom, Iout=7.5A, Cload=2000uF, Ta=+25°C.,            Step Load Transient Response (Vin=48V, Vout=nom., Iout=50-75-50% of full load, Cload=

ScopeBW=20Mhz) Trace 1= Enable. Trace 4=Vout                                          1 uFb ceramic || 10uF tantalum, Ta=+25°C., ScopeBW=20Mhz)

Output Ripple and Noise (Vin=48V, Vout=nom., Iout=7.5A, Cload= 1 uFb ceramic || 10uF  Output Ripple and Noise (Vin=48V, Vout=nom., Iout=.7575mA, Cload= 1 uFb ceramic ||

tantalum, Ta=+25°C., ScopeBW=20Mhz)                                                   10uF tantalum, Ta=+25°C., ScopeBW=20Mhz)

www.murata-ps.com/support

                                                                                      MDC_UEI25W.B09 Page 10 of 24
                                                                                                                                                                                                     UEI25 Series

                                                                                                                                                         Single Output Isolated 25-Watt DC/DC Converters

UEI25-050-D48                           PERFORMANCE DATA

                             Efficiency  vs. Line Voltage and Load Current @                  25°C                                                            Power    Dissipation    vs. Load Current @          25°C

               92                                                                                                                    3.50

               91

               90                                                                                                                    3.00

               89

               88

               87                            Vin = 36V                                                                               2.50

               86                            Vin = 48V                                                                 Loss (Watts)

Efficiency (%)  85                            Vin = 60V

               84                            Vin = 75V                                                                               2.00

               83

               82                                                                                                                    1.50

               81

               80                                                                                                                                                                                         Vin =  36V

               79                                                                                                                    1.00                                                                 Vin =  48V

               78                                                                                                                                                                                         Vin =  60V

               77                                                                                                                                                                                         Vin =  75V

               76                                                                                                                    0.50

               75                                                                                                                          1.0      1.4      1.8      2.2      2.6   3.0             3.4         3.8   4.2  4.6  5.0

                   1.0  1.4  1.8        2.2  2.6        3.0                    3.4      3.8  4.2         4.6  5.0                                                              Load  Current (Amps)

                                             Load Current (Amps)

                                                                                        Maximum Current Temperature Derating @sea level

                                                                                        (VIN = 36V, 48V, 60V, and 75V, airflow is from pin 1 to pin                3)

                                                                               5.1

                                                                               5.0

                                                        Output Current (Amps)                      0.33  to 2.0 m/s (65 to 400 LFM)

                                                                               4.9

                                                                               4.8

                                                                               4.7

                                                                               4.6

                                                                               4.5  30  35   40    45         50   55                60         65       70       75       80  85

                                                                                                              Ambient temperature (°C)

                                                        Thermal image with "hot spot" at full load current with 80°C ambient, air flowing at

                                                  minimal rate of 65 LFM. Air is flowing across the converter from +Vo to -Vo at 48V input.

                                                                               Identifiable and recommended maximum value to be verified in application.

www.murata-ps.com/support

                                                                                                                                                                                                     MDC_UEI25W.B09 Page 11 of 24
                                                                                       UEI25 Series

                                                                                       Single Output Isolated 25-Watt DC/DC Converters

UEI25-050-D48 PERFORMANCE DATA, CONTINUED

On/Off Enable Delay (Vin=48V, Vout=nom., Iout=no load, Cload=0 μF, Ta=+25°C.,          On/Off Enable Delay (Vin=48V, Vout=nom., Iout=5A, Cload=0 μF, Ta=+25°C.,

ScopeBW=20MHz) Trace 1=Enable, Trace 4=Vout                                            ScopeBW=20MHz) Trace 1=Enable, Trace 4=Vout

On/Off Enable Delay (Vin=48V, Vout=nom., Iout=5A, Cload=2000 μF, Ta=+25°C.,            Step Load Transient Response (Vin=48V, Vout=nom., Iout=50-75-50% of full load, Cload=1

ScopeBW=20MHz) Trace 1=Enable, Trace 4=Vout                                            μF ceramic || 10μF tantalum, Ta=+25°C., ScopeBW=20MHz)

Output Ripple and Noise (Vin=48V, Vout=nom., Iout=no load, Cload=1 μF ceramic || 10μF  Output Ripple and Noise (Vin=48V, Vout=nom., Iout=5A, Cload=1 μF ceramic || 10μF

tantalum, Ta=+25°C., ScopeBW=20MHz)                                                    tantalum, Ta=+25°C., ScopeBW=20MHz)

www.murata-ps.com/support

                                                                                       MDC_UEI25W.B09 Page 12 of 24
                                                                                                                                                                                                   UEI25 Series

                                                                                                                                                               Single Output Isolated 25-Watt DC/DC Converters

                       UEI25-120-D48              PERFORMANCE DATA

                                       Efficiency  vs. Line Voltage and Load Current @            25°C                                                          Power  Dissipation  vs. Load Current     @  25°C

                       89                                                                                                                  4.46

                       88                                                                                                                  3.96

                       87

                                                                                                                                           3.46

                       86

                       85                                                     Vin =   36V                           Loss (Watts)           2.96

Efficiency (%)          84                                                     Vin =   48V                                                  2.46

                                                                              Vin =   60V

                       83                                                     Vin =   75V                                                  1.96

                       82                                                                                                                                                                                           Vin = 36V

                                                                                                                                           1.46                                                                     Vin = 48V

                       81                                                                                                                                                                                           Vin = 60V

                                                                                                                                           0.96                                                                     Vin = 75V

                       80

                       79                                                                                                                  0.46

                       78                                                                                                                        0.4      0.6  0.8      0.9  1.1   1.3             1.4     1.6      1.8        1.9  2.1

                           0.4    0.6  0.8            0.9  1.1   1.3          1.4           1.6      1.8  1.9  2.1                                                           Load  Current (Amps)

                                                           Load  Current      (Amps)

                                       Maximum Current Temperature Derating @sea                 level                                                         Maximum Current Temperature Derating @sea level

                                       (VIN = 36V, airflow is from pin 1 to pin 3)                                                                              (VIN = 48V, airflow is from pin 1 to pin 3)

                       2.25                                                                                                                2.2

                       2.2                                                                                                                 2.175

Output Current (Amps)  2.15                                                                                         Output Current (Amps)  2.15

                                                                                                                                                                                   0.33 m/s (65 LFM)

                                                           0.33 m/s (65 LFM)                                                               2.125                                   0.5 m/s (100 LFM)

                       2.1                                 0.5 m/s (100 LFM)                                                                                                       1.0 m/s (200 LFM)

                                                           1.0 m/s (200 LFM)                                                               2.1

                       2.05                                1.5 m/s (300 LFM)

                                                                                                                                           2.075

                       2.0

                                                                                                                                           2.05

                       1.95                                                                                                                2.025

                       1.9                                                                                                                       2

                              65                  70             75                              80            85                                     65            70             75                           80                  85

                                                           Ambient temperature (°C)                                                                                          Ambient temperature (°C)

                                       Maximum Current Temperature Derating @sea level                              Thermal image with "hot spot" at full load current with 65°C ambient, air flowing at

                                       (VIN = 60V, airflow is from pin 1 to pin 3)                                   minimal rate of 65 LFM. Air is flowing across the converter from +Vo to -Vo at 48V input.

                                                                                                                                           Identifiable and recommended maximum value to be verified in application.

                       2.2

                       2.175

Output Current (Amps)  2.15

                       2.125                               0.33 m/s (65 LFM)

                                                           0.5 m/s (100 LFM)

                       2.1                                 1.0 m/s (200 LFM)

                       2.075

                       2.05

                       2.025

                       2

                              65                  70             75                              80            85

                                                           Ambient temperature        (°C)

www.murata-ps.com/support

                                                                                                                                                                                                   MDC_UEI25W.B09 Page 13 of 24
                                                                                                    UEI25 Series

                                                                                                    Single Output Isolated 25-Watt DC/DC Converters

                       UEI25-120-D48 PERFORMANCE DATA, CONTINUED

                                 Maximum Current Temperature Derating @sea level                    On/Off ENABLE DELAY (Vin=48, Vout=nom, Iout=0A, Cload=0uF, Ta=+25°C.,

                                 (VIN = 75V, airflow is from pin 1 to pin 3)                         ScopeBW=20Mhz) Trace 1= Enable. Trace 4=Vout

                       2.2

                       2.15

Output Current (Amps)  2.1           0.33 m/s (65 LFM)

                                     0.5 m/s (100 LFM)

                       2.05          1.0 m/s (200 LFM)

                                     1.5 m/s (300 LFM)

                       1.95

                       1.9

                             65  70  75                                      80                 85

                                     Ambient temperature (°C)

                       On/Off ENABLE DELAY (Vin=48, Vout=nom, Iout=2.1A, Cload=0uF, Ta=+25°C.,      On/Off ENABLE DELAY (Vin=48, Vout=nom, Iout=2.1A, Cload=2000uF, Ta=+25°C.,

                                 ScopeBW=20Mhz) Trace 1= Enable. Trace 4=Vout                       ScopeBW=20Mhz) Trace 1= Enable. Trace 4=Vout

Stepload Transient Response (Vin = 48V, Iout = 25-75-25% of Imax, Cout = 1&10μF,                    Output Ripple and Noise (Vin=48V, Iout = 2.1A, Cout = 1&10μF, Ta = +25°C,

                                 Ta = +25°C, Scope BW = 20MHz)                                      Scope BW = 20MHz)

www.murata-ps.com/support

                                                                                                                       MDC_UEI25W.B09 Page 14 of 24
                                                                                                                    UEI25 Series

                                                                                      Single Output Isolated 25-Watt DC/DC Converters

MECHANICAL SPECIFICATIONS, OPEN FRAME THROUGH-HOLE MOUNT

                                                                                            Dimensions are in inches (mm shown for ref. only).

Case 75                                                                                                        Third Angle Projection

                                                          24.4                                    Tolerances (unless otherwise specified):

                                                          0.96                                    .XX ± 0.02 (0.5)

                                                                                                  .XXX ± 0.010 (0.25)

          PIN #1                                                                                  Angles ± 1˚

                                                                                                  Components are shown for reference only.

                            27.9                                                                  INPUT/OUTPUT CONNECTIONS

                            1.10                                                                  Pin               Function P85

                            TOP VIEW                                                              1                     +Vin

                                                                                                  2                     -Vin

                                                                                                  3                     +Vout

                                                                                                  4                     Output Trim

                                  SIDE VIEW                                                       5                     -Vout

MOUNTING                                                                                          6                 On/Off Control*

PLANE                                                                                             *The Remote On/Off can be provided

                                                          8.1                                     with either positive (P suffix) or nega-

                                                          0.32 MAX                                tive (N suffix) logic

                                                                                            These converters are plug-compatible to

                                                                                            competitive units. In case of pinout numbering

                                                          .040±.002 PIN DIAMETER            inconsistency, follow the pin FUNCTION, not

                                                          .071      .002 SHOULDER DIAMETER  the pin number when laying out your PC board.

                                                          6X AT PINS 1-6

                            BOTTOM VIEW                                                           END VIEW

                                    20.32                                                         0.475

                                    0.800                                                         [12.07]

                                    0.58                                                          REF

                                  [14.7]                            RECOMMENDED

          2.54              0.15 TYP                                PRI-SEC BARRIER

          0.100             [3.8]

                      0.41                                                10.16

                  [10.4]                                                  0.400

                                                                #3

          CL                                                                      CL

5.08                                                                      10.16

0.200             #1                                            #4        0.400

                  #2        0.30                                                            6.3

                            [7.62]                                                          0.25

                                           10.16                #5

                  #6                       0.400

                                      CL                                              Standard pin length is shown. Please refer to

                                                                                      the Ordering Guide for alternate pin lengths.

www.murata-ps.com/support

                                                                                                                    MDC_UEI25W.B09 Page 15 of 24
                                                                                                                                      UEI25 Series

                                                                                                     Single Output Isolated           25-Watt DC/DC Converters

SHIPPING TRAYS AND BOXES, THROUGH-HOLE MOUNT

                                                   Anti-static foam

                                                           Label

                                                                                                                                                             Label

                                                                         Each tray is 6 x 5 units

                                                                               (30 units per tray)

SHIPPING TRAY DIMENSIONS

UEI modules are supplied in a 30-piece (6 x 5) shipping tray. The tray          is  an  anti-static  closed-cell polyethylene  foam.  Dimensions are  shown  below.

                                   [9.92]

                          6.4      252.0

                          Typ

                6.4                     28.4               18.0
                                          Typ
                Typ

                25.4                                       5x 38.1

                Typ                                                                                       252.0                             252.0

[9.92]                                                                   190.5                            Ref                               Ref

252.0                                                                    Ref

        R 6.4                  A                        A

        Typ

                                   4x 44.5                                                           9.5 deep                         19.1

                                   177.8                                                             Ref                              Ref

                22.9               Ref

                                                                 9.5 [.38 in]

19.1 [.75 in]                                                    Pocket

                                                                 Depth

                                   SECTION A-A

        Notes:

        1. Material: Dow 220 antistat ethafoam

        (Density: 34-35 kg/m3)

        2. Dimensions: 252 x 252 x 19.1 mm

        6 x 5 array (30 per tray)

        3. All dimensions in millimeters [inches]

        4. Tolerances unless otherwise specified: +1/-0

www.murata-ps.com/support

                                                                                                                                      MDC_UEI25W.B09 Page 16 of 24
                                                                                                               UEI25 Series

                                                                              Single  Output Isolated 25-Watt DC/DC Converters

MECHANICAL SPECIFICATIONS, SURFACE MOUNT (MSL RATING 2)

                                                                                      Dimensions are in inches (mm shown for ref. only).

       Case 75                                                                                            Third Angle Projection

                                      TOP VIEW

                    PIN #1                                                                   Tolerances (unless otherwise specified):

                                                             24.4                            .XX ± 0.02 (0.5)

                                                             0.96                            .XXX ± 0.010 (0.25)

                                                                                             Angles ± 1˚

                                                                                      Components are shown for reference only.

                                                                                             INPUT/OUTPUT CONNECTIONS

                                                                                             Pin               Function P85

                                      27.9                                                        1                +Vin

                                      1.10                                                        2                -Vin

                                                                                                  3                +Vout

                                                                                                  4                Output Trim

                                      SIDE VIEW                                                   5                -Vout

                                                                                                  6            On/Off Control*

MOUNTING                                                                                     *The Remote On/Off can be provided

       PLANE                                                                                 with either positive (P suffix) or nega-

                                                                                             tive (N suffix) logic

                                                                                      These converters are plug-compatible to

                              0.093 [2.4] TYP                                         competitive units. In case of pinout numbering

                                                                                      inconsistency, follow the pin FUNCTION, not

                                                                                      the pin number when laying out your PC board.

                              BOTTOM VIEW                                                            END VIEW

                                      20.32

                                      0.800

                                      0.58

                                    [14.7]                   RECOMMENDED                                       0.34

                              0.15 TYP                       PRI-SEC BARRIER                                   [8.64]

       2.54                   [3.8]                                                                            MAX

       0.100

                        0.41                                       10.16

                    [10.4]                                         0.400

                                                         #3

                CL                                                        CL

5.08                                                               10.16              0.093

0.200               #1                                   #4        0.400              [2.4]

                    #2        0.30

                              [7.62]           10.16     #5                                  0.13 [3.3]

                    #6                         0.400                                         REF

                                      CL

www.murata-ps.com/support

                                                                                                                   MDC_UEI25W.B09 Page 17 of 24
                                                                                                                UEI25 Series

                                                                                       Single  Output Isolated  25-Watt DC/DC Converters

RECOMMENDED SMT PAD LAYOUT

                                          [20.32]

                                          0.800

        [2.60 ±0.25]

6X      .102    ±.010

                                   6                     5                                                      INPUT/OUTPUT CONNECTIONS

[2.54]                                                                                                          Pin       Function P85

0.100                                                              [10.16]                                      1                     +Vin

                                   2                     4         0.400                                        2                     -Vin

                                                                                   CL          [25.4]           3                     +Vout

                                   1                                                           1.00             4                     Output Trim

                                                                            [10.16]                             5                     -Vout

        [2.54]                                                              0.400                               6         On/Off Control*

        0.100                                            3                                                      *The Remote On/Off can be provided

                                                                                                                with either positive (P suffix) or nega-

                                                                                                                tive (N suffix) logic

                                            CL

                                            [29.0]

                                            1.14

SURFACE MOUNT TAPE AND REEL INFORMATION (MSL RATING  2)

                                                                   PACKAGING CONFORMS TO EIA-481

                                                                   CONVERTERS SHIPPING IN QUANTITIES

                                                                   OF 100 PER REEL

NOTE: The SMT package has an MSL 2 rating.

                                                            3.00                                               5.0mm Nozzle Pick &

                                                            0.118                      2.00            Place Location

                                                                                       0.079

                                                         23.10

                                                         0.909

                                            56.0

                                            2.20

                                                                   32.00

                                                                   1.260                       Feed  (unwind)  direction

                                                                   Pitch

                                          13.0                              Cover Tape

                                   R.256

                                                                                                                          9.27

        Dimensions in inches [mm]                                                                                         0.365

www.murata-ps.com/support

                                                                                                                MDC_UEI25W.B09               Page 18 of 24
                                                                                                                                      UEI25 Series

                                                                                                        Single Output Isolated 25-Watt DC/DC Converters

                               TECHNICAL NOTES                                        all applications, some experimentation may be needed. Note that external input

Input Fusing                                                                          capacitors must accept high speed switching currents.

Certain applications and/or safety agencies may require fuses at the inputs of        Because of the switching nature of DC/DC converters, the input of these

power conversion components. Fuses should also be used when there is the              converters must be driven from a source with both low AC impedance and

possibility of sustained input voltage reversal which is not current-limited. For     adequate DC input regulation. Performance will degrade with increasing input

greatest safety, we recommend a fast blow fuse installed in the ungrounded            inductance. Excessive input inductance may inhibit operation. The DC input

input supply line.                                                                    regulation specifies that the input voltage, once operating, must never degrade

The installer must observe all relevant safety standards and regulations. For         below the Shut-Down Threshold under all load conditions. Be sure to use

safety agency approvals, install the converter in compliance with the end-user        adequate trace sizes and mount components close to the converter.

safety standard.                                                                      I/O Filtering, Input Ripple Current and Output Noise

Input Reverse-Polarity Protection                                                     All models in this converter series are tested and specified for input reflected

If the input voltage polarity is reversed, an internal diode will become forward      ripple current and output noise using designated external input/output compo-

biased and likely draw excessive current from the power source. If this source        nents, circuits and layout as shown in the figures below. External input capaci-

is not current-limited or the circuit appropriately fused, it could cause perma-      tors (CIN in the figure) serve primarily as energy storage elements, minimizing

nent damage to the converter.                                                         line voltage variations caused by transient IR drops in the input conductors.

                                                                                      Users should select input capacitors for bulk capacitance (at appropriate

Input Under-Voltage Shutdown and Start-Up Threshold                                   frequencies), low ESR and high RMS ripple current ratings. In the figure below,

Under normal start-up conditions, converters will not begin to regulate properly      the CBUS and LBUS components simulate a typical DC voltage bus. Your specific

until the rising input voltage exceeds and remains at the Start-Up Threshold          system configuration may require additional considerations. Please note that the

Voltage (see Specifications). Once operating, converters will not turn off until       values of CIN, LBUS and CBUS may vary according to the specific converter model.

the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent

restart will not occur until the input voltage rises again above the Start-Up              TO

Threshold. This built-in hysteresis prevents any unstable on/off operation at a       OSCILLOSCOPE                           CURRENT

                                                                                                                             PROBE    1

single input voltage.                                                                                                                             +VIN

                                                                                           +                  LBUS

Users should be aware however of input sources near the Under-Voltage                 VIN  –

Shutdown whose voltage decays as input current is consumed (such as capacitor              +            CBUS                   CIN

inputs), the converter shuts off and then restarts as the external capacitor re-           –

charges. Such situations could oscillate. To prevent this, make sure the operating                                                    2           −VIN

input voltage is well above the UV Shutdown voltage AT ALL TIMES.                          CIN = 33μF, ESR < 700mΩ @ 100kHz

Start-Up Delay                                                                             CBUS = 220μF, ESR < 100mΩ @ 100kHz

Assuming that the output current is set at the rated maximum, the Vin to Vout Start-       LBUS = 12μH

Up Delay (see Specifications) is the time interval between the point when the rising                     Figure 2. Measuring Input Ripple Current

input voltage crosses the Start-Up Threshold and the fully loaded regulated output

voltage enters and remains within its specified regulation band. Actual measured       In critical applications, output ripple and noise (also referred to as periodic

times will vary with input source impedance, external input capacitance, input volt-  and random deviations or PARD) may be reduced by adding filter elements

age slew rate and final value of the input voltage as it appears at the converter.     such as multiple external capacitors. Be sure to calculate component tempera-

These converters include a soft start circuit to moderate the duty cycle of the       ture rise from reflected AC current dissipated inside capacitor ESR.

PWM controller at power up, thereby limiting the input inrush current.                Floating Outputs

The On/Off Remote Control interval from inception to VOUT regulated as-               Since these are isolated DC/DC converters, their outputs are “floating” with

sumes that the converter already has its input voltage stabilized above the           respect to their input. The essential feature of such isolation is ideal ZERO

Start-Up Threshold before the On command. The interval is measured from the           CURRENT FLOW between input and output. Real-world converters however do

On command until the output enters and remains within its specified regulation         exhibit tiny leakage currents between input and output (see Specifications).

band. The specification assumes that the output is fully loaded at maximum             These leakages consist of both an AC stray capacitance coupling component

rated current.                                                                        and a DC leakage resistance. When using the isolation feature, do not allow

                                                                                      the isolation voltage to exceed specifications. Otherwise the converter may

Input Source Impedance                                                                be damaged. Designers will normally use the negative output (-Output) as

These converters will operate to specifications without external components,           the ground return of the load circuit. You can however use the positive output

assuming that the source voltage has very low impedance and reasonable in-            (+Output) as the ground return to effectively reverse the output polarity.

put voltage regulation. Since real-world voltage sources have finite impedance,

performance is improved by adding external filter components. Sometimes only

a small ceramic capacitor is sufficient. Since it is difficult to totally characterize

www.murata-ps.com/support

                                                                                                                                      MDC_UEI25W.B09 Page 19 of 24
                                                                                                                         UEI25 Series

                                                                                                   Single Output Isolated 25-Watt DC/DC Converters

                                                                                    CAUTION: If you exceed these Derating guidelines, the converter may have

                                                                                    an unplanned Over Temperature shut down. Also, these graphs are all collected

+VOUT                                                                               near Sea Level altitude. Be sure to reduce the derating for higher altitude.

                                                                                    Output Overvoltage Protection (OVP)

                                C1   C2                SCOPE    RLOAD               This converter monitors its output voltage for an over-voltage condition using

                                                                                    an on-board electronic comparator. The signal is optically coupled to the pri-

−VOUT                                                                               mary side PWM controller. If the output exceeds OVP limits, the sensing circuit

                                                                                    will power down the unit, and the output voltage will decrease. After a time-out

                                                                                    period, the PWM will automatically attempt to restart, causing the output volt-

                  C1 = 1μF                                                          age to ramp up to its rated value. It is not necessary to power down and reset

                  C2 = 10μF                                                         the converter for this automatic OVP-recovery restart.

                  LOAD 2-3 INCHES (51-76mm) FROM MODULE                             If the fault condition persists and the output voltage climbs to excessive

Figure 3. Measuring Output Ripple and Noise (PARD)                                  levels, the OVP circuitry will initiate another shutdown cycle. This on/off cycling

                                                                                    is referred to as “hiccup” mode.

Minimum Output Loading Requirements                                                 Output Fusing

These converters employ a synchronous rectifier design topology. All models          The converter is extensively protected against current, voltage and temperature

regulate within specification and are stable from 0% load to full load conditions,   extremes. However, your application circuit may need additional protection. In the

unless otherwise specified. Operation under no load will not damage the con-         extremely unlikely event of output circuit failure, excessive voltage could be applied

verter but might, however, slightly increase regulation, output ripple, and noise.  to your circuit. Consider using an appropriate external protection.

Thermal Shutdown                                                                    Output Current Limiting

To protect against thermal over-stress, these converters include thermal shut-      As soon as the output current increases to approximately its overcurrent limit,

down circuitry. If environmental conditions cause the temperature of the DC/        the DC/DC converter will enter a current-limiting mode. The output voltage will

DC’s to rise above the Operating Temperature Range up to the shutdown tem-          decrease proportionally with increases in output current, thereby maintaining a

perature, an on-board electronic temperature sensor will power down the unit.       somewhat constant power output. This is commonly referred to as power limiting.

When the temperature decreases below the turn-on threshold, the converter

will automatically restart. There is a small amount of hysteresis to prevent        Current limiting inception is defined as the point at which full power falls

rapid on/off cycling. CAUTION: If you operate too close to the thermal limits, the  below the rated tolerance. See the Performance/Functional Specifications.

converter may shut down suddenly without warning. Be sure to thoroughly test        Note particularly that the output current may briefly rise above its rated value.

your application to avoid unplanned thermal shutdown.                               This enhances reliability and continued operation of your application. If the

Temperature Derating Curves                                                         output current is too high, the converter will enter the short circuit condition.

The graphs in the performance data section illustrate typical operation under a     Output Short Circuit Condition

variety of conditions. The Derating curves show the maximum continuous ambient      When a converter is in current-limit mode, the output voltage will drop as

air temperature and decreasing maximum output current which is acceptable under     the output current demand increases. If the output voltage drops too low, the

increasing forced airflow measured in Linear Feet per Minute (“LFM”). Note that      magnetically coupled voltage used to develop PWM bias voltage will also drop,

these are AVERAGE measurements. The converter will accept brief increases in tem-   thereby shutting down the PWM controller. Following a time-out period, the

perature and/or current or reduced airflow as long as the average is not exceeded.   PWM will restart, causing the output voltage to begin rising to its appropriate

Note that the temperatures are of the ambient airflow, not the converter it-         value. If the short-circuit condition persists, another shutdown cycle will initi-

self which is obviously running at higher temperature than the outside air. Also    ate. This on/off cycling is called “hiccup mode.” The hiccup cycling reduces the

note that “natural convection” is defined as very low flow rates which are not        average output current, thereby preventing excessive internal temperatures.

using fan-forced airflow. Depending on the application, “natural convection” is      Trimming the Output Voltage

usually about 30-65 LFM but is not equal to still air (0 LFM).                      The Trim input to the converter allows the user to adjust the output voltage over

Murata Power Solutions makes Characterization measurements in a closed              the rated trim range (please refer to the Specifications). In the trim equations

cycle wind tunnel with calibrated airflow. We use both thermocouples and an          and circuit diagrams that follow, trim adjustments use a single fixed resistor

infrared camera system to observe thermal performance. As a practical matter,       connected between the Trim input and either Vout pin. Trimming resistors should

it is quite difficult to insert an anemometer to precisely measure airflow in         have a low temperature coefficient (±100 ppm/°C or less) and be mounted close

most applications. Sometimes it is possible to estimate the effective airflow if     to the converter. Keep leads short. If the trim function is not used, leave the trim

you thoroughly understand the enclosure geometry, entry/exit orifice areas and       unconnected. With no trim, the converter will exhibit its specified output voltage

the fan flowrate specifications.                                                      accuracy.

www.murata-ps.com/support

                                                                                                                         MDC_UEI25W.B09 Page 20 of 24
                                                                                                                                            UEI25 Series

                                                                                                 Single Output Isolated 25-Watt DC/DC Converters

There are two CAUTIONs to observe for the Trim input:                                There are two CAUTIONs for the On/Off Control:

CAUTION: To avoid unplanned power down cycles, do not exceed EITHER the              CAUTION: While it is possible to control the On/Off with external logic if you

maximum output voltage OR the maximum output power when setting the trim.            carefully observe the voltage levels, the preferred circuit is either an open

If the output voltage is excessive, the OVP circuit may inadvertantly shut down      drain/open collector transistor or a relay (which can thereupon be controlled by

the converter. If the maximum power is exceeded, the converter may enter             logic). The On/Off prefers to be set at approx. +15V (open pin) for the ON state,

current limiting. If the power is exceeded for an extended period, the converter     assuming positive logic.

may overheat and encounter overtemperature shut down.                                CAUTION: Do not apply voltages to the On/Off pin when there is no input

CAUTION: Be careful of external electrical noise. The Trim input is a senstive       power voltage. Otherwise the converter may be permanently damaged.

input to the converter’s feedback control loop. Excessive electrical noise may

cause instability or oscillation. Keep external connections short to the Trim

input. Use shielding if needed.                                                                                           +VOUT

Trim Equations                                                                                         +VIN

                Trim Up                                  Trim Down

                                  UEI25-033-D48                                                        ON/OFF             TRIM                                    LOAD

                                                                                                       CONTROL                              RTRIM DOWN

RTUP  (Ω)  =    12775          –  2050  RTDOWN   (Ω)  =  5110 x (Vo –2.5)  –  2050

                VO – 3.3                                 3.3 – VO

                                  UEI25-050-D48                                                        −VIN               −VOUT

RTUP  (Ω)  =    12775          –  2050  RTDOWN   (Ω)  =  5110 x (Vo –2.5)  –  2050   Figure  4.  Trim adjustments   to    decrease  Output Voltage      using     a Fixed  Resistor

                VO – 5                                   5 – VO

                                  UEI25-120-D48                                                        +VIN               +VOUT

RTUP  (Ω)  =    25000          –  5110  RTDOWN   (Ω)  =  10000 (Vo-2.5)    –  5110

                VO – 12                                  12 – VO

                                                                                                       ON/OFF             TRIM                                    LOAD


between Trim and –Vout>                          between Trim and +Vout>

Where Vo = Desired output voltage. Adjustment accuracy is subject to resis-

tor tolerances and factory-adjusted output accuracy. Mount trim resistor close                         −VIN               −VOUT

to converter. Use short leads.

Remote On/Off Control                                                                Figure  5.  Trim  adjustments  to increase  Output     Voltage     using  a  Fixed  Resistor

On the input side, a remote On/Off Control can be specified with either positive

or negative logic as follows:

                                                                                                                                                +VCC

Positive: Models equipped with Positive Logic are enabled when the On/Off

pin is left open or is pulled high to +15VDC with respect to –VIN. An internal bias

current causes the open pin to rise to +VIN. Positive-logic devices are disabled                                    ON/OFF

when the On/Off is grounded or brought to within a low voltage (see Specifica-                                       CONTROL

tions) with respect to –VIN.

Negative: Models with negative logic are on (enabled) when the On/Off is                                            -VIN

grounded or brought to within a low voltage (see Specifications) with respect to

–VIN. The device is off (disabled) when the On/Off is left open or is pulled high

to +15VDC Max. with respect to –VIN.                                                 Figure 6. Driving the On/Off Control Pin (suggested circuit)

Dynamic control of the On/Off function should be able to sink the specified

signal current when brought low and withstand specified voltage when brought

high. Be aware too that there is a finite time in milliseconds (see Specifications)

between the time of On/Off Control activation and stable, regulated output. This

time will vary slightly with output load type and current and input conditions.

www.murata-ps.com/support

                                                                                                                                                MDC_UEI25W.B09 Page 21 of 24
                                                                                                                                                                  UEI25 Series

                                                                                                                                   Single Output Isolated 25-Watt DC/DC Converters

Emissions Performance                                                                                               dBμV                                      QP                             AV
                                                                                                                    100

Murata Power Solutions measures its products for radio frequency emissions                                          90

against the EN 55022 and CISPR 22 standards. Passive resistance loads are                                           80

employed and the output is set to the maximum voltage. If you set up your                                           70

own emissions testing, make sure the output load is rated at continuous power                                       60

while doing the tests.                                                                                              50

                                                                                                                    40

     The recommended external input and output capacitors (if required) are                                         30

included. Please refer to the fundamental switching frequency. All of this                                          20

                                                                                                                    10

information is listed in the Product Specifications. An external discrete filter is                                   0

installed and the circuit diagram is shown below.                                                                        0.15                            1.0                                 10.0              30.0
                                                                                                                                                                                                               MHz

                                                                                                                    Graph      2.  Conducted  emissions  performance with filter, Negative    Line, CISPR  22,  Class B,

                                        Test Card                                                                                             full       load, for UEI25-050-D48NM-C

                                                                     C4                       Resistive Load

DC Source  V+                                          L2            UUT

                                                                                              Resistive Load

                                                                                              inside a metal        dBμV                                      QP                             Average
                                                                                                                    100
           Black                                               Vin+       Vout+               container
                  C1                               C2      C3                    C6

                              L1                                                                                    90

                                                                                                                    80

           V-                                                  Vin-       Vout-                                     70

                                                                                                                    60

                                                                                                                    50

                                                                     C5                                             40

                                                                                                                    30

                          Figure 7. Conducted Emissions Test Circuit                                                20

                                                                                                                    10

                                                                                                                    0

[1] Conducted Emissions Parts List                                                                                       0.15                            1.0                                 10.0              30.0
                                                                                                                                                                                                               MHz

                                                                                                                    Graph      3.  Conducted  emissions performance without filter, Negative  Line, CISPR  22,  Class

Reference         Part Number                              Description                        Vendor                                          B, full load, for UEI25-050-D48NM-C

L1                PE-62913                                 1mH, 6A                            Pulse

L2                        NC                               4.7uH, 3.6A                        Murata

C1, C2            VZ Series                  Electrolytic Capacitor 22ufd, 100V               Panasonic

C3                VZ Series             Qty 2 - Electrolytic Capacitor 22ufd, 100V            Panasonic             dBμV                                      QP                             AV
                                                                                                                    100

C4, C5            Unknown                                  3.3nF, 1500V                       Unknown               90

C6                VZ Series                  Electrolytic Capacitor 22ufd, 100V               Panasonic             80

                                                                                                                    70

[2] Conducted Emissions Test Equipment Used                                                                         60

Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC                                                           50

Rohde & Schwarz Software ESPC-1 Ver. 2.20                                                                         40

                                                                                                                    30

OHMITE 25W – 1 Ohm resistor combinations                                                                          20

DC Source Programmable DC Power Supply Model 62012P-100-50                                                        10

                                                                                                                    0

                                                                                                                         0.15                            1.0                                 10.0              30.0
                                                                                                                                                                                                               MHz

[3] Conducted Emissions Test Results                                                                                Graph      4.  Conducted  emissions performance with filter, Negative     Line, CISPR  22,  Class B,

                                                                                                                                              full load, for UEI25-120-D48P-C

dBμV                                               QP                                AV
100

90

80

70

60                                                                                                                  [4] Layout Recommendations

50                                                                                                                  Most applications can use the filtering which is already installed inside the

40                                                                                                                  converter or with the addition of the recommended external capacitors. For

30                                                                                                                  greater emissions suppression, consider additional filter components and/or

20                                                                                                                  shielding. Emissions performance will depend on the user’s PC board layout,

10

0                                                                                                                   the chassis shielding environment and choice of external components.

     0.15                               1.0                                      10.0                         30.0
                                                                                                              MHz
                                                                                                                         Since many factors affect both the amplitude and spectra of emissions, we
Graph      1.  Conducted  emissions     performance with filter, Negative         Line, CISPR  22,  Class B,
                                                                                                                    recommend using an engineer who is experienced at emissions suppression.
                                  full  load, for UEI25-033-D48PM-C

www.murata-ps.com/support

                                                                                                                                                                  MDC_UEI25W.B09 Page 22 of 24
                                                                                                    UEI25 Series

                                                                       Single Output Isolated 25-Watt DC/DC Converters

                                                                       Vertical Wind Tunnel

                                                                       Murata Power Solutions employs a computer controlled

                                                                       custom-designed closed loop vertical wind tunnel, infrared

                                                                       video camera system, and test instrumentation for accurate

IR Transparent                                                         airflow and heat dissipation analysis of power products.

optical window                                                         The system includes a precision low flow-rate anemometer,

                                                            Variable   variable speed fan, power supply input and load controls,

                                                Unit under  speed fan  temperature gauges, and adjustable heating element.

                                                test (UUT)

IR Video                                                               The IR camera monitors the thermal performance of the

Camera                                                                 Unit Under Test (UUT) under static steady-state conditions. A

                                                                       special optical port is used which is transparent to infrared

                                                                       wavelengths.

                                                                       Both through-hole and surface mount converters are

                                                                       soldered down to a host carrier board for realistic heat

                                                            Heating    absorption and spreading. Both longitudinal and transverse

                                                            element    airflow studies are possible by rotation of this carrier board

Precision                                                              since there are often significant differences in the heat

low-rate                                                               dissipation in the two airflow directions. The combination of

anemometer                                                             adjustable airflow, adjustable ambient heat, and adjustable

3” below UUT                                                           Input/Output currents and voltages mean that a very wide

                                                                       range of measurement conditions can be studied.

Ambient                                                                The collimator reduces the amount of turbulence adjacent

temperature                                                            to the UUT by minimizing airflow turbulence. Such turbu-

sensor                                                                 lence influences the effective heat transfer characteristics

                                                                       and gives false readings. Excess turbulence removes more

                                                                       heat from some surfaces and less heat from others, possibly

                Airflow                                                 causing uneven overheating.

          collimator                                                   Both sides of the UUT are studied since there are different

                                                                       thermal gradients on each side. The adjustable heating element

                Figure 8. Vertical Wind Tunnel                         and fan, built-in temperature gauges, and no-contact IR camera mean

                                                            that power supplies are tested in real-world conditions.

www.murata-ps.com/support

                                                                                                    MDC_UEI25W.B09 Page 23 of 24
                                                                                                                          UEI25 Series

                                                                                                   Single Output Isolated 25-Watt DC/DC Converters

Through-hole Soldering Guidelines                                                         SMT Reflow Soldering Guidelines

Murata Power Solutions recommends the TH soldering specifications below when install-      The surface-mount reflow solder profile shown below is suitable for SAC305 type lead-

ing these converters. These specifications vary depending on the solder type. Exceeding    free solders. This graph should be used only as a guideline. Many other factors influence

these specifications may cause damage to the product. Your production environment may      the success of SMT reflow soldering. Since your production environment may differ,

differ; therefore please thoroughly review these guidelines with your process engineers.  please thoroughly review these guidelines with your process engineers.

Wave Solder Operations for through-hole  mounted products  (THMT)

For Sn/Ag/Cu based solders:

Maximum Preheat Temperature              115° C.

Maximum Pot Temperature                  270° C.

Maximum Solder Dwell Time                7 seconds

For Sn/Pb based solders:

Maximum Preheat Temperature              105° C.

Maximum Pot Temperature                  250° C.

Maximum Solder Dwell Time                6 seconds

Murata Power Solutions, Inc.                                                                       This product is subject to the following operating requirements

11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.                                                 and the Life and Safety Critical Application Sales Policy:

ISO 9001 and 14001 REGISTERED                                                                      Refer to: http://www.murata-ps.com/requirements/

                                                                                          Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other

                                                                                          technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply

                                                                                          the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without

                                                                                          notice.                         © 2013 Murata Power Solutions, Inc.

www.murata-ps.com/support

                                                                                                                          MDC_UEI25W.B09 Page 24 of 24
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Murata:

UEI25-033-D48P-C  UEI25-033-D48N-C  UEI25-050-D48P-C  UEI25-050-D48N-C  UEI25-120-D48P-C  UEI25-120-

D48N-C  UEI25-033-D48NM-C  UEI25-033-D48PM-C  UEI25-050-D48NM-C  UEI25-050-D48PM-C  UEI25-120-D48NM-

C  UEI25-120-D48PM-C

小广播

UEI25-120-D48PM-C器件购买:

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2017 EEWORLD.com.cn, Inc. All rights reserved